Page 171

Section 4B Connecting the 3-axis Servo Module

4B.4 Wiring a Touch Probe to the Digital Servo Module

A touch probe can be interfaced with the digital servo module through connector CN9. Refer to Figure 4B.5 for the location of connector CN9 on the digital servo module. Touch probe cable information can be found on page 7A-38. The time delay between the servo module receiving the touch probe trigger and latching the current axis position is considered negligible. However, you should take into account any external delays that can introduce position “staleness” in the probing operation, especially at high probing speeds. It is a good idea to establish an offset for the distance between the actual location, as sensed by the touch probe at a very low speed, and the location sensed by the touch probe at the intended probing speed. The offset can then be added or subtracted to any future values obtained through probing. This helps insure that if there are any external delays in the trigger signal, the position staleness shows up as a constant position offset error and is removed from the measurement (assuming the external delay is repeatable). The motion controller touch probe interface is intended for use with units that offer 5V dc compatible solid state relay outputs (see Figure 4B.23). Other configurations can be supported as long as the user operates within the published electrical specifications. The touch probe circuitry resident on the servo module only responds to the trigger probe edge changes. Polarity transition (high to low or low to high) is programmable through the AMP parameter Probe Transition Specify the probe transition in AMP as rising edge or falling edge. Once the active edge occurs, position data is captured by the module, and additional occurrences of the trigger signal have no effect until the probe is reenabled under program control. Refer to the 9/Series CNC 9/230, 9/260 and 9/290 AMP Reference Manual, publication 8520-6.4, for more information. ATTENTION: It is preferred, from a safety standpoint, that the touch probe relay be closed at rest and open when the touch probe stylus deflects. Then, if a wire breaks or shorts to ground, it will appear to the system as a probe fired and the probing cycle in process will stop commanding motion towards the part. The user should make every effort to insure fail-safe operation of the touch probe. Not all vendors of touch probe control units conform to this safety consideration.

4B-25

Page 172

Section 4B Connecting the 3-axis Servo Module

Figure 4B.23 shows the internal servo module circuitry that interfaces to the touch probe connector. It is shown here to assist you in determining whether your touch probe hardware is compatible. Figure 4B.23 Internal Circuitry Supporting the Touch Probe +5 V dc

Servo Module 470 ohm 1000 ohm

26LS32

5V common

1 2 3 4 5 6 7 8

CN9M

11296-I

The following table indicates probing threshold voltages. Maximum Input Threshold (critical if the control has been configured to fire on the falling edge of the probe signal) indicates the voltage that the probe signal must fall below to be considered as “fired”. Minimum Input Threshold (critical if the control has been configured to fire on the rising edge of the probe signal) indicates the voltage that the probe signal must rise above to be considered as fired. Probe Thresholds

Voltage at Threshold

Minimum Input Threshold (probe circuit)

3.06V dc (min)

Maximum Input Threshold (probe circuit)

2.18V dc (max)

To guard against misfires use the threshold values from the above table to determine the necessary signal voltage for steady state operation (probe not fired). For probes configured to fire on the falling edge the steady state voltage must remain above 3.06 volts. For probes configured to fire on the rising edge the steady state voltage must remain below 2.18 volts.

Wiring a Probe for Rising Edge Configurations Typical wiring of a simple contactor type touch probe configured to fire on the rising edge of the probe signal, requires the addition of a 1000 ohm pull down resistor. Figure 4B.24 shows a typical wiring diagram compatible with most probe designs configured to trigger on the rising edge of the probes signal.

4B-26

Page 173

Section 4B Connecting the 3-axis Servo Module

Figure 4B.24 Typical Wiring of a Touch Probe Configured for Rising Edge Trigger +5 V dc

Servo Module 470 ohm

Probe Contact

1000 ohm

1 2 3 4 5 6 7 CN9M 8

26LS32

5V common

1000 ohm pull down resistor (customer supplied)

Wiring a Probe for Falling Edge Configuration Figure 4B.25 shows a typical wiring diagram compatible with most probe designs configured to trigger on the falling edge of the probe signal. Figure 4B.25 Typical Wiring of a Touch Probe Configured for Falling Edge Trigger +5 V dc

Servo Module 470 ohm 1000 ohm

26LS32

5V common

1 2 3 4 5 6 7 CN9M 8

Probe Contact

4B-27

Page 174

Section 4B Connecting the 3-axis Servo Module

Wiring a Probe to Multiple Servo Modules Systems with more than one servo module should have their touch probe connections tied together in parallel. This allows the position to be latched on all servo modules at the same time with the same input. Only one power connection needs to be made (with pull up or down resistor). The other probe connections should be made in parallel on all servo cards. Figure 4B.26 shows a typical wiring diagram for multiple servo cards. Figure 4B.26 Multiple Servo Card Touch Probe Wiring ( Falling Edge Trigger)

+5 V dc

To Additional Servo Modules

CN9M

CN9M

470 ohm

470 ohm

26LS32 1000 ohm

1 2 3 4 5 6 5V common

Servo Module 1

4B.5 Adaptive Depth Probing

4B-28

+5 V dc

Probe Contact

Electrically tie Terminal 3 to 3 and Terminal 2 to 2 of all servo modules in the same 9/Series enclosure that use the same touch probe.

26LS32

1 2 3 4 5 6

1000 ohm

5V common

Servo Module 2

The adaptive depth probe feature is not available on the three axis digital servo card.

Page 175

Section 4B Connecting the 3-axis Servo Module

4B.6 How the Analog Servo Module Works

There are two typical analog servo drive configurations for the control. The typical mill configuration has three axes, each having a servo motor and feedback device, and an open loop spindle motor. The typical lathe configuration has two axes, each having a servo motor and feedback device, and an open loop spindle motor with position feedback. The analog servo module functions as a high speed servo processor. It is installed in the component enclosure. The analog servo amplifier amplifies the signal from the analog servo module in order to deliver the power necessary to drive the servo motors. Position and velocity data are read from a feedback device that is mounted on the slide, ballscrew, or servo motor. This feedback device generates differential signals that are then fed to the analog servo module. If the spindle motor incorporates an encoder it will supply spindle position feedback to the analog servo module.

4B-29

Page 176

Section 4B Connecting the 3-axis Servo Module

Most analog servo drive amplifiers require some form of velocity feedback from the servo motor. This feedback is usually generated by a tachometer or resolver attached to the motor shaft. Refer to your servo drive amplifier literature for details. Figure 4B.27 and Figure 4B.28 show typical analog servo drive configurations for a mill and a lathe. For specific details on configuring axes, axis positioning loops, and axis port selection, refer to the 9/Series CNC 9/230, 9/260, and 9/290 AMP Reference Manual, publication 8520-6.4. Figure 4B.27 Typical Analog Servo Drive Configuration for a Mill Feedback device

Cabinet or enclosure 9/260 or 9/290

Spindle drive

Spindle motor

Analog Servo Module (configured for three axes and one open loop spindle)

(Axis 3) Term Panel

(Axis 2) Term Panel

Velocity feedback

(Axis 1) Term Panel

Feedback device Position feedback Encoder Power

Drive Signal (Axis 1) Drive Signal (Axis 3)

Drive Signal (Axis 2) Servo Amplifier (Axis 2)

Servo Amplifier (Axis 1)

Velocity Feedback Servomotor (Axis 1)

Velocity Feedback

Velocity Feedback Servomotor (Axis 2)

Servomotor (Axis 3)

Servo Amplifier (Axis 3) 11297-I

4B-30

Page 177

Section 4B Connecting the 3-axis Servo Module

Figure 4B.28 Typical Analog Servo Drive Configuration for a Lathe Feedback Devices

Cabinet or enclosure Spindle drive

9/260 or 9/290

Spindle motor

Analog Servo Module (configured for two axes and one open loop spindle with feedback) Drive Signal (Spindle)

Velocity feedback Position feedback Encoder Power

(Axis 3) Term Panel

(Axis 2) Term Panel

Feedback devices

(Axis 1) Term Panel

Position feedback Encoder Power Velocity Feedback

Drive Signal (Axis 1) Drive Signal (Axis 2)

Servo Amplifier (Axis 1)

Velocity Feedback

Servomotor (Axis 1)

Servomotor (Axis 2)

Servo Amplifier (Axis 2) 11298-I

For additional information on each of the major components refer to the section that covers that component. Important: In order to use the solid tapping feature that is available on the 9/260 and 9/290 CNC, you must use the the Allen-Bradley 8510 AC spindle drive system.

4B-31

Page 178

Section 4B Connecting the 3-axis Servo Module

4B.6.1 Analog Servo Module

The Analog Servo Module is mounted in the component enclosure. It functions as a high-speed servo processor. The control sends positioning and velocity data to the servo module, which processes the data to generate the necessary analog drive signals. These signals are sent to the analog servo amplifiers, which power the servo motors of the control. Each analog servo module may control up to three closed loop axes and one open loop axis (typically used for a spindle). Figure 4B.29 Analog Servo Module

RUN\FLTL FBFLT1 FBFLT2 FBFLT3

FBFLT3 FBFLT2 FBFLT1 RUN\FLT

BAT/TP

TB1 CN1

ANALOG OUT

P2 TB2

P3

J2

AXIS

J1

J3

11299-I

The servo module receives position data from the axis feedback devices. It combines this position feedback data with the interpolated commands from the control to generate the command signals that it outputs to the servo amplifiers. The functions of the analog servo module are designed to make the servomotors run with optimum performance. The maximum feedrates are be limited by the mechanical abilities of the machine. System gain and the maximum allowable following error also limit the feedrates. These limits are entered as AMP parameters. Refer to the 9/Series CNC 9/230, 9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more information.

4B-32

Page 179

Section 4B Connecting the 3-axis Servo Module

4B.6.2 Analog Servo Module Connectors and Pin Assignments

Table 4B.H lists the connectors that are used to integrate the analog servo module with other modules of the control. Table 4B.H Typical Analog Servo Module Connection Connector On Servo Module

Connected To Module Connector

Cable Number

Remark

CN1

Motherboard

P4, P5, or P6

C12

J1 (D shell)

Term. Panel

AXIS

C35

AXIS

J2 (D shell)

Term. Panel

AXIS

C35

AXIS

J3 (D shell)

Term. Panel

AXIS

C35

AXIS

BAT/T.P. (TB1)

Touch Probe

--

C41

ANALOG OUT (TB2)

--

--

C42

(P2)

Not Used

N/A

N/A

(P3)

Main Power Supply (Encoder Power)

1

Wire and plug from main power supply

Important: When 1 servo module is used, it must be connected to P4 of the motherboard. When 2 servo modules are used, the first servo module must be connected to P4 and the second to connector P6. When three modules are used (9/290 only), connect the first to P4, connect the second to P6, and connect the third to P5. 1

Analog drives attached to TB2 that incorporate an encoder to supply position feedback to the servo module must be interfaced with one of the regular AXIS ”D shell”connections (J1, J2, or J3). The ANALOG OUT (TB2) has no feedback capabilities.

J1, J2, and J3 D-Shell AXIS Connectors The analog servo module sends drive signals to the servo amplifier through connectors labeled J1, J2, and J3. Figure 4B.30 shows an end view of connector J1, J2, and J3 and lists the pin assignments of these connectors.

4B-33

Page 180

Section 4B Connecting the 3-axis Servo Module

Figure 4B.30 Connectors J1, J2, and J3 - 26 Pin Female, D-Shell Connector and Pin Assignments

Pin No. 9

26

.

19 11300-I

4B-34

Signal

Description

1

Signal Destination

1

Not Used

2

Not Used

3

CHA_HI

Feedback device Channel A

Servo Module

4

CHB_HI

Feedback device Channel B

Servo Module

5

CHZ_HI

Feedback device Channel Z

Servo Module

6

+5V_ENC

+5V Encoder Power Supply

Feedback Device

7

+5V_ENC

+5V Encoder Power Supply

Feedback Device

8

SEN

Switched +5V Encoder Power Supply (not used)

Feedback Device

9

DRIVE

±10V analog drive command

Servo Amplifier

10

Not Used

11

Not Used

12

CHA_LO

Feedback device Channel A

Servo Module

13

CHB_LO

Feedback device Channel B

Servo Module

14

CHZ_LO

Feedback device Channel Z

Servo Module

15

+15V_ENC

+15V Encoder Power Supply

Feedback Device

16

GND

Encoder Power Return

Feedback Device

17

SEN. RET

Encoder Power Return

Feedback Device

18

DRIVE.RET

±10V analog drive command return

Servo Amplifier

19

Not Used

20

Not Used

21

SHLD_CHA

Shield for phase A connect at module only

22

SHLD_CHB

Shield for phase B connect at module only

23

SHLD_CHZ

Shield for phase Z connect at module only

24

SHLD_+5V

Shield for +5V connect at module only

25

SHLD_SEN

Shield for switched +5V connect at module only

26

SHLD_DRV

Shield for drive command connect at module only