Page 146

Appendix

A–B

B

Discrete IIO Results Bits (Host Input & Output Bits) Introduction

This appendix lists the function of both the discrete bit inputs and outputs. These bits can be accessed through the Remote I/O port and Pyramid Integrator backplane. You cannot manipulate these bits through the RS–232 ports (A or B) but you can perform many of their functions.

Discrete Bit Inputs

With each inspection that the CVIM module performs, individual bits are set. There are 128 bits that can be set as inputs to a host device. These bits (part of the inspection results) indicate:

• Configuration faults. • Module Busy flag. • Missed Trigger flags. • Results Valid flags. • Inspection Tool Pass/Fail/Warning flags Note: If you are using the Remote I/O link, the bits for inspection tool pass/warning/fail apply to either toolset 1 or toolset 2. You select which toolset by setting bits 4 and 5 in word 3 of the discrete output bits. Note: For your convenience, we have provided bit numbers for both a PLC (octal) and Pyramid Integrator (decimal). Note to PLC–2 Users: When you use any PLC–2 family processor with the CVIM node adapter, you should understand the operation of the PLC Block Transfer Done bits for Read and Write instructions. PLC–2 family processors use the input image table for these bits all other PLCs can specify integer files for this function. This means that a PLC–2 user must use proper programming techniques to avoid confusion between the following bits:

• CVIM discrete I/O input word 0, bit 6 (data valid toolset #1) and bit 7 (data valid toolset #2).

• PLC–2 family input image table word 0, bit 6 (BTW done bit) and bit 7 (BTR done bit). Table B.1 lists the discrete bit inputs.

B–1

Page 147

Appendix B Discrete Bit Results

Discrete Bit Inputs (cont’d)

Table B.1 Discrete Bit Inputs

Word#

PI Backplane

Toolset 1

Toolset 2

16

280

Bit#

RS–232 and Remote I/O

0

D E C I M A L

O C T A L

PI

PLC

0

0

Definition

Usage

Notes

Configuration error bit is set after any invalid configuration or template block write to the CVIM. This flag is also set after validation errors.

Not Used

16

280

0

1

1

Configuration Error

0 = No Error 1 = Error

16

280

0

2

2

Mastership Flag

0 = Not Master 1 = Master

The device which reads this bit as 1 is the host. Not applicable for RS–232 communications.

16

280

0

3

3

Module Busy

0 = Not Busy 1 = Busy

Module Busy bit is set during the SETUP mode and during a download (sending configurations to the CVIM or reading/writing templates).

16

280

0

4

4

Trigger 1 NAK

0 = OK 1 = Trigger 1 Missed

16

280

0

5

5

Trigger 2 NAK

0 = OK 1 = Trigger 2 Missed

16

280

0

6

6

Toolset 1 Data Valid

0 = Not Valid 1 = Results Valid

Data Valid bit is reset when a user enters the SETUP mode. Refer to Chapter 3.

16

280

0

7

7

Toolset 2 Data Valid

0 = Not Valid 1 = Results Valid

Data Valid bit is reset when a user enters the SETUP mode. Refer to Chapter 3.

16

280

0

8

10

Reference Line 1 Flag

0 = Pass 1 = Failed

16

280

0

9

11

Reference Line 2 Flag

0 = Pass 1 = Failed

16

280

0

10

12

Reference Line 3 Flag

0 = Pass 1 = Failed

16

280

0

11

13

Reference Window 1 Flag

0 = Pass 1 = Failed

16

280

0

12

14

Reference Window 2 Flag

0 = Pass 1 = Failed

16

280

0

13

15

Reference Window 3 Flag

0 = Pass 1 = Failed

16

280

0

14

16

Light Probe Flag

0 = Pass 1 = Failed

16

280

0

15

17

Master Fault

0 = No Fault 1 = Fault

17

281

1

0

0

Window 1 Warning Flag

0 = Pass 1 = Failed

B–2

Master fault bit is set if any tool fails an inspection.

Page 148

Appendix B Discrete Bit Results

Table B.1 Discrete Bit Inputs Word#

PI Backplane

Bit#

RS–232 and Remote I/O

D E C I M A L

O C T A L

PI

PLC

Definition

Usage

Toolset 1

Toolset 2

17

281

1

1

1

Window 1 Fault Flag

0 = Pass 1 = Fail

17

281

1

2

2

Widow 2 Warning Flag

0 = Pass 1 = Fail

17

281

1

3

3

Window 2 Fault Flag

0 = Pass 1 = Fail

17

281

1

4

4

Window 3 Warning Flag

0 = Pass 1 = Fail

17

281

1

5

5

Window 3 Fault Flag

0 = Pass 1 = Fail

17

281

1

6

6

Window 4 Warning Flag

0 = Pass 1 = Fail

17

281

1

7

7

Window 4 Fault Flag

0 = Pass 1 = Fail

17

281

1

8

10

Window 5 Warning Flag

0 = Pass 1 = Fail

17

281

1

9

11

Window 5 Fault Flag

0 = Pass 1 = Failed

17

281

1

10

12

Window 6 Warning Flag

0 = Pass 1 = Failed

17

281

1

11

13

Window 6 Fault Flag

0 = Pass 1 = Failed

17

281

1

12

14

Window 7 Warning Flag

0 = Pass 1 = Failed

17

281

1

13

15

Window 7 Fault Flag

0 = Pass 1 = Failed

17

281

1

14

16

Window 8 Warning Flag

0 = Pass 1 = Failed

17

281

1

15

17

Window 8 Fault Flag

0 = Pass 1 = Failed

18

282

2

0

0

Window 9 Warning Flag

0 = Pass 1 = Failed

18

282

2

1

1

Window 9 Fault Flag

0 = Pass 1 = Failed

18

282

2

2

2

Window 10 Warning Flag

0 = Pass 1 = Failed

18

282

2

3

3

Window 10 Fault Flag

0 = Pass 1 = Failed

Notes

B–3

Page 149

Appendix B Discrete Bit Results

Discrete Bit Inputs (cont’d)

Table B.1 Discrete Bit Inputs

Word#

PI Backplane

Bit#

RS–232 and Remote I/O

D E C I M A L

O C T A L

PI

PLC

Definition

Usage

Toolset 1

Toolset 2

18

282

2

4

4

Widow 11 Warning Flag

0 = Pass 1 = Fail

18

282

2

5

5

Window 11 Fault Flag

0 = Pass 1 = Fail

18

282

2

6

6

Window 12 Warning Flag

0 = Pass 1 = Fail

18

282

2

7

7

Window 12 Fault Flag

0 = Pass 1 = Fail

18

282

2

8

10

Window 13 Warning Flag

0 = Pass 1 = Fail

18

282

2

9

11

Window 13 Fault Flag

0 = Pass 1 = Fail

18

282

2

10

12

Window 14 Warning Flag

0 = Pass 1 = Fail

18

282

2

11

13

Window 14 Fault Flag

0 = Pass 1 = Failed

18

282

2

12

14

Window 15 Warning Flag

0 = Pass 1 = Failed

18

282

2

13

15

Window 15 Fault Flag

0 = Pass 1 = Failed

18

282

2

14

16

Window 16 Warning Flag

0 = Pass 1 = Failed

18

282

2

15

17

Window 16 Fault Flag

0 = Pass 1 = Failed

19

283

3

0

0

Window 17 Warning Flag

0 = Pass 1 = Failed

19

283

3

1

1

Window 17 Fault Flag

0 = Pass 1 = Failed

19

283

3

2

2

Window 18 Warning Flag

0 = Pass 1 = Failed

19

283

3

3

3

Window 18 Fault Flag

0 = Pass 1 = Failed

19

283

3

4

4

Window 19 Warning Flag

0 = Pass 1 = Failed

19

283

3

5

5

Window 19 Fault Flag

0 = Pass 1 = Failed

19

283

3

6

6

Window 20 Warning Flag

0 = Pass 1 = Failed

B–4

Notes

Page 150

Appendix B Discrete Bit Results

Table B.1 Discrete Bit Inputs Word#

PI Backplane

Bit#

RS–232 and Remote I/O

D E C I M A L

O C T A L

PI

PLC

Definition

Usage

Toolset 1

Toolset 2

19

283

3

7

7

Widow 20 Fault Flag

0 = Pass 1 = Fail

19

283

3

8

10

Window 21 Warning Flag

0 = Pass 1 = Fail

19

283

3

9

11

Window 21 Fault Flag

0 = Pass 1 = Fail

19

283

3

10

12

Window 22 Warning Flag

0 = Pass 1 = Fail

19

283

3

11

13

Window 22 Fault Flag

0 = Pass 1 = Fail

19

283

3

12

14

Window 23 Warning Flag

0 = Pass 1 = Fail

19

283

3

13

15

Window 23 Fault Flag

0 = Pass 1 = Fail

19

283

3

14

16

Window 24 Warning Flag

0 = Pass 1 = Failed

19

283

3

15

17

Window 24 Fault Flag

0 = Pass 1 = Failed

20

284

4

0

0

Gage 1 Warning Flag

0 = Pass 1 = Failed

20

284

4

1

1

Gage 1 Fault Flag

0 = Pass 1 = Failed

20

284

4

2

2

Gage 2 Warning Flag

0 = Pass 1 = Failed

20

284

4

3

3

Gage 2 Fault Flag

0 = Pass 1 = Failed

20

284

4

4

4

Gage 3 Warning Flag

0 = Pass 1 = Failed

20

284

4

5

5

Gage 3 Fault Flag

0 = Pass 1 = Failed

20

284

4

6

6

Gage 4 Warning Flag

0 = Pass 1 = Failed

20

284

4

7

7

Gage 4 Fault Flag

0 = Pass 1 = Failed

20

284

4

8

10

Gage 5 Warning Flag

0 = Pass 1 = Failed

20

284

4

9

11

Gage 5 Fault Flag

0 = Pass 1 = Failed

Notes

B–5

Page 151

Appendix B Discrete Bit Results

Discrete Bit Inputs (cont’d)

Table B.1 Discrete Bit Inputs

Word#

PI Backplane

Bit#

RS–232 and Remote I/O

D E C I M A L

O C T A L

PI

PLC

Definition

Usage

Toolset 1

Toolset 2

20

284

4

10

12

Gage 6 Warning Flag

0 = Pass 1 = Fail

20

284

4

11

13

Gage 6 Fault Flag

0 = Pass 1 = Fail

20

284

4

12

14

Gage 7 Warning Flag

0 = Pass 1 = Fail

20

284

4

13

15

Gage 7 Fault Flag

0 = Pass 1 = Fail

20

284

4

14

16

Gage 8 Warning Flag

0 = Pass 1 = Fail

20

284

4

15

17

Gage 8 Fault Flag

0 = Pass 1 = Fail

21

285

5

0

0

Gage 9 Warning Flag

0 = Pass 1 = Failed

21

285

5

1

1

Gage 9 Fault Flag

0 = Pass 1 = Failed

21

285

5

2

2

Gage 10 Warning Flag

0 = Pass 1 = Failed

21

285

5

3

3

Gage 10 Fault Flag

0 = Pass 1 = Failed

21

285

5

4

4

Gage 11 Warning Flag

0 = Pass 1 = Failed

21

285

5

5

5

Gage 11 Fault Flag

0 = Pass 1 = Failed

21

285

5

6

6

Gage 12 Warning Flag

0 = Pass 1 = Failed

21

285

5

7

7

Gage 12 Fault Flag

0 = Pass 1 = Failed

21

285

5

8

10

Gage 13 Warning Flag

0 = Pass 1 = Failed

21

285

5

9

11

Gage 13 Fault Flag

0 = Pass 1 = Failed

21

285

5

10

12

Gage 14 Warning Flag

0 = Pass 1 = Failed

21

285

5

11

13

Gage 14 Fault Flag

0 = Pass 1 = Failed

21

285

5

12

14

Gage 15 Warning Flag

0 = Pass 1 = Failed

B–6

Notes

Page 152

Appendix B Discrete Bit Results

Table B.1 Discrete Bit Inputs Word#

PI Backplane

Bit#

RS–232 and Remote I/O

D E C I M A L

O C T A L

PI

PLC

Definition

Usage

Toolset 1

Toolset 2

21

285

5

13

15

Gage 15 Fault Flag

0 = Pass 1 = Fail

21

285

5

14

16

Gage 16 Warning Flag

0 = Pass 1 = Fail

21

285

5

15

17

Gage 16 Fault Flag

0 = Pass 1 = Fail

22

286

6

0

0

Gage 17 Warning Flag

0 = Pass 1 = Fail

22

286

6

1

1

Gage 17 Fault Flag

0 = Pass 1 = Fail

22

286

6

2

2

Gage 18 Warning Flag

0 = Pass 1 = Failed

22

286

6

2

2

Gage 18 Fault Flag

0 = Pass 1 = Failed

22

286

6

3

3

Gage 19 Warning Flag

0 = Pass 1 = Failed

22

286

6

4

4

Gage 19 Fault Flag

0 = Pass 1 = Failed

22

286

6

5

5

Gage 20 Warning Flag

0 = Pass 1 = Failed

22

286

6

7

7

Gage 20 Fault Flag

0 = Pass 1 = Failed

22

286

6

8

10

Gage 21 Warning Flag

0 = Pass 1 = Failed

22

286

6

9

11

Gage 21 Fault Flag

0 = Pass 1 = Failed

22

286

6

10

12

Gage 22 Warning Flag

0 = Pass 1 = Failed

22

286

6

11

13

Gage 22 Fault Flag

0 = Pass 1 = Failed

22

286

6

12

14

Gage 23 Warning Flag

0 = Pass 1 = Failed

22

286

6

13

15

Gage 23 Fault Flag

0 = Pass 1 = Failed

22

286

6

14

16

Gage 24 Warning Flag

0 = Pass 1 = Failed

22

286

6

15

17

Gage 24 Fault Flag

0 = Pass 1 = Failed

Notes

B–7

Page 153

Appendix B Discrete Bit Results

Discrete Bit Inputs (cont’d)

Table B.1 Discrete Bit Inputs

Word#

PI Backplane

Bit#

RS–232 and Remote I/O

D E C I M A L

O C T A L

PI

PLC

Definition

Usage

Toolset 1

Toolset 2

23

287

7

0

0

Gage 25 Warning Flag

0 = Pass 1 = Fail

23

287

7

1

1

Gage 25 Fault Flag

0 = Pass 1 = Fail

23

287

7

2

2

Gage 26 Warning Flag

0 = Pass 1 = Fail

23

287

7

3

3

Gage 26 Fault Flag

0 = Pass 1 = Fail

23

287

7

4

4

Gage 27 Warning Flag

0 = Pass 1 = Failed

23

287

7

5

5

Gage 27 Fault Flag

0 = Pass 1 = Failed

23

287

7

6

6

Gage 28 Warning Flag

0 = Pass 1 = Failed

23

287

7

7

7

Gage 28 Fault Flag

0 = Pass 1 = Failed

23

287

7

8

10

Gage 29 Warning Flag

0 = Pass 1 = Failed

23

287

7

9

11

Gage 29 Fault Flag

0 = Pass 1 = Failed

23

287

7

10

12

Gage 30 Warning Flag

0 = Pass 1 = Failed

23

287

7

11

13

Gage 30 Fault Flag

0 = Pass 1 = Failed

23

287

7

12

14

Gage 31 Warning Flag

0 = Pass 1 = Failed

23

287

7

13

15

Gage 31 Fault Flag

0 = Pass 1 = Failed

23

287

7

14

16

Gage 32 Warning Flag

0 = Pass 1 = Failed

23

287

7

15

17

Gage 32 Fault Flag

0 = Pass 1 = Failed

B–8

Notes

Page 154

Appendix B Discrete Bit Results

Discrete Bit Outputs

There are 128 bits that can be set as outputs from a host device to control the operation of the CVIM. These bits control:

• Monitor display. • Camera trigger. • Toolset selection. • I/O forcing. • Selection of operation after reject. • Memory storage location. RAM, EEPROM, RAM Card, or external host memory. Refer to Tables B.2 and B.3. Table B.2 only applies to Backplane communications. Table B.3 applies to both Backplane and Remote I/O communications. Table B.2 Backplane Handshake Bits Word # PI Backplane

RS–232 and Remote I/O

Bit # PI

0

N/A

0

Host Data Lock – Toolset #1

0 = CVIM May Write 1 = CVIM Write Inhibited

The backplane host should write to bit 0 to prevent the CVIM from modifying toolset 1 results data.

0

N/A

1

Host Data Lock – Toolset #2

0 = CVIM May Write 1 = CVIM Write Inhibited

The backplane host should write to bit 1 to prevent the CVIM from modifying Toolset 2 results data.

0

N/A

2

CVIM Data Lock – Toolset #1

0 = CVIM Not Writing 1 = CVIM Writing

The CVIM sets bit 2 while writing to Toolset 1. The bit will be set back to 0 after writing.

0

N/A

3

CVIM Data Lock – Toolset #2

0 = CVIM Not Writing 1 = CVIM Writing

The CVIM sets bit 3 while writing while writing to Toolset 2. The bit will be set back to 0 after writing.

0

N/A

4–15

Reserved

Definition

Usage

Notes

B–9