Page 321
Section 5B 9/440HR CNC/Drive System
Logic power should be wired so that if the 24 V is not available to the system module, it will open the drive contactors and disable 3 phase drive power (see Figure 5B.20). Figure 5B.17 Connecting On/Off Power Control Assembly and 24V Transformer
ALLEN- BRADLEY AC POWER FUSE 8A/250V
AC IN
AUX AC
To local cabinet ground bus
Incoming Power 85- 265 V ac
9/440HR Power Strip
Low High
BT02 Monochrome or Color operator panel power supply
PE L1
DC+
L2 PE L1 4 amp max draw
L2 ON SW
COMMON OFF SW
U
INT
W1
W2
V
W
PE
Input 85-265 V ac ON COM
ON/OFF Control Assembly
COL
OFF
Customer supplied 24V transformer Output 24 V ac or 24 V dc non-polarized
E-STOP
15 AMP Customer Supplied Fuses
COM RESET
Noise suppressor
MTB Panel
ATTENTION: You must make sure logic power (24V) is applied to the system module and the system module is out of E-STOP before you allow 3 phase power to be enabled.
5B-31
Page 322
Section 5B 9/440HR CNC/Drive System
If 24 V power is required for other devices in your machine system, you can use a 24 V power supply in place of the 24 V transformer as shown in Figure 5B.18. Figure 5B.18 Connecting On/Off Power Control Assembly and 24V Power Supply
ALLEN- BRADLEY AC POWER
To local cabinet ground bus
Incoming Power 85- 265 V ac
9/440HR Power Strip
Low High
BT02
FUSE 8A/250V
PE
Monochrome or Color operator panel power supply
U
COL INT DC+
L1 AC IN
L2 PE
W1
L1 AUX AC L2 ON SW COMMON OFF SW
Customer- supplied 24V Power Supply
ON COM OFF
ON/OFF Control Assembly
Output 24 V ac or 24 V dc non-polarized
W2
V
W
PE
Noise suppressor 199-ISMAxx On Off Relay Bulletin 100 A30--Nxx
C C1
15 AMP Customer- supplied Fuses
E-STOP COM RESET
MTB Panel
5B.5.2 Drive Power Three- phase
Three--phase power to the 9/440HR must be 324-528 V AC, 50/60 Hz. The drive power is used to supply the drive portion of the 9/440HR the voltages necessary to power the axis modules and the servo motors. All power connectors on the 9/440HR power strip accept AWG 12 gauge solid wire. Refer to local codes for required wire type and gauge.
5B-32
Page 323
Section 5B 9/440HR CNC/Drive System
Grounded vs Ungrounded Three- phase The 9/440HR CNC/Drive comes from the factory set for three--phase grounded systems. If your facility uses an ungrounded three--phase 360/480 volt system, you must move a jumper in the 9/440HR system module. This jumper will connect an internal resistor that helps keep high voltage static, that can be typical of ungrounded three phase systems, from building up in the system module. Jumper Setting
Three Phase Power
J27 to J26 (factory setting)
Grounded system
J27 to GND3
Ungrounded systems
GND3
J26
Wire Jumper
J27
Figure 5B.19 Three- phase Jumper
Open cover
9/440HR System Module
5B-33
Page 324
Section 5B 9/440HR CNC/Drive System
Figure 5B.20 Recommended Connection of Three- phase Drive Power 9/440HR Power Strip
Bussman FRS- R- 20A (class RK-5) 600 V AC (qty 3)
COL W1 DC+ INT W2
U
V m3
W PE m2
Three-phase input 360 or 480V AC m1 m
Bulletin 100 Contactor Power
AC Bulletin 100- A30N x 3 (surge protector required) or DC Bulletin 100- A30NZ x 3 Noise suppressor c1 c
Customer supplied 24V Power Supply Output 24 V ac or 24 V dc
Customer Supplied E-STOP Control Relay
E-STOP Connector TB1 7
Noise suppressor Customer Supplied Fuse
Other Customer Controlled E-STOP Status Relays
E-STOP status contact (30V dc 1.4A)
1
ATTENTION: Brake control should not be directly released by the E-STOP status relay (or your customer supplied E-STOP control relay). Brakes should only be released by the PAL logic when it has determined that the 9/440HR is in full control of the servo motors and the control is out of E-STOP. See the description of the PAL flag $PFLT.15 for detail on how to test drive status.
5B-34
Page 325
Section 5B 9/440HR CNC/Drive System
5B.6 Connecting Axis Modules
The Axis Module provides terminating points for the motor power, thermal sensor and brake. Axis module wiring is identical for all module ratings. Refer to Figure 5B.21 and the paragraphs that follow for detailed information. Figure 5B.21 Axis Module Connections
U1
V1
W1 PE2 PE1 PE3
TB1 and TB2 (Located on Bottom of Module)
Motor Wiring Allen-Bradley 1326-CPB1xxx cables must be used for connection to the motor. The motor wiring size is determined by the continuous and overload current requirements (RMS Duty Cycle), NEC and local codes. In general, motors operated with the 1394 should not require wire sizes larger than those accepted by the motor terminal blocks. In addition, the motor leads must be twisted throughout their entire length to minimize radiated electrical noise. The maximum motor wire sizes that the 1394 Axis Module terminal block will accept are dependent upon axis module selection (see your 1394 users manual).
5B-35
Page 326
Section 5B 9/440HR CNC/Drive System
See page 5B-12 for details on high--resolution feedback device cables (1326-CECU--x). 1326AB servo motors have integral thermal protection. This contact must be connected in the E-STOP string for motor overload protection. Connections are performed through the front panel terminal block as shown in Figure 5B.21. Refer to the information below and the Interconnect Drawings on page 5B-40 for further information. Table 5B.B Motor Power Terminations Terminal
Description
Wire/Pin Number
U1
Motor Power A
1
V1
Motor Power B
2
W1
Motor Power C
3
PE1
Axis Ground
Ground Bar
PE2
Motor Ground
8
PE3
Overall Shield
7
Thermal and Brake Leads The motor thermal sensor and brake leads (if used) are connected to the Axis Module at TB1 & TB2. See Figure 5B.21 for location and Table 5B.C for terminations.
5B-36
Page 327
Section 5B 9/440HR CNC/Drive System
Table 5B.C Thermal Sensor and Brake Terminations Terminal
Description
Wire/Pin Number
TB1-1, 2
Thermal Sensor Input from Motor Cable string axis modules
TB1-3, 4
Brake 24V DC Input from Motor Cable user brake
TB2-1, 2
Brake 24V DC To Brake Control
5, 9
TB2-3, 4
Thermal Sensor Output to Fault System
4, 6
TB1 All Axis modules
Axis Module
6
(applying 24V DC releases brake)
TB2 Axis module 1
Brake
TB2 Axis module 2
User Brake Control Thermal String (connect to E-STOP String)
4 5
9
Motor
Thermostat
TB2 Axis module 3
User Brake Control
TB2 Axis module 4
User Brake Control
User Brake Control
ATTENTION: Brake control should not be directly released by the E-STOP status relay (or your customer supplied E-STOP control relay). Brakes should only be released by the PAL logic when it has determined that the 9/440HR is in full control of the servo motors and the control is out of E-STOP. See the description of the PAL flag $PFLT.15 for detail on how to test drive status.
5B-37
Page 328
Section 5B 9/440HR CNC/Drive System
5B.7 9/440HR LEDs
9/440HR CNC/Drive has 4 LEDs on the system module and one LED on each axis module in the system. The LEDs operate as follows. System Module LEDs The system module has 4 LEDs. They are: LED
Indicates
XILINX
Under normal operation this LED is on. If it turns off while the system module is under power it indicates a XILINX hardware fault. Contact your local Allen- Bradley Service.
WATCHDOG
Under normal operation this LED is on. If it turns off while the system module is under power it indicates the watchdog has timed out and a processor failure has occurred. Contact your local Allen-Bradley Service.
R- I/O
Only available on systems with remote I/O. This LED illuminates when the remote I/O link is communicating. See page 5B-27.
STATUS
This is identical to the Watchdog LED but is visible through the system modules front cover.
9/440HR System Module
Wiring Board
XILINX
Press Cover Release to Open Open Cover
WATCHDOG
Status LED
R-I/O LED (visible from under system module in front of serial port B)
Check your 9/Series CRT for any drive faults that may have occurred and are displayed as an error. 5B-38
Page 329
Section 5B 9/440HR CNC/Drive System
Axis Module LEDs The Axis module has a Status LED visible thru the front cover. It is: LED
Indicates
STATUS
Steady Green Flashing Green Flashing Red/Green Flashing Red Steady Red bus up, axis enabled bus up, axis not enabled ready, bus not up fault present hardware malfunction
For more details on how to diagnose and troubleshoot your axis module refer to the 1394 Digital AC Multi-Axis Motion Control System Users Manual (publication 1394-5.0)
5B.8 General Wiring Overview
The following figure shows a typical interconnect diagram for a 9/440HR CNC to 1326AB motors. Note this figure illustrates only one servo motor with optional feedback encoder. The 9/440HR CNC can support up to four servo’s and two spindle drives.
5B-39
Page 330
Section 5B 9/440HR CNC/Drive System
Figure 5B.22 Wiring Overview For 9/440HR CNC Processor Board
Fiber Optic I/O Ring
TB1
Video Port
J8
Serial Port B
J7
Serial Port A
J6
1 2 3 4 5 6 7
MTB E-Stop Connections External Customer E-Stop String
M1
E-STOP Status String
1394 Axis Module
Analog Out 1
Analog Out 2
Remote I/O
1 2 3 4 5 6
TB2 Wiring Board
1 2 3
RIO1 TB4
Thermostat and Brake Feedthru
TB1 TB3
U1 V1 W1 PE1 PE2 PE3 4 3 2 1 TB5
SHLD
1 2 3 4
1
Touch Probe
M1 M1 M1 Three-phase input 360-480V AC
DC+ COL INT W1 W2 U V W PE
To Cabinet Ground Bar Ground Stud
5B-40
3
8
T1 T2 T3
7
GND
6
4
5
9
B2 B1 K2 K1
4 3 2 1 To next axis and User Brake Control Input
Brake
9/440HR System Module
User- supplied 24V AC or 24V DC (non-polarized), 15A
2
RIO2
9/440HR Power Supply
TB2
Feedback Board Encoder Inputs J1, J2, J3, or J4
Encoder Inputs J9, J10, J11, or J12
Servo Motor 3 2 11 12 10 8 9 7 6 5 4 1 1 12 11 9 78 6 5 3 2 15 16
A B C D
Thermostat
Ground Bar
Encoder
E F G H I J G A H I B C J D F
1326AB Motor
AB 845H Encoder