Page 361

Section 7A Connecting Components

7A.2 Cable Diagrams

The cables and connectors shown in the previous figures are covered in the following table. For detailed information on a specific connector, refer to the section that covers the module on which the connector is located. ATTENTION: Incorrect wiring of the following cables and connectors may cause damage to their respective modules.

Table 7A.A Cable and Connector List Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C01

9/230

Main Power Supply BT04

ON/OFF Switch Signal Cable

MTB Panel BT20

Prepared by Customer

C01

ON SW

L1

COM OFF SW

L2

ON ac IN

PE L1 AUX ac L2

24V dc 24V dc RTRN

COM OFF E-Stop 19419

COM RESET

Power Supply

MTB Panel

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9491

Miscellaneous

Line Drop Limit

7A-13

Page 362

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C01

9/260 and 9/290 only

Main Power Supply BT04

ON/OFF Switch Signal Cable

MTB Panel BT20

Prepared by Customer

BT04

BT20

L1 L2 ac IN ON PE COM

H L

AUX ac

OFF

C01

E-Stop

ON SW

COM

COM RESET

OFF SW

19574

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9491

Miscellaneous

Line Drop Limit

Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C01

9/440 (all) only

On/Off Power Control Module

ON/OFF Switch Signal Cable

MTB Panel BT20

Prepared by Customer

On/Off Power Control Module BT20

L1 L2 ac IN ON

PE

COM

L1

L2

AUX ac

OFF

C01

E-Stop

ON SW

COM

COMMON

RESET OFF SW

7A-14

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9491

Miscellaneous

Line Drop Limit

Page 363

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Control

Cable No.

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

9/230

C02

Main Power Supply BT04 ac Power Source Cable

External ac Power Source

Prepared by Customer

BT04

AC power source

C02

AC power source L1

ON SW

High Low ac IN

COM

L2 PE

OFF SW

Ground

24V dc RTRN

L1 AUX ac L2

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Per Local Codes

Miscellaneous

Line Drop Limit

24V dc

19420

Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C02

9/260 and 9/290

Main Power Supply BT04 ac Power Source Cable

External ac Power Source

Prepared by Customer

BT04 ac power source

High ac power source

Low

C02 ac IN

L1 L2

Ground

PE AUX ac

L1 L2 ON SW COM OFF SW 11207-I

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Per Local Codes

Miscellaneous

Line Drop Limit

7A-15

Page 364

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C02

9/440 (all)

On/Off Power Control Module ac Power Source Cable

External ac Power Source

Prepared by Customer

On/Off Power Control Module ac power source

High ac power source

Low

C02 L1 ac IN L2

Ground

PE L1 AUX ac L2 ON SW COMMON OFF SW

7A-16

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Per Local Codes

Miscellaneous

Line Drop Limit

Page 365

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C03

9/230

Main Power Supply BT04

Power Supply Cable

Operator Panel Power Supply on Operator Panel or on Removable Operator Panel Interface Assembly

Prepared by Customer

L1

ON SW COM

L2

OFF SW

PE ac IN

C03

High Low

L1

24V dc

Monochrome Operator or color Panel Power Supply

AUX ac L2

24V dc RTRN

To local cabinet ground bus

Power Supply

BT02

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9409

Miscellaneous

Line Drop Limitation

7A-17

Page 366

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C03

9/260 and 9/290

Main Power Supply BT04

Power Supply Cable

Operator Panel Power Supply on Operator Panel or on Removable Operator Panel Interface Assembly

Prepared by Customer

BT04 BT02

L1 ac IN

C03

L2

High Monochrome or color Operator Panel Low Power Supply

PE L1 AUX ac

L2

ON SW

To local cabinet ground bus

COM OFF SW

Power Supply

7A-18

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9409

Miscellaneous

Line Drop Limitation

Page 367

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C03

9/440 (all)

On/Off Power Control Module

Power Supply Cable

Operator Panel Power Supply on Operator Panel or on Removable Operator Panel Interface Assembly

Prepared by Customer

On/Off Power Control Module BT02

L1 ac IN

C03

L2

High Monochrome or color Operator Panel Low Power Supply

PE L1 AUX ac

L2

ON SW

To local cabinet ground bus

COMMON OFF SW

Power Supply

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9409

Miscellaneous

Line Drop Limitation

Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C04

9/260 and 9/290

Main Power Supply BT04 dc Output Cable

Motherboard J1

Included with Main Power Supply

9/230

Processor Board P12 pwr fail (white) 5.15 vdc main gnd/gnd sense (black) gnd (black) - 15 vdc (yellow) 5.15 v main/5 v sense 5.15 vdc main (red) gnd (black) +15 vdc (brown)

1 2 3 4 5

1 2 3 4 5

6 7 8 9

6 7 8 9 pwr fail (white) 5.15 vdc main gnd/gnd sense (black) gnd (black) - 15 vdc (yellow) 5.15 v main/5 v sense 5.15 vdc main (red) gnd (black) +15 vdc (brown)

5.35 vdc pigtail to servo card (blue)

1

1

5.35 vdc pigtail to servo card (blue)

7A-19

Page 368

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C05

9/260 and 9/290

Motherboard TB1

E-Stop String Cable

Machine Circuits

Prepared by Customer

9/230

Processor Board TB1

9/440 (all)

System Module TB1

E-Stop

MacHINE

TB1

Extreme overtravel switches

Remote E-Stop button

Common Reset Customer E-Stop String

C05

Drive System Ready Motor thermal switches

E-Stop Status Contacts DRIVES ENCLOSURE

If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.

7A-20

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9407

Miscellaneous

Line Drop Limitation

Page 369

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C06

9/260 and 9/290

Motherboard TB1

E-Stop Reset Cable

MTB Panel BT20

Prepared by Customer

9/230

Processor Board TB1

9/440 (all)

System Module TB1 TB1 ON E-Stop Common

COM OFF E-Stop

Reset C06

Customer E-Stop String E-Stop Status Contacts

COM

Important: If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.

BT20

RESET

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9491

Miscellaneous

Line Drop Limitation

7A-21

Page 370

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C07

9/260 and 9/290

Motherboard Port B J7

RS-232/RS-422 Serial Interface Cable

MTB Panel CN56F

Prepared by Customer

9/230

Processor Board Port B J7

9/440 (all)

System Module Port B J7 shield rda rdb sda sdb csa csb rsa rsb dma dmb tra trb gnd not used

1 3 10 2 9

1 3 15 2 14

5 12 4 11 6

5 17 4 16 6

13 8 14 7 N.C.

18 20 19 7 N.C. 8

Belden 9507 - 24 Gauge Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

15- pin D-shell (has pins) 8520-D15M

Belden 9507

25- pin D-shell (has sockets) 8520-D25FS

1

1 The maximum length of this cable depends on the length of cable C25. The combined length of cables C07 and C25 may not exceed 15 m (50 ft).

7A-22 shield rda rdb sda sdb csa csb rsa rsb dma dmb tra trb gnd not used rra