Page 311

Section 5B 9/440HR CNC/Drive System

Wiring Board Battery Backup Connection

J5

P1 +

F1 Fuse

--

[ALL FUSES] [3A/125V]

XILINX

Drive Interface

TB5

WATCHDOG

Touch Probe Connection

SHLD GND TPIN +5V

F2 Spare Fuse

TB2

TB3

SHLD ANLGOUT2 RET SHLD ANLGOUT1 RET

RIO2 SHLD RIO1

TB4

Remote I/O Plug

J14

Analog Out 1 (spindle 1)

Analog Out 2 (spindle 2)

5B.4.1 Wiring a Touch Probe to the 9/440

The 9/440HR system module touch probe connection is made to connector TB5 on the wiring board. Table 5B.A shows the location of this connector and lists its terminal assignments.

Wiring Board

Table 5B.A TB5 Connector , 4 Plug-type Terminal Block Connections

P1 +

J5 J14

--

Terminal

XILINX

WATCHDOG

TB5

TB2 TB3 SHLD

GND

TPIN

+5V

TB4

1

Description

Signal Destination

+5V

Probe Power

Touch Probe

TP IN

Probe Fired Signal1

Servo Position Latch

GND

Touch Probe Common

Touch Probe

SHLD

Probe Shield connect at module only

The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as defined by the AMP parameter PROBE TRANSITION. Refer to your AMP reference manual for more information.

Important: The touch probe connector supports only +5V probing device applications.

5B-21

Page 312

Section 5B 9/440HR CNC/Drive System

The time delay between the 9/440HR receiving the touch probe trigger and latching the current axis position is negligible. However, you should be aware of any external delays that may introduce position “staleness” in the probing operation, especially at high probing speeds. It is a good idea to establish an offset for the distance between the actual location, as sensed by the probe at a very low speed, and the location sensed by the probe at the intended probing speed. The offset can then be added or subtracted to any future values obtained through probing. This helps make sure that if there are any external delays in the trigger signal, the position staleness shows up as a constant position offset error and is removed from the measurement (assuming the external delay is repeatable). The touch probe interface is intended for use with units that offer 5V dc compatible solid state relay outputs (see Figure 5B.10). Other configurations can be supported as long as the user operates within the published electrical specifications. The touch probe circuitry resident on the 9/440HR only responds to the trigger probe edge changes. Polarity transition (high to low or low to high) is selectable through the AMP parameter Probe Transition. Specify the probe transition in AMP as rising edge or falling edge. Once the active edge occurs, position data is captured by the module, and additional occurrences of the trigger signal have no effect until the probe is re-enabled under program control. Refer to the 9/Series CNC AMP Reference Manual, publication 8520-6.4, for more information. ATTENTION: From a safety standpoint, it is preferred that the touch probe relay be closed at rest and open when the touch probe stylus deflects. Then, if a wire breaks or shorts to ground, it will appear to the system as a probe fired and the probing cycle in process will stop commanding motion towards the part. The user should make every effort towards the fail-safe operation of the touch probe. Not all vendor’s touch probe control units conform to this safety consideration.

5B-22

Page 313

Section 5B 9/440HR CNC/Drive System

Figure 5B.10 shows the internal servo module circuitry that interfaces to the touch probe connector. It is shown here to assist you in determining whether your touch probe hardware is compatible. Figure 5B.10 Internal Circuitry Supporting the Touch Probe

9/440HR Wiring Board 5V common to encoder interface 1000 ohm

4 3 2 1

Shield GND TP IN +5V Power

470 ohm +5 V dc Encoder Power 11309-I

The following table indicates probing threshold voltages. Maximum Input Threshold (critical if the control has been configured to fire on the falling edge of the probe signal) indicates the voltage that the probe signal must fall below to be considered as “fired”. Minimum Input Threshold (critical if the control has been configured to fire on the rising edge of the probe signal) indicates the voltage that the probe signal must rise above to be considered as fired Probe Thresholds

Voltage at Threshold

Minimum Input Threshold (probe circuit)

3.06 (min)

Maximum Input Threshold (probe circuit)

2.18V dc (max)

5B-23

Page 314

Section 5B 9/440HR CNC/Drive System

To avoid misfires use the threshold values from the above table to determine the necessary signal voltage for steady state operation (probe not fired). For probes configured to fire on the falling edge the steady state voltage must remain above 3.06 volts. For probes configured to fire on the rising edge the steady state voltage must remain below 2.18 volts.

Wiring a Probe for Rising Edge Configurations Typical wiring of a simple contactor type touch probe configured to fire on the rising edge of the probe signal, requires the addition of a 1000 ohm pull down resistor. Figure 5B.11 shows a typical wiring diagram compatible with most probe designs configured to trigger on the rising edge of the probes signal. Figure 5B.11 Typical Wiring of a Touch Probe Configured for Rising Edge Trigger

9/440HR Wiring Board to encoder interface

1000 ohm

5V common 1000 ohm pull down resistor (customer supplied)

4 3 2 1 Probe Contact

470 ohm +5 V dc

5B-24

Page 315

Section 5B 9/440HR CNC/Drive System

Wiring a Probe for Falling Edge Configuration Figure 5B.12 shows a typical wiring diagram compatible with most probe designs configured to trigger on the falling edge of the probe signal. Figure 5B.12 Typical Wiring of a Touch Probe Configured for Falling Edge Trigger

9/440HR Wiring Board

Probe Contact

5V common to encoder interface 1000 ohm

4 3 2 1

470 ohm +5 V dc 11309-I

5B-25

Page 316

Section 5B 9/440HR CNC/Drive System

5B.4.2 9/440HR Remote I/O Connection

The remote I/O circuitry and connector are integral parts of the wiring board in the 9/440HR system module. Figure 5B.13 shows the remote I/O connector mounted on the 9/440HR wiring board. Wire connections for the remote I/O communications are made through the TB4 NODE ADAPT connector. Connect the wires for remote I/O as shown in the following figure. Refer to your 1771 I/O documentation for details on making remote I/O connections. Figure 5B.13 Remote I/O Connector in System Module

9/440HR System Module

Remote I/O Plug RIO2

RIO1

SHLD

Blue Shield Clear

TB4

Open Cover

9/440HR Remote I/O LED Assuming you have: made all necessary remote I/O communication connections on your 1771 I/O network configured your remote I/O port for the remote I/O network in AMP written PAL to set $RMON true during the first PAL foreground execution, and to handle input and output words ($RMI1 -- $RMI8 inputs to PAL and $RMO1 -- $RMO8 outputs from PAL.)

5B-26

Page 317

Section 5B 9/440HR CNC/Drive System

CNC Processor Board

Front of System Module

Serial Port A

R--I/O LED

5B.4.3 9/440HR Analog Out (TB2 and TB3)

You are ready to start receiving and transmitting remote I/O information. An LED is provided on the 9/440HR CNC processor board and is visible from the bottom of the system module. As remote I/O responds to commands, you should see this LED pattern: LED

Status

Description

Green R- I/O LED

ON

Active Link to PLC. This is the normal state when the RIO link is active.

FLASHING

The remote I/O link is active but the PLC is currently in program mode.

OFF

Remote I/O link is offline. The port is not being used, not configured in AMP correctly, not turned on with $RMON, or not attached to a 1771 device.

Video

Two auxiliary analog outputs are provided through the connectors labeled TB2 and TB3 of the 9/440HR Wiring Board. These connectors are typically used to command external analog spindle drive systems but can also be configured in AMP to control additional analog servo systems. Figure 5B.14 shows the location of ANALOG OUT connector and lists terminal assignments of this connector. Important: If positioning feedback is required for the spindle or analog servo system, its corresponding encoder feedback should be wired through one of the encoder feedback connectors and indicated as such in AMP. Figure 5B.14 Terminal Block TB2 and TB3, Plug-type Terminal Block Connections. P1 +

Wiring Board

J5 J14

-WATCHDOG

TB2

TB3

SHLD ANLGOUT2 RET SHLD ANLGOUT1 RET

XILINX

TB2 TB3

TB4

Analog Out 1 (spindle 1)

Analog Out 2 (spindle 2)

5B-27

Page 318

Section 5B 9/440HR CNC/Drive System

Connector

5B.4.4 Battery Backup

Description

Signal Destination

Analog Out

±10V Analog with no feedback

(typically spindle drive)

RET

Signal Return

(typically spindle drive)

SHLD shield connect at wiring board only

The memory for such items as part programs, tool offset/compensation data, and work coordinate offset data is stored on the processor board. In the case of a power failure, there is a super capacitor on the processor board that backs up this data for up to 5 days (at 40°C) on systems without extended program storage. This super capacitor recharges within 1 hour of power turn on if completely discharged. If you want to extend this backup time install the lithium battery pack that supports the data for: 9/440HR Memory Option:

Time (at 40°C Discharge):

standard

3 years with extended program storage

1 year

This battery pack is connected to the lithium battery connector (P1) on the wiring board as shown in Figure 5B.15. Batteries and the battery cable are included with the battery replacement kit. Figure 5B.15 Lithium Battery 9/440HR System Module Connect the battery pack to P1 on the wiring board. Wiring Board

Mount the battery pack to the inside of the module cover.

P1 +

-

Press Cover Release to Open

The lithium battery contains heavy metals and must be collected separately from other waste.

5B-28

Page 319

Section 5B 9/440HR CNC/Drive System

5B.5 Power Terminal Block Connection

All external power connections to the 9/440HR CNC/Drive are wired through the system modules power strip, located behind the front cover in the lower right corner. Input power is wired to this strip in two different voltages: 24 V Logic Power -- this is 24 V AC or 24 V DC. The logic power is used to operate the processors in the system module, axis module logic boards, and power the encoders. Drive Power -- this is 324-528 V AC, three phase, 50/60 Hz. The drive power is used to supply the drive portion of the 9/440HR the voltages necessary to power the axis modules and the servo motors. To this Power Strip Connector

Connect:

W1

+24 V Logic Power

W2

24 V Logic Power common

U, V, W

380/460V AC, three- phase power (not phase sensitive)

PE

System Ground Bar

DC+, INT, COL

Shunt resistor connection. When the jumper exists between INT and COL the internal 200 W shunt is used. When using the optionally purchased 1000 W shunt the jumper is removed and the new shunt is installed between DC+ and COL.

All connectors on the power strip support a maximum of AWG 12 gauge solid wire.

9/440HR System Module

Wiring Board

Power Terminal Block

E-Stop connections (TB1)

DC+

INT

COL

W1

W2

U

V

W

PE

5B-29

Page 320

Section 5B 9/440HR CNC/Drive System

5B.5.1 On/Off Control and 24V Logic Power

24 Volt logic power is supplied to the 9/440HR to run the processor board and axis module logic boards. The 24 volts are provided from a customer supplied transformer. Specifications for this supply are:

Transformer Input Voltage

9/440HR Input Voltage Range (Transformer Output)

125/240 V AC (85-265 V AC @50/60 Hz)

24V ac (19 - 28V ac, single phase @50/60 Hz) or 24V dc (18.75 - 31.25V)

Number of Axis Modules 1

2

3

4

3.5 A

4.4 A

5.2 A

6.0 A

On/Off connections are made through the Allen-Bradley On/Off Control assembly (8520-OFC). This assembly allows connection to the standard MTB panel on/off switch and should be used to supply power to your 24 V transformer. Figure 5B.16 On/Off Control Assembly

ALLEN- BRADLEY AC POWER

FUSE 8A/250V

L1 AC IN L2

Incoming AC Power 85--265 Volts AC

PE L1 AUX AC

Switched AC Out 85--265 Volts AC 8 amp max

L2 ON SW

COMMON OFF SW

5B-30

To MTB panel ON/OFF switch