Page 301

Chapter

Configuration Aids and Storage 9 Functions

Chapter Objectives

This chapter shows you how to use the configuration aids and the configuration storage and retrieval functions in the M isc popup menu. This menu appears when you pick the M isc menu box in the Main Configuration menu.

uration Akk and

The following functions enable you to store and retrieve configurations and help you adjust the stored configurations to changes that may occur in workpiece position.

COnfi

S&age:

Overview l Archive:

The CVIM system can store and retrieve configurations and screen images using either its internal non-volatile memory or a plug-in, credit card-sized, batterybacked random access memory (RAM card). Separately, the CVIM system can also send (upload) configurations to computer or PLC equipment, and then receive (dowrzloczd) those same configurations later, during runtime operations. Since these functions involve data communications, they are described in the CVI-M Communications Manual, Catalog No. 5370-ND002. l Snapshot:

This function provides a convenient way to acquire a single camera image or display the test pattern.

,- l Analysis:

This function calculates the elapsed time that the system requires to perform an inspection operation for one or more analysis tools. l Registration:

This function provides a convenient way of re-registering inspection tools to a workpiece when the workpiece position has been moved from its original location in the camera image. All of these functions are in the M isc popup menu, which you can access after picking the Mix menu box in the Main Configuration menu.

Using

Configuration Ai& and Storage Functions

This section shows you the details of selecting and using the configuration aids and storage functions. You will pick the Mist menu box in the Main Configuration menu, which will display the M isc popup menu. You can then select a configuration aid or storage function from one of the menu boxes in the M isc popup menu. The menu boxes correspond to the four functions listed in the overview.

Page 302

Chapter

9

Configuration

Aids and Storage Functions

9-2

Selecting

Mist Popup Menu

Your first step is to select the M isc popup menu.

Your Action

Comments When you pick the Mist menu box, the Mist popup menu appears above the Main Configuration menu, as follows:

Pick Mis’c in the Main Configuration menu.

..a

Archival

Env.

Selecting

Archival

-

Camera A

Ref. Line

Ref. Win

Gage

Window

Select the Archival popup menu, then select the appropriate configuration storage or retrieval function.

Popup Menu

Comments

Your Action Pick the Archival menu box in the Mist popup menu.

When you pick the Archival menu box, the Archival popup menu appears above the Mist popup menu, as follows:

ISet Archive Names

-

0.0

Load Default Config

Load From Card

Format Card

Archival Popup Menu

0.0

IShow Card Status

I

Snapshot

0.0

Analysis l.e

IRegistration leo

1 +-

Env.

Camera A

Ref. Line

Mist Popup Menu

Ref. Win

Gage

-

Window ii$ic::’

Page 303

Chapter

9

Configuration

Aids and Storage functions 9-3

Selecting

Archival Popup Menu (continued)

From the top down, these are the functions in the Archival popup menu: Names: When you pick this function, you can give a name to the current configuration and screen image. The name can contain up to 16 characters consisting of any mix of alphanumeric, punctuation, and other characters. l Set Archive l Load Default Config: When you pick this function, the default configuration overwrites the current configuration.

(Int): When you pick this function, the Config. previously stored configuration is retrieved from the nonvolatile, random access memory (EEPROM) in the CVIM module. l Load

(Int): When you pick this function, the current configuration is stored in the EEPROM. l Save Config.

From Card: When you pick this function, the previously stored configuration or image data is retrieved from a RAM card, which can be inserted in the Archive Memory slot on the CVIM module front panel.

l Load

Card: When you pick this function, the current configuration or image is stored in the RAM card.

l Save to

From Card: When you pick this function, you can delete any of the stored configuration(s) and/or image(s) from the RAM card.

l Delete

-

Card: When you pick this function, the RAM card is reformatted for storing either configuration or image data. Previous data is overwritten by the default values. l Format

This function is accessible only when you insert a RAM card containing configurations or images from an earlier CVIM revisions. When you pick this function, the earlier configurations or images are converted to the current CVIM revisions.

l Convert:

Battery: When you pick this function, the RAM card receives power from the CVIM module, thereby enabling you to replace the battery without losing data.

l Replace

Card Status: When you pick this function, a message appears on the monitor screen showing the RAM card status.

l Show

In the next several steps, select the storage or retrieval function or the card-formatting function from the Archival popup menu.

Page 304

Chapter

9

Configuration

Aids and Storage Functions

9-4

Selecting

Archival Popup Menu (continued)

Using

Set Archive Names function

Use this function to name the current configuration and/or current screen image. You can choose any name consisting of up to 16 alphnumeric, punctuation, and miscellaneous printable characters, including the “space” character. Your Action Pick the Set Archive Names menu box, i,fappropriate.

Comments When you pick the Set Archive Names menu box, the Format Card popup menu will appear alongside the Archival popup menu, as follows:

Image: The Set Archive Names popup menu is shown as it appears when no names have been assigned. Pick the Coinfig or Image menu box, as appropriate, to assign a new name.

When you pick the Config or Image menu box, a “typewriter keyboard” will appear on the screen, as follows:

The space above the keyboard is shown as it appears when no names have been assigned. If a name had been assigned, it would appear after Current name. When you enter a new name, it will appear after New name.

-

Page 305

Chapter

Selecting

Archival Popop Menu (continued)

9

Aids and Storage Functions

Configuration

Using Set Archive Names Function

Your Action

9-5

(continued)

Comments The keyboard has five function keys: 1. The backspace key (+-) erases the last character entered and moves the cursor (A) left one space. 2. The Esc (“escape”) key returns to the Set Archive Names popup menu without changing the current name, if any. 3. The shift keys ( t J ) cause several of the keyboard characters to change between “upper case” and “lower case” characters. The alphabet characters, however, remain in upper case form. The preceding keyboard illustration shows the “lower case” character set, while the following illustration shows the “upper case” character set.

I

I

I!

p~#~$~%~-~&~*~

(111 -

QWERTYUI

OP{}Ret

A

S

D

F

G

H

J

K

L

+ c- Cl

:

u

1

1~

4. The Cl (“clear”)

key sets the New name line to all blanks.

5. The Ret (“return”) key enters the new name into the appropriate menu box in the Set Archive Names popup menu. Pick each character of the new name. Pick the Ret key to enter the new name.

As you pick the characters, they will appear after New name. When you pick the Ret key, the new name will appear in the appropriate menu box in the Set Archive Names menu, as follows.

I Config:

Speedometer

Cal. I

1 Image:

Speedometer

Dial

I

Page 306

Chapter

9

Configuration

Aids and Storage Functions

9-6

Selecting Archival Popup Menu (continued)

Using Save Config.

-

(Int) Function

Use this function to store the current configuration (located in the CVIM system RAM) in the CVIM module’s EEPROM. Your Action Pick the Save Config. (Int) menu box, >ifappropriate.

Comments When you pick the Save Config. (Int) menu box, the CVIM system will store the current configuration in the EEPROM. The following message appears in the message box at the upper-left part of the screen:

Saving Configuration

This indicates that configuration storage is under way.

After a moment, the following message appears in the message box:

Configuration

Saved

This indicates that configuration

Using Load Config.

storage is finished.

(Int) Function

Use this function to load the configuration stored in the CVIM module’s EEPROM into the CVIM system RAM. Your Action Pick the Load Config. (Int) menu box, if appropriate.

Comments When you pick the Load Config. (Int) menu box, the following message appears in the message box: WARNING: Loading a new configuration will destro the current confi uration. Reselect to con Yirm and begin loa %. This message is intended to inhibit overwriting the current configuration unintentionally. If you are certain that you are ready to load the stored configuration, continue.

Page 307

Chapter

Selecting Archival Popup Menu (continued)

9

Configuration

Using Load Config.

Your Action Pick the Lolad Config. (Int) menu box again, if appropriate.

Aids and Storage Functions

9-7

(Int) Function (continued)

Comments When you pick the Load Config. (Int) menu box again, the CVIM system will retrieve the configuration stored in the EEPROM. This configuration will overwrite the current configuration. The following message appears in the message box:

loading

Configuration

This message indicates that configuration way.

loading is under

After a moment, the following message appears in the message box:

Configuration

Loaded

This message indicates that configuration finished.

loading is

Using Load Default Config function Use this function to load the default configuration, stored in the CVIM module’s ROM. Your Action Pick the Load Default Config menu box, if appropriate.

which is

Comments When you pick the Load Default Config menu box, the following message appears in the message box: WARNING: Loading a new configuration will destro the current confi uration. Reselect to con Yirm and begin loa 3 . This message is intended to inhibit overwriting the current configuration unintentionall . If you are certain that you are ready to load the default con tquration, continue.

Page 308

Chapter

9

Configuration

Aids and Storage Functions

9-8 -

Selecting Archival Popup MeIn u (continued)

Using Load Default Config function (continued)

Your Action Pick the Load Default Config menu box again, if appropriate.

Comments When you pick the Load Default Config menu box again, the default configuration will begin loading. The default configuration will overwrite the current configuration. The following message appears in the message box:

Loading Configuration

This message indicates that the default configuration loading is under way. After a moment, the following message will appear in the message box:

Configuration

Loading -

This message indicates that the default configuration loading is finished.