Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 36 of 42

Bulletin 5370 CVIM Configurable Vision Input Module User Manual: 10 - Runtime Functions, pages 333 to 340

Pages 333 to 340 of 390, from Bulletin 5370 CVIM Configurable Vision Input Module User Manual

The original document is the PDF (26 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 5370-CVIM

Page 333

Chapter 10

Runtime Functions 10-9

Selecting Runtime Popup Menu

Select the Runtime popup menu, then select either the run mode function to start an inspection operation, or select the Save Config. (Int) function to store the current configuration in the CVIM module’s EEPROM. Comments

Your Action Pick the Runtime menu box in the Exit popup menu.

When you pick the Runtime menu box, the Runtime popup menu appears above the Exit popup menu, as follows: Goto Runmode Save Config. Runtime Init.

Env.

-

(Int)

Camera A

Runtime Popup Menu

0.0

Ref. Line

Ref. Win

Gage

Window

Mist

Selecting Save Config. (Int) function Select the Save Config. (Int) function to store the current configuration in CVIM system EEPROM. This function operates the same as the Save Config. (Int) function described in Chapter 9, Configuration Aids and Storage. Your Action Pick the Save Config. (Int) menu box, if appropriate.

Comments When you pick the Save Config. (Int) menu box, the CVIM system will store the current configuration in the EEPROM. The following message appears in the message box in the upper part of the monitor screen:

Saving Configuration

This indicates that configuration storage is under way.

NOTE: If a power interruption occurs here, configurations in both the CVIM system EEPROM and RAM will be lost. After a moment, the following message appears in the message box:

Configuration

Saved

This indicates that configuration storage is finished.

Page 334

Chapter 10 RuntimeFunctions

IO-70

Selecting Goto Runmode Function

-

Select the Goto Runmode to set the CVIM system to the run mode. Note that the CVIM system will not actually perform an inspection operation until it receives a trigger signal. The trigger source that you set earlier (Chapter 4, Operating Erzvironment) will determine the system’s response when you select the Goto Runmode function. Thus, if you have selected Auto/Internal as the runtime trigger source, the system will immediately begin performing inspections. If you have selected the I/O (discrete) or hosted trigger source, the system will wait until it receives a trigger signal from the I/O or host source before it performs an inspection. It will perform ooze inspection per trigger signal. Your Action Pick the Goto Runmode menu box to start an inspection operation.

Comments When you pick the Goto Runmode menu box, the CVIM system will enter the run mode, and the Run Mode menu will appear at the bottom of the screen, as follows: Reset Stat’s -

In addition to the Run Mode menu, the display selection that you picked earlier in the Runtime Display popup menu will appear on the screen above the menu. The contents of these display selections are explained in detail in the following section. If you want to change the display after the run mode begins, you can do so by picking the Display menu box in the Run Mode menu, as follows: Reset Stat’s

Note that the seven display selections appear in boxes alongside the Display menu box. The I/O Page selection is darkened, indicating that the I/O Page is the currently selected display appearing on the monitor screen. To change to another display selection, simply pick the box with that selection. The current selection (I/O Page, in this example) will be replaced by the new selection.

Page 335

Chapter 10

Runtime Functions 10-l 1

Interpreting

Run Mode Displays

At the start of the run mode, the monitor screen diplays the camera image and Run Mode menu either alone or in combination with either tool symbols or a display page. The specific symbol(s) or table appearing on the screen depends, as shown earlier, on which display selection you picked in the Runtime Display popup menu.

NOTE: Tool processing takes precedence over tool display. Thus, although all tools are processed, in certain high-speed applications, some tools may not always be displayed. These symbols and display pages show, in various forms, the results of each inspection operation for the currently selected tool set. Here is a detailed description of these symbols and display pages: Image Only If you picked this display selection, only the camera image and Run Mode menu appear on the monitor screen. You may want to use this selection to view the complete camera image. failed Tools This display selection shows the camera image and the enabled analysis tools (except the light probe) that fail an inspection will appear on the screen. These are the tools whose inspection “results” are outside one of the warning or fault range limits that you set during configuration. On a color monitor, the tools whose results exceed a fault limit appear in red. The tools whose results exceed a warning limit only appear in yellow. All Tools This display selection shows the camera image and al2 enabled analysis tools (except the light probe). This applies whether the tools pass or fail the inspection. On a color monitor the tools that pass an inspection appear in green. These are the tools whose inspection results are within both the fault and the warning range limits. The tools that fail an inspection appear in red. These are the tools whose inspection results are outside one of the fault range limits. The tools whose results are outside one of the warning range limits, but are within both fault range limits appear in yellow.

Page 336

IO-12

Chapter 10

Rontime Functions

Interpreting Run Mode Displays (continued)

1. 2. 3. 4.

II0 Page If you picked the I/O Page display selection, the I/O Page will appear on the screen when you start the run mode: INSPECTION RESULT OUTPUTS Disabled/forced 5. 9. 13. + 6. 10. 14. 7. 11. a. 12.

1. 2. 3.

17. ia. 19. 20. 21. 22. 23. 24.

9. 10. 11. 12. 13. 14. 15. 16.

1. 2. 3.

WINDOWS

GAGES 1. 2. 3. 4. 5. 6. 7. a.

REFERENCE LINES I WINDOWS

LIGHT PROBE

25. 26. 27. 28. 29. 30. 31. 32.

1. 2. 3. 4. 5. 6. 7. a.

9. 10. 11. 12. 13. 14. 15. 16.

17. ia. 19. 20. 21. 22. 23. 24.

The I/O Page is a table that summarizes the inspection “results” for all enabled analysis tools in whichever tool set is currently selected. These appear in the GAGE, WINDOWS, LIGHT PROBE, and REFERENCE LINES / WINDOWS blocks. The table uses color blocks (color monitor) or letters and words (monochorme monitor) to indicate the “pass/warning/fail” status of the inspection results. In the INSPECTION RESULT OUTPUTS block, the I/O Page shows the “pass/fail” status of each “results” output line to which an enabled analysis tool is assigned. The L/O page also shows the “pass/fail” status of the Master Range signal if it is assigned to an output line. Appearing directly under the INSPECTION RESULT OUTPUTS heading is the status of the output lines. This can take one of the following forms: l No message - The output lines are ena bled.

l Disabled

- The output lines are disabled.

l Forced -The output lines are enabled, but some may be forced to either the “on” or the “off’ state by a host system. The lines that are forced “on” have a plus ( + ) sign (see line 13 in the figure above). The lines that are forced “off’ have a minus (-) sign (see line 14). l Disabled/forced - The output lines are disabled, but some may be forced to either the “on” of the “off’ state. (The “forced” condition takes precedence over the “disabled” condition.)

-

Page 337

Chapter 10

Runtime Functions 10-13

Interpreting Run Mode Disp/ays (continued)

110 Page (continued) In all of the above cases, the appearance of the inspection results (the color blocks or words and letters) nay not reflect the output line status. The I/O Page is updated at the end of each inspection, permitting.

time

NOTE 1: Since more than one tool can be assigned to a particular output line, that line will indicate an “off’ condition only if all tools assigned to it pass inspection. If one tool fails inspection, the output line will indicate an “on” condition regardless of whether the other tools pass or fail. NOTE 2: The I/O Page indicates only the “results” for analysis tools. It does not show signals from strobe, trigger NAK, data valid, or module busy conditions. On a color monitor screen, the I/O Page uses small colored blocks to indicate inspection results for the analysis tools and output lines, as follows: blocks indicate a pass condition for tools and an off condition for the output lines. l Green blocks indicate a fail condition for tools and an on condition for the output lines.

l Red l YeZlow blocks indicate a warning condition for the light probe, gages, and windows only. They do not apply to reference tools and output lines. The color blocks appear as shown in the following example of a color I/O Page:

GAGES

WINDOWS

Page 338

Chapter 10

Runtime Functions lo-74

Interpreting Run Mode Displays (continued)

I/O Page (continued) Output lines 1,2, and 4 are “green,” indicating an “off” condition. This means that the tool inspection results connected to these lines are ulithin their respective range limits, Output lines 3,5, and 6 are “red,” indicating an “on” condition. This means that the tool inspection results connected to these lines are outside one of their respective range limits. Note that a tool whose inspection results are outside a warning range limit causes a “red” output line indication. Gages 1,2, and 4 are “green,” indicating that the inspection results for these gages are within both the warning and the fault limits. Gage 3 is “yellow,” indicating that the inspection results for this gage are within the fault limits, but outside one of the warning limits. Gages 5 and 7 are “red,” indicating that the inspection results for this gage are outside both the fault limits and the warning limits. NOTE: The I/O Page does not show how the tools are assigned to the output lines; thus, you cannot determine by looking only at the I/O Page whether output lines 1,2, and 4 correspond to gages 1,2, and 4, or whether output lines 3,5, and 6 correspond to gages 3,5, and 6. To determine the gageto-output line assignments, you will need to look at the output line assignments for each gage. On a monochrome monitor screen, the I/O Page uses letters and words to indicate inspection results for the analysis tools and output lines, as follows: l Upper case P indicates a pass condition for all tools.

l Upper case F indicates a fail condition for all tools.

l Upper case W indicates a warning condition for the light probe, gages, and windows. l The words Off and On indicate the condition of the output lines.

Page 339

Chapter 10

Runtime Functions 10-15

Interpreting Run Mode Displays (continued)

110 Page (continued) The words and letters appear as shown in the following example of a monochrome I/O Page: INSPECTION

1. Off 2. Off 3. On 4. Off

RESULTS Disabled 5. On 9. 6. On 10. 7. 11. 8. 12.

LIGHT PROBE

OUTPUTS 13. 14.

1. 2. 3.

9. 10. 11. 12. 13. 14. 15. 16.

17. 18. 19. 20. 21. 22. 23. 24.

1. 2. 3.

WINDOWS

GAGES I. P ) P ;: w 1. P 5. F 5. F 7. 3.

REFERENCE LINES / WINDOWS

25. 26. 27. 28. 29. 30. 31 32.

1. 2. 3. 4. 5. 6. 7. 8.

9. 10. 11. 12. 13. 14. 15. 16.

17. 18. 19. 20. 21. 22. 23. 24.

Output lines 1,2, and 4 are “off.” This means that the inspection results to these lines are from tools that have passed their inspections. Output lines 3,5, and 6 are “on.” This means that the inspection results to these lines are from tools that have either failed their inspections or have a warning condition. Note that a warning condition from a tool causes an “on” output line indication. Gages 1,2, and 4 show a “P,” indicating that the inspection results for these gages are within both the warning and the fault limits. Gage 3 shows a ‘W,” indicating that the inspection results for this gage are within the fault limits, but outside one of the warning limits. Gages 5 and 7 shows a “F,” indicating that the inspection results for this gage are outside one of the fault limits. As was stated in the preceeding NOTE, the I/O Page does not show how the tools are assigned to the output lines.

Page 340

Chapter 10 lo-16 interpreting Run Mode Displays (continued)

I

Runtime Functions

Results Page If you picked the Results Page display selection, the Results Page will appear on the screen when you start the run mode, as follows: FAULTS

TRI GGERS Act:epted: Mi! ssed : To1 tal: GA ,GE 1. 2.

123456 0

Master Fault: Light Probe:

12 1

Reference 1. 2. 3.

Lines 2

/ Windows 1. 2. 3.

1

123456 Faults 1 12

Fail Low 130.000 25.000

Warn Low 140.000 28.000

Reading 150.187 32.354

Warn Hi 160.000 34.000

Fail Hi 170.000 37.000

Faults 1

Fail Low 3000.000

Warn Low 3100.000

Reading 3214.485

Warn Hi 3300.000

Fail Hi 3400.000

3. 6 WI NDOW 1. 2. 3.

The Results Page is a table that summarizes inspection results for all enabled analysis tools for whichever tool set is currently selected. The Results Page is updated at the end of each inspection, time permitting. The TRIGGER section shows the total number of trigger signals received; and of those, the number that the system was able to process and the number that it could not process. Typically, the CVIM system will miss a trigger if the trigger appears before the system is finished processing data from the last trigger. The FAULT section shows the accumulation of faults from the light probe and any of the reference or inspection tools. In the example page above, the light probe has 1 fault and the master fault has 12 faults (this is from gage 1). The absence of numbers next to reference lines 2 and 3 and reference windows 2 and 3 indicate that these tools are not enabled. This also applies to gages and windows. The GAGE and WINDOW sections show the accumulation faults, the low and high range limits that you set for each tool, and the “reading” or measurement from the current inspection. On the color monitor, the readings appear in green,.red, or yellow, indicating a pass, fail, or warning condltlon.

of

-