Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 5 of 25

Bulletin 5370 CVIM Configurable Vision Input Module Communications Manual: 3 - Using Local I/O, pages 29 to 37

Pages 29 to 37 of 202, from Bulletin 5370 CVIM Configurable Vision Input Module Communications Manual

The original document is the PDF (723 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 5370-CVIM

Page 29

Chapter 3 Using Local I/O

Planning Output Line Connections

This section provides diagrams of electrical connections for correctly connecting your production equipment to the CVIM module’s discrete output and RS–232 lines.

Connections to RS–232 Ports (2801–N27 Interface Box)

Figure 3.6 shows the cable connectors and their pin numbers on the I/O Interface Box (Catalog No. 2801–N27). Figure 3.6 Pinouts– I/O Interface Box (Catalog No. 2801–N27)

5

P O R T

1

2

8

7

6

Cable connectors to RS–232 devices. C V I M

9

8

7 17

18 26

B

6 16

25

5 15

24

4 14

23

3 13

22

12 21

1

2 11 20

10 19

Cable connector from Module I/O connector on CVIM Module.

I/O Interface Box (Catalog No. 2801–N27)

3–10

3

9

P O R T A

4

Page 30

Chapter 3 Using Local I/O

Connections to RS–232 Port (2801–N21 Interface Box)

Figure 3.7 shows the cable connectors and their pin numbers on the I/O Interface Box (Catalog No. 2801–N21). Figure 3.7 Pinouts– I/O Interface Box (Catalog No. 2801–N21)

8

9 18

7 17

26

6 16

25

5

4

15 24

14 23

3 13

22

1

2 12

21

10

11 20

19

Cable connector from Module I/O connector on CVIM Module.

5

4 9

3 8

1

2 7

6

Cable connectors to RS–232 devices. I/O Interface Box (Catalog No. 2801–N21)

3–11

Page 31

Chapter 3 Using Local I/O

CVIM Module I/O Interface Box Connections

Tables 3.A through 3.H show the connector pin assignments with the various combinations of Series A and Series B CVIM modules connected to I/O Interface Boxes (Catalog Nos. 2801–N21, –N27) . Table 3.A CVIM Module I/0 Connector: Series A CVIM Module

3–12

Pin Number

Function

Pin Number

Function

1

Trigger Input Line #1

14

Output Line #12

2

Trigger Input Line #2

15

Output Line #13

3

Output Line #1

16

Output Line #14

4

Output Line #2

17

Reserved

5

Output Line #3

18

Reserved

6

Output Line #4

19

Ground (Power)

7

Output Line #5

20

Ground (Power)

8

Output Line #6

21

Ground (Chassis)

9

Output Line #7

22

Ground (Signal)

10

Output Line #8

23

TXD (Transmit Data: RS–232 A)

11

Output Line #9

24

RTS (Request to Send: RS–232 A)

12

Output Line #10

25

RXD (Receive Data: RS–232 A)

13

Output Line #11

26

CTS (Clear to Send: RS–232 A)

Page 32

Chapter 3 Using Local I/O

Table 3.B CVIM Module I/0 Connector: Series B CVIM Module Pin Number

Function

Pin Number

Function

1

Trigger Input Line #1

14

Output Line #12

2

Trigger Input Line #2

15

Output Line #13

3

Output Line #1

16

Output Line #14

4

Output Line #2

17

Reserved

5

Output Line #3

18

Reserved

6

Output Line #4

19

Ground (Power)

7

Output Line #5

20

Ground (Power)

8

Output Line #6

21

Ground (Chassis)

9

Output Line #7

22

Ground (Signal)

10

Output Line #8

23

TXD (Transmit Data: RS–232 A)

11

Output Line #9

24

TXD (Transmit Data: RS–232 B)

12

Output Line #10

25

RXD (Receive Data: RS–232 A)

13

Output Line #11

26

RXD (Receive Data: RS–232 B)

Table 3.C I/O Interface Box (Catalog No. 2801–N21): RS–232 Connector with Series A CVIM Module Pin Number

Function

Pin Number

Function

1

No Connection

6

No Connection

2

RXD (Receive Data: RS–232 A)

7

RTS (Request to Send: RS–232 A)

3

TXD (Transmit Data: RS–232 A)

8

CTS (Clear to Send: RS–232 A)

4

Ground (Chassis)

9

No Connection

5

Ground (Signal)

Table 3.D I/O Interface Box (Catalog No. 2801–N21): RS–232 Connector with Series B CVIM Module Pin Number

Function

Pin Number

Function

1

No Connection

6

No Connection

2

RXD (Receive Data: RS–232 A)

7

TXD (Transmit Data: RS–232 B)

3

TXD (Transmit Data: RS–232 A)

8

RXD (Receive Data: RS–232 B)

4

Ground (Chassis)

9

No Connection

5

Ground (Signal) 3–13

Page 33

Chapter 3 Using Local I/O

CVIM Module I/O Interface Box Connections (cont’d)

Table 3.E I/O Interface Box (Catalog No. 2801–N27) RS–232 Port A Connector Series A CVIM Module Pin Number

Function

Pin Number

Function

1

No Connection

6

No Connection

2

RXD (Receive Data: RS–232 A)

7

+ 5V DC

3

TXD (Transmit Data: RS–232 A)

8

No Connection

4

+ 5V DC

9

No Connection

5

Ground (Signal)

Table 3.F I/O Interface Box (Catalog No. 2801–N27): RS–232 Port B Connector Series A CVIM Module Pin Number

Function

Pin Number

Function

1

No Connection

6

No Connection

2

CTS (Clear to Send: RS–232 A)

7

+ 10V DC

3

RTS Request to Send: RS–232 A)

8

No Connection

4

+ 10V DC

9

No Connection

5

Ground (Signal)

Table 3.G I/O Interface Box (Catalog No. 2801–N27): RS–232 Port A Connector Series B CVIM Module

3–14

Pin Number

Function

Pin Number

Function

1

No Connection

6

No Connection

2

RXD (Receive Data: RS–232 A)

7

+ 5V DC

3

TXD (Transmit Data: RS–232 A)

8

No Connection

4

+ 5V DC

9

No Connection

5

Ground (Signal)

Page 34

Chapter 3 Using Local I/O

Table 3.H I/O Interface Box (Catalog No. 2801–N27): RS–232 Port B Connector Series B CVIM Module

Connections to 1771–JMB Interface

Pin Number

Function

Pin Number

Function

1

No Connection

6

No Connection

2

RXD (Receive Data: RS–232 B)

7

+ 10V DC

3

TXD (Transmit Data: RS–232 B)

8

No Connection

4

+ 10V DC

9

No Connection

5

Ground (Signal)

The 1771–JMB interface board is designed for direct edge connection to the I/O Interface Box, Catalog Nos. 2801–N21, –N27. If you intend to use the 1771–JMB board and the I/O Interface Box, you will need to know the relationship between the discrete I/O line numbers and the LED numbers, the optic–isolator type, and the terminal block screws numbers on the 1771–JMB board. These are shown in the figure and table that follows. To power the JMB logic components, you must connect an external +5VDC power supply to the (+) and (–) terminals screws shown in the board layout Figure 3.5.

3–15

Page 35

Chapter 3 Using Local I/O

Connections to 1771–JMB Interface (cont’d)

Figure 3.8 shows the layout of the 1771–JMB interface board and the adhesive–backed overlay. Figure 3.8 Local I/O Board ( Catalog No. 1771–JMB).

CVIM Module Overlay

ËËËËËËËËËË ËËËËËËËËËË ËËËËËËËËËË Teminal screws for external +5VDC power supply

+ –

1

Out

2

3

Out

3

4

Out

4

5

Out

5

6

Out

6

7

Out

7

8

Out

8

9

Out

9

10

Out

10

11

Out

11

12

Out

13

13

Out

13

14

Out

14

15

Out

7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Not Used

1 2 3 4 5 6

2

2

3–16

In

1

O U T P U T S

1

0

T R I G G E R S

Page 36

Chapter 3 Using Local I/O

Table 3.I shows the relationship between the I/O line and optic–isolator numbers shown in Figure 3.8. Table 3.I Output Numbering Discrete I/O Line Number

Terminal Screw and Polarity

LED and I/O Module Number

+

–

1

0

1

2

2

1

3

4

1

2

5

6

2

3

7

8

3

4

9

10

4

5

11

12

5

6

13

14

6

7

15

16

7

8

17

18

8

9

19

20

Input

Output

9

10

21

22

10

11

23

24

11

12

25

26

12

13

27

28

13

14

29

30

14

15

31

32

Note: A self–adhesive decal (Part Number 40062-149-01) is provided with the 1771–JMB Local I/O board. This decal identifies the I/O lines. Use the chart on the next page if the decal is not in place.

3–17

Page 37

Chapter 3 Using Local I/O

OUTPUT LINE PLANNING SHEET Output Line Functions and Assignments

Line No.

3–18

Output Line Function

Gage No.

Rng.

Reference Tool

Window No.

Rng.

No.

Rng.

No.

Rng.

Line

Win.

Light Probe Red

Green

Blue