The text of a manual ยท part 38 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 371 to 380
Pages 371 to 380 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 371
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C08
9/260, 9/290, and 9/440 (all)
Port A
RS-232 Serial Interface Cable
I/O Device
Prepared by Customer
-------
N/A on the 9/230
---------------
-------------------
-----------------
------------- shield sd rd rs cs signal ground
1 2 3 4 5
1 2 3 4 5
7
7 shield sd rd rs cs signal ground
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
15- pin D-shell (has pins) 8520-D25M
Belden 9504
Miscellaneous
15m (50 ft)
7A-23
Page 372
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C09
9/260 and 9/290
Motherboard J8
Video Signal Cable
CN19M on Operator Panel or on Portable Operator Panel Interface Assembly
Prepared by Customer
9/230
Processor Board J8
9/440 (all)
System Module J8 gnd (shield) red (l) red (h) green (l) green (h) blue (l) blue (h) not used not used clock (l) clock (h) h- sync (l) h- sync (h) v- sync (l) v- sync (h)
1 gnd (shield) red (l) red (h) green (l) green (h) blue (l) blue (h) not used not used clock (l) clock (h) h- sync (l) h- sync (h) v- sync (l) v- sync (h)
1
7A-24
2 3 4 5 6 7 8
2 3 4 5 6 7 8
9 10 11 12 13 14
1
N.C. N.C.
N.C. N.C.
9
N.C. N.C. N.C. N.C. N.C. N.C.
N.C. N.C. N.C. N.C. N.C. N.C.
11
10
12 13 14 15
15
9
10
10
11
11
13
N.C. N.C. N.C. N.C.
N.C. N.C. N.C. N.C.
3 4 5 6 7 8
1
9
12
2
12 13
14
14
15
15
2 3 4 5 6 7 8 shield rda rdb sda sdb csa csb rsa rsb dma dmb tra trb gnd
Shield (pin 1) on the monochrome operator panel is not internally connected to signal common or chassis ground.
Monochrome monitor rra shield rda rdb sda sdb csa csb rsa rsb dma dmb tra trb gnd
Shield (pin 1) on the color operator panel is internally connected to signal common and chassis ground.
Color monitor Indicates twisted pairs 11211-I rra
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
15- pin D-shell (has pins) 8520-D15M
Belden 9830 (monochrome) Belden 9832 (color)
15- pin D-shell (has sockets) 8520-D15F
15m (50 ft)
Page 373
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C10
9/Series (All)
XMIT Connector (Red)
Fiber Optic Cable
Output Connector (Black)
Prepared by Customer
Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Refer to appendix A for additional information on fiber optic cables and connectors. Connector Kit
Cable Type
Connector Kit
Max. Cable Length
8500-FOPS2
8500-FOC1 (100 ft) 8500-FOC5 (500 ft)
8500-FOPS2
27m (90 ft)
2 Optical connectors are provided with each module. The catalog number listed under the connector type refers to a spare connector kit. Each kit contains an optical input connector and an optical output connector.
7A-25
Page 374
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C11
9/260 and 9/290
Motherboard P3
Fast I/O Interface Cable
Miscellaneous I/O Devices (examples shown)
Purchased by customer from independent vendor.
------
N/A on the 9/230 and 9/440 (all)
-----------------------
----------------------
--------------------
----------------- fast_I1 com fast_I2 com fast_I3 com fast_I4 com fast_O2 com fast_O3 com fast_O4 com fast_O5 com
Fast_I1
1 2
COM Fast_I2
3 4 5 6
COM Fast_I3 COM Fast_I4
7 8 9 10 11 12 13 14 15 16
COM Fast_O1 COM Fast_O2 COM Fast_O3 COM Fast_O4 COM
+ -
Input #1
+ -
Input #2
+ -
Input #3
+ -
Input #4
+ -
Output #1
+ -
Output #2
+ -
Output #3
+ -
Output #4 11212-I
Allen-Bradley recommends that you use a terminal block to simplify the wiring of the fast I/O. Refer to the section on fast I/O in 10A-63. Allen-Bradley also recommends that you purchase a pre-made cable to connect the terminal block to the control. Important: The Fast I/O feature is an application specific feature. For additional information on this feature contact your Allen-Bradley sales office. Connector On End of Cable 16- pin (has sockets)
7A-26
Cable Type Ribbon
Connector On End of Cable Miscellaneous
Max. Cable Length ----------
Page 375
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C12
9/260 and 9/290
Analog or Digital Servo Module(s) CN1
Servo Module Interface Cable
Motherboard P4, P5, P6 (P5 available on 9/290 only)
Included with Servo Module
------
N/A on the 9/230
-----------------------
----------------------
--------------------
-----------------
C13
9/Series All
Motherboard or Processor Board P1
Battery Backup Cable (dc)
Lithium Battery
Part of Battery Assembly
7A-27
Page 376
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C14
9/230, 9/260, 9/290 8520 Digital
9/230 Processor (8520-DSP only) servo connectors (J1,J2, or J3) or 4-axis Digital Servo Module (8520-ENC4) Servo Connector (J1, J2, J3, or J4)
Drive and Inc. Encoder Signal Cable
8500 Servo Motor Encoder and 8520 Digital Servo Amplifier CNA1-CNA3
Prepared by Customer
With 5V dc incremental encoders
44- pin D-shell cha_hi cha_lo chb_hi chb_lo chz_hi chz_lo gnd gnd gnd gnd gnd not used +5v_enc +5v_enc +5v_enc +5v_enc +5v_enc +5v_enc chu_hi chu_lo chv_hi chv_lo chw_hi chw_lo not used not used enable /enable not used status /status pwm_u_hi /pwm_u_lo pwm_v_hi /pwm_v_lo pwm_w_hi /pwm_w_lo Ia /I a Ib /I b
11 41 10 40 39 9 15 16 19 28 29 31 20 21 22 24 25 26 2 32 3 33 4 34
A B C D E F G a channel output /a channel output b channel output /b channel output z channel output /z channel output 0v 1
Indicates twisted pair Incremental Encoder Connection1
H +5v dc 1
2
K u channel output 2 L /u channel output M v channel output2 N /v channel output 2 P w channel output 2 R /w channel output 2 J frframe ground Shield wires, no connection at control end 1 enable for either shield wire. 2 /enable 3 shield 6 status 7 /status 10 pwm_a 11 /pwm_a Drive Connection2 12 pwm_b 13 /pwm_b 14 pwm_c 15 /pwm_c 17 l a 18 /l a 22 l b 23 /l b
13 43 8 38 35 5 36 6 37 7 14 44 12 42
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
44- pin Miniature D-shell (has pins) 8520-MD44M
Belden 8312 (encoder cable) Belden 9833 (drive signal cable)
MS Style E20-29S 8520-C17F to encoder 1
25m (82 ft)
Honda MR-25LF (has sockets) 8520-H25F to drive2 1 These cables are 22 AWG twisted pairs. Multiple lines (4) must be used to provide the equivalent of 16 AWG encoder power leads.
2 The U, V, and W channels are used for motor phasing only.
7A-28
Page 377
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C14
9/230, 9/260, 9/290 8520 Digital
9/230 Processor (8520-DSP only) servo connectors (J1,J2, or J3) or 4-axis Digital Servo Module (8520-ENC4) Servo Connector (J1, J2, J3, or J4)
Drive and Abs. Encoder Signal Cable
8500 Servo Motor Encoder and 8520 Digital Servo Amplifier CNA1-CNA3
Prepared by Customer
With 5V dc absolute encoders
44- pin D-shell cha_hi 11 cha_lo 41 chb_hi 10 chb_lo 40 chz_hi 39 chz_lo 9 gnd 15 gnd 16 gnd 19 gnd 28 gnd 29 /enable 31 +5v_enc 20 +5v_enc 21 +5v_enc 22 +5v_enc 24 +5v_enc 25 +5v_enc 26 chu_lo 34 ext_bat 23 not used not used enable 13 not used 43 not used status 8 /status 38 pwm_u_hi 35 /pwm_u_lo 5 pwm_v_hi 36 /pwm_v_lo 6 pwm_w_hi 37 /pwm_w_lo 7 I a 14 /I a 44 I b 12 /I b 42
A B C D E F G a channel output /a channel output b channel output /b channel output 1 z channel output /z channel output 1 2 0v
Indicates twisted pair
Absolute Encoder Connection1 H
5v (power supply)
R S T J encoder reset pin 0v (battery) +v (battery) frame ground
1 enable 2 /enable 3 shield 6 status 7 /status 10 pwm_a 11 /pwm_a 12 pwm_b 13 /pwm_b 14 pwm_c 15 /pwm_c 17 l a 18 /l a 22 l b 23 /l b
2
Shield wires, no connection at control end for either shield wire.
Drive Connection2
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
44- pin Miniature D-shell (has pins) 8520-MD44M
Belden 8312 (encoder cable) Belden 9833 (drive signal cable)
MS Style E20-29S 8520-C17F to encoder 1
25m (82 ft)
Honda MR-25LF (has sockets) 8520-H25F to drive2 1 The Z channel output is used for the marker signal.
2 These cables are 22 AWG twisted pairs. Multiple lines (4) must be used to provide the equivalent of 16 AWG encoder power leads.
7A-29
Page 378
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C15
All 9/Series
1746 I/O Rack
1746 I/O Device Cable
External I/O (Analog and Digital)
Prepared by Customer
1746 Digital Input Modules L1
1746-IA16 IN 0 IN 2 IN 4 IN 6
100/120 V ac
IN 8 IN 10 IN 12 IN 14
L2
1746-IB16
+dc
IN 0
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
24 V dc
IN 9
IN 8 IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
---dc ac COM
IN 1 IN 3 IN 5 IN 7 IN 9 IN 11 IN 13 IN 15 dc COM ac COM dc COM
COMMONS CONNECTED INTERNALLY
COMMONS CONNECTED INTERNALLY
1746 Digital Output Modules
1746-OA16 L1
V ac1 OUT 1
100/240 V ac L2
OUT 3 CR
OUT 5
CR
OUT 7
OUT 9 OUT 11 CR
OUT 13
CR
OUT 15
1746-OW16 +dc or L1 OUT 0 OUT 2 OUT 4 OUT 6
V dc V ac
CR CR dc COM or L2
CR CR
L1
V ac 2 OUT 8 OUT 10 OUT 12
CR
OUT 14
CR
100/240 V ac
CR CR
L2
V dc or V ac 1 OUT 0 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7
V dc or OUT 9 V ac 2 OUT 8 OUT 11 OUT 10 OUT 13 OUT 12 OUT 15 OUT 14
CR CR
+dc or L1
CR
VDC VAC
CR dc COM or L2
7A-30
Page 379
Section 7A Connecting Components
Table 7A.A Cable and Connector List (C15 continued)
1746 Analog I/O Modules
OUTPUT INPUT POWER
ANALOG
(0) IN 0+ (1) IN 0(2) ANL COM (3) IN 1+ (4) IN 1-
+ Analog source -
(0) IN 0+ (1) IN 0-
PE
(2) ANL COM (3) IN 1+ (4) IN 1-
(5) ANL COM
(5) ANL COM
(6) NOT USED
(6) NOT USED
(7) OUT 0
(7) OUT 0
(8) ANL COM
(8) ANL COM
(9) NOT USED
(9) NOT USED
(10) OUT 1
(10) OUT 1
(11)ANL COM
(11)ANL COM
Jumper unusedinputs
+ Analog load Do not jumper unused outputs
PE
1746- NIO4V Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Terminal Strip
Determined by I/O device
Determined by I/O device
Determined by I/O Device
7A-31
Page 380
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C16
All 9/Series
1746 I/O Rack
1746 I/O Power Cable
Customer Power Supply
Prepared by Customer
Voltage Selection Jumper
100/120 V Power Connection 200/240 V PWR OUT +24 V dc PWR OUT COM L1, 120/240 V L2, V ac NEUTRAL push latch up from underneath to open the door, PROTECTIVE EARTH
ATTENTION: Turn off power lines before connecting power; failure to do so could cause injury to personnel and/or equipment.
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Supplied
#14 AWG
To customer power supply
N/A
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C17
All 9/Series
Remote I/O Port
1770-CD
PLC Scanner
Purchased from Allen-Bradley Cat. no. 1770-CD
7A-32