Appendix C Numerical Results Data

Table C.3 Numerical Results Data – Results Block 3 Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

182

446

30

0 – 15

Reference Window #2 Theta (Integer)

16 . 16 value. Refer to Appendix A. Only if 2 or 3 features are enabled.

183

447

31

0 – 15

Reference Window #2 (Fraction)

Only if 2 or 3 features are enabled.

184

448

32

0

Reference Window #2X1/Y1 Pass/Fail Bit

0 = Pass 1 = Fail

Feature #1.

184

448

32

1

Reference Window #2X2/Y2 Pass/Fail Bit

0 = Pass 1 = Fail

Feature #2.

184

448

32

2

Reference Window #2X3/Y3 Pass/Fail Bit

0 = Pass 1 = Fail

Feature #3.

184

448

32

3

Combination Pass/Fail Bit

0 = Pass 1 = Fail

0 if all enabled features pass.

184

448

32

4 – 15

Not Used

PI Backplane

Definition

Usage

Notes

185

449

33

0 – 15

Score Reference Window #2, Feature #1

186

450

34

0 – 15

Score Reference Window #2, Feature #2

187

451

35

0 – 15

Score Reference Window #2, Feature #3

188

452

36

0 – 15

Reference Window #3X1 Position

Feature #1 16 bit integer.

189

453

37

0 – 15

Reference Window #3Y1 Position

Feature #1 16 bit integer.

190

454

38

0 – 15

Reference Window #3X2 Position

Feature #2 16 bit integer.

191

455

39

0 – 15

Reference Window #3Y2 Position

Feature #2 16 bit integer.

192

456

40

0 – 15

Reference Window #3X3 Position

Feature #3 16 bit integer.

193

457

41

0 – 15

Reference Window #3Y3 Position

Feature #3 16 bit integer.

C–9

Page 173

Appendix C Numerical Results Data

Results Block #3 (cont’d) Table C.3 Numerical Results Data – Results Block 3 Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

194

458

42

0 – 15

Reference Window #3X – Center

Centroid of enabled feature. 16 bit integer.

195

459

43

0 – 15

Reference Window #3Y – Center

Centroid of enabled feature. 16 bit integer.

196

460

44

0 – 15

Reference Window #3 Theta (Integer)

16 . 16 value. Refer to Appendix A. Only if 2 or 3 Features are enabled.

197

461

45

0 – 15

Reference Window #3 (Fraction)

Only if 2 or 3 Features are enabled.

198

462

46

0

Reference Window X1/Y1 Pass/Fail Bit

0 = Pass 1 = Fail

Feature #1 16 bit integer.

198

462

46

1

Reference Window X2/Y2 Pass/Fail Bit

0 = Pass 1 = Fail

Feature #2 16 bit integer.

198

462

46

2

Reference Window X3/Y3 Pass/Fail Bit

0 = Pass 1 = Fail

Feature #3 16 bit integer.

198

462

46

3

Combination Pass/Fail Bit

0 = Pass 1 = Fail

0 if all enabled tools pass.

198

462

46

4 – 15

Not Used

199

463

47

0 – 15

Score Reference Window #3, Feature #1

200

464

48

0 – 15

Score Reference Window #3, Feature #2

201

465

49

0 – 15

Score Reference Window #3, Feature #3

202 – 209

466 – 473

50 – 57

0 – 15

Reserved

210

474

58

0 – 15

Reserved

211

475

59

0 – 15

Task Missed Triggers

212

476

60

0 – 15

Task Masters Faults – Most Significant Word

PI Backplane

C–10

Definition

Usage

Notes

16 bit integer. 32 bit integer. Increments if at least 1 tool fails.

Page 174

Appendix C Numerical Results Data

Table C.3 Numerical Results Data – Results Block 3 Word # Bit #

Toolset 1

Toolset 2

RS–232 and Remote I/O

213

477

61

0 – 15

Task Master Faults – Least Significant Word

214

478

62

0 – 15

Task Triggers – Most Significant Word

215

479

63

0 – 15

Task Triggers – Least Significant Word

PI Backplane

Definition

Usage

Notes

32 bit integer. Refer to Appendix A.

C–11

Page 175

Appendix C Numerical Results Data

Results Block #4

The fourth results block may be formatted and read through any of the communications ports. This block has user defined contents. This block may contain up to 64 words of data; see Table C.4. Table C.4 Numerical Results Data – Results Block #4

Word #

Bit #

Function

0

0 – 15

Block Transfer Signature

1

0 – 15

Status

2 – 61

0 – 15

User Defined Inspection Results Data

62 – 63

0 – 15

Task Triggers (32 Bits)

Notes The contents of this word will be 0 if all of the requested data fits in the 64 word results block. Otherwise, the contents will be non–0.

Each type of result requires a specific number of words. Use the following as a guideline when setting up a programmable block transfer. Number of Words Module Status

1 Word

X/Y Reference Line

2 Words

Window

2 Words

Format 16 Bit Integer

(Object & Pixel)

32 Bit Integer

(Luminance)

16 Point 16

(Template)

32 Bit Integer

(Gradient)

32 Bit Integer

Brightness Probe

2 Words

16 Point 16

Reference Window

14 Words

16 Bit Integer and 16 Point 16

Gage

2 Words (Linear Measure)

16 Point 16

(Edge, Pixel, Object)

32 Bit Integer

X, Y Position

16 Point 16

If you request more results than will fit into 62 words, the CVIM will truncate the data and set an error bit in word 1. Note: Refer to discrete output word description (word 3) on Page 4 – 18 for information on how to send a programmable block format request to the CVIM. C–12

Page 176

Appendix C Numerical Results Data

Note: Words 2 through 5 select tools for Toolset 1. Words 6 through 9 select tools for Toolset 2. Note: Word 0, block signature and word 1 are not used. Use Table C.5 to set the contents of the programmable results block and statistics block. Table C.5 Programmable Results/Statistics Block Configuration 1771 Node Adapter Results or Statistics Word # Toolset 1

Word # Toolset 2

Bit #

2

6

0

2

6

2

6

2

RS–232 Results or Statistics Function

Byte # Toolset 1

Byte # Toolset 2

Bit #

Module Status (NA for statistics)

0

8

0

1

Light Probe

0

8

1

2

Reference Line 1 (NA for statistics)

0

8

2

6

3

Reference Line 2 (NA for statistics)

0

8

3

2

6

4

Reference Line 3 (NA for statistics)

0

8

4

2

6

5

Reference Window 1

0

8

5

2

6

6

Reference Window 2

0

8

6

2

6

7

Reference Window 3

0

8

7

2

6

8

Window 1

1

9

0

2

6

9

Window 2

1

9

1

2

6

10

Window 3

1

9

2

2

6

11

Window 4

1

9

3

2

6

12

Window 5

1

9

4

2

6

13

Window 6

1

9

5

2

6

14

Window 7

1

9

6

2

6

15

Window 8

1

9

7

3

7

0

Window 9

2

10

0

3

7

1

Window 10

2

10

1

3

7

2

Window 11

2

10

2

3

7

3

Window 12

2

10

3

3

7

4

Window 13

2

10

4

3

7

5

Window 14

2

10

5

3

7

6

Window 15

2

10

6

3

7

7

Window 16

2

10

7

3

7

8

Window 17

3

11

0

3

7

9

Window 18

3

11

1

3

7

10

Window 19

3

11

2

3

7

11

Window 20

3

11

3 C–13

Page 177

Appendix C Numerical Results Data

Results Block #4 (cont’d) Table C.5 Programmable Results/Statistics Block Configuration 1771 Node Adapter Results or Statistics Word # Toolset 1

Word # Toolset 2

Bit #

3

7

12

3

7

3

C–14

RS–232 Results or Statistics Function

Byte # Toolset 1

Byte # Toolset 2

Bit #

Window 21

3

11

4

13

Window 22

3

11

5

7

14

Window 23

3

11

6

3

7

15

Window 24

3

11

7

4

8

0

Gage 1

4

12

0

4

8

1

Gage 2

4

12

1

4

8

2

Gage 3

4

12

2

4

8

3

Gage 4

4

12

3

4

8

4

Gage 5

4

12

4

4

8

5

Gage 6

5

13

5

4

8

6

Gage 7

5

13

6

4

8

7

Gage 8

5

13

7

4

8

8

Gage 9

5

13

0

4

8

9

Gage 10

5

13

1

4

8

10

Gage 11

5

13

2

4

8

11

Gage 12

5

13

3

4

8

12

Gage 13

5

13

4

4

8

13

Gage 14

5

13

5

4

8

14

Gage 15

5

13

6

4

8

15

Gage 16

5

13

7

5

9

0

Gage 17

6

14

0

5

9

1

Gage 18

6

14

1

5

9

2

Gage 19

6

14

2

5

9

3

Gage 20

6

14

3

5

9

4

Gage 21

6

14

4

5

9

5

Gage 22

6

14

5

5

9

6

Gage 23

6

14

6

5

9

7

Gage 24

6

14

7

5

9

8

Gage 25

7

15

0

5

9

9

Gage 26

7

15

1

5

9

10

Gage 27

7

15

2

Page 178

Appendix C Numerical Results Data

Table C.5 Programmable Results/Statistics Block Configuration 1771 Node Adapter Results or Statistics Word # Toolset 1

Word # Toolset 2

Bit #

5

9

11

5

9

5

RS–232 Results or Statistics Function

Byte # Toolset 1

Byte # Toolset 2

Bit #

Gage 28

7

15

3

12

Gage 29

7

15

4

9

13

Gage 30

7

15

5

5

9

14

Gage 31

7

15

6

5

9

15

Gage 32

7

15

7

C–15

Page 179

Appendix C Numerical Results Data

Statistics Block

The Statistics Block can be formatted and read through any of the communications ports. The Statistics Block has user defined contents. This block may contain up to 64 words of data; see Table C.6. Table C.6 Statistics Block

Word #

Bit #

Function

0

0 – 15

Block Transfer Signature

1 – 63

0 – 15

User Defined Statistics Data

Notes

Each type of statistic requires a specific number of words. Use the following as a guideline when setting up a programmable block transfer. Block Signature Number of Samples Minimum and Maximum Window (Object and Pixel) Window (Luminance) Widow (Template) Brightness Probe Reference Window Gage (Linear Measure) Gage (Edge, Pixel, Object)

= 1 Word = 1 Word (2 Byte Integer) = 4 Bytes 32 Bit Integer 16 Point 16 32 Bit Integer 16 Point 16 16 Bit Integer & 16 Point 16 16 Point 16 32 Bit Integer

Average

= 4 Bytes (16 Point 16 for fixed point values)

Standard Deviation

= 4 Bytes (16 Point 16)

Each tool statistic consists of 18 bytes with the exception of reference windows which contain 18 bytes for each feature or a total of 54 bytes. The statistics block is transmitted as two hexadecimal characters for each byte. The total number of bytes including the block signature should not exceed 128 bytes.

C–16