The text of a manual · part 37 of 42
Bulletin 5370 CVIM Configurable Vision Input Module User Manual: 10 - Runtime Functions, pages 341 to 346
Pages 341 to 346 of 390, from Bulletin 5370 CVIM Configurable Vision Input Module User Manual
The original document is the PDF (26 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 5370-CVIM
Page 341
Chapter 10
Runtime Functions IO-17 lnterpre ting Run Mode Displays (continued)
Results Page (continued) Note that in the GAGE section and WINDOW section above, only gages 1 to 4 and windows 1 to 3 are shown. You can display the results for the remaining gages and windows by picking the Page 4 (page down) menu box in the Runtime menu. This will scroll the page so that you will now see the results for gages 5 - 8 and windows 4 - 6. Pick Page J again and gages 9 - 12 and windows will appear. You can repeat this process until gages 29 - 32 and windows 22 - 24 appear. To reverse the page scroll, pick the Page t (page up) menu box. NOTE: The Page i menu box has additional functions. When you pick the Page J box successively, reference tool data will appear in the FAULT block as shown in the following figures. ,!&!&wihe first page-down, the “fault” block appears as ..
TRIGGERS Accepted: Missed: Total : GAGE 5. 6. 7. 8. WINDOW 4. 5. 6.
Reference 123456 0 123579
Faults
Faults
Line Readings
1.X: 157 Y: 203 8: 88.33”
3.x: Y: 0:
2.x: Y: 0:
Fail Low
Warn Low
Reading
Warn Hi
Fail Hi
Fail Low
Warn Low
Reading
Warn Hi
Fail Hi
The block now displays “readings” (“results” data) from all enabled reference lines. This data consists of the X and/or Y coordinates of the selected “feature” (edge or midpoint). Note that the gage and window numbers have advanced to the next level.
Page 342
Chapter
10
Runtime
Functions
IO-78
Interpreting Run Mode Disp/ays (continued)
Results Page (continued) After the second page-down the block appears as follows: Reference Window
TRIGGERS Accepted: Missed: Total : GAGE 9. 10. 11. 12. WINDOW 7. 8. 9.
123456 0 123579 Faults
Faults
1.1 X: 362 Y: 106 5: 4
Readings
1.2 X: 378 Y: 380 5: 2
1.3 x:212 Y: 213 s: 2 xx: Y: 8:
317 233 62.58"
Fail Low
Warn Low
Reading
Warn Hi
Fail Hi
Fail Low
Warn Low
Reading
Warn Hi
Fail Hi
The block now displays the “readings” (“results” data) from each active feature in an enabled reference window # 1. (No data appears for inactive features or disabled windows.) The results data in the columns labeled “1.1,” “1.2,” and “1.3” consists of the X and Y coordinates of the upper-left corner(s) of the feature window(s) and the “score” value (S). The results data in the column labeled “2” consists of the X and Y coordinates of the shift reference point and the angle (6) of the rotation reference line (these are described in Chapter 6 under the Using Learn Function heading in the Reference Windows section.) Note that the gage and window numbers have advanced to their next levels. The third and fourth page-downs display the same type of information: They advance the gage and window numbers and display the results for reference windows #2 and #3, respectively. Subsequent page-downs return the block to the FAULT display and advance the gage and window numbers. The page-down function remains active until the last window or gage number appears.
Page 343
Chapter 10
Runtime Functions 70-79
Interpreting Run Mode Displays (continued)
Stat I Page If you picked the Stat 1 Page display selection, the Stat 1 Page will appear on the screen when you start the run mode, as follows:
GAGE
Samples
Mean
Std. Dev.
Min.Reading
Max. Reading
1. 2. 3. 4.
123 123
37.287 145.395
1.348 5.386
36.413 141.165
39.293 148.223
123
6.000
0.000
6.000
6.000
Samples
Mean
Std. Dev.
123 123 123
3245.245 181.662 11.000
32.399 3.542 0.000
WINDOW 1. 2. 3. 4.
MinReading
Max. Reading 3278.243 183.42 1 11.000
322 1.476 179.198 11 .ooo
The Stat 1 Page is a table that summarizes inspection results for all enabled gages and windows in whichever tool set is currently selected. It is updated at the end of each inspection, time permitting. Note in the display example above that no results data appear alongside gage #3 and window #4. The reason is that these tools are disabled. The number of gages and windows that appear in the Stat 1 Page depends on the selections that you make in the Disp. Windows, Disp. Gages, and Disp. Probe menu boxes in the Runtime Init. popup menu. The following tables show the maximum number of gages and/or windows that can be displayed in all combinations with the Disp. Probe display disabled and enabled. Light Probe Display disabled: Gages
0
0
0
1
2
3
4
5
6
7
8
9
10
11
12
Windows
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Light Probe Display enabled: Gages
0
0
0
1
2
3
4
5
6
7
8
9
Windows
9
8
7
6
5
4
3
2
1
0
0
0
Page 344
10-20
Chapter 10
Runtime functions - interpreting Run Mode Displays (continued)
Stat 1 Page (continued) If you pick the Disp. Windows (or Disp. Gages) menu box, then pick the Help symbol, the help message box will show the current maximum number of windows (or gages) whose results data can be displayed in the Stat 1 Page. The PROBE, GAGE and WINDOW sections all show the number of inspections performed, the mean “reading” or measurement, the standard deviation, the minimum reading, and the maximum reading for the enabled probe and for each enabled gage and window. Note that you can scroll this page using the Page J and Page t menu boxes, as with the Results page, above. Note also that you can reset the statistics to zero by picking the Reset Stat‘s menu box. Stat 2 Page If you picked the Stat 2 Page display selection, the Stat 2 Page will appear on the screen when you start the run mode, as follows: REFERENCEWINDOWSTATISTICS Samples
Mean
Std. Dev.
Max. Reading
Min.Reading
1.1 1.2 1.3
1234 1234 1234
0.406 0.675 0.105
2.031 3.467 0.542
12 19 3
36 57 10
2.1 2.2 2.3
1234
,746
1.334
6
20
3.1 3.2 3.3
The Stat 2 Page is a table that summarizes inspection results for all enabled reference windows.in whichever tool set is currently selected. The Stat 2 Page is updated at the end of each inspection, time permitting. This table shows the number of inspections performed, the mean “reading” or measurement, the standard deviation, the minimum reading, and the maximum reading for each of the three features in each enabled reference window. Blank lines indicate a disabled reference window or an inactive feature. Note that you can reset the statistics to zero by picking the Reset Stat’s menu box.
-
Page 345
Chapter
10 Runtimefunctions
IO-21
If you are using both tool sets, you can alternately display the two tool sets by picking the Display TS menu box successively.
Displaying Other Tool Set
When you pick the menu box, the current tool set number appears in the box. Thus, Display TS 1 becomes Display TS 2, and vice versa. Note that the image will also change if the other tool set uses the second camera.
To use the halt and/or freeze functions, you can enable and “arm” these functions in the Runtime lnit popup menu, as explained earlier.
Using Run Mode Halt and Freeze Functions
You can also arm the enabled freeze or halt function by picking the Arm menu box in the Runmode menu and pick the appropriate arm selection, as follows: Reset Stat’s
~~::’ Display
-
LOO
:
$&j:&j
1::
:!.:
.::
i. ::
q Freeze q Freeze 1st Rej
All Rej’s q Freeze Next lnsp
0
Halton Reject
:
Note that the five arm selections appear in boxes alongside the Arm menu box. The Go on Reject selection is darkened, indicating that the Go on Reject function is currently enabled. This means that the system will perform inspections and update the screen image regardless of the occurrance of a reject condition. If the halt or freeze function is disabled (in the Runtime lnit menu), you will not be able to pick the corresponding arm box. This is indicated by the black lettering in the box(es). To arm the halt function or one of the freeze functions, pick the appropriate arm box. Once you have armed the halt and/or freeze function, the system will respond when the iven condition occurs. For example, if you have enabled ta e freeze function and then pick the Freeze 1st Rej box, the system will freeze the screen image and tool status when a reject condition from any tool occurs. The system will continue inspections when the freeze function is enabled and armed, and will halt inspections when the halt function is enabled and armed. If you want to resume normal inspection operations after a freeze or halt occurs, pick the Resume box. The system will continue normal inspection operations until the next freeze or halt condition occurs. If you want to disarm halt or freeze conditions (without disabling these functions in the Ru ntime I nit menu), pick the Go on Reject box.
Page 346
Chapter 10
Runtime Functions
1o-22
Using Run Mode Halt and Freeze Functions (continued)
NOTE: If you return to the setup mode with a “frozen” or “halted” image on the monitor screen, and the camera resolution is set to 512H x 512V, any “learn” operation you perform on the frozen or halted image may produce a different result than is indicated on the Results Page. See Chapter 5, Camera and Lighting Parameters, for more information.
-
-