The text of a manual · part 6 of 42
Bulletin 5370 CVIM Configurable Vision Input Module User Manual: 4 - Operating Environment, pages 57 to 66
Pages 57 to 66 of 390, from Bulletin 5370 CVIM Configurable Vision Input Module User Manual
The original document is the PDF (26 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 5370-CVIM
Page 57
Chapter
4
Operating Environment 4-71
Selecting
I/O Popup
Menu
Assigning
Output
Line Functions
(continued)
and Parameters (continued)
Comments
Your Action Pick the l/Duration box to set the pulse duration for tool set #I signals.
When you pick the l/Duration box, the “calculator” pad will appear alongside the Output Assignment popup menu, as follows:
I
Output Assignment Popup Menu
Calculator Pad
1
11 NotUsed
0.0
Not Used I 12~~~ I 13 Not Used
0.0
I
0.0
I
14 Not Used (
On the calculator pad, pick the appropriate pulse duration for tool set #1 signals. Pick the Enter key on the calculator pad.
Enter
Refer to the II0 Parameters table in Appendix B for the pulse duration you selected for tool set #l signals. When you pick the new pulse duration number, it will appear in the calculator “display.” When you pick the Enter key, the number you entered will appear in the l/Duration box.
If appropriate, repeat the sameprocess to set thepulse duration for tool set #2 signals. Before you connect the CVIM II0 lines to your production equipment, read this warning.
-
A t 0
WARNING: The CVIM local I/O lines will be disabled whenever hardware or software faults occur in the CVIM module and/or other modules in the Pyramid Integrator chassis. Failure to accommodate this logic convention when you interface the CVIM I/O lines to your production equipment may cause unintended operation of your equipment, which may result in serious personal injury or death.
Page 58
Chapter
4
Operating Environment
4-72
Selecting RS-232 Parameters
Selecting I/O Popup Menu and Parameters
If your application will be using the RS-232 port for data communication, you must select the appropriate RS-232 parameters.
(continued)
For additional information on CVIM data communications, refer to the CVIM Communications Manual, Catalog No. 5370-ND002. Your Action
Comments
Pick the RS-232 menu box in the I/Opopup menu.
When you pick this box, the RS-232 popup menus appear alongside the I/O popup menu, as follows:
RS-232 p/popup
Menus
@: ya: ; : :;: ;. ‘:. :
Popup Menu v Output Assignment
L
000
1
( f-J 9600
I
10 19200
]
System l .e
.!.‘:~&$’ .: Camera A
Ref. Line
Ref. Win
Gage
Window
Mist
Exit
Note that the ASCII box in the Protocol menu and the 300 box in the Baud Rate menu has a shaded square (0) This indicates that the RS-232 port is currently configured to use ASCII data communications protocol at 300 baud. In the Protocol popup menu, the selections indicate the two RS-232 data communications protocols available with the CVIM system. - This indicates that the CVIM system uses standard ASCII characters for data communications through the RS232 port.
l ASCII
- This indicates that the CVIM system uses the AllenBradley DFl protocol for data communications through the RS-232 port. l DFl
Page 59
4
Chapter
OperatingEnvironment 4-13
-
Selecting I/O Popup Menu and Parameters
Selecting RS-232 Parameters (continued)
(continued)
Comments
Your Action Pick the appropriate protocol in the Protocol menu. Pick the appropriate baud rate in the Baud Rate menu.
Selecting 177 1 Remote I/O Parameters If your application will be using the remote I/O port for data communication, you must select the appropriate remote I/O parameters. For more information about CVIM data communications, refer to the CV1M Communications Manual, Catalog No. 5370-ND002. Your Action
Comments
Pick the 1771 Remote I/O menu box in the I/O popup menu.
When you pick this box, the 177 1 Remote I/O popup menus appear alongside the I/O popup menu, as follows:
1 IJ Disabled
System
I Ref. Line
Ref. Win
Gage
Window
Mist
Exit
Note that the Enabled box in the Remote I/O menu and the 57.6 box in the Data Rate menu have a shaded square (0) This indicates that the remote I/O port is currently enabled for data communications at 57.6K baud. Also, the number 7 in the Rack Address menu indicates the CVIM is currently selected as the 1771 rack address.
Page 60
Chapter
4-14
Selecting
4
Operating
Selecting
I/O Popup Menu and Parameters
Environment
177 1 Remote I/O Parameters
(continued)
(continued)
Comments
Your Action
Pick Ena bled to enable using the remote I/O port. Otherwise, pick Disabled.
Pi& Ena bled or Disabled in the Remote I/O menu. Pick the appropriate baud rate in the Data Rate menu. Look at the address number in the Rack Address menu.
If the current rack address number is correct, next step.
If appropriate, pick the menu
When you pick the menu box, the “calculator” pad will appear alongside the 177 1 Remote I/O popup menus, as follows:
box in the Rack Address menu.
10
Disabled skip the
1
Calculator Pad
I/O Popup Menu I I
+ t Output
,
Assignment l .e
Data Rate
I
I
1 q 115.2
10 230.4
7
8
9
4
5
6
1
2
3
0
.
I
1System v +
-
% x
/
= t
Clr
:
Ref. Line
Ref. Win
Gage
Window
Mist
Enter
Exit
On the calculator pad, pick the appropriate rack address.
The new number will appear in the calculator “display.” Note that the acceptable address numbers are 0 through 7.
Pick the Enter key on the calculator pad.
When you pick the Enter key, the new address will appear in the Rack Address menu.
Page 61
Chapter
4
Operating
Environment 4-15
Select the Tool Set popup menu, then select the appropriate combination of cameras, tool sets, and trigger sources.
Selecting Tool Set Popup Menu and Parameters
Comments
Your Action
When you pick the Tool Set menu box, the three-part Tool Set popup menu will appear above the Env. popup menu, as follows:
Pick the Tool Set menu box in the Env. popup menu.
Trigger
Source
Trigger
Source
Active Tool Set:
l .e
1
System
.‘.I.
:
;; :Erfv;
:
: Camera A
Ref. Line
Ref. Win
Gage
Window
Mist
Exit
In the three-part Tool Set popup menu, the top two parts pertain to the camera and trigger source parameters for tool sets #l and #2. The bottom part determines the active tool set number during configuration. The three parts of the Tool Set menu have the following meanings: Set 1 - In this part you can select either camera A or B as the image source for the tool set # 1 analysis tools. In addition, you can select a tool set #l trigger source for configuration and for runmode.
l Tool
Set 2 -This is identical to Tool Set 1, except that it applies to tool set #2.
l Tool
0 Active Tool Set - In this part you can select the tool set and camera image that will appear on the monitor screen during configuration. The number will be either 1 or 2 for tool set #l or tool set #2.
Page 62
Chapter
4
Operating
Environment
4-16
Selecting Tool Set Popup Menu and Parameters (continued)
Selecting Tool Set # 1 Camera and Trigger Select camera A or B, then select the trigger source popup menus for tool set # 1. Comments
Your Action Look at the Camera menu box under Tool Set 1.
This box indicates the currently selected camera (A or B) whose image will be used with tool set #l.
If appropriate, pick the
When you pick the Camera menu box, the letter A will toggle to B, or vice versa. At the same time, the image on the monitor screen will change from one camera to the other, and a new image will be acquired.
Pick the Trigger Source menu box under Tool Set 1.
When you pick the Trigger Source menu box, the Runtime and Setup menus appear alongside the Tool Set popup menu, as follows:
Camera menu box.
Tool Set Popu Menu P
10
= RuntimeTrigger
Camera B - . I rigger Source Active Tool Set:
0.0
’
4
Source
POPUP Menus
1
.;:,:; :::I:.: j:. ;j:::E’&jj z:.: Camera A ::
T”:,,..” Illyyer
Ref. Line
Ref. Win
Gage
Window
Mist
Exit
Note that the None/Disabled box in the Runtime menu and the Auto/Internal box in the Setup menu has a shaded square (0) This indicates that the tool set #l run mode currently has no trigger source enabled, and the configuration (“Setup”) mode has th e automatic internal trigger enabled. Note also that the 2 (Auto/Internal), 2 (l/O), and 2 (Hosted) boxes are in black type, indicating that you cannot pick them at this time. (They will be enabled when you pick the Trigger Source menu box under Tool Set 2.)
1
Page 63
Chapter
Selecting Tool Set Popup Menu and Parameters
4
Operating Environment
4-17
Selecting Tool Set # 1 Camera and Trigger (continued)
(continued)
Comments
Your Action
In the Runtime popup menu, the selections in the menu boxes have the following meanings: l None/Disabled - This indicates that no trigger source will be enabled during the run mode. l 1 (Auto/Internal) - This indicates that the trigger source for tool set #l will be the CVIM module’s internal circuitry. The trigger period will be one trigger pulse every 50 milliseconds, f 5. This is an approximate rate of 20 trigger pulses per second.
NOTE: If you select 1 (Auto/Internal) for tool set #l, you can &so select 1 (Auto/Internal) for tool set #2. l 1 (l/O) - This indicates that the trigger source will be the #l trigger input through the CVIM module front panel. NOTE: If you select 1 (I/O) for tool set # 1, you can also select 1 (I/O) for tool set #2. - This indicates that the trigger source will be the #l host system trigger input through the backplane (Pyramid system), through the remote I/O port, or through the RS-232 port (computer system).
l 1 (Hosted)
-
NOTE: If you select 1 (Hosted) for tool set #l, you can also select 1 (Hosted) for tool set #2. 2 (l/O), and 2 (Hosted) - These are in black type, indicating that you cannot select them at this time.
l 2 (Auto/Internal),
The selections in the Setup popup menu apply only during CVIM system configuration. They have the following meanings: - This is the same trigger source described in 1 (Auto/Internal), above. When enabled, it ensures that a “live” camera image will appear on the monitor screen durin the following functions: Focus Camera, Take Snapsfi ot, Light Reference, Snap 81Analyze, Continuous S&A, Snap & Register, and Continuous S&R.
l Auto/Internal
= Runtime Trigger - At various times during tool configuration, new camera images may be required to be synchronized with moving workpieces. By selecting the = Runtime Trigger box, you can use the run node I/O trigger source to acquire synchronized images during tool configuration. In this case, the CVIM system will ulait for the trigger signal to acquire each new image.
l
Page 64
Chapter
4
Operating Environment
4-78
Selecting Tool Set Popup Menu and Parameters (continued)
Selecting Tool Set #2 Camera and Trigger If your application requires using tool set #2, select camera A or B, then select the trigger source popup menus for tool set #2. Comments
Your Action Look at the Camera menu box under Tool Set 1.
If appropriate, pick the Camera menu box.
Pick the Trigger Source menu box under Tool Set 2.
This box indicates the currently selected camera (A or B) whose image will be used with tool set #2. When you pick the Camera menu box, the letter A will toggle to B, or vice versa. At the same time, the image on the monitor screen will change from one camera to the other, and a new image will be acquired. When you pick the Trigger Source menu box, the Runtime and Setup menus appear alongside the Tool Set popup menus, as follows: Tool Set
10
1 (Auto/Internal)
0
1 (Hosted)
I
Active Tool Set: 1System
0.0
I 1q 2 (Hosted)
+.
.ine
Env. Popup Menu Ref. Win
Gage
Window
II SC Mi
Note that the 2 Auto/Internal box in the Runtime menu and the = Runtime Trigger box in the Setup menu have a shaded square (01 This indicates that the run mode for tool set #2 currently uses the automatic internal trigger source, and the configuration (“Setup”) mode use the same trigger source as the run mode. Note also that the 1 (Auto/Internal), 1 (l/O), and 1 (Hosted) boxes are in black type, indicating that you cannot pick them at this time. (They will be enabled when you pick the Trigger Source menu box under Tool Set 1.)
-
Page 65
Chapter
4
Operating Environment 4-19
Selecting Tool Set Popup Menu (and Parameters
Selecting Tool Set #2 Camera and Trigger (continued)
(continued)
Comments
Your Action
The selections in the Runtime popup menu apply only during CVIM system run mode. They have the following meanings: - This indicates that FXO trigger source will be enabled during the run mode.
l None/Disabled
- This indicates that the trigger source for tool set #2 will be the CVIM module’s internal circuitry. The trigger period will be one trigger pulse every 50 milliseconds, + 5. This is an approximate rate of 20 trigger pulses per second.
l 2 (Auto/Internal)
l 2 (l/O) - This indicates that the trigger source will be the #2 trigger input through the CVIM module front panel. - This indicates that the trigger source will be the #2 host system trigger input through the backplane (Pyramid system), through the remote L’O port, or through the RS-232 port (computer system).
l 2 (Hosted)
l 1 (Auto/Internal),
-
1 (l/O), and 1 (Hosted) - These are in black type, indicating that you cannot select them at this time.
The selections in the Setup popup menu apply only during CVIM system configuration. They have the following meanings: - This is the same trigger source described in 2 (Auto/Internal), above. When enabled, it ensures that a “live” camera image will appear on the monitor screen during the following functions: Focus Camera, Take Snapshot, Light Reference, Snap & Analyze, Continuous S&A, Snap & Register, and Continuous S&R. l Auto/Internal
0 = Runtime Trigger - At various times during tool’ configuration, new camera images may be required to be synchronized with moving workpieces. By selecting the = Runtime Trigger box, you can use the run mode I/O trigger source to acquire synchronized images during tool configuration. In this case, the CVIM system will wait for the trigger signal to acquire each new image.
Page 66
Chapter
4
Operating
Environment
4-20
Selecting Tool Set Popup Menu and Parameters (continued)
Selecting Active Tool Set During CVIM system configuration, the camera image and tool set that will appear on the monitor screen depend on the setting shown in the Active Tool Set menu box, the third part of the Tool Set popup menu. Set the Active Tool Set menu box according to which tool set you want to configure at this time.
Your Action Look at the Active Tool Set menu box.
Comments This box indicates the currently selected “active” tool set. If you want to configure tools in tool set #l, the menu box must display 1. If you want to configure tools in tool set #2, the menu box must display 2.
If appropriate, pick the Active
Tool Set menu box.
When you pick the Active Tool Set menu box, the tool set number will toggle from 1 to 2, or vice versa. At the same time, the image on the monitor screen will change from one camera to the other provided that you have selected different cameras under Tool Set 1 and Tool Set 2.