Page 191

Section 4B Connecting the 3-axis Servo Module

4B.8.1 Wiring an Incremental Feedback Device

Figure 4B.36 shows an incremental feedback device equivalent circuit for feedback channel A. Figure 4B.36 Incremental Feedback Device Equivalent Circuit

+5V Cable 8500-TPC

768W 0.01u f

+

A

Differential Line Driver Ch A HI Ch A LO

-

221W

A

Customer Encoder

768W +5V Analog Servo Module

Termination Panel

11306-I

Wiring Position Feedback Feedback devices used with the control must be configurable such that the marker Z is true at the same time that channels A & B are true. If you are using an Allen-Bradley 845H encoder this requirement will already be met if you wire them as shown in the cable diagrams on page 7A-53. If you are using an encoder type feedback device other than the Allen-Bradley 845H encoder, then use the following wiring procedure: 1.

Obtain the encoder output timing diagram from the vendor’s data sheets. A typical one is provided in Figure 4B.37 as an example.

4B-45

Page 192

Section 4B Connecting the 3-axis Servo Module

Figure 4B.37 Example of a Typical Vendor Encoder Timing Diagram NO TE: Be l o w w ir in g is a n e x a m p le o n ly o f a t y p ic a l v e n d o r s e n c o d e r . S e e y o u r e n c o d e r , v e n d or s t im in g d ia g r a m .

1 cycle 90°

S TEP 3 C h a n n e l A is h ig h a t le a s t p a r t o f m a r k e r in te r v a l. C o n n e c t t o “C H A . H I ” o f te r m in a tio n p a n e l.

Hi

Channel A

Lo

B

Optional

Z

STEP 1 H ig h m a r k e r in te r v a l. C o n n e c t t o “C H Z . H I” o f te r m in a t io n p a n e l. STE P 2 B is h ig h f o r a t le a s t p a r t o f m a r k e r in t e r v a l. C o n n e c t t o “C H B . H I ” o f t e r m in a t io n p a n e l.

A’

B’ Z’

CCW rotation viewing shaft W ir e C H B , C H A , a n d C H Z t o C H B L O , C H A L O a n d C H Z L O , r e s p e c tiv e ly , o n t h e te r m in a t io n p a n e l.

11307-I

2.

On the timing diagram, look at the marker Z and its complement, marker Z’. Whichever one is low for most of the encoder revolution and pulses high should be wired to “CH Z.HI” of the encoder termination panel. Wire the remaining marker to “CH Z.LO” of the encoder termination panel.

3.

Look at channel B and its complement, channel B’. Whichever one is high for at least part of the marker interval should be wired to “CH B.HI” of the encoder termination panel. It is possible that both channels meet this requirement depending on the encoder manufacturer, in which case, use either one. Wire the remaining channel to “CH B.LO” of the encoder termination panel.

4.

Look at channel A and its complement channel A’and repeat as in step 3 using “CH A.HI” and “CH A.LO” of the encoder termination panel . ATTENTION: You can find a marker even if your encoder is not phased properly. An improperly phased encoder will still home successfully.

4B-46

Page 193

Section 4B Connecting the 3-axis Servo Module

If the previous procedure is not performed correctly, inconsistent homing of the axis may occur. If your encoder phasing cannot provide an interval at which the marker and both channels are simultaneously true, the encoder should be considered incompatible with the control. Important: Since positive and negative axis directions can be assigned without regard to encoder rotation directions, it is possible for the feedback direction to be “backwards”. This is easily corrected before attempting to command axis motion through the AMP parameter Sign of Position Feedback. Refer to the 9/Series CNC 9/230,9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more information.

Wiring Power for your Feedback Device (Analog Systems Only) The control supports feedback devices with 5v compatible output signals. The voltage that these feedback devices require may vary. The analog servo module is equipped to supply 5V dc or 15V dc power to feedback devices. These voltages may be accessed directly from the encoder termination panel . For more information refer to page 7A-8. Important: Be aware that if the 5V dc encoder power is to be used the connector P3 on the servo module must be directly connected to the power supply. Refer to page 4D-4 for details on this power supply connection. If your feedback device requires an external power supply, you can incorporate it through the EXT. POWER connector on the termination panel. Power outputs through the ENC POWER connector terminal labeled EX PWR OUT. The next figure shows the termination panel connection for EXT. POWER. Figure 4B.38 Wiring Optional Customer Supplied Power Supply for Feedback Devices

EXT. POWER External Power

EXT PWR IN

Ground

EXT RET IN

Shield

Term Panel

Optional Customer Supplied Power Supply

11308-I

4B-47

Page 194

Section 4B Connecting the 3-axis Servo Module

4B.9 Wiring a Touch Probe to the Analog Servo Module

Connect a touch probe to the connector labeled BAT/TP on the servo module (TB1). Connector terminal identification is provided in Figure 4B.39. Touch probe cable information can be found on page 7A-38. The time delay between the servo module receiving the touch probe trigger and latching the current axis position is negligible. However, you should be aware of any external delays that may introduce position “staleness” in the probing operation, especially at high probing speeds. It is a good idea to establish an offset for the distance between the actual location, as sensed by the probe at a very low speed, and the location sensed by the probe at the intended probing speed. The offset can then be added or subtracted to any future values obtained through probing. This helps make sure that if there are any external delays in the trigger signal, the position staleness shows up as a constant position offset error and is removed from the measurement (assuming the external delay is repeatable). The motion controller touch probe interface is intended for use with units that offer 5V dc compatible solid state relay outputs (see figure 9.12). Other configurations can be supported as long as the user operates within the published electrical specifications. The touch probe circuitry resident on the servo module only responds to the trigger probe edge changes. Polarity transition (high to low or low to high) is selectable through the AMP parameter Probe Transition. Specify the probe transition in AMP as rising edge or falling edge. Once the active edge occurs, position data is captured by the module, and additional occurrences of the trigger signal have no effect until the probe is reenabled under program control. Refer to the 9/Series CNC 9/230,9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more information. ATTENTION: It is preferred, from a safety standpoint, that the touch probe relay be closed at rest and open when the touch probe stylus deflects. Then, if a wire breaks or shorts to ground, it will appear to the system as a probe fired and the probing cycle in process will stop commanding motion towards the part. The user should make every effort towards the fail-safe operation of the touch probe. Not all vendor’s touch probe control units conform to this safety consideration.

4B-48

Page 195

Section 4B Connecting the 3-axis Servo Module

Figure 4B.39 shows the internal servo module circuitry that interfaces to the touch probe connector. It is shown here to assist you in determining whether your touch probe hardware is compatible. Figure 4B.39 Internal Circuitry Supporting the Touch Probe

Servo Module

5V common

1000 ohm 26LS32 470 ohm

6 5 4 3 2 1

Shield GND probe +5V Power

BAT/TP TB1

NC

+5 V dc 11309-I

The following table indicates probing threshold voltages. Maximum Input Threshold (critical if the control has been configured to fire on the falling edge of the probe signal) indicates the voltage that the probe signal must fall below to be considered as “fired”. Minimum Input Threshold (critical if the control has been configured to fire on the rising edge of the probe signal) indicates the voltage that the probe signal must rise above to be considered as fired Probe Thresholds

Voltage at Threshold

Minimum Input Threshold (probe circuit)

3.06 (min)

Maximum Input Threshold (probe circuit)

2.18V dc (max)

To avoid misfires use the threshold values from the above table to determine the necessary signal voltage for steady state operation (probe not fired). For probes configured to fire on the falling edge the steady state voltage must remain above 3.06 volts. For probes configured to fire on the rising edge the steady state voltage must remain below 2.18 volts.

Wiring a Probe for Rising Edge Configurations Typical wiring of a simple contactor type touch probe configured to fire on the rising edge of the probe signal, requires the addition of a 1000 ohm pull down resistor. Figure 4B.40 shows a typical wiring diagram compatible with most probe designs configured to trigger on the rising edge of the probe’s signal.

4B-49

Page 196

Section 4B Connecting the 3-axis Servo Module

Figure 4B.40 Typical Wiring of a Touch Probe Configured for Rising Edge Trigger

Servo Module

Probe Contact

5V common

6 5 4 3 2 1

1000 ohm 26LS32 470 ohm +5 V dc

BAT/TP TB1 11309-I

Wiring a Probe for Falling Edge Configuration Figure 4B.41 shows a typical wiring diagram compatible with most probe designs configured to trigger on the falling edge of the probe signal. Figure 4B.41 Typical Wiring of a Touch Probe Configured for Falling Edge Trigger 1000 ohm pull down resistor (customer supplied)

Servo Module 5V common

1000 ohm 26LS32 470 ohm +5 V dc

6 5 4 3 2 1

Probe Contact

BAT/TP TB1

Wiring a Probe to Multiple Servo Cards Systems with more than one servo module should have their touch probe connections tied together in parallel. This allows the position to be latched on all servo modules at the same time with the same input. Only one power connection needs to be made (with pull up or down resistor). The other probe connections should be made in parallel on all servo cards.

4B-50

Page 197

Section 4B Connecting the 3-axis Servo Module

Figure 4C.22 shows a typical wiring diagram for multiple servo cards. Figure 4B.42 Multiple Servo Card Touch Probe Wiring ( Falling Edge Trigger) To All Additional Servo Modules

Servo Module 1

Servo Module 2

5V common

1000 ohm 26LS32 470 ohm +5 V dc

4B.10 Adaptive Depth Probing

BAT/TP TB1

5V common

6 5 4 3 2 1

Probe Contact

Electrically tie Terminal 5 to 5 and Terminal 4 to 4 of all servo modules in the same 9/Series enclosure that use the same touch probe.

6 5 4 3 2 1

BAT/TP TB1

1000 ohm 26LS32 470 ohm +5 V dc

Use the Adaptive Depth probe feature to enable an adaptive depth probe that monitors tool depth relative to the actual part surface. This feature allows: a more flexible part mounting system (small changes to part size or part mounting do not require reprogramming of the machine or station) greater accuracy with a less accurate machine drive system (tool position is relative to the part surface rather than the machine home) a retroactive change in axis positioning resolution (feedback for axis positioning switches between the normal axis encoder and the adaptive depth probe once the probe is triggered). Important: Since the adaptive depth probing feature requires one feedback port to pass probe position data to the control and another feedback port for normal axis positioning feedback, the adaptive depth feature is not compatible with the single axis 9/230 processor which only has one feedback port. The adaptive depth probe is wired like any A quad B rotary encoder. It is connected to one of the controls feedback ports. Table 4C.E lists specifications for an encoder. These same specifications apply to your adaptive depth probe. If you are using the adaptive depth probe to close the position loop (selected in AMP) the maximum axis speed calculations from Table 4C.E also applies. Refer to your AMP reference manual for details on other configuration required to operate using an adaptive depth probe.

4B-51

Page 198

Section 4B Connecting the 3-axis Servo Module

In AMP the adaptive depth probe is assigned an axis name. Using the axis monitor page for that axis (see page 15A-35) you can view the current following error on the adaptive depth probe and the adaptive depth probe position relative to zero. The probe is zeroed automatically at power up or through PAL.

END OF SECTION

4B-52

Page 199

Section

4C

Connecting the 4-axis Servo Module

4C.0 Section Overview

4C.1 How the Digital Servo Card Works

This section covers the integration of the 4-axis analog/1394 and digital servo module components. A section is devoted to each of the following drive components: For Information:

See Page:

How the Digital Servo Card Works

4C-1

Digital Servo Module (8520-ENC4)

4C-4

How the Analog/1394 Servo Card Works

4C-5

Analog/1394 Servo Module (8520-ENC4)

4C-8

Connecting Axes to the Servo Module

4C-9

Servo Module Connectors and Pin Assignments

4C-9

8520-ENC4 Servo Module Specifications

4C-15

8520-SM4 Servo Module Specifications

4C-16

Servo Module Battery Replacement

4C-17

Servo Module LED Indicators

4C-19

Servo Module Test Points

4C-19

Encoder Termination Panel

4C-20

Feedback Devices

4C-21

Wiring a Touch Probe to the Servo Module

4C-27

There are two typical digital servo drive configurations for the control. The typical mill configuration has 3-axes, each having a servo motor and feed back device, and a 1-axis analog open loop spindle motor. The typical lathe configuration has 2-axes, each having a servo motor and feedback device, and a 1-axis analog open loop spindle motor with position feedback. The servo module functions as a high speed servo processor. It is installed in the component enclosure. The digital servo amplifier translates low-level PWM signals from the servo module to the power levels necessary to drive the servo motors. Current feedback data is read from the current sensors in the digital servo amplifier and returned to the servo module. This data is processed by the servo module to maintain velocity and position control, according to module, AMP, and part program constraints. 4C-1

Page 200

Section 4C Connecting the 4-axis Servo Module

Important: In order to use the solid tapping feature that is available on the 9/260 and 9/290 CNC, you must use the Allen-Bradley 8510 AC spindle drive system. Position and velocity data are read from a feedback device that is mounted on the servo motor. This feedback device generates differential signals that are then fed to the servo module. If the spindle motor uses an encoder, it will supply spindle position feedback to the digital servo module. Figure 4C.1 and Figure 4C.2 show typical servo drive configurations for a mill and a lathe. Refer to your AMP reference manual for specific details on configuring axes, axis positioning loops, and axis port selection. Figure 4C.1 Typical Digital Servo Drive Configuration for a Mill Feedback device

Cabinet or enclosure 9/260 or 9/290

Digital Servo Module (configured for three axes and one open loop spindle)

Servomotor (Axis 1) Servo drive signal (Axis 1) Current feedback (Axis 1)

Servo Amplifier

Servo drive signal (Axis 2) Current feedback (Axis 2)

(3 Axis amplifier)

Servo drive signal (Axis 3) Current feedback (Axis 3)

Servomotor (Axis 2)

Servomotor (Axis 3) Feedback device

Analog signal

Position feedback

4C-2

Spindle drive

Spindle motor

Velocity feedback

11274-I