Page 181

Section 4B Connecting the 3-axis Servo Module

ANALOG OUT (TB2) Auxiliary Output Connector. An auxiliary analog output is provided through the connector labeled ANALOG OUT (TB2). This connector is typically used to command an analog spindle drive system with no position feedback. TB2 is not capable of receiving encoder feedback information. Figure 4B.31 shows the location of ANALOG OUT connector and lists terminal assignments of this connector. Important: Note that TB2 should only be used for drive applications that do not require a feedback device. If a feedback is required, the output signal to the drive and its corresponding encoder feedback should be wired through one of the axis connectors J1, J2, or J3. A drive application with feedback would typically not use the connector labeled ANALOG OUT (TB2). However, if necessary, TB2 may be used with encoder feedback configured in AMP to be returned to one of the axis connectors J1, J2, or J3. Figure 4B.31 Terminal Block ANALOG OUT, 3 Plug-type Terminal Block Connections.

FBFLT3 FBFLT2 FBFLT1 RUN\FLT

3

ANALOG OUT

ANALOG OUT

BAT/TP

RUN\FLTL FBFLT1 FBFLT2 FBFLT3

2

Terminal No.

Signal

Description

Signal Destination

1

Analog Out +

±10V Analog with no

(typically spindle drive)

2

Analog Out -

Signal Return

(typically spindle drive)

3

Shield shield connect at module only feedback

AXIS

1

11301-I

4B-35

Page 182

Section 4B Connecting the 3-axis Servo Module

BAT/TP (TB1) Touch Probe Connector. The analog servo module receives touch probe feedback through the connector labeled BAT/TP (TB1). Figure 4B.32 shows the location of the BAT/TP connector and lists the terminal assignments. Figure 4B.32 Connector BAT/TP, 6 Plug-type Terminal Block Connections.

6 5

ANALOG OUT

BAT/TP

FBFLT3 FBFLT2 FBFLT1 RUN\FLT

BAT/TP

RUN\FLTL FBFLT1 FBFLT2 FBFLT3

Terminal No.

Signal

1

Not Used

2

Not Used

3

+5V

Probe Power

Touch Probe

4

PRB_FIRE

Probe Fired Signal 1

Servo Module

5

PE

Touch Probe Common

Touch Probe

6

Shield

Probe Shield connect at module only

4 3 2

AXIS

1

1

Description

Signal Destination

The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as defined by the AMP parameter PROBE TRANSITION. Refer to the 9/Series

CNC 9/230, 9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more information.

11302-I

Important: The touch probe connector supports only +5V probing device applications.

P3 5V dc Encoder Power Connector The analog servo module receives +5V dc power directly from the main power supply through connector P3. This +5V dc power is used only for powering the encoder. If the EXT Power connection on the encoder termination panel is used or if the 15V dc encoder power is used the connection to P3 is not needed. Figure 4B.33 shows an end view of connector P3 and lists the pin assignments. For details on this connection refer to the section on the main power supply connections on page 4D-4.

4B-36

Page 183

Section 4B Connecting the 3-axis Servo Module

Figure 4B.33 Connector P3, 2 pin male, Molex 5566-02A

1

2

4B.6.3 Analog Servo Module Specifications

Pin No.

Signal

1

Not Used

2

+ 5V dc

11282-I

Description

Signal Destination

Encoder Power

Main Power Supply

Table 4B.I lists the analog servo module output specifications. This table is provided as an aid to determining the compatibility of different analog servo amplifiers and spindle drives. Table 12.A contains a list of compatible analog servos. Input specifications are discussed in sections covering the individual input devices. Refer to Table 4C.E for encoder feedback input specifications. Table 4B.I Analog Servo Module Analog Output Specifications Item

Specification

Output Voltage Range

±10V

Analog Output Driver

Single Ended

Output Offset Voltage

500mV Max.

Resolution

1.22mV

Sampling Frequency

500 Hz

Output Current

5mA Max.

Load Range

2K ohms to infinity

Conversion Time

8.25ms

Differential Non-Linearity

±1 LSB Max.

Gain Error

±1 LSB Max.

Load Capacitance

0.01mF Max.

1 2

Remark

Drive return connected to common.

(13 bits) 1

2

This resolution is obtained through software. It is equal to a 13-bit numeric value with an additional sign bit (14 bits total). Monotonic over the entire temperature range. LSB means least significant bit.

4B-37

Page 184

Section 4B Connecting the 3-axis Servo Module

4B.6.4 Connecting Axes to Analog Servo Module

Axes are connected to the D-shell connectors marked J1, J2, and J3. Axes must be connected consecutively with no empty connections between axes. For example, an axis may not be connected to the connector J3 unless both J1 and J2 are used. If two servo modules are used, all three axes on the first servo module must be connected before an axis may be configured on the second servo module. If a spindle with feedback is configured the spindle must be connected to the first available D-Shell connector after the last connector used by a linear or rotary axis. ATTENTION: Do not insert the plug-type ANALOG OUT terminal block (TB2) into an encoder termination panel DRIVE terminal block or vice versa. Although these plugs will fit together, pin assignments are different. Switching these connections without rewiring the plug-type terminal block may cause damage to equipment.

For example to configure a four axis system with a spindle with feedback two servo modules are necessary. The first three axes must be connected to the three D shell connectors on the first servo board. The fourth axis must connect to the second servo board connector labeled J1. The spindle with feedback must then be connected to the D shell labeled J2 on the second servo board. For this specific application the spindle may not be attached to the first servo board or J3 of the second servo board.

4B.6.5 Analog Servo Module LED Indicators

4B-38

The analog servo module is equipped with a set of four LEDs located on the front of the servo module. Table 4B.J lists the meaning of these LEDs. Table 4B.J Analog Servo Module LED Indicators LED

Color

RUN/FLT

Green

Indicates the servo processor OK when lit. Watch dog has failed or power fault has occurred when LED is not lit.

FBFLT 1

Red

Indicates the servo module is not receiving feedback, or is receiving interrupted or irregular feedback from the feedback device on J1 when lit.

FBFLT 2

Red

Indicates the servo module is not receiving feedback, or is receiving interrupted or irregular feedback from the feedback device on J2 when lit.

FBFLT3

Red

Indicates the servo module is not receiving feedback, or is receiving interrupted or irregular feedback from the feedback device on J3 when lit.

Description

Page 185

Section 4B Connecting the 3-axis Servo Module

4B.6.6 Analog Servo Module Test Points

Test points are small metallic pins on the analog servo module circuit board. Hardware troubleshooting and testing for proper wiring can begin by testing for proper voltage or signals at these pins. Test points are labeled with the letters TP followed by a number. Figure 4B.34 shows the location of each test point. Table 4B.K lists the test data of each test point. Figure 4B.34 Analog Servo Module Test Point Locations

TB1 CN1 TP6 TP8 TP10 TP11 TP12

TP5 TP7 TP9

P2

TB2

P3

TP13 TP14 TP15

J1

TP16 TP17 TP18

J2

TP19 TP20 TP21

J3

11304-I

4B-39

Page 186

Section 4B Connecting the 3-axis Servo Module

Table 4B.K Analog Servo Module Test Point Values Test Point TP5

+10V dc Reference

TP7

Analog Ground

TP9

-10V dc Reference

Test Point

Module Power Reference Voltages

TP6

+5 V dc

TP8

Digital Ground

TP10

+15V dc

TP11

Analog Ground

TP12

-15V dc

Test Point

4B-40

Analog DAC reference Voltages

Encoder Feedback Signals

TP13

Z Channel connector J1

TP14

B Channel connector J1

TP15

A Channel connector J1

TP16

Z Channel connector J2

TP17

B Channel connector J2

TP18

A Channel connector J2

TP19

Z Channel connector J3

TP20

B Channel connector J3

TP21

A Channel connector J3

Page 187

Section 4B Connecting the 3-axis Servo Module

4B.7 Encoder Termination Panel

The encoder termination panels are options with the analog system that provide an easy and convenient means for you to connect and troubleshoot your servo system. We strongly recommend the use of termination panels when installing an analog system. Termination panels feature: D-shell connectors for cables from the motion controller (A-B cable number 8520-TPC) Plug-type connectors for wiring to user devices DIN Rail Mountable All user connections with the exception of the ANALOG OUT (TB2) and BAT/TP (TB1) connections are routed through the termination panels. User side voltages of +5V dc and +15V dc for encoder power (chosen by wiring to the appropriate connector pin) are available on-board. External power supplies for the encoders may also be routed through the termination panel (refer to the feedback section). Figure 4B.35 shows an encoder termination panel. Figure 4B.35 Encoder Termination Panel DRIVE

AXIS

DRIVE RET SHLD ENCODER CH A. HI CH A. LO AB SHLD CH B. HI CH B. LO Z SHLD CH Z. HI CH Z. LO ENC POWER

EXT POWER

+5V RET +15V EX PWR OUT SHLD EX PWR IN EX RET IN FDBK IO FDBK IO RET SHLD

91670401 1771HTE ENCODER TERMINATION PANEL

11305-I

4B-41

Page 188

Section 4B Connecting the 3-axis Servo Module

4B.8 Compatible Feedback Devices

This section discusses encoder feedback devices that are compatible for both analog and digital servo systems. The servo module supplies these devices with either +5V or +15V power. Feedback devices on all the CNCs must return a 5V compatible output signal to the control (1326 motor mounted resolvers have their signals converted by the system module to be compliant with this requirement). For analog systems this feedback device can be used to provide: velocity feedback (used only if your system does not provide tachometer velocity feedback to the drive) In this case, the analog servo amplifier must be configured to run in “torque mode” with no tachometer. Tachless servo configurations work best if an encoder type feedback device is used and mechanically coupled directly to the servomotor shaft. position feedback (can be the same device as used to close the velocity loop if the velocity loop is closed by the CNC, or an additional feedback device, as discussed in this section, can be used for the position loop) spindle feedback For digital systems this feedback device can be used to provide: position feedback (digital systems require the motor mounted feedback device, provided on our standard digital servo motors, be used for velocity loop feedback. This motor mounted feedback device can also be used to close the position loop or an additional feedback device, as discussed in this section, can be used for the position loop.) You can not replace or bypass the motor mounted feedback device. The motor mounted feedback device must be used for velocity feedback and to attain proper motor commutation on digital servo systems. spindle feedback Only the 8520 digital drive system supports absolute feedback.

4B-42

Page 189

Section 4B Connecting the 3-axis Servo Module

The 3 axis 9/260 and 9/290 servo cards support: Feedback Device

Additional hardware

Allen-Bradley 845H series differential encoders

--

Sony Magnascale model GF-45E

Board-type detector model MD10-FR

Heidenhain Model 704

External interpolation and digitizing model EXE602 D/5-F

Futaba Pulscale model FM45NY

PCB interface Module model CZ0180 with cable PCB020EA

Other feedback devices can be compatible if they comply with the specifications listed in Table 4B.L. Refer to the 9/Series CNC AMP Reference Manual, publication 8520-6.4, for more information. This manual is written under the assumption that your system is using the Allen-Bradley 845H series differential encoder. If you are using some other feedback device such as a linear scale, an application note is available through Allen-Bradley CNC Commercial Engineering Department at area code (216) 646-3963. The following table lists feedback specifications for a differential encoder however, this information can be interpreted to select an appropriate linear scale.

4B-43

Page 190

Section 4B Connecting the 3-axis Servo Module

Table 4B.L Encoder Specifications Specification

Item Maximum Encoder Channel Frequency (ECF)

Use the following equation to determine the maximum channel frequency Clock Maximum Encoder Channel Frequency = Where:

360 90-Eq x 1.15

Clock - is the Control’s Feedback Clock Frequency: 5 x 106 - for 9/230, 9/440, and three axis servo cards. 2.3 x 107 - for 9/260 or 9/290 systems using a four axis servo card EQ = Quadrature Error in Degrees 1.15 = Our minimum recommended safety factor As long as the actual feedback channel frequency does not exceed the maximum channel frequency calculated above, the servo module should process the feedback data without a quadrature fault. Maximum Axis Speed

Use the following equation to determine the maximum axis speed. Note that this equation does not take into consideration any mechanical deficiencies in the encoder or motor. It is only concerned with the 9/Series capability of receiving feedback. Refer to the manufactures specs for encoder and motor hardware RPM limitations. (ECF x 60) ---------------(E) (N) (P)

=

Maximum Axis Speed

Where: Max Axis Speed = Maximum Axis Speed based on encoder feedback (inches or millimeters per minute) ECF = Maximum encoder channel frequency the control may receive in units of cycles/sec. E = the number of encoder lines between markers for your encoder N = the ratio of encoder turns to ballscrew turns P = the ballscrew pitch (turns per inch or turns per millimeter. For rotary axes, substitute the appropriate gear ration for N and P in the equation above to solve for a max RPM in revolutions per minute. If the maximum axis speed resulting from this equation is less than you would like, you may need to sacrifice some axis resolution by selecting an encoder with fewer lines between markers.

4B-44

Input Signal

Encoder feedback must be differential format with 5V compatible output signals, single-ended open-collector outputs are not supported, i.e., channels A, B, and Z must have source and sink current capability, 8830 line driver outputs or equivalent.

Current Drawn from Encoder by Servo Module

7mA maximum; 44mA peak

Marker Channel

Narrow marker (gated) or Wide marker (ungated) type markers are supported

Encoder Cable Length

Refer to 9/Series Integration and Maintenance Manual for details on cabling