Page 281

Section 5A 9/440 Resolver- based CNC/Drive System

ATTENTION: The E--Stop status relay (or your customer--supplied E--Stop control relay) should not be the only method through which axis brakes are directly released (see the illustration below). Brakes should be released by a combination of the PAL logic when it determines that the 9/440 system is in full control of the servo motors and the control’s E--Stop status contact and an external hardware E--Stop contact. Refer to the description of the PAL flags $AXME and $STME for details about testing drive status.

Brake

PAL- controlled

9/440 E- Stop Status Relay

Power Supply

5A-35

Page 282

Section 5A 9/440 Resolver- based CNC/Drive System

5A.6 Connecting Axis Modules

The Axis Module provides terminating points for the motor power, thermal sensor and brake. Axis module wiring is identical for all module ratings. Refer to Figure 5A.19 and the paragraphs that follow for detailed information. Figure 5A.19 Axis Module Connections

U1

V1

W1 PE2 PE1 PE3

TB1 and TB2 (Located on Bottom of Module)

Motor Wiring Allen-Bradley 1326-CPB1xxx cables must be used for connection to the motor. The motor wiring size is determined by the continuous and overload current requirements (RMS Duty Cycle), NEC and local codes. In general, motors operated with the 1394 should not require wire sizes larger than those accepted by the motor terminal blocks. In addition, the motor leads must be twisted throughout their entire length to minimize radiated electrical noise. The maximum motor wire sizes that the 1394 Axis Module terminal block will accept are dependent upon axis module selection (see your 1394 users manual).

5A-36

Page 283

Section 5A 9/440 Resolver- based CNC/Drive System

See page 5A-12 for details on resolver cables (1326-CCUxxx). 1326 servo motors have integral thermal protection. This contact must be connected in the E--Stop string for motor overload protection. Connections are performed through the front panel terminal block as shown in Figure 5A.19. Refer to the information below and the Interconnect Drawings on page 5A-41 for further information. Table 5A.B Motor Power Terminations Terminal

Description

Wire/Pin Number

U1

Motor Power A

1

V1

Motor Power B

2

W1

Motor Power C

3

PE1

Axis Ground

Ground Bar

PE2

Motor Ground

8

PE3

Overall Shield

7

Thermal and Brake Leads The motor thermal sensor and brake leads (if used) are connected to the Axis Module at TB1 & TB2. See Figure 5A.19 for location and Table 5A.C for terminations.

5A-37

Page 284

Section 5A 9/440 Resolver- based CNC/Drive System

Table 5A.C Thermal Sensor and Brake Terminations Terminal

Description

Wire/Pin Number

TB1-1, 2

Thermal Sensor Input from Motor Cable string axis modules

TB1-3, 4

Brake 24V DC Input from Motor Cable user brake

TB2-1, 2

Brake 24V DC To Brake Control

5, 9

TB2-3, 4

Thermal Sensor Output to Fault System

4, 6

TB1 All Axis modules

Axis Module

6

(applying 24V DC releases brake)

TB2 Axis module 1

Brake

TB2 Axis module 2

User Brake Control Thermal String (connect to E- Stop String)

4 5

9

Motor

Thermostat

TB2 Axis module 3

User Brake Control

TB2 Axis module 4

User Brake Control

User Brake Control

ATTENTION: Brake control should not be directly released by the E--Stop status relay (or your customer supplied E--Stop control relay). Brakes should only be released by the PAL logic when it has determined that the 9/440 resolver--based control is in full control of the servo motors and the control is out of E--Stop. See the description of the PAL flag $PFLT.15 for detail on how to test drive status.

5A-38

Page 285

Section 5A 9/440 Resolver- based CNC/Drive System

5A.7 9/440 Resolver- based LEDs

9/440 Resolver--based CNC/Drive has 4 LEDs on the system module and one LED on each axis module in the system. The LEDs operate as follows. System Module LEDs The system module has 4 LEDs. They are: LED

Indicates

XILINX

Under normal operation this LED is on. If it turns off while the system module is under power it indicates a XILINX hardware fault. Contact your local Allen- Bradley Service.

WATCHDOG

Under normal operation this LED is on. If it turns off while the system module is under power it indicates the watchdog has timed out and a processor failure has occurred. Contact your local Allen-Bradley Service.

R- I/O

Only available on systems with remote I/O. This LED illuminates when the remote I/O link is communicating. See page 5A-26.

STATUS

This is identical to the Watchdog LED but is visible through the system modules front cover.

9/440 Resolver--based System Module

Wiring Board

XILINX

Press Cover Release to Open Open Cover

WATCHDOG

Status LED

R-I/O LED (visible from under system module in front of serial port B)

5A-39

Page 286

Section 5A 9/440 Resolver- based CNC/Drive System

Check your 9/Series CRT for any drive faults that may have occurred and are displayed as an error. Axis Module LEDs The Axis module has a Status LED visible thru the front cover. It is: LED

Indicates

STATUS

Steady Green Flashing Green Flashing Red/Green Flashing Red Steady Red bus up, axis enabled bus up, axis not enabled ready, bus not up fault present hardware malfunction

For more details on how to diagnose and troubleshoot your axis module refer to the 1394 Digital AC Multi-Axis Motion Control System Users Manual (publication 1394-5.0)

5A.8 General Wiring Overview

5A-40

The following figure shows a typical interconnect diagram for a 9/440 Resolver--based CNC to 1326 motors. Note this figure illustrates only one servo motor with optional feedback encoder. The 9/440 Resolver--based CNC can support up to four servo’s and two spindle drives.

Page 287

Section 5A 9/440 Resolver- based CNC/Drive System

Figure 5A.20 Wiring Overview For 9/440 Resolver- based CNC Processor Board

Fiber Optic I/O Ring

TB1

Video Port

J8

Serial Port B

J7

Serial Port A

J6

1 2 3 4 5 6 7

MTB E--Stop Connections External Customer E--Stop String E--Stop Status String

M1

1394 Axis Module

Analog Out 1

Analog Out 2

Remote I/O

1 2 3 4 5 6

TB2 Wiring Board

1 2 3

RIO1 TB4

Thermostat and Brake Feedthru

TB1 TB3

U1 V1 W1 PE1 PE2 PE3 4 3 2 1 TB5

SHLD

1 2 3 4

1

Touch Probe

2

3

8

T1 T2 T3

RIO2

User Supplied 24V AC or 24V DC (non-polarized), 15A

M1 M1 M1 Three-phase input 360-480V AC

To Cabinate Ground Bar

DC+ COL INT W1 W2 U V W PE

7

GND

6

4

5

9

B2 B1 K2 K1

4 3 2 1 To next axis and User Brake Control Input

Brake

9/440 Resolver- based System Module 9/440 Resolver-based Power Supply

TB2

Feedback Board Resolver Inputs J1, J2, J3, or J4

Servo Motor 1 6 2 3 8 7 9 4 5 10

Encoder Inputs J9, J10, or J11

2 8 1 7 3 9 5 11 12 6

Thermostat

Ground Bar

A B D E

Resolver

H G 1326 Motor

A H I B C J D F

AB 845H Encoder

5A-41

Page 288

Section 5A 9/440 Resolver- based CNC/Drive System

System Grounding Figure 5A.21 illustrates the recommended 9/440 Resolver--based grounding scheme. All grounds terminate on a single point. Note there are two separate ground wires going to the system module. One ground connects to PE of the system module power terminal block, the other connects to the ground stud found just beneath the wiring board on the mounting bracket for the 9/440 Resolver--based CNC assembly.

9/440 Resolver--based System Module

Power Terminal Block 9/440 Resolver- based CNC Assembly PE Stud

Open cover

DC+

INT

COL

W1

W2

U

V

W

PE

PE Power Terminal Block Ground

5A-42

Page 289

Section 5A 9/440 Resolver- based CNC/Drive System

Figure 5A.21 System Grounding Diagram for 9/440 Resolver- based control Resolvers

Machine Tool

Earth GND (typically AWG 8)*

Analog I/O

Chassis GND (typically AWG 10)*

Encoder input output

Chassis GND (typically AWG 12)* Signal GND

Servo motor

Digital I/O (dc)

GND through mounting

Servo motor

Spindle motor

Potential Earth (PE) (typically AWG 8)* * Refer to local standards and codes for wire sizing.

Operator Cabinet

Drives Cabinet

PE

Operator Panel (see below)

9/440 Resolver- based CNC/Drive

Chassis GRND Stud

System Module

PE MTB Panel

Ground Stud on 9/440 Resolver- based CNC assembly

Chassis GRND Stud

Axis Modules (PE1)

PE on power supply

MTB Panel I/O module Spindle Drive HPG

Component Enclosure High Density I/O

Single point GND

Transformer

Digital I/O (ac) PE

RS-422 or RS-232 Terminal PE Chassis GRND Stud

Color Operator Panel Color CRT

Keyboard interface

Operator Panel power supply

PE Chassis GRND Stud

Monochrome Operator Panel Monochrome CRT

Keyboard interface

Operator Panel power supply

PE

Portable Operator Panel Interface Assembly Operator Panel Interface Module

Keyboard interface

Chassis GRND Stud

Operator Panel power supply

5A-43

Page 290

Section 5A 9/440 Resolver- based CNC/Drive System

5A-44