Page 180

Appendix

D

Configuration Data Configuration Block Overview

There are 135 configuration blocks. The following is an overview of the blocks. Block Number 1 . . . . . . . . . . . . . . . . . . System Environment (45 words). Block Numbers 2 and 3 . . . . . . . . . . . . Camera A and B Definition (61 words each camera). Block Numbers 4 through 6 . . . . . . . . . Toolset 1 Reference Lines 1 through 3 (30 words). Block Numbers 7 through 9 . . . . . . . . . Toolset 1 Reference Windows 1 through 3 (36 words). Block Number 10 through 41 . . . . . . . . Toolset 1 Gages 1 through 32 (28 words). Block Numbers 42 through 65 . . . . . . . Toolset 1 Windows 1 through 24 (37 words). Block Numbers 66 through 68 . . . . . . . Toolset 2 Reference Lines 1 through 3 (30 words). Block Numbers 69 through 71 . . . . . . . Toolset 2 Reference Windows 1 through 3 (36 words). Block Numbers 72 through 103 . . . . . . Toolset 2 Gages 1 through 32 (28 words). Block Numbers 104 through 127 . . . . . Toolset 2 Windows 1 through 24 (37 words). Block Numbers 128 through 135 . . . . . Polygon Blocks 1 through 8 (37 words). Note: When reading the configuration blocks, the PLC should set the block length to 0. This will allow the CVIM module to set the block size based upon the block number received. The CVIM module will then only send the amount of data required for each block type. This helps reduce the overall transfer time when writing. If the PLC sets the block length to 0 (64 words) when writing to a CVIM module, the CVIM module will ignore excess data at the end of each block. Alternatively, the PLC may set the exact length to reduce the transfer time.

D–1

Page 181

Appendix D Configuration Data

Configuration Block #1

Table D.1 shows the function of each word in the system environment configuration block. Table D.1 Configuration Block #1– System Environment

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1–3

0–15

Reserved

4

0–7

Configuration ID (Char. 2)

4

8–15

Configuration ID (Char. 1)

5

0–7

Configuration ID (Char. 4)

5

8–15

Configuration ID (Char. 3)

6

0–7

Configuration ID (Char. 6)

6

8–15

Configuration ID (Char. 5)

7

0–7

Configuration ID (Char. 8)

7

8–15

Configuration ID (Char. 7)

8

0–7

Configuration ID (Char. 10)

8

8–15

Configuration ID (Char. 9)

9

0–7

Configuration ID (Char. 12)

9

8–15

Configuration ID (Char. 11)

10

0–7

Configuration ID (Char. 14)

10

8–15

Configuration ID (Char. 13)

11

0–7

Configuration ID (Char. 16)

11

8–15

Configuration ID (Char. 15)

12

0–15

Reserved

13

0

Monitor Type

0 = B/W 1 = Color

13

1

Remote I/O Enable

0 = Disabled 1 = Enabled

13

2&4

Protocol–Port A

0 = ASCII 1 = DF1 2 = Not Specified 3 = Not Specified

13

3

Host Standby Mode

0 = Standby Enabled 1 = Standby Disabled

13

5&6

Protocol–Port B

0 = ASCII 1 = DF1 2 = Not Specified 3 = Not Specified

13

7–15

Reserved

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–2

Usage

Notes

Port A, see bits 5 & 6 for port B.

Port B, see bits 2 & 4 for port A.

Page 182

Appendix D Configuration Data

Table D.1 Configuration Block #1– System Environment (cont’d) Remote I/O & RS–232 Word #*

Bit #

14–15

0–15

Reserved

16

0–7

Toolset Display Status

16

8–15

Reserved

17

0–7

Reserved

17

8

Learn Mode

0 = Disabled 1 = Enabled

17

9

Outputs Enable

0 = Disabled 1 = Enabled

17

10

Freeze Enable

0 = Disabled 1 = Enabled

17

11

Halt Enable

0 = Disabled 1 = Enabled

17

12–15

Runtime Toolset Display

0 = Toolset 1 1 = Toolset 2

18–31

0–15

Reserved

32

0–15

Toolset 1 Pulse Width

In milliseconds.

33

0–15

Toolset 2 Pulse Width

In milliseconds.

34–44

0–15

Reserved

Definition

Usage

0 = Disabled 1 = Enabled

Notes

All tools appear simultaneously while setting a given tool.

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–3

Page 183

Appendix D Configuration Data

Configuration Blocks 2 & 3

Tables D.2 shows the function of each word in the camera definition configuration blocks. Table D.2 Configuration Block #2 & 3 – Camera Definition

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1

0–7

Camera Low Reference

0 = Minimum Value ... 100 = Maximum Value

These values do not correspond with the display on the help screen.

1

8–15

Camera High Reference

105 = Minimum Value ... 255 = Maximum Value

These values do not correspond with the display on the help screen.

2

0–7

Light Probe Status

0 = Disabled 1 = Same Field 2 = Next Field

2

8–15

Reserved

3

0–15

Light Probe X Location

16 = Minimum Value ... 504 = Maximum Value

4

0–15

Light Probe Y Location

8 = Minimum Value ... 232 = Maximum Value

5–9

0–15

Reserved

10

0–15

Fail Range High (Integer)

11

0–15

Fail Range High (Fraction)

12

0–15

Fail Range Low (Integer)

13

0–15

Fail Range Low (Fraction)

14

0–15

Warning Range High (Integer)

15

0–15

Warning Range High (Fraction)

16

0–15

Warning Range Low (Integer)

17

0–15

Warning Range Low (Fraction)

18–60

0–15

Reserved

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–4

Usage

Notes

Words 10 and 11 represent a 16 (bit) . 16 (bit) fixed point decimal value. Words 12 and 13 represent a 16(bit) . 16(bit) fixed point decimal value. Words 14 and 15 represent a 16 (bit). 16 (bit) fixed point decimal value. Words 16 and 17 represent a 16 (bit) . 16 (bit) fixed point decimal value.

Page 184

Appendix D Configuration Data

Configuration Blocks 4–6

Tables D.3 shows the function of each word in the reference line 1–3 (Toolset 1) configuration blocks. Table D.3 Configuration Blocks #4–6 – Reference Lines 1–3 (Toolset 1)

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1

0–7

Reserved

1

8

Enable

1

9–15

Reserved

2–7

0–15

Reserved

8

0–7

X–Line Low Threshold/Gray Scale Factor

0 – 63 0 – 39

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

8

8–15

X–Line High Threshold/Gradient Threshold

0 – 63 0 – 197

If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

9

0–15

Reserved

10

0–15

X–Line Head X Position

From upper left corner.

11

0–15

X–Line Head Y Position

From upper left corner.

12

0–15

X–Line Tail X Position

From upper left corner.

13

0–15

X–Line Tail Y Position

From upper left corner.

14

0–15

Reserved

15

0–7

Y–Line Low Threshold/Gray Scale Factor

0 – 63 0 – 39

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

15

8–15

Y–Line High Threshold/Gradient Threshold

0 – 63 0 – 197

If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

16

0–15

Reserved

17

0–15

Y–Line Head X Position

From upper left corner.

18

0–15

Y–Line Head Y Position

From upper left corner.

19

0–15

Y–Line Tail X Position

From upper left corner.

20

0–15

Y–Line Tail Y Position

From upper left corner.

21

0–15

Reserved

22

0–7

X/Y–Line Low Threshold/Gray Scale Factor

0 – 63 0 – 39

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

22

8–15

X/Y–Line High Threshold/Gradient Threshold

0 – 63 0 – 197

If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

Usage

Notes

0 = Disabled 1 = Enabled

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–5

Page 185

Appendix D Configuration Data

Configuration Blocks 4 – 6 (cont’d)

Table D.3 Configuration Blocks #4–6 – Reference Lines 1–3 (Toolset 1) continued

Remote I/O & RS–232 Word #*

Bit #

23

0–15

Reserved

24

0–15

X/Y–Line Head X Position

From upper left corner.

25

0–15

X/Y–Line Head Y Position

From upper left corner.

26

0–15

X/Y–Line Tail X Position

From upper left corner.

27

0–15

X/Y–Line Tail Y Position

From upper left corner.

28–29

0–15

Reserved

Definition

Usage

Notes

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

Configuration Blocks 7 – 9

Table D.4 shows the function of each word in the reference window 1–3 (Toolset 1) configuration blocks. Table D.4 Configuration Blocks #7–9 – Reference Windows 1–3 (Toolset 1)

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1

0–7

Reserved

1

8

Enable

1

9–15

Reserved

2–7

0–15

Reserved

8

0–15

Feature 1 Search Window X Location

Relative to the upper left corner.

9

0–15

Feature 1 Search Window Y Location

Relative to the upper left corner.

10

0–15

Feature 1 Search Window Width

11

0–15

Feature 1 Search Window Height

12–15

0–15

Reserved

16

0–7

Reserved

16

8–15

Feature 1 Score

17

0–15

Feature 2 Search Window X Location

Relative to the upper left corner.

18

0–15

Feature 2 Search Window Y Location

Relative to the upper left corner.

19

0–15

Feature 2 Search Window Width

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–6

Usage

Notes

0 = Disabled 1 = Enabled

0 = Minimum Value 255 = Maximum Value

Page 186

Appendix D Configuration Data

Table D.4 Configuration Blocks #7–9 – Reference Windows 1–3 (Toolset 1) Remote I/O & RS–232 Word #*

Bit #

Definition

20

0–15

Feature 2 Search Window Height

21–24

0–15

Reserved

25

0–7

Reserved

25

8–15

Feature 2 Score

26

0–15

Feature 3 Search Window X Location

Relative to the upper left corner.

27

0–15

Feature 3 Search Window Y Location

Relative to the upper left corner.

28

0–15

Feature 3 Search Window Width

29

0–15

Feature 3 Search Window Height

30–33

0–15

Reserved

34

0–7

Reserved

34–35

8–15

Feature 3 Score

Usage

Notes

0 = Minimum Value 255 = Maximum Value

0 = Minimum Value 255 = Maximum Value

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

Configuration Blocks 10 – 41

Table D.5 shows the function of each word in the gage 1–32 (Toolset 1) configuration blocks. Table D.5 Configuration Blocks #10–41 – Gages 1–32 (Toolset 1)

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1

0

Enable

1

1–15

Reserved

2–3

0–15

Reserved

4

0–7

Low Threshold/Gray Scale Factor

Usage

Notes

0 = Disabled 1 = Enabled

0 – 63 0 – 197

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–7

Page 187

Appendix D Configuration Data

Configuration Blocks 10 – 41 (cont’d) Table D.5 Configuration Blocks #10–41 – Gages 1–32 (Toolset 1) Remote I/O & RS–232 Word #*

Bit #

Definition

4

8–15

High Threshold/Gradient Threshold

5

0–15

Reserved

6

0–15

Gage Head X Position

7

0–15

Gage Head Y Position

8

0–15

Gage Tail X Position

9

0–15

Gage Tail Y Position

10

0–15

Gage X Center Position (Circular Gage)

11

0–15

Gage Y Center Position (Circular Gage)

12

0–15

Radius of Circular Gage

13–16

0–15

Reserved

17

0–15

Fail Range High (Integer)

18

0–15

Fail Range High (Fraction)

19

0–15

Fail Range Low (Integer)

20

0–15

Fail Range Low (Fraction)

21

0–15

Warning Range High (Integer)

22

0–15

Warning Range High (Fraction)

23

0–15

Warning Range Low (Integer)

24

0–15

Warning Range Low (Fraction)

25–27

0–15

Reserved

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–8

Usage 0 – 63 0 – 197

Notes If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

Words 17 and 18 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 19 and 20 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 21 and 22 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 23 and 24 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.

Page 188

Appendix D Configuration Data

Configuration Blocks 42 – 65

Table D.6 shows the function of each word in the window 1–24 (Toolset 1) configuration blocks. Table D.6 Configuration Blocks #42–65 – Windows 1–24 (Toolset 1)

Remote I/O & RS–232 Word #

Bit #

Definition

0

0–15

Block Transfer Signature

1

0

Enable

1

1–15

Reserved

2–4

0–15

Reserved

5

0– 7

Window Low Threshold

0 = Low Limit ... 63 = High Limit

5

8–15

Window High Threshold

0 = Low Limit ... 63 = High Limit

6–10

0–15

Reserved

11

0–15

Window X Location (Bounding Box)

12

0–15

Window Y Location (Bounding Box)

13

0–15

Window Width (Bounding Box)

14

0–15

Window Height (Bounding Box)

15

0–15

Mask X Location (Bounding Box)

16

0–15

Mask Y Location (Bounding Box)

17

0–15

Mask Width (Bounding Box)

18

0–15

Mask Height (Bounding Box)

19–27

0–15

Reserved

28

0–15

Fail Range High (Integer)

29

0–15

Fail Range High (Fraction)

30

0–15

Fail Range Low (Integer)

31

0–15

Fail Range Low (Fraction)

32

0–15

Warning Range High (Integer)

33

0–15

Warning Range High (Fraction)

34

0–15

Warning Range Low (Integer)

35–36

0–15

Warning Range Low (Fraction)

Usage

Notes

0 = Disabled 1 = Enabled

Words 28 and 29 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 30 and 31 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 32 and 33 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 34 and 35 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–9

Page 189

Appendix D Configuration Data

Configuration Blocks 66 – 68

Table D.7 shows the function of each word in the reference line 1–3 (Toolset 2) configuration blocks. Table D.7 Configuration Blocks #66–68 – Reference Lines 1–3 (Toolset 2)

Remote I/O & RS–232 Word #

Bit #

Definition

0

0–15

Block Transfer Signature

1

0–7

Reserved

1

8

Enabled

1

9–15

Reserved

2–7

0–15

Reserved

8

0–7

X–Line Low Threshold/Gray Scale Factor

0 – 63 0 – 39

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

8

8–15

X–Line High Threshold/Gradient Threshold

0 – 63 0 – 197

If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

9

0–15

Reserved

10

0–15

X–Line Head X Position

From upper left corner.

11

0–15

X–Line Head Y Position

From upper left corner.

12

0–15

X–Line Tail X Position

From upper left corner.

13

0–15

X–Line Tail Y Position

From upper left corner.

14

0–15

Reserved

15

0–7

Y–Line Low Threshold/Gray Scale Factor

0 – 63 0 – 39

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

15

8–15

Y–Line High Threshold/Gradient Threshold

0 – 63 0 – 197

If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

16

0–15

Reserved

17

0–15

Y–Line Head X Position

From upper left corner.

18

0–15

Y–Line Head Y Position

From upper left corner.

19

0–15

Y–Line Tail X Position

From upper left corner.

20

0–15

Y–Line Tail Y Position

From upper left corner.

21

0–15

Reserved

22

0–7

X/Y–Line Low Threshold/Gray Scale Factor

0 – 63 0 – 39

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

22

8–15

X/Y–Line High Threshold/ Gradient Threshold

0–63 0 – 197

If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–10

Usage

Notes

0 = Disabled 1 = Enabled

Page 190

Appendix D Configuration Data

Table D.7 Configuration Blocks #37–39 – Reference Lines 1–3 (Toolset 2) Remote I/O & RS–232 Word #

Bit #

23

0–15

Reserved

24

0–15

X/Y–Line Head X Position

From upper left corner.

25

0–15

X/Y–Line Head Y Position

From upper left corner.

26

0–15

X/Y–Line Tail X Position

From upper left corner.

27

0–15

X/Y–Line Tail Y Position

From upper left corner.

28–29

0–15

Reserved

Definition

Usage

Notes

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

Configuration Blocks 69–71

Table D.8 shows the function of each word in the reference window 1–3 (Toolset 2) configuration blocks. Table D.8 Configuration Blocks #69–71 – Reference Windows 1–3 (Toolset 2)

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1

0–7

Reserved

1

8

Enable

1

9–15

Reserved

2–7

0– 15

Reserved

8

0– 15

Feature 1 Search Window X Location

Relative to the upper left corner.

9

0– 15

Feature 1 Search Window Y Location

Relative to the upper left corner.

10

0– 15

Feature 1 Search Window Width

11

0– 15

Feature 1 Search Window Height

12–15

0–15

Reserved

16

0–7

Reserved

16

8–15

Feature 1 Score

17

0–15

Feature 2 Search Window X Location

Relative to the upper left corner.

18

0–15

Feature 2 Search Window Y Location

Relative to the upper left corner.

Usage

Notes

0 = Disabled 1 = Enabled

0 = Minimum Value 255 = Maximum Value

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–11

Page 191

Appendix D Configuration Data

Configuration Blocks 69–71 (cont’d) Table D.8 Configuration Blocks #69–71 – Reference Windows 1–3 (Toolset 2) Remote I/O & RS–232 Word #*

Bit #

Definition

19

0–15

Feature 2 Search Window Width

20

0–15

Feature 2 Search Window Height

21–24

0–15

Reserved

25

0–7

Reserved

25

8–15

Feature 2 Score

26

0–15

Feature 3 Search Window X Location

Relative to the upper left corner.

27

0–15

Feature 3 Search Window Y Location

Relative to the upper left corner.

28

0–15

Feature 3 Search Window Width

Usage

Notes

0 = Minimum Value 255 = Maximum Value

29

0–15

Feature 3 Search Window Height

30–33

0–15

Reserved

34

0–7

Reserved

34–35

8–15

Feature 3 Score

0 = Minimum Value 255 = Maximum Value

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

Configuration Blocks 72–103

Table D.9 shows the function of each word in the gage 1–32 (Toolset 2) configuration blocks. Table D.9 Configuration Blocks #72–103 – Gages 1–32 (Toolset 2)

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1

0

Enable

1

1–15

Reserved

2–3

0–15

Reserved

4

0–7

Low Threshold/Gray Scale Factor

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–12

Usage

Notes

0 = Disabled 1 = Enabled

0 – 63 0 – 39

If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.

Page 192

Appendix D Configuration Data

Table D.9 Configuration Blocks #72–103 – Gages 1–32 (Toolset 2) Remote I/O & RS–232 Word #*

Bit #

Definition

4

8–15

High Threshold/Gradient Threshold

5

0–15

Reserved

6

0–15

Gage Head X Position

7

0–15

Gage Head Y Position

8

0–15

Gage Tail X Position

9

0–15

Gage Tail Y Position

10

0–15

Gage X Center Position (Circular Gage)

11

0–15

Gage Y Center Position (Circular Gage)

12

0–15

Radius of Circular Gage

13–16

0–15

Reserved

17

0–15

Fail Range High (Integer)

18

0–15

Fail Range High (Fraction)

19

0–15

Fail Range Low (Integer)

20

0–15

Fail Range Low (Fraction)

21

0–15

Warning Range High (Integer)

22

0–15

Warning Range High (Fraction)

23

0–15

Warning Range Low (Integer)

24

0–15

Warning Range Low (Fraction)

25–27

0–15

Reserved

Usage 0 – 63 0 – 197

Notes If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.

Words 17 and 18 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 19 and 20 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 21 and 22 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 23 and 24 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–13

Page 193

Appendix D Configuration Data

Configuration Blocks 104–127

Table D.10 shows the function of each word in the window 1–24 (Toolset 2) configuration blocks. Table D.10 Configuration Blocks #104–127 – Windows 1–24 (Toolset 2)

Remote I/O & RS–232 Word #*

Bit #

Definition

0

0–15

Block Transfer Signature

1

0

Enable

1

1–15

Reserved

2–4

0–15

Reserved

5

0–7

Window Low Threshold

0 = Low Limit ... 63 = High Limit

5

8–15

Window High Threshold

0 = Low Limit ... 63 = High Limit

6–10

0–15

Reserved

11

0–15

Window X Location (Bounding Box)

12

0–15

Window Y Location (Bounding Box)

13

0–15

Window Width (Bounding Box)

14

0–15

Window Height (Bounding Box)

15

0–15

Mask X Location (Bounding Box)

16

0–15

Mask Y Location (Bounding Box)

17

0–15

Mask Width (Bounding Box)

18

0–15

Mask Height (Bounding Box)

19–27

0–15

Reserved

28

0–15

Fail Range High (Integer)

29

0–15

Fail Range High (Fraction)

30

0–15

Fail Range Low (Integer)

31

0–15

Fail Range Low (Fraction)

32

0–15

Warning Range High (Integer)

33

0–15

Warning Range High (Fraction)

34

0–15

Warning Range Low (Integer)

35–36

0–15

Warning Range Low (Fraction)

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

D–14

Usage

Notes

0 = Disabled 1 = Enabled

Words 28 and 29 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 30 and 31 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 32 and 33 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 34 and 35 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.

Page 194

Appendix D Configuration Data

Configuration Blocks 128–135

Table D.11 shows the function of each word in the polygon configuration blocks. Table D.11 Polygon Configuration Blocks #128–135

Remote I/O & RS–232 Word #*

Bit #

Definition

1

0–15

Block Transfer Signature

2–36

0–15

Reserved

Usage

Notes

* Refer to Chapter 6 for Pyramid Integrator long word descriptions.

Template Blocks 136–

The template blocks begin at block #136. The number of template blocks stored in memory is variable. Word 1, bits 8–15 (third byte sent using RS–232) of the first template block indicate the total number of template blocks in the configuration. You must always upload or download all of the template blocks as a unit. You cannot archive only a part of the template blocks. When uploading templates from the CVIM module, the program should read the first template block and check word 1, bits 8–15 (third byte sent using RS–232) to determine the number of template blocks to follow. The number of blocks remaining is then 1 less than the total number of template blocks. When downloading templates to the CVIM module, the program must send all template blocks. Bits 8–15 of word 1 determine the number of blocks to send.

D–15