Page 281
Section 5A 9/440 Resolver- based CNC/Drive System
ATTENTION: The E--Stop status relay (or your customer--supplied E--Stop control relay) should not be the only method through which axis brakes are directly released (see the illustration below). Brakes should be released by a combination of the PAL logic when it determines that the 9/440 system is in full control of the servo motors and the control’s E--Stop status contact and an external hardware E--Stop contact. Refer to the description of the PAL flags $AXME and $STME for details about testing drive status.
Brake
PAL- controlled
9/440 E- Stop Status Relay
Power Supply
5A-35
Page 282
Section 5A 9/440 Resolver- based CNC/Drive System
5A.6 Connecting Axis Modules
The Axis Module provides terminating points for the motor power, thermal sensor and brake. Axis module wiring is identical for all module ratings. Refer to Figure 5A.19 and the paragraphs that follow for detailed information. Figure 5A.19 Axis Module Connections
U1
V1
W1 PE2 PE1 PE3
TB1 and TB2 (Located on Bottom of Module)
Motor Wiring Allen-Bradley 1326-CPB1xxx cables must be used for connection to the motor. The motor wiring size is determined by the continuous and overload current requirements (RMS Duty Cycle), NEC and local codes. In general, motors operated with the 1394 should not require wire sizes larger than those accepted by the motor terminal blocks. In addition, the motor leads must be twisted throughout their entire length to minimize radiated electrical noise. The maximum motor wire sizes that the 1394 Axis Module terminal block will accept are dependent upon axis module selection (see your 1394 users manual).
5A-36
Page 283
Section 5A 9/440 Resolver- based CNC/Drive System
See page 5A-12 for details on resolver cables (1326-CCUxxx). 1326 servo motors have integral thermal protection. This contact must be connected in the E--Stop string for motor overload protection. Connections are performed through the front panel terminal block as shown in Figure 5A.19. Refer to the information below and the Interconnect Drawings on page 5A-41 for further information. Table 5A.B Motor Power Terminations Terminal
Description
Wire/Pin Number
U1
Motor Power A
1
V1
Motor Power B
2
W1
Motor Power C
3
PE1
Axis Ground
Ground Bar
PE2
Motor Ground
8
PE3
Overall Shield
7
Thermal and Brake Leads The motor thermal sensor and brake leads (if used) are connected to the Axis Module at TB1 & TB2. See Figure 5A.19 for location and Table 5A.C for terminations.
5A-37
Page 284
Section 5A 9/440 Resolver- based CNC/Drive System
Table 5A.C Thermal Sensor and Brake Terminations Terminal
Description
Wire/Pin Number
TB1-1, 2
Thermal Sensor Input from Motor Cable string axis modules
TB1-3, 4
Brake 24V DC Input from Motor Cable user brake
TB2-1, 2
Brake 24V DC To Brake Control
5, 9
TB2-3, 4
Thermal Sensor Output to Fault System
4, 6
TB1 All Axis modules
Axis Module
6
(applying 24V DC releases brake)
TB2 Axis module 1
Brake
TB2 Axis module 2
User Brake Control Thermal String (connect to E- Stop String)
4 5
9
Motor
Thermostat
TB2 Axis module 3
User Brake Control
TB2 Axis module 4
User Brake Control
User Brake Control
ATTENTION: Brake control should not be directly released by the E--Stop status relay (or your customer supplied E--Stop control relay). Brakes should only be released by the PAL logic when it has determined that the 9/440 resolver--based control is in full control of the servo motors and the control is out of E--Stop. See the description of the PAL flag $PFLT.15 for detail on how to test drive status.
5A-38
Page 285
Section 5A 9/440 Resolver- based CNC/Drive System
5A.7 9/440 Resolver- based LEDs
9/440 Resolver--based CNC/Drive has 4 LEDs on the system module and one LED on each axis module in the system. The LEDs operate as follows. System Module LEDs The system module has 4 LEDs. They are: LED
Indicates
XILINX
Under normal operation this LED is on. If it turns off while the system module is under power it indicates a XILINX hardware fault. Contact your local Allen- Bradley Service.
WATCHDOG
Under normal operation this LED is on. If it turns off while the system module is under power it indicates the watchdog has timed out and a processor failure has occurred. Contact your local Allen-Bradley Service.
R- I/O
Only available on systems with remote I/O. This LED illuminates when the remote I/O link is communicating. See page 5A-26.
STATUS
This is identical to the Watchdog LED but is visible through the system modules front cover.
9/440 Resolver--based System Module
Wiring Board
XILINX
Press Cover Release to Open Open Cover
WATCHDOG
Status LED
R-I/O LED (visible from under system module in front of serial port B)
5A-39
Page 286
Section 5A 9/440 Resolver- based CNC/Drive System
Check your 9/Series CRT for any drive faults that may have occurred and are displayed as an error. Axis Module LEDs The Axis module has a Status LED visible thru the front cover. It is: LED
Indicates
STATUS
Steady Green Flashing Green Flashing Red/Green Flashing Red Steady Red bus up, axis enabled bus up, axis not enabled ready, bus not up fault present hardware malfunction
For more details on how to diagnose and troubleshoot your axis module refer to the 1394 Digital AC Multi-Axis Motion Control System Users Manual (publication 1394-5.0)
5A.8 General Wiring Overview
5A-40
The following figure shows a typical interconnect diagram for a 9/440 Resolver--based CNC to 1326 motors. Note this figure illustrates only one servo motor with optional feedback encoder. The 9/440 Resolver--based CNC can support up to four servo’s and two spindle drives.
Page 287
Section 5A 9/440 Resolver- based CNC/Drive System
Figure 5A.20 Wiring Overview For 9/440 Resolver- based CNC Processor Board
Fiber Optic I/O Ring
TB1
Video Port
J8
Serial Port B
J7
Serial Port A
J6
1 2 3 4 5 6 7
MTB E--Stop Connections External Customer E--Stop String E--Stop Status String
M1
1394 Axis Module
Analog Out 1
Analog Out 2
Remote I/O
1 2 3 4 5 6
TB2 Wiring Board
1 2 3
RIO1 TB4
Thermostat and Brake Feedthru
TB1 TB3
U1 V1 W1 PE1 PE2 PE3 4 3 2 1 TB5
SHLD
1 2 3 4
1
Touch Probe
2
3
8
T1 T2 T3
RIO2
User Supplied 24V AC or 24V DC (non-polarized), 15A
M1 M1 M1 Three-phase input 360-480V AC
To Cabinate Ground Bar
DC+ COL INT W1 W2 U V W PE
7
GND
6
4
5
9
B2 B1 K2 K1
4 3 2 1 To next axis and User Brake Control Input
Brake
9/440 Resolver- based System Module 9/440 Resolver-based Power Supply
TB2
Feedback Board Resolver Inputs J1, J2, J3, or J4
Servo Motor 1 6 2 3 8 7 9 4 5 10
Encoder Inputs J9, J10, or J11
2 8 1 7 3 9 5 11 12 6
Thermostat
Ground Bar
A B D E
Resolver
H G 1326 Motor
A H I B C J D F
AB 845H Encoder
5A-41
Page 288
Section 5A 9/440 Resolver- based CNC/Drive System
System Grounding Figure 5A.21 illustrates the recommended 9/440 Resolver--based grounding scheme. All grounds terminate on a single point. Note there are two separate ground wires going to the system module. One ground connects to PE of the system module power terminal block, the other connects to the ground stud found just beneath the wiring board on the mounting bracket for the 9/440 Resolver--based CNC assembly.
9/440 Resolver--based System Module
Power Terminal Block 9/440 Resolver- based CNC Assembly PE Stud
Open cover
DC+
INT
COL
W1
W2
U
V
W
PE
PE Power Terminal Block Ground
5A-42
Page 289
Section 5A 9/440 Resolver- based CNC/Drive System
Figure 5A.21 System Grounding Diagram for 9/440 Resolver- based control Resolvers
Machine Tool
Earth GND (typically AWG 8)*
Analog I/O
Chassis GND (typically AWG 10)*
Encoder input output
Chassis GND (typically AWG 12)* Signal GND
Servo motor
Digital I/O (dc)
GND through mounting
Servo motor
Spindle motor
Potential Earth (PE) (typically AWG 8)* * Refer to local standards and codes for wire sizing.
Operator Cabinet
Drives Cabinet
PE
Operator Panel (see below)
9/440 Resolver- based CNC/Drive
Chassis GRND Stud
System Module
PE MTB Panel
Ground Stud on 9/440 Resolver- based CNC assembly
Chassis GRND Stud
Axis Modules (PE1)
PE on power supply
MTB Panel I/O module Spindle Drive HPG
Component Enclosure High Density I/O
Single point GND
Transformer
Digital I/O (ac) PE
RS-422 or RS-232 Terminal PE Chassis GRND Stud
Color Operator Panel Color CRT
Keyboard interface
Operator Panel power supply
PE Chassis GRND Stud
Monochrome Operator Panel Monochrome CRT
Keyboard interface
Operator Panel power supply
PE
Portable Operator Panel Interface Assembly Operator Panel Interface Module
Keyboard interface
Chassis GRND Stud
Operator Panel power supply
5A-43
Page 290
Section 5A 9/440 Resolver- based CNC/Drive System
5A-44