The text of a manual · part 32 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 311 to 320
Pages 311 to 320 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 311
Section 5B 9/440HR CNC/Drive System
Wiring Board Battery Backup Connection
J5
P1 +
F1 Fuse
--
[ALL FUSES] [3A/125V]
XILINX
Drive Interface
TB5
WATCHDOG
Touch Probe Connection
SHLD GND TPIN +5V
F2 Spare Fuse
TB2
TB3
SHLD ANLGOUT2 RET SHLD ANLGOUT1 RET
RIO2 SHLD RIO1
TB4
Remote I/O Plug
J14
Analog Out 1 (spindle 1)
Analog Out 2 (spindle 2)
5B.4.1 Wiring a Touch Probe to the 9/440
The 9/440HR system module touch probe connection is made to connector TB5 on the wiring board. Table 5B.A shows the location of this connector and lists its terminal assignments.
Wiring Board
Table 5B.A TB5 Connector , 4 Plug-type Terminal Block Connections
P1 +
J5 J14
--
Terminal
XILINX
WATCHDOG
TB5
TB2 TB3 SHLD
GND
TPIN
+5V
TB4
1
Description
Signal Destination
+5V
Probe Power
Touch Probe
TP IN
Probe Fired Signal1
Servo Position Latch
GND
Touch Probe Common
Touch Probe
SHLD
Probe Shield connect at module only
The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as defined by the AMP parameter PROBE TRANSITION. Refer to your AMP reference manual for more information.
Important: The touch probe connector supports only +5V probing device applications.
5B-21
Page 312
Section 5B 9/440HR CNC/Drive System
The time delay between the 9/440HR receiving the touch probe trigger and latching the current axis position is negligible. However, you should be aware of any external delays that may introduce position “staleness” in the probing operation, especially at high probing speeds. It is a good idea to establish an offset for the distance between the actual location, as sensed by the probe at a very low speed, and the location sensed by the probe at the intended probing speed. The offset can then be added or subtracted to any future values obtained through probing. This helps make sure that if there are any external delays in the trigger signal, the position staleness shows up as a constant position offset error and is removed from the measurement (assuming the external delay is repeatable). The touch probe interface is intended for use with units that offer 5V dc compatible solid state relay outputs (see Figure 5B.10). Other configurations can be supported as long as the user operates within the published electrical specifications. The touch probe circuitry resident on the 9/440HR only responds to the trigger probe edge changes. Polarity transition (high to low or low to high) is selectable through the AMP parameter Probe Transition. Specify the probe transition in AMP as rising edge or falling edge. Once the active edge occurs, position data is captured by the module, and additional occurrences of the trigger signal have no effect until the probe is re-enabled under program control. Refer to the 9/Series CNC AMP Reference Manual, publication 8520-6.4, for more information. ATTENTION: From a safety standpoint, it is preferred that the touch probe relay be closed at rest and open when the touch probe stylus deflects. Then, if a wire breaks or shorts to ground, it will appear to the system as a probe fired and the probing cycle in process will stop commanding motion towards the part. The user should make every effort towards the fail-safe operation of the touch probe. Not all vendor’s touch probe control units conform to this safety consideration.
5B-22
Page 313
Section 5B 9/440HR CNC/Drive System
Figure 5B.10 shows the internal servo module circuitry that interfaces to the touch probe connector. It is shown here to assist you in determining whether your touch probe hardware is compatible. Figure 5B.10 Internal Circuitry Supporting the Touch Probe
9/440HR Wiring Board 5V common to encoder interface 1000 ohm
4 3 2 1
Shield GND TP IN +5V Power
470 ohm +5 V dc Encoder Power 11309-I
The following table indicates probing threshold voltages. Maximum Input Threshold (critical if the control has been configured to fire on the falling edge of the probe signal) indicates the voltage that the probe signal must fall below to be considered as “fired”. Minimum Input Threshold (critical if the control has been configured to fire on the rising edge of the probe signal) indicates the voltage that the probe signal must rise above to be considered as fired Probe Thresholds
Voltage at Threshold
Minimum Input Threshold (probe circuit)
3.06 (min)
Maximum Input Threshold (probe circuit)
2.18V dc (max)
5B-23
Page 314
Section 5B 9/440HR CNC/Drive System
To avoid misfires use the threshold values from the above table to determine the necessary signal voltage for steady state operation (probe not fired). For probes configured to fire on the falling edge the steady state voltage must remain above 3.06 volts. For probes configured to fire on the rising edge the steady state voltage must remain below 2.18 volts.
Wiring a Probe for Rising Edge Configurations Typical wiring of a simple contactor type touch probe configured to fire on the rising edge of the probe signal, requires the addition of a 1000 ohm pull down resistor. Figure 5B.11 shows a typical wiring diagram compatible with most probe designs configured to trigger on the rising edge of the probes signal. Figure 5B.11 Typical Wiring of a Touch Probe Configured for Rising Edge Trigger
9/440HR Wiring Board to encoder interface
1000 ohm
5V common 1000 ohm pull down resistor (customer supplied)
4 3 2 1 Probe Contact
470 ohm +5 V dc
5B-24
Page 315
Section 5B 9/440HR CNC/Drive System
Wiring a Probe for Falling Edge Configuration Figure 5B.12 shows a typical wiring diagram compatible with most probe designs configured to trigger on the falling edge of the probe signal. Figure 5B.12 Typical Wiring of a Touch Probe Configured for Falling Edge Trigger
9/440HR Wiring Board
Probe Contact
5V common to encoder interface 1000 ohm
4 3 2 1
470 ohm +5 V dc 11309-I
5B-25
Page 316
Section 5B 9/440HR CNC/Drive System
5B.4.2 9/440HR Remote I/O Connection
The remote I/O circuitry and connector are integral parts of the wiring board in the 9/440HR system module. Figure 5B.13 shows the remote I/O connector mounted on the 9/440HR wiring board. Wire connections for the remote I/O communications are made through the TB4 NODE ADAPT connector. Connect the wires for remote I/O as shown in the following figure. Refer to your 1771 I/O documentation for details on making remote I/O connections. Figure 5B.13 Remote I/O Connector in System Module
9/440HR System Module
Remote I/O Plug RIO2
RIO1
SHLD
Blue Shield Clear
TB4
Open Cover
9/440HR Remote I/O LED Assuming you have: made all necessary remote I/O communication connections on your 1771 I/O network configured your remote I/O port for the remote I/O network in AMP written PAL to set $RMON true during the first PAL foreground execution, and to handle input and output words ($RMI1 -- $RMI8 inputs to PAL and $RMO1 -- $RMO8 outputs from PAL.)
5B-26
Page 317
Section 5B 9/440HR CNC/Drive System
CNC Processor Board
Front of System Module
Serial Port A
R--I/O LED
5B.4.3 9/440HR Analog Out (TB2 and TB3)
You are ready to start receiving and transmitting remote I/O information. An LED is provided on the 9/440HR CNC processor board and is visible from the bottom of the system module. As remote I/O responds to commands, you should see this LED pattern: LED
Status
Description
Green R- I/O LED
ON
Active Link to PLC. This is the normal state when the RIO link is active.
FLASHING
The remote I/O link is active but the PLC is currently in program mode.
OFF
Remote I/O link is offline. The port is not being used, not configured in AMP correctly, not turned on with $RMON, or not attached to a 1771 device.
Video
Two auxiliary analog outputs are provided through the connectors labeled TB2 and TB3 of the 9/440HR Wiring Board. These connectors are typically used to command external analog spindle drive systems but can also be configured in AMP to control additional analog servo systems. Figure 5B.14 shows the location of ANALOG OUT connector and lists terminal assignments of this connector. Important: If positioning feedback is required for the spindle or analog servo system, its corresponding encoder feedback should be wired through one of the encoder feedback connectors and indicated as such in AMP. Figure 5B.14 Terminal Block TB2 and TB3, Plug-type Terminal Block Connections. P1 +
Wiring Board
J5 J14
-WATCHDOG
TB2
TB3
SHLD ANLGOUT2 RET SHLD ANLGOUT1 RET
XILINX
TB2 TB3
TB4
Analog Out 1 (spindle 1)
Analog Out 2 (spindle 2)
5B-27
Page 318
Section 5B 9/440HR CNC/Drive System
Connector
5B.4.4 Battery Backup
Description
Signal Destination
Analog Out
±10V Analog with no feedback
(typically spindle drive)
RET
Signal Return
(typically spindle drive)
SHLD shield connect at wiring board only
The memory for such items as part programs, tool offset/compensation data, and work coordinate offset data is stored on the processor board. In the case of a power failure, there is a super capacitor on the processor board that backs up this data for up to 5 days (at 40°C) on systems without extended program storage. This super capacitor recharges within 1 hour of power turn on if completely discharged. If you want to extend this backup time install the lithium battery pack that supports the data for: 9/440HR Memory Option:
Time (at 40°C Discharge):
standard
3 years with extended program storage
1 year
This battery pack is connected to the lithium battery connector (P1) on the wiring board as shown in Figure 5B.15. Batteries and the battery cable are included with the battery replacement kit. Figure 5B.15 Lithium Battery 9/440HR System Module Connect the battery pack to P1 on the wiring board. Wiring Board
Mount the battery pack to the inside of the module cover.
P1 +
-
Press Cover Release to Open
The lithium battery contains heavy metals and must be collected separately from other waste.
5B-28
Page 319
Section 5B 9/440HR CNC/Drive System
5B.5 Power Terminal Block Connection
All external power connections to the 9/440HR CNC/Drive are wired through the system modules power strip, located behind the front cover in the lower right corner. Input power is wired to this strip in two different voltages: 24 V Logic Power -- this is 24 V AC or 24 V DC. The logic power is used to operate the processors in the system module, axis module logic boards, and power the encoders. Drive Power -- this is 324-528 V AC, three phase, 50/60 Hz. The drive power is used to supply the drive portion of the 9/440HR the voltages necessary to power the axis modules and the servo motors. To this Power Strip Connector
Connect:
W1
+24 V Logic Power
W2
24 V Logic Power common
U, V, W
380/460V AC, three- phase power (not phase sensitive)
PE
System Ground Bar
DC+, INT, COL
Shunt resistor connection. When the jumper exists between INT and COL the internal 200 W shunt is used. When using the optionally purchased 1000 W shunt the jumper is removed and the new shunt is installed between DC+ and COL.
All connectors on the power strip support a maximum of AWG 12 gauge solid wire.
9/440HR System Module
Wiring Board
Power Terminal Block
E-Stop connections (TB1)
DC+
INT
COL
W1
W2
U
V
W
PE
5B-29
Page 320
Section 5B 9/440HR CNC/Drive System
5B.5.1 On/Off Control and 24V Logic Power
24 Volt logic power is supplied to the 9/440HR to run the processor board and axis module logic boards. The 24 volts are provided from a customer supplied transformer. Specifications for this supply are:
Transformer Input Voltage
9/440HR Input Voltage Range (Transformer Output)
125/240 V AC (85-265 V AC @50/60 Hz)
24V ac (19 - 28V ac, single phase @50/60 Hz) or 24V dc (18.75 - 31.25V)
Number of Axis Modules 1
2
3
4
3.5 A
4.4 A
5.2 A
6.0 A
On/Off connections are made through the Allen-Bradley On/Off Control assembly (8520-OFC). This assembly allows connection to the standard MTB panel on/off switch and should be used to supply power to your 24 V transformer. Figure 5B.16 On/Off Control Assembly
ALLEN- BRADLEY AC POWER
FUSE 8A/250V
L1 AC IN L2
Incoming AC Power 85--265 Volts AC
PE L1 AUX AC
Switched AC Out 85--265 Volts AC 8 amp max
L2 ON SW
COMMON OFF SW
5B-30
To MTB panel ON/OFF switch