The text of a manual · part 34 of 42
Bulletin 5370 CVIM Configurable Vision Input Module User Manual: 9 - Configuration Aids and Storage Functions, pages 317 to 324
Pages 317 to 324 of 390, from Bulletin 5370 CVIM Configurable Vision Input Module User Manual
The original document is the PDF (26 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 5370-CVIM
Page 317
Chapter 9
-
Configuration Aids and Storage Functions
9-17
Selecting Analysis Popup
Menu
(continued)
Your Action
Comments Display: When you pick this function, a popup menu appears that enables you specify the particular tool(s) whose processing time you want displayed.
l Tool
Note that the Analysis menu “header” displays the following information: Process and Time = (t)ms: This indicates the processing time (t) in milliseconds for the specified tool(s).
l (Tool)
Using Tool Display Function Use this function to specify the particular tool(s) whose processing time you want the CVIM system to display. Your Action Pick the Tool Display menu box, if appropriate.
Comments When you pick the Tool Display menu box, the Tool Display popup menu will appear, as follows:
ISnap &Analyze
I
Analyze Image ~ .~~~~~::~~~~l~~~ : jj ..j-i:.:.:j.:;. g.;,.: i .... .A. ..I... ,: ,:iji*& :..:: : .: ; I: .A.. . .... .:... ,..:;.::
I0 No Tools
I
10 Ref. Lines
I0 Ref. Windows
Env.
Camera A
Ref. Line
Ref. Win
Gage
Window
I
I$[$iij
Note that the All Tools box is darkened, indicating currently selected tool display mode is All Tools.
-
Exit that the
Page 318
Chapter
9
Configuration
Aids and Storage Functions
9-18
Selecting Analysis Popup Menu (continued)
Using Tool Display Function (continued)
Comments
Your Action Pick the appropriate Tool Display menu box.
When you pick a Tool Display menu box, The CVIM system performs these functions: l Darkens the selected menu box.
l Displays the processing time for the selected tool(s).
l Displays the selected tool(s) over the image. The color of each tool shows whether it passed or failed the inspection.
l Displays the contents of the selected menu box in the “header” box of the Analysis popup menu.
NOTE: When you pick any of the next three analysis functions, you may see some slight variations in the displayed tool processing time. These variations can result from the specific timing of internal processing routines and from synchronization delays. The variations are typically small compared to tool processing times; thus, they should not adversely affect the usefulness these calculations have in helping you to estimate the processing times for your application.
Using Analyze
Image function
Use this function to display the processing time for the current camera image. Your Action Pick the Analyze Image menu box, ifappropriate.
Comments When you pick the Analyze Image menu box, the CVIM system uses the current stored camera image to display the inspection processing time, in milliseconds, in the “header” box in the Analysis popup menu.
Using Snap & Analyze
Function
Use this function to acquire a new camera image and display the processing time for the tool(s) that you have selected in the Tool Display popup menu. Your Action Pick the Snap &Analyze menu box, if’appropriate.
Comments When you pick the Snap & Analyze menu box, the CVIM system acquires a new camera image (takes a “snapshot”), then displays the inspection processing time, in milliseconds, in the “header” box in the Analysis popup menu.
Page 319
Chapter
9
Configuration
Aids and Storage Functions 9-19
Selecting
Analysis
Popup Menu (continued)
Your Action Pick the Continuous
S&A menu box, if appropriate.
Using
Continuous
S&A Function
Use this function to perform the Snap & Analyze continuously.
function
Comments When you pick the Continuous S&A menu box, the CVIM system continuously acquires a new camera image (takes a “snapshot”) and displays the inspection processing time, in milliseconds, in the “header” box in the Analysis popup menu. Also, the following message appears in the message box on the monitor screen:
Depress the lightpen to continue
The system repeats the “snap and analyze” process about every half second (if the auto/internal trigger source is enabled); however, the actual rate depends on the type and number of tools that are enabled and the trigger selected. To end the function, use your finger to press light pen tip, or press the tip against the monitor screen. Hold the tip this way until the message box disappears.
Selecting
Registration
Popup Menu
Select the Registration registration functions.
popup menu, then select the
NOTE: In order to make use of this function, you must first configure at least one reference tool and then assign the inspection tools to the reference tool. The Registration function enables you to automatically realign inspection tools with a workpiece when the workpiece has been moved from its original position in the screen image. You can then saue the shifted tool positions and reconfigure them as needed.
Page 320
Chapter
9
Configuration
Aids and Storage Functions
9-20
Selecting Registration Menu (continued)
Popup
Comments
Your Action Pick the Regist.ration menu box in the Miscpopup menu.
When you pick the Registration menu box, the Registration popup menu appears above the M kc popup menu, as follows: Snap & Register
I
IContinuous S&R
I
IArchival
Env.
0.0
Camera A
Ref. Line
Ref. Win
Gage Window
..:.: ::: : ~,!j,!T&:~ ,,.. :,:...:.:,
From the top down, these are the functions in the Registration popup menu: & Register: When you pick this function, the CVIM system takes a “snapshot” and re-registers the tools to the new location of the workpiece in the screen image. l Snap
S&R: When you pick this function, the CVIM system will perform the Snap & Register function continuously. l Continuous to Image: When you pick this function, the CVIM system registers the tools using the current stored image.
l Register
Registration: When you pick this function, the CVIM system stores or “learns” the re-registered positions of the tools.
l Learn
Display: When you pick this function, a Tool Display popup menu appears. This menu enables you specify the particular tool(s) that you want the system to display.
l Tool
Page 321
Chapter
Selecthg POpUp
Configuration
Aids and Storage functions
9-2 1
Using Tool Display Function
Registration
/bfenu
9
(continued)
Use this function to specify the particular tool(s) that you want the CVIM system to display during the Snap & Register, Continuous S & R, and Register to Image functions. Tool displays are color coded to indicate the outcome of the Snap & Register, Continuous 5 & R, or Register to Image function. The colors have the following meanings: l Reference tools:
Green means that the reference tool found its selected feature. Yellozu means that the reference tool did not find its selected feature. Red means that the reference tool is assigned to another reference tool, and that reference tool did not find its selected feature. l Inspection tools:
Green means only that the inspection tool could be properly positioned within the screen image.
Yellour means that the inspection tool was positioned off the screen image. Red means that the inspection tool could not be positioned because the reference tool to which it is assigned could not find its selected feature. Your Action
Comments
Pick #theTool Display menu box, if appropriate.
When you pick the Tool Display menu box, the Tool Display popup menu will appear, as follows: Tool Display
IRegister to Image I
I
Learn Reg:~‘-.‘: --
IArchival
.a.
I- ~ l eo
-1 I+-
Snapshot
I 1Analysis
I
Env.
I
I
I Ref. Line I Ref. Win
I
I0 Ref. Lines
I
I 0 Ref. Windows
I
I
0 Gages 1q Windows
Men;
I
I c
Mist POWD
1Camera A
No Tools
I
,.
I
Gage
I
Window
;Mi+ ‘,.;:IExit
Page 322
Chapter
9
Configuration
Aids and Storage Functions
9-22
Selecting Registration Popup Menu (continued)
Using Tool Display Function (continued)
Comments
Your Action
Note that the All Tools box is darkened, indicating currently selected tool display mode is All Tools. Pick the ap.propriate Tool Display menu box.
that the
When you pick a Tool Display menu box, The CVIM system performs darkens the selected menu box and displays the selected tool(s) over the image.
Using Snap & Register Function Use this function to acquire a new camera image and register all inspection tools that you have assigned to reference tools. Your Action Pick the Snap & Register menu box, if appropriate.
Comments When you pick the Snap & Register menu box, the CVIM system performs these tasks: l It acquires a new camera image (takes a “snapshot”).
l It analyzes the enabled reference tools.
l It re-registers the inspection tools to their assigned reference tools. l It displays the tool(s) locations on the screen.
Using Continuous
S&R Function
Use this function to perform the Snap & Register function continuously. Your Action Pick the Continuous S&R menu box, if appropriate.
Comments When you pick the Continuous S&R menu box, the CVIM system continuously acquires a new camera image (takes a “snapshot”), registers the inspection tools to their assigned reference tools, and displays the new tool locations on the monitor screen. Also, the following message appears in the message box on the monitor screen:
Depress the lightpen to continue
The system repeats the “snap and register” process about every half second (if the auto/internal trigger source is enabled); however, the actual rate depends on the type and number of tools that are enabled and the trigger selected. To end the function, use your finger to press light pen tip, or press the tip against the monitor screen. Hold the tip this way until the message box disappears.
Page 323
Chapter
9
Configuration
Aids and Storage Functions 9-23
-
Selecting Registration Menu (continued)
Popup
Your Action Pick the Register to Image menu box, if appropriate.
Using Register to Image Function Use this function to register the tools using the current screen image. Comments When you pick the Register to Image menu box, the CVIM system uses the same stored camera image to register the inspection tools to the workpiece.
Using Learn Registration
Function
Use this function to “learn” the new tool locations if you want to modify the tool configurations in these locations. Your Action Pick the Learn Registration menu box, if appropriate.
Comments When you pick the Learn Registration menu box, the CVIM system stores the locations of the re-registered inspection, and thereby alters the previous configuration of these tools. NOTE: Window rotation cannot be ‘learned” for rectangular and elliptical windows. Only shift can be learned.
Page 324
-
-