Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 23 of 91

9/Series CNC Hardware Integration and Maintenance Manual, pages 221 to 230

Pages 221 to 230 of 898

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 8500-1746I

Page 221

Section 4C Connecting the 4-axis Servo Module

Table 4C.E Encoder Specifications Specification

Item Maximum Encoder Channel Frequency (ECF)

Use the following equation to determine the maximum channel frequency Clock Maximum Encoder Channel Frequency = Where:

360 90-Eq x 1.15

Clock - is the Control’s Feedback Clock Frequency: 5 x 106 - for 9/230, 9/440, and three axis servo cards. 2.3 x 107 - for 9/260 or 9/290 systems using a four axis servo card EQ = Quadrature Error in Degrees 1.15 = Our minimum recommended safety factor As long as the actual feedback channel frequency does not exceed the maximum channel frequency calculated above, the servo module should process the feedback data without a quadrature fault. Maximum Axis Speed

Use the following equation to determine the maximum axis speed. Note that this equation does not take into consideration any mechanical deficiencies in the encoder or motor. It is only concerned with the 9/Series capability of receiving feedback. Refer to the manufactures specs for encoder and motor hardware RPM limitations. (ECF x 60) ---------------(4E) (N) (P)

=

Maximum Axis Speed

Where: Max Axis Speed = Maximum Axis Speed based on encoder feedback (inches or millimeters per minute) ECF = Maximum encoder channel frequency the control may receive in units of cycles/sec. E = the number of encoder lines between markers for your encoder N = the ratio of encoder turns to ballscrew turns P = the ballscrew pitch (turns per inch or turns per millimeter. For rotary axes, substitute the appropriate gear ration for N and P in the equation above to solve for a max RPM in revolutions per minute. If the maximum axis speed resulting from this equation is less than you would like, you may need to sacrifice some axis resolution by selecting an encoder with fewer lines between markers. Input Signal

Encoder feedback must be differential format with 5V compatible output signals, single-ended open-collector outputs are not supported, i.e., channels A, B, and Z must have source and sink current capability, 8830 line driver outputs or equivalent.

Current Drawn from Encoder by Servo Module

7mA maximum; 44mA peak

Marker Channel

Narrow marker (gated) or Wide marker (ungated) type markers are supported

Encoder Cable Length

Refer to 9/Series Integration and Maintenance Manual for details on cabling

4C-23

Page 222

Section 4C Connecting the 4-axis Servo Module

4C.7.1 Wiring an Incremental Feedback Device

Figure 4C.16 shows an incremental feedback device equivalent circuit for feedback channel A. Figure 4C.16 Incremental Feedback Device Equivalent Circuit

+5V

68pf

0V 316 W To Encoder Interface

215 W

Cable 8500-TPC A

Zenor Protection

Differential Line Driver Ch A HI Ch A LO

A Optical Isolation

Customer Encoder

Encoder Return

+5V 0V

Termination Panel Servo Module

Wiring Position Feedback Feedback devices used with the control must be configurable such that the marker Z is true at the same time that channels A & B are true. If you are using an Allen-Bradley 845H encoder this requirement will already be met if you wire them as shown in the cable diagrams on page 7A-28. If you are using an encoder type feedback device other than the Allen-Bradley 845H encoder, then use the following examples to determine the correct wiring:

4C-24

Page 223

Section 4C Connecting the 4-axis Servo Module

Figure 4C.17 Examples of a Correct and Incorrect Encoder Wiring Incorrect Encoder Wiring Correct Encoder Wiring results in a servo fault results in expected motion A+ A-

A+ A-

A+ A-

A+ A-

B+ B-

B+ B-

B+ B-

B+ B-

Z+ Z-

Z+ Z-

Z+ Z-

Z+ Z-

Encoder

Control

Encoder

Incorrect Encoder Wiring results in unpredictable motion

Control

Incorrect Encoder Wiring results in expected motion

A+ A-

A+ A-

A+ A-

A+ A-

B+ B-

B+ B-

B+ B-

B+ B-

Z+ Z-

Z+ Z-

Z+ Z-

Z+ Z-

Encoder

Control

Encoder

Control

Important: Since positive and negative axis directions can be assigned without regard to encoder rotation directions, it is possible for the feedback direction to be “backwards”. This is easily corrected before attempting to command axis motion through the AMP parameter Sign of Position Feedback. Refer to your AMP reference manual for more information.

4C-25

Page 224

Section 4C Connecting the 4-axis Servo Module

Wiring Power for your Feedback Device (Analog Systems Only) The control supports feedback devices with 5V compatible output signals. The voltage that these feedback devices require may vary. The servo module is equipped to supply 5V DC or 15V DC power to feedback devices. These voltages may be accessed directly from the encoder termination panel. However, for the 1394 this power connection is only necessary if you are using optional feedback devices. The 1394 drive supplies feedback power to the 1326 motor resolvers. Important: Be aware that if the 5V DC encoder power is to be used the connector P3 on the servo module must be directly connected to the power supply. Refer to page 4D-4 for details on this power supply connection. If your feedback device requires an external power supply, you can incorporate it through the EXT. POWER connector on the termination panel. Power outputs through the ENC POWER connector terminal labeled EX PWR OUT. The next figure shows the termination panel connection for EXT. POWER. Figure 4C.18 Wiring Optional Customer Supplied Power Supply for Feedback Devices

EXT. POWER External Power

EXT PWR IN

Ground

EXT RET IN

Shield

4C-26

Term Panel

Optional Customer Supplied Power Supply

11308-I

Page 225

Section 4C Connecting the 4-axis Servo Module

4C.8 Wiring a Touch Probe to the Servo Module

Connect a touch probe to the connector labeled BAT/TP on the servo module (TB1). Connector terminal identification is provided in Figure 4C.18. Touch probe cable information can be found on page 7A-38. The time delay between the servo module receiving the touch probe trigger and latching the current axis position is negligible. However, you should be aware of any external delays that may introduce position “staleness” in the probing operation, especially at high probing speeds. It is a good idea to establish an offset for the distance between the actual location, as sensed by the probe at a very low speed, and the location sensed by the probe at the intended probing speed. The offset can then be added or subtracted to any future values obtained through probing. This helps make sure that if there are any external delays in the trigger signal, the position staleness shows up as a constant position offset error and is removed from the measurement (assuming the external delay is repeatable). The motion controller touch probe interface is intended for use with units that offer 5V dc compatible solid state relay outputs (see Figure 4C.19). Other configurations can be supported as long as the user operates within the published electrical specifications. The touch probe circuitry resident on the servo module only responds to the trigger probe edge changes. Polarity transition (high to low or low to high) is selectable through the AMP parameter Probe Transition. Specify the probe transition in AMP as rising edge or falling edge. Once the active edge occurs, position data is captured by the module, and additional occurrences of the trigger signal have no effect until the probe is reenabled under program control. Refer to the 9/Series CNC 9/230,9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more information. ATTENTION: It is preferred, from a safety standpoint, that the touch probe relay be closed at rest and open when the touch probe stylus deflects. Then, if a wire breaks or shorts to ground, it will appear to the system as a probe fired and the probing cycle in process will stop commanding motion towards the part. The user should make every effort towards the fail-safe operation of the touch probe. Not all vendor’s touch probe control units conform to this safety consideration.

4C-27

Page 226

Section 4C Connecting the 4-axis Servo Module

Figure 4C.19 shows the internal servo module circuitry that interfaces to the touch probe connector. It is shown here to assist you in determining whether your touch probe hardware is compatible. Figure 4C.19 Internal Circuitry Supporting the Touch Probe

Servo Module 5V common to encoder interface 1000 ohm

4 3 2 1

Shield GND probe +5V Power

470 ohm +5 V dc Encoder Power 11309-I

The following table indicates probing threshold voltages. Maximum Input Threshold (critical if the control has been configured to fire on the falling edge of the probe signal) indicates the voltage that the probe signal must fall below to be considered as “fired”. Minimum Input Threshold (critical if the control has been configured to fire on the rising edge of the probe signal) indicates the voltage that the probe signal must rise above to be considered as fired Probe Thresholds

4C-28

Voltage at Threshold

Minimum Input Threshold (probe circuit)

3.06 (min)

Maximum Input Threshold (probe circuit)

2.18V dc (max)

Page 227

Section 4C Connecting the 4-axis Servo Module

To avoid misfires use the threshold values from the above table to determine the necessary signal voltage for steady state operation (probe not fired). For probes configured to fire on the falling edge the steady state voltage must remain above 3.06 volts. For probes configured to fire on the rising edge the steady state voltage must remain below 2.18 volts.

Wiring a Probe for Rising Edge Configurations Typical wiring of a simple contactor type touch probe configured to fire on the rising edge of the probe signal, requires the addition of a 1000 ohm pull down resistor. Figure 4C.20 shows a typical wiring diagram compatible with most probe designs configured to trigger on the rising edge of the probes signal. Figure 4C.20 Typical Wiring of a Touch Probe Configured for Rising Edge Trigger

Servo Module to encoder interface

5V common

1000 ohm

1000 ohm pull down resistor (customer supplied)

4 3 2 1 Probe Contact

470 ohm +5 V dc

4C-29

Page 228

Section 4C Connecting the 4-axis Servo Module

Wiring a Probe for Falling Edge Configuration Figure 4C.21 shows a typical wiring diagram compatible with most probe designs configured to trigger on the falling edge of the probe signal. Figure 4C.21 Typical Wiring of a Touch Probe Configured for Falling Edge Trigger

Servo Module

Probe Contact

5V common to encoder interface 1000 ohm

4 3 2 1

470 ohm +5 V dc 11309-I

Wiring a Probe to Multiple Servo Cards Systems with more than one servo module should have their touch probe connections tied together in parallel. This allows the position to be latched on all servo modules at the same time with the same input. Only one power connection needs to be made (with pull up or down resistor). The other probe connections should be made in parallel on all servo cards. Figure 4C.22 shows a typical wiring diagram for multiple servo cards. Figure 4C.22 Multiple Servo Card Touch Probe Wiring ( Falling Edge Trigger) To Additional Servo Modules

Servo Module 1 to encoder interface 1000 ohm

470 ohm +5 V dc

4C-30

4 3 2 1

Servo Module 2

5V common

5V common Probe Contact

Electrically tie Terminal 5 to 5 and Terminal 4 to 4 of all servo modules in the same 9/Series enclosure that use the same touch probe.

4 3 2 1 to encoder interface 1000 ohm

470 ohm +5 V dc

Page 229

Section 4C Connecting the 4-axis Servo Module

4C.9 Adaptive Depth Probing

Use the Adaptive Depth probe feature to enable an adaptive depth probe that monitors tool depth relative to the actual part surface. This feature allows: a more flexible part mounting system (small changes to part size or part mounting do not require reprogramming of the machine or station) greater accuracy with a less accurate machine drive system (tool position is relative to the part surface rather than the machine home) a retroactive change in axis positioning resolution (feedback for axis positioning switches between the normal axis encoder and the adaptive depth probe once the probe is triggered). The adaptive depth probe is wired like any A quad B rotary encoder. It is connected to one of the controls feedback ports. Refer to page 7A-1 for details on cabling requirements for a feedback device. 4C-23 lists specifications for an encoder. These same specifications apply to your adaptive depth probe. If you are using the adaptive depth probe to close the position loop (selected in AMP) the maximum axis speed calculations from 4C-23 also applies. Refer to your AMP reference manual for details on other configuration required to operate using an adaptive depth probe. In AMP the adaptive depth probe is assigned an axis name. Using the axis monitor page for that axis (see page 15A-35) you can view the current following error on the adaptive depth probe and the adaptive depth probe position relative to zero. The probe is zeroed automatically at power up or through PAL.

END OF SECTION

4C-31

Page 230

Section 4C Connecting the 4-axis Servo Module

4C-32