Summary
What is in it
The user manual for the Allen-Bradley 5370 CVIM (Configurable Vision Input Module) machine vision system, which uses a camera to inspect workpieces and sends a pass/fail result to production equipment. It covers connecting and powering up the system, the light pen user interface, camera and lighting setup, reference lines and windows, gages and inspection windows, saving configurations and runtime operation, with planning appendices for discrete I/O and system configuration.
Its parts
- Introduction: CVIM Machine Vision
- CVIM Hardware Connection and Powerup Check
- CVIM User Interface
- Operating Environment
- Camera and Lighting Parameters
- Reference Tools: Lines and Windows
- Inspection Tools: Gages
- Inspection Tools: Windows
- Configuration Aids and Storage Functions
- Runtime Functions
- Planning Discrete I/O Assignments and Connections
- Planning System Configuration
- Definition of Terms
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is the Allen-Bradley user manual for the Bulletin 5370 CVIM Configurable Vision Input Module (5370-CVIM), a machine vision module that inspects parts with one or two cameras and signals pass or fail to production equipment. It explains how to connect and power up the system, use the light pen interface, set up cameras, lighting and inspection tools, store configurations and run inspections.
- Module
- Machine vision module that occupies one slot in a Pyramid Integrator chassis; a 4-slot chassis takes up to four CVIM modules, an 8-slot chassis up to eight p. 16
- Cameras
- Up to two per module; camera 2801-YC p. 18, 23
- Communication channels
- 16 discrete I/O lines, a remote I/O port, an RS-232 port and the chassis backplane p. 19
- Discrete I/O
- 16 optically isolated lines on the 1771-JMB board: 2 trigger inputs and 14 assignable outputs p. 18, 19
- Chassis power supply
- Input 90 to 132 VAC or 180 to 264 VAC at 47 to 63 Hz; outputs +5, +12 and -12 VDC p. 16, 25
- Current draw (±12V)
- +12V/-12V: 0.065A/0.075A with no camera, 0.275A/0.285A with one, 0.405A/0.415A with two p. 26
- External 24VDC option
- Camera power from an external +24VDC supply: 0.210A with one camera, 0.340A with two; set by a DC voltage-selection switch on the module p. 26, 27
- System parts
- Chassis 5110-A8 (eight-slot), light pen 2801-N7, user interface box 2801-N22, I/O interface box 2801-N21, interface board 1771-JMB p. 23
- Monitors
- Monochrome 2801-N9 (115VAC) and 2801-N20 (230VAC); a video monitor and light pen are required for configuration p. 17, 23
- Cables
- Camera 2801-NC14, -NC15, NC-16; user interface 2801-NC18A, -NC18B, -NC18C; I/O 2801-NC17; video 2801-NC2, -NC3 p. 19
- Module I/O connector
- 26-pin D-type: pins 1-2 trigger inputs, 3-16 output lines 1-14, 19-22 grounds, 23-26 RS-232 (TXD, RTS, RXD, CTS) p. 354
- RS-232 connector
- D-type connector on the I/O Interface Box: pin 2 RXD, 3 TXD, 4 chassis ground, 5 signal ground, 7 RTS, 8 CTS p. 355
- Operating modes
- Stand-alone (discrete I/O to production equipment) or hosted through remote I/O, RS-232 or the backplane p. 15
- JMB board power
- 1771-JMB has a terminal block for an external +5VDC supply p. 355
What this manual walks you through
- Setting the chassis power supply voltage switch and installing it p. 24, 25
- Choosing internal or external camera power and setting the DC switch p. 26, 27
- Connecting the user interface box, cameras, monitor and light pen p. 28, 29, 30
- Wiring an external 24VDC supply with the 5120-CP2 or 5120-CP3 cable p. 31
- Powerup check and reading the front panel lights p. 31, 32, 33
- Pin assignments for the Module I/O and RS-232 connectors p. 354, 355
Good to know
- Connecting the camera cable to the User Interface connector can damage the CVIM module. p. 29
- If the modules and cameras draw more than the chassis supply's +12V or -12V section can give, an external 24VDC supply must be used. p. 27
- The procedures in the manual assume a color monitor. p. 17
- The manual does not cover configuring the system for specific applications. p. 13
Questions this manual answers
What AC input does the CVIM chassis power supply need?
90 to 132 VAC or 180 to 264 VAC at 47 to 63 Hz, chosen with a voltage-selection switch (115V or 230V setting). p. 25
How many cameras can one CVIM module use?
Two cameras, connected to the Camera A and Camera B ports. p. 18, 29
What does a red Pass/Fail light at CVIM powerup mean?
The powerup sequence failed. Remove power, check the cable connections, re-seat the power supply and CVIM modules, and try again. p. 33
Which cable connects the CVIM to the I/O interface box?
Cable 2801-NC17, from the 26-pin Module I/O connector to the 2801-N21 I/O Interface Box. p. 354
When does a CVIM system need an external 24VDC supply?
When the total current of all modules and cameras exceeds the +12V or -12V capacity of the chassis power supply. p. 27
Contents
Chapters and sections
Each line opens the PDF at its page.
- 5370-ND001, Bulletin 5370 CVIM Configurable Vision Input Module User Manual1
- Important User Information2
- 1 - Introduction: CVIM Machine Vision13
- 2 - CVIM Hardware Connection and Powerup Check23
- 3 - CVIM User Interface35
- 4 - Operating Environment47
- 5 - Camera and Lighting Parameters67
- 6 - Reference Tools: Lines and Windows117
- 7 - Inspection Tools: Gages191
The whole text · 42 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 121-12
- 1 - Introduction: CVIM Machine Vision13-22
- 2 - CVIM Hardware Connection and Powerup Check23-34
- 3 - CVIM User Interface35-46
- 4 - Operating Environment, pages 47 to 5647-56
- 4 - Operating Environment, pages 57 to 6657-66
- 5 - Camera and Lighting Parameters, pages 67 to 7667-76
- 5 - Camera and Lighting Parameters, pages 77 to 8677-86
- 5 - Camera and Lighting Parameters, pages 87 to 9687-96
- 5 - Camera and Lighting Parameters, pages 97 to 10697-106
- 5 - Camera and Lighting Parameters, pages 107 to 116107-116
- 6 - Reference Tools: Lines and Windows, pages 117 to 126117-126
- 6 - Reference Tools: Lines and Windows, pages 127 to 136127-136
- 6 - Reference Tools: Lines and Windows, pages 137 to 146137-146
- 6 - Reference Tools: Lines and Windows, pages 147 to 156147-156
- 6 - Reference Tools: Lines and Windows, pages 157 to 166157-166
- 6 - Reference Tools: Lines and Windows, pages 167 to 176167-176
- 6 - Reference Tools: Lines and Windows, pages 177 to 186177-186
- 6 - Reference Tools: Lines and Windows, pages 187 to 190187-190
- 7 - Inspection Tools: Gages, pages 191 to 199191-199
- 7 - Inspection Tools: Gages, pages 200 to 208200-208
- 7 - Inspection Tools: Gages, pages 209 to 217209-217
- 7 - Inspection Tools: Gages, pages 218 to 226218-226
- 7 - Inspection Tools: Gages, pages 227 to 235227-235
- 7 - Inspection Tools: Gages, pages 236 to 244236-244
- 8 - Inspection Tools: Windows, pages 245 to 254245-254
- 8 - Inspection Tools: Windows, pages 255 to 264255-264
- 8 - Inspection Tools: Windows, pages 265 to 274265-274
- 8 - Inspection Tools: Windows, pages 275 to 284275-284
- 8 - Inspection Tools: Windows, pages 285 to 294285-294
- 8 - Inspection Tools: Windows, pages 295 to 300295-300
- 9 - Configuration Aids and Storage Functions, pages 301 to 308301-308
- 9 - Configuration Aids and Storage Functions, pages 309 to 316309-316
- 9 - Configuration Aids and Storage Functions, pages 317 to 324317-324
- 10 - Runtime Functions, pages 325 to 332325-332
- 10 - Runtime Functions, pages 333 to 340333-340
- 10 - Runtime Functions, pages 341 to 346341-346
- A - Planning Discrete I/O Assignments and Connections347-358
- B - Planning System Configuration, pages 359 to 366359-366
- B - Planning System Configuration, pages 367 to 374367-374
- C - Definition of Terms375-382
- Pages 383 to 390383-390
The file