Page 164

Appendix

C

Numerical Results Data Results Block Overview

There are 4 results blocks for each toolset. The following is an overview of the blocks. Block Number 1 Contains:

• Block Transfer Signature • Discrete Output Copy • Brightness Probe • X/Y Reference Lines #1, #2, and #3 • Feature Finder #1 • Windows 1–8 • Gages 1–8 • Total Number of Triggers, Missed Triggers, and Master Faults Block #2 Contains:

• Block Transfer Signature • Windows 9–16 • Gages 9–22 • Windows 17–24 • Total Number of Triggers Block #3 Contains:

• Block Transfer Signature • Gages 23–32 • Feature Finders #2 and #3 • Total Number of Triggers, Missed Triggers, and Master Faults Block #4 (Remote I/O Port only) Contains:

• Block Transfer Signature • Status Word • User Programmable Block Transfer Data • Total Number of Triggers

C–1

Page 165

Appendix C Numerical Results Data

Block Transfer Signature

The block transfer signature is for user information only. The CVIM places the signature in each block sent to the PLC for identification and does not care if the PLC changes the signature prior to sending a block back to the CVIM. Bits 0–7 designate the block number: 00000000 = Not Valid 00000001 = Block #1 00000010 = Block #2 ... 11111111 = Block #255

Bits 8–10 designate the toolset: 000 = Not Valid 001 = Toolset #1 010 = Toolset #2 011 to 111 = Reserved

Bits 11 and 12 designate the block type: 00 = Results 01 = Configuration 10 = Templates 11 = Statistics

Bits 13–15 specify the module thumbwheel number: 000 to 111

C–2

Page 166

Appendix C Numerical Results Data

Results Block #1

Table C.1 shows the function of each word in Results Block #1. Table C.1 Numerical Results Data – Results Block 1

Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

24

288

0

0 – 15

Block Transfer Signature

25

289

1

0 – 15

Reserved

26

290

2

0 – 15

Brightness Probe Integer

16 . 16 value. Refer to Appendix A.

27

291

3

0 – 15

Brightness Probe Fraction

16 . 16 value. Refer to Appendix A.

28

292

4

0 – 15

Reference Line #1X Position

From upper left corner of display. 16 bit integer.

29

293

5

0 – 15

Reference Line #1Y Position

From upper left corner of display. 16 bit integer.

30

294

6

0 – 15

Reference Line #2X Position

From upper left corner of display. 16 bit integer.

31

295

7

0 – 15

Reference Line #2Y Position

From upper left corner of display. 16 bit integer.

32

296

8

0 – 15

Reference Line #3X Position

From upper left corner of display. 16 bit integer.

33

297

9

0 – 15

Reference Line #3Y Position

From upper left corner of display. 16 bit integer.

34

298

10

0 – 15

Reference Window #1X1 Position

Feature #1. From upper left corner. 16 bit integer.

35

299

11

0 – 15

Reference Window #1Y1 Position

Feature #1. From upper left corner. 16 bit integer.

36

300

12

0 – 15

Reference Window #1X2 Position

Feature #2. From upper left corner. 16 bit integer.

37

301

13

0 – 15

Reference Window #1Y2 Position

Feature #2. From upper left corner. 16 bit integer.

38

302

14

0 – 15

Reference Window #1X3 Position

Feature #3. From upper left corner. 16 bit integer.

39

303

15

0 – 15

Reference Window #1Y3 Position

Feature #3. From upper left corner. 16 bit integer.

40

304

16

0 – 15

Reference Window #1X–Center

Centroid of enabled feature. 16 bit integer.

41

305

17

0 – 15

Reference Window #1Y–Center

Centroid of enabled feature. 16 bit integer.

42

306

18

0 – 15

Reference Window #1 Theta Integer

16 . 16 value. Refer to Appendix A. Only if 2 or 3 Features are enabled.

43

307

19

0 – 15

Reference Window #1 Theta Faction

Only if 2 or 3 Features are enabled.

PI Backplane

Definition

Usage

Notes

C–3

Page 167

Appendix C Numerical Results Data

Results Block #1 (cont’d) Table C.1 Numerical Results Data – Results Block 1 Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

44

308

20

0

Reference Window #1X1/Y1 Pass/Fail Bit

0 = Pass 1 = Fail

Feature 1.

44

308

20

1

Reference Window #1X2/Y2 Pass/Fail Bit

0 = Pass 1 = Fail

Feature 2.

44

308

20

2

Reference Window #1X3/Y3 Pass/Fail Bit

0 = Pass 1 = Fail

Feature 3.

44

308

20

3

Combination Pass/Fail Bit

0 = Pass 1 = Fail

0 if all enabled features pass.

44

308

20

4 – 15

Not Used

45

309

21

0 – 15

Score Reference Window #1, Feature #1

46

310

22

0 – 15

Score Reference Window #1, Feature #2

47

311

23

0 – 15

Score Reference Window #1, Feature #3

PI Backplane

Definition

Usage

Notes

48 – 49

312 – 313

24 – 25

0 – 15

Window #1 Value

Luminance – 16 . 16 Object – 32 bit integer Pixel – 32 bit integer Template – 32 bit integer Gradient – 32 bit integer

50 – 51

314 – 315

26 – 27

0 – 15

Window #2 Value

Same as window #1.

52 – 53

316 – 317

28 – 29

0 – 15

Window #3 Value

Same as window #1.

54 – 55

318 – 319

30 – 31

0 – 15

Window #4 Value

Same as window #1.

56 – 57

320 – 321

32 – 33

0 – 15

Window #5 Value

Same as window #1.

58 – 59

322 – 323

34 – 35

0 – 15

Window #6 Value

Same as window #1.

60 – 61

324 – 325

36 – 37

0 – 15

Window #7 Value

Same as window #1.

62 – 63

326 – 327

38 – 39

0 – 15

Window #8 Value

Same as window #1.

C–4

Page 168

Appendix C Numerical Results Data

Table C.1 Numerical Results Data – Results Block 1 (cont’d) Word #

PI Backplane Toolset 1

Toolset 2

RS–232 and Remote I/O

Bit # Definition

Usage

Notes

64 – 65

328 – 329

40 – 41

0 – 15

Gage #1 Value

Angular & Linear Measure – 16 . 16 Edge – 32 bit integer Object – 32 bit integer Pixel – 32 bit integer X Position & Y Position – 16 . 16

66 – 67

330 – 331

42 – 43

0 – 15

Gage #2 Value

Same as Gage #1.

68 – 69

332 – 333

44 – 45

0 – 15

Gage #3 Value

Same as Gage #1.

70 – 71

334 – 335

46 – 47

0 – 15

Gage #4 Value

Same as Gage #1.

72 – 73

335 – 336

48 – 49

0 – 15

Gage #5 Value

Same as Gage #1.

74 – 75

337 – 338

50 – 51

0 – 15

Gage #6 Value

Same as Gage #1.

76 – 77

339 – 340

52 – 53

0 – 15

Gage #7 Value

Same as Gage #1.

78 – 79

341 – 342

54 – 55

0 – 15

Gage #8 Value

Same as Gage #1.

80

344

56

0 – 15

Reserved

81

345

57

0 – 15

Reserved

82

346

58

0 – 15

Reserved

83

347

59

0 – 15

Missed Triggers

84

348

60

0 – 15

Task Master Faults – Most Significant Word

85

349

61

0 – 15

Task Master Faults – Least Significant Word

86

350

62

0 – 15

Task Triggers – Most Significant Word

87

351

63

0 – 15

Task Triggers – Least Significant Word

32 bit integer. Value is incremented if at least one tool fails.

32 bit integer.

C–5

Page 169

Appendix C Numerical Results Data

Results Block #2

Table C.2 shows the function of each word in results block #2. Table C.2 Numerical Results Data – Results Block 2

Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

88

352

0

0 – 15

Block Transfer Signature

89

353

1

0 – 15

Reserved

PI Backplane

Definition

Usage

Notes

90 – 91

354 – 355

2–3

0 – 15

Window #9 Value

Luminance – 16 . 16 Object – 32 bit integer Pixel – 32 bit integer Template – 32 bit integer Gradient – 32 bit integer

92 – 93

356 – 357

4–5

0 – 15

Window #10 Value

Same as Window #9.

94 – 95

358 – 359

6–7

0 – 15

Window #11 Value

Same as Window #9.

96 – 97

360 – 361

8–9

0 – 15

Window #12 Value

Same as Window #9.

98 – 99

362 – 363

10 – 11

0 – 15

Window #13 Value

Same as Window #9.

100 – 101

364 – 365

12 – 13

0 – 15

Window #14 Value

Same as Window #9.

102 – 103

366 – 367

14 – 15

0 – 15

Window #15 Value

Same as Window #9.

104 – 105

368 – 369

16 – 17

0 – 15

Window #16 Value

Same as Window #9.

106 – 107

370 – 371

18 – 19

0 – 15

Gage #9 Value

Angular & Linear Measure – 16 . 16 Edge – 32 bit integer Object – 32 bit integer Pixel – 32 bit integer X Position & Y Position – 16 . 16

108 – 109

372 – 373

20 – 21

0 – 15

Gage #10 Value

Same as Gage #9.

110 – 111

374 – 375

22 – 23

0 – 15

Gage #11 Value

Same as Gage #9.

112 – 113

376 – 377

24 – 25

0 – 15

Gage #12 Value

Same as Gage #9.

114 – 115

378 – 379

26 – 27

0 – 15

Gage #13 Value

Same as Gage #9.

116 – 117

380 – 381

28 – 29

0 – 15

Gage #14 Value

Same as Gage #9.

118 – 119

382 – 383

30 – 31

0 – 15

Gage #15 Value

Same as Gage #9.

120 – 121

384 – 385

32 – 33

0 – 15

Gage #16 Value

Same as Gage #9.

122 – 123

386 – 387

34 – 35

0 – 15

Window #17 Value

Luminance – 16 . 16 Object – 32 bit integer Pixel – 32 bit integer Template – 32 bit integer Gradient – 32 bit integer

124 – 125

388 – 389

36 – 37

0 – 15

Window #18 Value

Same as Window #17.

126 – 127

390 – 391

38 – 39

0 – 15

Window #19 Value

Same as Window #17.

C–6

Page 170

Appendix C Numerical Results Data

Table C.2 Numerical Results Data – Results Block 2 Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

128 – 129

392 – 393

40 – 41

0 – 15

Window #20 Value

Same as Window #17.

130 – 131

394 – 395

42 – 43

0 – 15

Window #21 Value

Same as Window #17.

132 – 133

396 – 397

44 – 45

0 – 15

Window #22 Value

Same as Window #17.

134 – 135

398 – 399

46 – 47

0 – 15

Window #23 Value

Same as Window #17.

136 – 137

400 – 401

48 – 49

0 – 15

Window #24 Value

Same as Window #17.

PI Backplane

Definition

Usage

Notes

138 – 139

402 – 403

50 – 51

0 – 15

Gage #17 Value

Angular & Linear Measure – 16 . 16 Edge – 32 bit integer Object – 32 bit integer Pixel – 32 bit integer X Position & Y Position – 16 . 16

140 – 141

404 – 405

52 – 53

0 – 15

Gage #18 Value

Same as Gage #17.

142 – 143

406 – 407

54 – 55

0 – 15

Gage #19 Value

Same as Gage #17.

144 – 145

408 – 409

56 – 57

0 – 15

Gage #20 Value

Same as Gage #17.

146 – 147

410 – 411

58 – 59

0 – 15

Gage #21 Value

Same as Gage #17.

148 – 149

412 – 413

60 – 61

0 – 15

Gage #22 Value

Same as Gage #17.

150

414

62

0 – 15

Task Trigger – Most Significant Word

32 bit integer.

151

415

63

0 – 15

Task Trigger – Least Significant Word

C–7

Page 171

Appendix C Numerical Results Data

Results Block #3

Table C.3 shows the function of each word in results block #3. Table C.3 Numerical Results Data – Results Block 3

Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

152

416

0

0 – 15

Block Transfer Signature

153

417

1

0 – 15

Reserved

PI Backplane

Definition

Usage

Notes

154 – 155

418 – 419

2–3

0 – 15

Gage #23 Value

Angular & Linear Measure – 16 . 16 Edge – 32 bit integer Object – 32 bit integer Pixel – 32 bit integer X Position & Y Position – 16 . 16

156 – 157

420 – 421

4–5

0 – 15

Gage #24 Value

Same as Gage #23

158 – 159

422 – 423

6–7

0 – 15

Gage #25 Value

Same as Gage #23

160 – 161

424 – 425

8–9

0 – 15

Gage #26 Value

Same as Gage #23

162 – 163

426 – 427

10 – 11

0 – 15

Gage #27 Value

Same as Gage #23

164 – 165

428 – 429

12 – 13

0 – 15

Gage #28 Value

Same as Gage #23

166 – 167

430 – 431

14 – 15

0 – 15

Gage #29 Value

Same as Gage #23

168 – 169

432 – 433

16 – 17

0 – 15

Gage #30 Value

Same as Gage #23

170 – 171

434 – 435

18 – 19

0 – 15

Gage #31 Value

Same as Gage #23

172 – 173

436 – 437

20 – 21

0 – 15

Gage #32 Value

Same as Gage #23 Feature #1 16 bit integer

C–8

174

438

22

0 – 15

Reference Window #2X1 Position

175

439

23

0 – 15

Reference Window #2Y1 Position

Feature #1 16 bit integer

176

440

24

0 – 15

Reference Window #2X2 Position

Feature #2 16 bit integer

177

441

25

0 – 15

Reference Window #2Y2 Position

Feature #2 16 bit integer

178

442

26

0 – 15

Reference Window #2X3 Position

Feature #3 16 bit integer

179

443

27

0 – 15

Reference Window #2Y3 Position

Feature #3 16 bit integer

180

444

28

0 – 15

Reference Window #2X – Center

Centroid of enabled feature. 16 bit integer.

181

445

29

0 – 15

Reference Window #2Y – Center

Centroid of enabled feature. 16 bit integer.