Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Bulletin 5370 CVIM Configurable Vision Input Module User Manual

Manual · Allen-Bradley

Bulletin 5370 CVIM Configurable Vision Input Module User Manual

Manual390 pagesPDF 26 MB

User manual for the Allen-Bradley Bulletin 5370 CVIM Configurable Vision Input Module machine vision system.

Download the PDF26 MB

Names · 1 model

The models it names

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The user manual for the Allen-Bradley 5370 CVIM (Configurable Vision Input Module) machine vision system, which uses a camera to inspect workpieces and sends a pass/fail result to production equipment. It covers connecting and powering up the system, the light pen user interface, camera and lighting setup, reference lines and windows, gages and inspection windows, saving configurations and runtime operation, with planning appendices for discrete I/O and system configuration.

Its parts

  1. Introduction: CVIM Machine Vision
  2. CVIM Hardware Connection and Powerup Check
  3. CVIM User Interface
  4. Operating Environment
  5. Camera and Lighting Parameters
  6. Reference Tools: Lines and Windows
  7. Inspection Tools: Gages
  8. Inspection Tools: Windows
  9. Configuration Aids and Storage Functions
  10. Runtime Functions
  11. Planning Discrete I/O Assignments and Connections
  12. Planning System Configuration
  13. Definition of Terms

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is the Allen-Bradley user manual for the Bulletin 5370 CVIM Configurable Vision Input Module (5370-CVIM), a machine vision module that inspects parts with one or two cameras and signals pass or fail to production equipment. It explains how to connect and power up the system, use the light pen interface, set up cameras, lighting and inspection tools, store configurations and run inspections.

Read for this summary: pages 1, 13 to 21, 23 to 33 and 354 to 355 of 390.

Module
Machine vision module that occupies one slot in a Pyramid Integrator chassis; a 4-slot chassis takes up to four CVIM modules, an 8-slot chassis up to eight p. 16
Cameras
Up to two per module; camera 2801-YC p. 18, 23
Communication channels
16 discrete I/O lines, a remote I/O port, an RS-232 port and the chassis backplane p. 19
Discrete I/O
16 optically isolated lines on the 1771-JMB board: 2 trigger inputs and 14 assignable outputs p. 18, 19
Chassis power supply
Input 90 to 132 VAC or 180 to 264 VAC at 47 to 63 Hz; outputs +5, +12 and -12 VDC p. 16, 25
Current draw (±12V)
+12V/-12V: 0.065A/0.075A with no camera, 0.275A/0.285A with one, 0.405A/0.415A with two p. 26
External 24VDC option
Camera power from an external +24VDC supply: 0.210A with one camera, 0.340A with two; set by a DC voltage-selection switch on the module p. 26, 27
System parts
Chassis 5110-A8 (eight-slot), light pen 2801-N7, user interface box 2801-N22, I/O interface box 2801-N21, interface board 1771-JMB p. 23
Monitors
Monochrome 2801-N9 (115VAC) and 2801-N20 (230VAC); a video monitor and light pen are required for configuration p. 17, 23
Cables
Camera 2801-NC14, -NC15, NC-16; user interface 2801-NC18A, -NC18B, -NC18C; I/O 2801-NC17; video 2801-NC2, -NC3 p. 19
Module I/O connector
26-pin D-type: pins 1-2 trigger inputs, 3-16 output lines 1-14, 19-22 grounds, 23-26 RS-232 (TXD, RTS, RXD, CTS) p. 354
RS-232 connector
D-type connector on the I/O Interface Box: pin 2 RXD, 3 TXD, 4 chassis ground, 5 signal ground, 7 RTS, 8 CTS p. 355
Operating modes
Stand-alone (discrete I/O to production equipment) or hosted through remote I/O, RS-232 or the backplane p. 15
JMB board power
1771-JMB has a terminal block for an external +5VDC supply p. 355

What this manual walks you through

  • Setting the chassis power supply voltage switch and installing it p. 24, 25
  • Choosing internal or external camera power and setting the DC switch p. 26, 27
  • Connecting the user interface box, cameras, monitor and light pen p. 28, 29, 30
  • Wiring an external 24VDC supply with the 5120-CP2 or 5120-CP3 cable p. 31
  • Powerup check and reading the front panel lights p. 31, 32, 33
  • Pin assignments for the Module I/O and RS-232 connectors p. 354, 355

Good to know

  • Connecting the camera cable to the User Interface connector can damage the CVIM module. p. 29
  • If the modules and cameras draw more than the chassis supply's +12V or -12V section can give, an external 24VDC supply must be used. p. 27
  • The procedures in the manual assume a color monitor. p. 17
  • The manual does not cover configuring the system for specific applications. p. 13

Questions this manual answers

What AC input does the CVIM chassis power supply need?

90 to 132 VAC or 180 to 264 VAC at 47 to 63 Hz, chosen with a voltage-selection switch (115V or 230V setting). p. 25

How many cameras can one CVIM module use?

Two cameras, connected to the Camera A and Camera B ports. p. 18, 29

What does a red Pass/Fail light at CVIM powerup mean?

The powerup sequence failed. Remove power, check the cable connections, re-seat the power supply and CVIM modules, and try again. p. 33

Which cable connects the CVIM to the I/O interface box?

Cable 2801-NC17, from the 26-pin Module I/O connector to the 2801-N21 I/O Interface Box. p. 354

When does a CVIM system need an external 24VDC supply?

When the total current of all modules and cameras exceeds the +12V or -12V capacity of the chassis power supply. p. 27

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 5370-ND001, Bulletin 5370 CVIM Configurable Vision Input Module User Manual1
  2. Important User Information2
  3. 1 - Introduction: CVIM Machine Vision13
    1. Chapter Objective13
    2. CVIM Quick Start Self-Training Guide13
    3. User Manual Objective13
    4. User Experience14
    5. CVIM Machine Vision: System Overview14
    6. CVIM Operating Modes15
    7. Basic Hardware16
    8. Communication Channels19
    9. Warnings and Cautions20
    10. Reference Publications21
  4. 2 - CVIM Hardware Connection and Powerup Check23
    1. Chapter Objectives23
    2. CVIM System Components23
    3. Connecting CVIM System Components23
    4. Powering Up CVIM System31
  5. 3 - CVIM User Interface35
    1. Chapter Objective35
    2. CVIM User Interface35
    3. Graphic Figures38
    4. Configuration Shortcut43
    5. Help Messages45
    6. Menu Removal Function45
  6. 4 - Operating Environment47
    1. Chapter Objective47
    2. Operating Environment47
    3. Configuring Operating Environment48
  7. 5 - Camera and Lighting Parameters67
    1. Chapter Objectives67
    2. Configuration Categories67
    3. Configuring Camera and Lighting Parameters68
  8. 6 - Reference Tools: Lines and Windows117
    1. Chapter Objectives117
    2. A Few Questions and Answers About Reference Tools117
    3. Reference Lines118
    4. Reference Windows154
  9. 7 - Inspection Tools: Gages191
28 more lines, from page 191 on
  1. Chapter Objectives191
    1. A Few Questions and Answers About Gages191
    2. Gages192
  2. 8 - Inspection Tools: Windows245
    1. Chapter Objectives245
    2. A Few Questions and Answers About Windows245
    3. Windows246
  3. 9 - Configuration Aids and Storage Functions301
    1. Chapter Objectives301
    2. Configuration Aids and Storage: Overview301
    3. Using Configuration Aids and Storage Functions301
  4. 10 - Runtime Functions325
    1. Chapter Objectives325
    2. Runtime Functions: Overview325
    3. Using Runtime Functions325
  5. A - Planning Discrete I/O Assignments and Connections347
    1. Appendix Objective347
    2. Planning Output Line Assignments347
    3. Planning Output Line Connections354
  6. B - Planning System Configuration359
    1. Appendix Objective359
    2. System Configuration Planning359
    3. Configuration Planning Tables359
  7. C - Definition of Terms375
    1. Appendix Objective375
    2. Definition of Terms375
  8. Index383
  9. Back Cover390

From the PDF’s own bookmarks.

The whole text · 42 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 121-12
  2. 1 - Introduction: CVIM Machine Vision13-22
  3. 2 - CVIM Hardware Connection and Powerup Check23-34
  4. 3 - CVIM User Interface35-46
  5. 4 - Operating Environment, pages 47 to 5647-56
  6. 4 - Operating Environment, pages 57 to 6657-66
  7. 5 - Camera and Lighting Parameters, pages 67 to 7667-76
  8. 5 - Camera and Lighting Parameters, pages 77 to 8677-86
  9. 5 - Camera and Lighting Parameters, pages 87 to 9687-96
  10. 5 - Camera and Lighting Parameters, pages 97 to 10697-106
  11. 5 - Camera and Lighting Parameters, pages 107 to 116107-116
  12. 6 - Reference Tools: Lines and Windows, pages 117 to 126117-126
  13. 6 - Reference Tools: Lines and Windows, pages 127 to 136127-136
  14. 6 - Reference Tools: Lines and Windows, pages 137 to 146137-146
  15. 6 - Reference Tools: Lines and Windows, pages 147 to 156147-156
  16. 6 - Reference Tools: Lines and Windows, pages 157 to 166157-166
  17. 6 - Reference Tools: Lines and Windows, pages 167 to 176167-176
  18. 6 - Reference Tools: Lines and Windows, pages 177 to 186177-186
  19. 6 - Reference Tools: Lines and Windows, pages 187 to 190187-190
  20. 7 - Inspection Tools: Gages, pages 191 to 199191-199
  21. 7 - Inspection Tools: Gages, pages 200 to 208200-208
  22. 7 - Inspection Tools: Gages, pages 209 to 217209-217
  23. 7 - Inspection Tools: Gages, pages 218 to 226218-226
  24. 7 - Inspection Tools: Gages, pages 227 to 235227-235
  25. 7 - Inspection Tools: Gages, pages 236 to 244236-244
  26. 8 - Inspection Tools: Windows, pages 245 to 254245-254
  27. 8 - Inspection Tools: Windows, pages 255 to 264255-264
  28. 8 - Inspection Tools: Windows, pages 265 to 274265-274
  29. 8 - Inspection Tools: Windows, pages 275 to 284275-284
  30. 8 - Inspection Tools: Windows, pages 285 to 294285-294
  31. 8 - Inspection Tools: Windows, pages 295 to 300295-300
  32. 9 - Configuration Aids and Storage Functions, pages 301 to 308301-308
  33. 9 - Configuration Aids and Storage Functions, pages 309 to 316309-316
  34. 9 - Configuration Aids and Storage Functions, pages 317 to 324317-324
  35. 10 - Runtime Functions, pages 325 to 332325-332
  36. 10 - Runtime Functions, pages 333 to 340333-340
  37. 10 - Runtime Functions, pages 341 to 346341-346
  38. A - Planning Discrete I/O Assignments and Connections347-358
  39. B - Planning System Configuration, pages 359 to 366359-366
  40. B - Planning System Configuration, pages 367 to 374367-374
  41. C - Definition of Terms375-382
  42. Pages 383 to 390383-390

The file

Revision and size

RevisionCatalog No. 5370-ND001, Series B, 1995
PublisherAllen-Bradley
Pages390
PDF26 MB
TextText from the PDF itself; pages 1 and 373 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 390

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 390
Page 2
Page 2of 390
Page 3
Page 3of 390

More documents · 1

For the same models