Page 211

Section 4C Connecting the 4-axis Servo Module

ANALOG OUT (TB2) Auxiliary Output Connector. An auxiliary analog output is provided through the connector labeled ANALOG OUT (TB2). This connector is typically used to command an analog spindle drive system with no position feedback. TB2 is not capable of receiving encoder feedback information. Figure 4C.10 shows the location of ANALOG OUT connector and lists terminal assignments of this connector. Important: Note that TB2 should only be used for drive applications that do not require a feedback device. If a feedback is required, the output signal to the drive and its corresponding encoder feedback should be wired through one of the servo connectors. A drive application with feedback would typically not use the connector labeled ANALOG OUT (TB2). However, if necessary, TB2 may be used with encoder feedback configured in AMP to be returned to one of the servo connectors.

1 3

TOUCH PROBE ANALOG OUT

FLT

2 4

Figure 4C.10 Terminal Block ANALOG OUT, 4 Plug-type Terminal Block Connections.

4 3

Signal

Description

Signal Destination

1 not connected

2

Analog Out +

+10V Analog with no feedback

(typically spindle drive)

3

Analog Out -

Signal Return

(typically spindle drive)

4

Shield shield connect at module only

1

J4

J3

J2

J1

2

Terminal No.

4C-13

Page 212

Section 4C Connecting the 4-axis Servo Module

Touch Probe Connector - TB1 The servo module receives touch probe feedback through the connector labeled TB1. Figure 4C.11 shows the location of this connector and lists its terminal assignments. Figure 4C.11 TB1 Connector , 4 Plug-type Terminal Block Connections. Signal

Terminal No.

1 3

TOUCH PROBE ANALOG OUT

FLT

2 4

4 3

J1

2

Signal Destination

1

+5V

Probe Power

Touch Probe

2

PRB_FIRE

Probe Fired Signal 1

Servo Module

3

PE

Touch Probe Common

Touch Probe

4

Shield

Probe Shield connect at module only

J2

The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as defined by the AMP parameter PROBE TRANSITION. Refer to your AMP reference manual for more information.

Important: The touch probe connector supports only +5V probing device applications.

J3

1

1

Description

5V DC Encoder Power Connector - P3

J4

The servo module receives +5V dc power directly from the main power supply through connector P3. This +5V dc power is used only for powering the encoder. If the EXT Power connection on the encoder termination panel is used or if the 15V DC encoder power is used the connection to P3 is not needed. Figure 4C.12 shows an end view of connector P3 and lists the pin assignments. For details on this connection refer to the section on the main power supply connections on page 4D-4. Figure 4C.12 Connector P3, 2 pin male, Molex 5566-02A

2

4C-14

1

11282-I

Pin No.

Signal

1

Not Used

2

+ 5V dc

Description

Signal Destination

Encoder Power

Main Power Supply

Page 213

Section 4C Connecting the 4-axis Servo Module

4C.5.2 8520-ENC4 Servo Module Specifications

Table 4C.B lists the servo module input specifications. Table 4C.B Servo Module Input Specifications Item

Specification

Remark

Input Power Range for Encoders

+5V (+10%, -1%) +15V (±7%)

From Main Power Supply

Maximum Input Frequency of Encoder Feedback

2MHz

Maximum Cable Length Specified

Desired Voltage Range of Encoder Battery Backup

3.5V to 4.5V

______

Table 4C.C lists the servo module output specifications. Table 4C.C Servo Module Output Specifications Item

Specification

PWM Output (8520 digital only)

PWM Frequency

Approx. 2.0 KHz

PWM Signal Type

RS-422-A

Comutated Output (1394 digital only)

Comutated Signal IA and IB

Approx. 1000 Hz

DAC Output

Output Voltage Range

±10V

Resolution

2.44mV

Sampling Frequency

1000 Hz

Output Current

5mA Max.

Load Capacitance

0.01mF Max.

Remark

(±12 bits)

(±12 bits)

4C-15

Page 214

Section 4C Connecting the 4-axis Servo Module

4C.5.3 8520-SM4 Servo Module Specifications

Table 4C.D lists the servo module output specifications. This table is provided as an aid to determining the compatibility of different servo amplifiers and spindle drives. Table 12.A contains a list of compatible analog servos. Input specifications are discussed in sections covering the individual input devices. Refer to Table 4C.E for encoder feedback input specifications. Table 4C.D 8520-SM4 Servo Module Analog Output Specifications Item

4C-16

Specification

Output Voltage Range

±10V

Analog Output Driver

Single Ended

Output Offset Voltage

500mV Max.

Resolution

1.22mV

Sampling Frequency

500 Hz

Output Current

5mA Max.

Load Range

>2K ohms

Conversion Time

5ms

Differential Non-Linearity

±1 LSB Max.

Gain Error

±1 LSB Max.

Load Capacitance

0.01mF Max.

Remark

Drive return connected to common.

13 bits plus one sign bit (14 total)

Monotonic over the entire temperature range. LSB means least significant bit.

Page 215

Section 4C Connecting the 4-axis Servo Module

4C.5.4 Digital Servo Module Battery Replacement

The Digital Servo Module, 8520-ENC4, provides battery backup for the absolute encoder position register. This register retains position data during power loss. The battery backup power originates from the batteries plugged into the servo board at connector P2. Important: Battery backup is required for absolute encoders only. Incremental encoders do not require battery backup. Even if battery backup fails, or the encoder cable is temporarily disconnected, the encoder will still maintain position data for up to 24 hours. This also allows for battery replacement without loss of data. The battery backup is tested at power up, and at four hour intervals while system power is on. If battery voltage drops to 2.8V during the battery test, the control automatically displays the warning message “REPLACE ABSOLUTE FEEDBACK BATTERY” on the operator panel. Important: Once the “REPLACE ABSOLUTE FEEDBACK BATTERY” message is displayed, it is essential that the batteries be replaced to avoid loss of absolute position data.

The lithium battery contains heavy metals and must be collected separately from other waste.

4C-17

Page 216

Section 4C Connecting the 4-axis Servo Module

To replace the servo module battery, turn all system power OFF and disconnect the old batteries from connector P2 on the servo module. Battery replacement instructions are included with the battery replacement kit. Before installing new batteries, use a voltage meter to make sure that new battery voltage is higher than 3.5V dc. Figure 4C.13 Servo Module Battery Connector P2

TB2 TB1

P1 (CN1)

J1

J2

J3

P2 P3

4C-18

Page 217

Section 4C Connecting the 4-axis Servo Module

4C.5.5 Servo Module LED Indicators

The servo module is equipped with a set of four LEDs located on the front of the servo module. All four LEDs turn on, then off, at power up. All the LEDs remain off during normal operation. If a servo fault occurs, the light for the corresponding axis flashes. The servo fault may occur if the module is not receiving feedback, or is receiving interrupted or irregular feedback through the J1, J2, J3 or J4 connector.

4C.5.6 Servo Module Test Points

A test point is a small metallic pin on the servo module’s circuit board. There is one test point available in the servo module that you can use to ground an oscilloscope during testing or troubleshooting. You can locate this test point, TP6, with Figure 4C.14. Figure 4C.14 Servo Module Test Point Location

TB2 TB1

P1 (CN1)

J1

TP6 J2

J3

P2 P3

4C-19

Page 218

Section 4C Connecting the 4-axis Servo Module

4C.6 Encoder Termination Panel

The encoder termination panels are options with the analog system that provide an easy and convenient means for you to connect and troubleshoot your servo system. We strongly recommend the use of termination panels when installing an analog system. Termination panels feature: D-shell connectors for cables from the servo module (A-B cable number 8520-TPC) Plug-type connectors for wiring to user devices DIN Rail Mounting All user connections with the exception of the analog out and touch probe connections are routed through the termination panels. User side voltages of +5V dc and +15V dc for encoder power (chosen by wiring to the appropriate connector pin) are available on-board. External power supplies for the encoders may also be routed through the termination panel (refer to the feedback section). Figure 4C.15 shows an encoder termination panel. Figure 4C.15 Encoder Termination Panel DRIVE

AXIS

DRIVE RET SHLD ENCODER CH A. HI CH A. LO AB SHLD CH B. HI CH B. LO Z SHLD CH Z. HI CH Z. LO ENC POWER

EXT POWER

+5V RET +15V EX PWR OUT SHLD EX PWR IN EX RET IN FDBK IO FDBK IO RET SHLD

91670401 1771HTE ENCODER TERMINATION PANEL

4C-20

11305-I

Page 219

Section 4C Connecting the 4-axis Servo Module

4C.7 Compatible Feedback Devices

This section discusses encoder feedback devices that are compatible for both analog and digital servo systems. The servo module supplies these devices with either +5V or +15V power. Feedback devices on all the CNCs must return a 5V compatible output signal to the control (1326 motor mounted resolvers have their signals converted by the system module to be compliant with this requirement). For analog systems this feedback device can be used to provide: velocity feedback (used only if your system does not provide tachometer velocity feedback to the drive) In this case, the analog servo amplifier must be configured to run in “torque mode” with no tachometer. Tachless servo configurations work best if an encoder type feedback device is used and mechanically coupled directly to the servomotor shaft. position feedback (can be the same device as used to close the velocity loop if the velocity loop is closed by the CNC, or an additional feedback device, as discussed in this section, can be used for the position loop) spindle feedback For digital systems this feedback device can be used to provide: position feedback (digital systems require the motor mounted feedback device, provided on our standard digital servo motors, be used for velocity loop feedback. This motor mounted feedback device can also be used to close the position loop or an additional feedback device, as discussed in this section, can be used for the position loop.) You can not replace or bypass the motor mounted feedback device. The motor mounted feedback device must be used for velocity feedback and to attain proper motor commutation on digital servo systems. spindle feedback Only the 8520 digital drive system supports absolute feedback.

4C-21

Page 220

Section 4C Connecting the 4-axis Servo Module

The 4 axis 9/260 and 9/290 servo cards support: Feedback Device

Additional hardware

Allen-Bradley 845H series differential encoders

--

Sony Magnascale model GF-45E

Board-type detector model MD10-FR

Heidenhain Model 704

External interpolation and digitizing model EXE602 D/5-F

Futaba Pulscale model FM45NY

PCB interface Module model CZ0180 with cable PCB020EA

Other feedback devices can be compatible if they comply with the specifications listed in Table 4B.L. Refer to the 9/Series CNC AMP Reference Manual, publication 8520-6.4, for more information. This manual is written under the assumption that your system is using the Allen-Bradley 845H series differential encoder. If you are using some other feedback device such as a linear scale, an application note is available through Allen-Bradley CNC Commercial Engineering Department. Contact your local Allen--Bradley sales representative. The following table lists feedback specifications for a differential encoder however, this information can be interpreted to select an appropriate linear scale.

4C-22