The text of a manual · part 23 of 25
Bulletin 5370 CVIM Configurable Vision Input Module Communications Manual: D - Configuration Data
Pages 180 to 194 of 202, from Bulletin 5370 CVIM Configurable Vision Input Module Communications Manual
The original document is the PDF (723 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 5370-CVIM
Page 180
Appendix
D
Configuration Data Configuration Block Overview
There are 135 configuration blocks. The following is an overview of the blocks. Block Number 1 . . . . . . . . . . . . . . . . . . System Environment (45 words). Block Numbers 2 and 3 . . . . . . . . . . . . Camera A and B Definition (61 words each camera). Block Numbers 4 through 6 . . . . . . . . . Toolset 1 Reference Lines 1 through 3 (30 words). Block Numbers 7 through 9 . . . . . . . . . Toolset 1 Reference Windows 1 through 3 (36 words). Block Number 10 through 41 . . . . . . . . Toolset 1 Gages 1 through 32 (28 words). Block Numbers 42 through 65 . . . . . . . Toolset 1 Windows 1 through 24 (37 words). Block Numbers 66 through 68 . . . . . . . Toolset 2 Reference Lines 1 through 3 (30 words). Block Numbers 69 through 71 . . . . . . . Toolset 2 Reference Windows 1 through 3 (36 words). Block Numbers 72 through 103 . . . . . . Toolset 2 Gages 1 through 32 (28 words). Block Numbers 104 through 127 . . . . . Toolset 2 Windows 1 through 24 (37 words). Block Numbers 128 through 135 . . . . . Polygon Blocks 1 through 8 (37 words). Note: When reading the configuration blocks, the PLC should set the block length to 0. This will allow the CVIM module to set the block size based upon the block number received. The CVIM module will then only send the amount of data required for each block type. This helps reduce the overall transfer time when writing. If the PLC sets the block length to 0 (64 words) when writing to a CVIM module, the CVIM module will ignore excess data at the end of each block. Alternatively, the PLC may set the exact length to reduce the transfer time.
D–1
Page 181
Appendix D Configuration Data
Configuration Block #1
Table D.1 shows the function of each word in the system environment configuration block. Table D.1 Configuration Block #1– System Environment
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1–3
0–15
Reserved
4
0–7
Configuration ID (Char. 2)
4
8–15
Configuration ID (Char. 1)
5
0–7
Configuration ID (Char. 4)
5
8–15
Configuration ID (Char. 3)
6
0–7
Configuration ID (Char. 6)
6
8–15
Configuration ID (Char. 5)
7
0–7
Configuration ID (Char. 8)
7
8–15
Configuration ID (Char. 7)
8
0–7
Configuration ID (Char. 10)
8
8–15
Configuration ID (Char. 9)
9
0–7
Configuration ID (Char. 12)
9
8–15
Configuration ID (Char. 11)
10
0–7
Configuration ID (Char. 14)
10
8–15
Configuration ID (Char. 13)
11
0–7
Configuration ID (Char. 16)
11
8–15
Configuration ID (Char. 15)
12
0–15
Reserved
13
0
Monitor Type
0 = B/W 1 = Color
13
1
Remote I/O Enable
0 = Disabled 1 = Enabled
13
2&4
Protocol–Port A
0 = ASCII 1 = DF1 2 = Not Specified 3 = Not Specified
13
3
Host Standby Mode
0 = Standby Enabled 1 = Standby Disabled
13
5&6
Protocol–Port B
0 = ASCII 1 = DF1 2 = Not Specified 3 = Not Specified
13
7–15
Reserved
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–2
Usage
Notes
Port A, see bits 5 & 6 for port B.
Port B, see bits 2 & 4 for port A.
Page 182
Appendix D Configuration Data
Table D.1 Configuration Block #1– System Environment (cont’d) Remote I/O & RS–232 Word #*
Bit #
14–15
0–15
Reserved
16
0–7
Toolset Display Status
16
8–15
Reserved
17
0–7
Reserved
17
8
Learn Mode
0 = Disabled 1 = Enabled
17
9
Outputs Enable
0 = Disabled 1 = Enabled
17
10
Freeze Enable
0 = Disabled 1 = Enabled
17
11
Halt Enable
0 = Disabled 1 = Enabled
17
12–15
Runtime Toolset Display
0 = Toolset 1 1 = Toolset 2
18–31
0–15
Reserved
32
0–15
Toolset 1 Pulse Width
In milliseconds.
33
0–15
Toolset 2 Pulse Width
In milliseconds.
34–44
0–15
Reserved
Definition
Usage
0 = Disabled 1 = Enabled
Notes
All tools appear simultaneously while setting a given tool.
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–3
Page 183
Appendix D Configuration Data
Configuration Blocks 2 & 3
Tables D.2 shows the function of each word in the camera definition configuration blocks. Table D.2 Configuration Block #2 & 3 – Camera Definition
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1
0–7
Camera Low Reference
0 = Minimum Value ... 100 = Maximum Value
These values do not correspond with the display on the help screen.
1
8–15
Camera High Reference
105 = Minimum Value ... 255 = Maximum Value
These values do not correspond with the display on the help screen.
2
0–7
Light Probe Status
0 = Disabled 1 = Same Field 2 = Next Field
2
8–15
Reserved
3
0–15
Light Probe X Location
16 = Minimum Value ... 504 = Maximum Value
4
0–15
Light Probe Y Location
8 = Minimum Value ... 232 = Maximum Value
5–9
0–15
Reserved
10
0–15
Fail Range High (Integer)
11
0–15
Fail Range High (Fraction)
12
0–15
Fail Range Low (Integer)
13
0–15
Fail Range Low (Fraction)
14
0–15
Warning Range High (Integer)
15
0–15
Warning Range High (Fraction)
16
0–15
Warning Range Low (Integer)
17
0–15
Warning Range Low (Fraction)
18–60
0–15
Reserved
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–4
Usage
Notes
Words 10 and 11 represent a 16 (bit) . 16 (bit) fixed point decimal value. Words 12 and 13 represent a 16(bit) . 16(bit) fixed point decimal value. Words 14 and 15 represent a 16 (bit). 16 (bit) fixed point decimal value. Words 16 and 17 represent a 16 (bit) . 16 (bit) fixed point decimal value.
Page 184
Appendix D Configuration Data
Configuration Blocks 4–6
Tables D.3 shows the function of each word in the reference line 1–3 (Toolset 1) configuration blocks. Table D.3 Configuration Blocks #4–6 – Reference Lines 1–3 (Toolset 1)
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1
0–7
Reserved
1
8
Enable
1
9–15
Reserved
2–7
0–15
Reserved
8
0–7
X–Line Low Threshold/Gray Scale Factor
0 – 63 0 – 39
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
8
8–15
X–Line High Threshold/Gradient Threshold
0 – 63 0 – 197
If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
9
0–15
Reserved
10
0–15
X–Line Head X Position
From upper left corner.
11
0–15
X–Line Head Y Position
From upper left corner.
12
0–15
X–Line Tail X Position
From upper left corner.
13
0–15
X–Line Tail Y Position
From upper left corner.
14
0–15
Reserved
15
0–7
Y–Line Low Threshold/Gray Scale Factor
0 – 63 0 – 39
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
15
8–15
Y–Line High Threshold/Gradient Threshold
0 – 63 0 – 197
If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
16
0–15
Reserved
17
0–15
Y–Line Head X Position
From upper left corner.
18
0–15
Y–Line Head Y Position
From upper left corner.
19
0–15
Y–Line Tail X Position
From upper left corner.
20
0–15
Y–Line Tail Y Position
From upper left corner.
21
0–15
Reserved
22
0–7
X/Y–Line Low Threshold/Gray Scale Factor
0 – 63 0 – 39
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
22
8–15
X/Y–Line High Threshold/Gradient Threshold
0 – 63 0 – 197
If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
Usage
Notes
0 = Disabled 1 = Enabled
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–5
Page 185
Appendix D Configuration Data
Configuration Blocks 4 – 6 (cont’d)
Table D.3 Configuration Blocks #4–6 – Reference Lines 1–3 (Toolset 1) continued
Remote I/O & RS–232 Word #*
Bit #
23
0–15
Reserved
24
0–15
X/Y–Line Head X Position
From upper left corner.
25
0–15
X/Y–Line Head Y Position
From upper left corner.
26
0–15
X/Y–Line Tail X Position
From upper left corner.
27
0–15
X/Y–Line Tail Y Position
From upper left corner.
28–29
0–15
Reserved
Definition
Usage
Notes
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Configuration Blocks 7 – 9
Table D.4 shows the function of each word in the reference window 1–3 (Toolset 1) configuration blocks. Table D.4 Configuration Blocks #7–9 – Reference Windows 1–3 (Toolset 1)
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1
0–7
Reserved
1
8
Enable
1
9–15
Reserved
2–7
0–15
Reserved
8
0–15
Feature 1 Search Window X Location
Relative to the upper left corner.
9
0–15
Feature 1 Search Window Y Location
Relative to the upper left corner.
10
0–15
Feature 1 Search Window Width
11
0–15
Feature 1 Search Window Height
12–15
0–15
Reserved
16
0–7
Reserved
16
8–15
Feature 1 Score
17
0–15
Feature 2 Search Window X Location
Relative to the upper left corner.
18
0–15
Feature 2 Search Window Y Location
Relative to the upper left corner.
19
0–15
Feature 2 Search Window Width
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–6
Usage
Notes
0 = Disabled 1 = Enabled
0 = Minimum Value 255 = Maximum Value
Page 186
Appendix D Configuration Data
Table D.4 Configuration Blocks #7–9 – Reference Windows 1–3 (Toolset 1) Remote I/O & RS–232 Word #*
Bit #
Definition
20
0–15
Feature 2 Search Window Height
21–24
0–15
Reserved
25
0–7
Reserved
25
8–15
Feature 2 Score
26
0–15
Feature 3 Search Window X Location
Relative to the upper left corner.
27
0–15
Feature 3 Search Window Y Location
Relative to the upper left corner.
28
0–15
Feature 3 Search Window Width
29
0–15
Feature 3 Search Window Height
30–33
0–15
Reserved
34
0–7
Reserved
34–35
8–15
Feature 3 Score
Usage
Notes
0 = Minimum Value 255 = Maximum Value
0 = Minimum Value 255 = Maximum Value
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Configuration Blocks 10 – 41
Table D.5 shows the function of each word in the gage 1–32 (Toolset 1) configuration blocks. Table D.5 Configuration Blocks #10–41 – Gages 1–32 (Toolset 1)
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1
0
Enable
1
1–15
Reserved
2–3
0–15
Reserved
4
0–7
Low Threshold/Gray Scale Factor
Usage
Notes
0 = Disabled 1 = Enabled
0 – 63 0 – 197
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–7
Page 187
Appendix D Configuration Data
Configuration Blocks 10 – 41 (cont’d) Table D.5 Configuration Blocks #10–41 – Gages 1–32 (Toolset 1) Remote I/O & RS–232 Word #*
Bit #
Definition
4
8–15
High Threshold/Gradient Threshold
5
0–15
Reserved
6
0–15
Gage Head X Position
7
0–15
Gage Head Y Position
8
0–15
Gage Tail X Position
9
0–15
Gage Tail Y Position
10
0–15
Gage X Center Position (Circular Gage)
11
0–15
Gage Y Center Position (Circular Gage)
12
0–15
Radius of Circular Gage
13–16
0–15
Reserved
17
0–15
Fail Range High (Integer)
18
0–15
Fail Range High (Fraction)
19
0–15
Fail Range Low (Integer)
20
0–15
Fail Range Low (Fraction)
21
0–15
Warning Range High (Integer)
22
0–15
Warning Range High (Fraction)
23
0–15
Warning Range Low (Integer)
24
0–15
Warning Range Low (Fraction)
25–27
0–15
Reserved
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–8
Usage 0 – 63 0 – 197
Notes If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
Words 17 and 18 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 19 and 20 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 21 and 22 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 23 and 24 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.
Page 188
Appendix D Configuration Data
Configuration Blocks 42 – 65
Table D.6 shows the function of each word in the window 1–24 (Toolset 1) configuration blocks. Table D.6 Configuration Blocks #42–65 – Windows 1–24 (Toolset 1)
Remote I/O & RS–232 Word #
Bit #
Definition
0
0–15
Block Transfer Signature
1
0
Enable
1
1–15
Reserved
2–4
0–15
Reserved
5
0– 7
Window Low Threshold
0 = Low Limit ... 63 = High Limit
5
8–15
Window High Threshold
0 = Low Limit ... 63 = High Limit
6–10
0–15
Reserved
11
0–15
Window X Location (Bounding Box)
12
0–15
Window Y Location (Bounding Box)
13
0–15
Window Width (Bounding Box)
14
0–15
Window Height (Bounding Box)
15
0–15
Mask X Location (Bounding Box)
16
0–15
Mask Y Location (Bounding Box)
17
0–15
Mask Width (Bounding Box)
18
0–15
Mask Height (Bounding Box)
19–27
0–15
Reserved
28
0–15
Fail Range High (Integer)
29
0–15
Fail Range High (Fraction)
30
0–15
Fail Range Low (Integer)
31
0–15
Fail Range Low (Fraction)
32
0–15
Warning Range High (Integer)
33
0–15
Warning Range High (Fraction)
34
0–15
Warning Range Low (Integer)
35–36
0–15
Warning Range Low (Fraction)
Usage
Notes
0 = Disabled 1 = Enabled
Words 28 and 29 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 30 and 31 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 32 and 33 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 34 and 35 represent a 16(bit) . 16(bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–9
Page 189
Appendix D Configuration Data
Configuration Blocks 66 – 68
Table D.7 shows the function of each word in the reference line 1–3 (Toolset 2) configuration blocks. Table D.7 Configuration Blocks #66–68 – Reference Lines 1–3 (Toolset 2)
Remote I/O & RS–232 Word #
Bit #
Definition
0
0–15
Block Transfer Signature
1
0–7
Reserved
1
8
Enabled
1
9–15
Reserved
2–7
0–15
Reserved
8
0–7
X–Line Low Threshold/Gray Scale Factor
0 – 63 0 – 39
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
8
8–15
X–Line High Threshold/Gradient Threshold
0 – 63 0 – 197
If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
9
0–15
Reserved
10
0–15
X–Line Head X Position
From upper left corner.
11
0–15
X–Line Head Y Position
From upper left corner.
12
0–15
X–Line Tail X Position
From upper left corner.
13
0–15
X–Line Tail Y Position
From upper left corner.
14
0–15
Reserved
15
0–7
Y–Line Low Threshold/Gray Scale Factor
0 – 63 0 – 39
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
15
8–15
Y–Line High Threshold/Gradient Threshold
0 – 63 0 – 197
If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
16
0–15
Reserved
17
0–15
Y–Line Head X Position
From upper left corner.
18
0–15
Y–Line Head Y Position
From upper left corner.
19
0–15
Y–Line Tail X Position
From upper left corner.
20
0–15
Y–Line Tail Y Position
From upper left corner.
21
0–15
Reserved
22
0–7
X/Y–Line Low Threshold/Gray Scale Factor
0 – 63 0 – 39
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
22
8–15
X/Y–Line High Threshold/ Gradient Threshold
0–63 0 – 197
If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–10
Usage
Notes
0 = Disabled 1 = Enabled
Page 190
Appendix D Configuration Data
Table D.7 Configuration Blocks #37–39 – Reference Lines 1–3 (Toolset 2) Remote I/O & RS–232 Word #
Bit #
23
0–15
Reserved
24
0–15
X/Y–Line Head X Position
From upper left corner.
25
0–15
X/Y–Line Head Y Position
From upper left corner.
26
0–15
X/Y–Line Tail X Position
From upper left corner.
27
0–15
X/Y–Line Tail Y Position
From upper left corner.
28–29
0–15
Reserved
Definition
Usage
Notes
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Configuration Blocks 69–71
Table D.8 shows the function of each word in the reference window 1–3 (Toolset 2) configuration blocks. Table D.8 Configuration Blocks #69–71 – Reference Windows 1–3 (Toolset 2)
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1
0–7
Reserved
1
8
Enable
1
9–15
Reserved
2–7
0– 15
Reserved
8
0– 15
Feature 1 Search Window X Location
Relative to the upper left corner.
9
0– 15
Feature 1 Search Window Y Location
Relative to the upper left corner.
10
0– 15
Feature 1 Search Window Width
11
0– 15
Feature 1 Search Window Height
12–15
0–15
Reserved
16
0–7
Reserved
16
8–15
Feature 1 Score
17
0–15
Feature 2 Search Window X Location
Relative to the upper left corner.
18
0–15
Feature 2 Search Window Y Location
Relative to the upper left corner.
Usage
Notes
0 = Disabled 1 = Enabled
0 = Minimum Value 255 = Maximum Value
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–11
Page 191
Appendix D Configuration Data
Configuration Blocks 69–71 (cont’d) Table D.8 Configuration Blocks #69–71 – Reference Windows 1–3 (Toolset 2) Remote I/O & RS–232 Word #*
Bit #
Definition
19
0–15
Feature 2 Search Window Width
20
0–15
Feature 2 Search Window Height
21–24
0–15
Reserved
25
0–7
Reserved
25
8–15
Feature 2 Score
26
0–15
Feature 3 Search Window X Location
Relative to the upper left corner.
27
0–15
Feature 3 Search Window Y Location
Relative to the upper left corner.
28
0–15
Feature 3 Search Window Width
Usage
Notes
0 = Minimum Value 255 = Maximum Value
29
0–15
Feature 3 Search Window Height
30–33
0–15
Reserved
34
0–7
Reserved
34–35
8–15
Feature 3 Score
0 = Minimum Value 255 = Maximum Value
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Configuration Blocks 72–103
Table D.9 shows the function of each word in the gage 1–32 (Toolset 2) configuration blocks. Table D.9 Configuration Blocks #72–103 – Gages 1–32 (Toolset 2)
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1
0
Enable
1
1–15
Reserved
2–3
0–15
Reserved
4
0–7
Low Threshold/Gray Scale Factor
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–12
Usage
Notes
0 = Disabled 1 = Enabled
0 – 63 0 – 39
If binary operation, value is used as the threshold. If gray scale operation, value is scale factor.
Page 192
Appendix D Configuration Data
Table D.9 Configuration Blocks #72–103 – Gages 1–32 (Toolset 2) Remote I/O & RS–232 Word #*
Bit #
Definition
4
8–15
High Threshold/Gradient Threshold
5
0–15
Reserved
6
0–15
Gage Head X Position
7
0–15
Gage Head Y Position
8
0–15
Gage Tail X Position
9
0–15
Gage Tail Y Position
10
0–15
Gage X Center Position (Circular Gage)
11
0–15
Gage Y Center Position (Circular Gage)
12
0–15
Radius of Circular Gage
13–16
0–15
Reserved
17
0–15
Fail Range High (Integer)
18
0–15
Fail Range High (Fraction)
19
0–15
Fail Range Low (Integer)
20
0–15
Fail Range Low (Fraction)
21
0–15
Warning Range High (Integer)
22
0–15
Warning Range High (Fraction)
23
0–15
Warning Range Low (Integer)
24
0–15
Warning Range Low (Fraction)
25–27
0–15
Reserved
Usage 0 – 63 0 – 197
Notes If binary operation, value is used as the threshold high. If gray scale operation, value is gradient threshold.
Words 17 and 18 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 19 and 20 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 21 and 22 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 23 and 24 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–13
Page 193
Appendix D Configuration Data
Configuration Blocks 104–127
Table D.10 shows the function of each word in the window 1–24 (Toolset 2) configuration blocks. Table D.10 Configuration Blocks #104–127 – Windows 1–24 (Toolset 2)
Remote I/O & RS–232 Word #*
Bit #
Definition
0
0–15
Block Transfer Signature
1
0
Enable
1
1–15
Reserved
2–4
0–15
Reserved
5
0–7
Window Low Threshold
0 = Low Limit ... 63 = High Limit
5
8–15
Window High Threshold
0 = Low Limit ... 63 = High Limit
6–10
0–15
Reserved
11
0–15
Window X Location (Bounding Box)
12
0–15
Window Y Location (Bounding Box)
13
0–15
Window Width (Bounding Box)
14
0–15
Window Height (Bounding Box)
15
0–15
Mask X Location (Bounding Box)
16
0–15
Mask Y Location (Bounding Box)
17
0–15
Mask Width (Bounding Box)
18
0–15
Mask Height (Bounding Box)
19–27
0–15
Reserved
28
0–15
Fail Range High (Integer)
29
0–15
Fail Range High (Fraction)
30
0–15
Fail Range Low (Integer)
31
0–15
Fail Range Low (Fraction)
32
0–15
Warning Range High (Integer)
33
0–15
Warning Range High (Fraction)
34
0–15
Warning Range Low (Integer)
35–36
0–15
Warning Range Low (Fraction)
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
D–14
Usage
Notes
0 = Disabled 1 = Enabled
Words 28 and 29 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 30 and 31 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 32 and 33 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A. Words 34 and 35 represent a 16 (bit) . 16 (bit) fixed point decimal value or 32 bit integer. Refer to Appendix A.
Page 194
Appendix D Configuration Data
Configuration Blocks 128–135
Table D.11 shows the function of each word in the polygon configuration blocks. Table D.11 Polygon Configuration Blocks #128–135
Remote I/O & RS–232 Word #*
Bit #
Definition
1
0–15
Block Transfer Signature
2–36
0–15
Reserved
Usage
Notes
* Refer to Chapter 6 for Pyramid Integrator long word descriptions.
Template Blocks 136–
The template blocks begin at block #136. The number of template blocks stored in memory is variable. Word 1, bits 8–15 (third byte sent using RS–232) of the first template block indicate the total number of template blocks in the configuration. You must always upload or download all of the template blocks as a unit. You cannot archive only a part of the template blocks. When uploading templates from the CVIM module, the program should read the first template block and check word 1, bits 8–15 (third byte sent using RS–232) to determine the number of template blocks to follow. The number of blocks remaining is then 1 less than the total number of template blocks. When downloading templates to the CVIM module, the program must send all template blocks. Bits 8–15 of word 1 determine the number of blocks to send.
D–15