The text of a manual · part 39 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 381 to 390
Pages 381 to 390 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 381
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C18
9/260 and 9/290
3 Axis Digital Servo Module CN5-CN7
Encoder Signal Cable
Servo Motor Encoder
Prepared by Customer
24 AWG wire 16 AWG wire gnd gnd enc_5v enc_5v enc_15v enc_15v n.c. pu /pu pv /pv pw /pw pz /pz pa /pa pb /pb shield
1 2 3 4 5 6 7 8 9 10
G N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
/a channel output
H J S T K L
With 5V dc incremental encoders
M N P R E
11 12 13 14 15 16
Indicates twisted pair
F A
17 18 19 20
B C D
Shield wire, no connection at encoder end
24 AWG wire 16 AWG wire gnd gnd enc_5v enc_5v enc_15v enc_15v bat_+ not used not used not used not used reset not used pz /pz pa /pa pb /pb shield
1 2 3 4 5
G H N.C.
6 7 8 9 10
N.C.
11 12 13 14 15 16
N.C.
ground
J S T K L
N.C.
N.C.
N.C. N.C.
N.C. N.C.
N.C.
N.C.
N R
N.C.
N.C.
P E F
With absolute encoders
M
A B C
17 18 19 20
11213-I
D
Shield wire, no connection at encoder end
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Honda MR-20LM (has pins) 8520-H20M
Belden 8310 (Incr. encoder) 3 Belden 8308 (Abs. encoder) 3
MS Style E20-29S 8520-C17F
25m (82 ft)
3 These cables are 22 AWG twisted pairs. Multiple lines (4) must be used to provide the equivalent of the 16 AWG encoder power leads. Instructions are provided in the connector kit.
7A-33
Page 382
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C19
9/230, 9/260 and 9/290
8520 Digital Servo Amplifier TB1, TB4
8520 Digital Servo Motor Power Cable (230V ac)
8520 Digital Servo Motor Power Connector
Prepared by Customer
Example for the 2AX--D Amplifier connections to motor one (Series A or B, without brake) 1 2 3 4 TB4
C19
13
TB1
Shield
N.C.
12
G
F Thermal Protector E
11 10 9 8
D
7
B
C
6 3 conductor 12 Ga. - Motor 2 conductor 16 Ga. - Thermal 1 conductor 16 Ga. - Ground 2 conductor 16 Ga. - not used 1 Shld.
4 3 2 1
A
For 1326-CB-AB 12 Ga.
5
Tie Shield to ground at both TB1 and Servo Motor
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
10 Ga. (TBD)
(E24-10S) (8520-BC7F)
20m (65 ft)
12 Ga. 1326-CP-AB100 (100 ft) ” ” -AB200 (200 ft) ” ” ” ” 1326-CP-AB1500 (1500 ft)
MS Style E20-15S 8520-ac7F
An example of the 2AX-D 8520 digital servo amplifier connection to an A and B series 8520 digital servo motor with brake is shown in the next cable drawing. ATTENTION: The pin layout and pin assignments of the connector on the A series servo motor with brake are different than the pin layout and pin assignments of the connector on the B series 8520 digital servo motor with brake. Refer to appendix B for additional information.
7A-34
Page 383
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C19
9/230, 9/260 and 9/290
8520 Digital Servo Amplifier TB1, TB4
8520 Digital Servo Motor Power Cable (230V ac)
8520 Digital Servo Motor Power Connector
Prepared by Customer
-----------------------
----------------------
--------------------
-----------------
------
Example for the 2AX--D Amplifier connectors to motor one (Series A, with brake) 1 2 3 4 C19 Shield TB1 TB4 N.C. A D 13 From Brake energizing circuit C Shield 12 H 11 Thermal Protector G 10 E 9 8 B 7 I 6 F For 1326-CB-AB 12 Ga. 5 3 conductor 12 Ga. - Motor 4 2 conductor 16 Ga. - Thermal 1 conductor 16 Ga. - Ground 3 2 conductor 16 Ga. - Customer Brake Circuit 2 1 Shld. 1 Tie Shield to ground at both TB1 and Servo Motor
Example for the 2AX--D Amplifier connectors to motor one (Series B, with brake) TB1 13 12 11 10 9 8 7 6 5 4 3 2 1
1 2 3 4
TB4
C19
Shield N.C.
Shield
From Brake energizing circuit Thermal Protector
For 1326-CB-AB 12 Ga.
C I H B A G F E D
3 conductor 12 Ga. - Motor 2 conductor 16 Ga. - Thermal 1 conductor 16 Ga. - Ground 2 conductor 16 Ga. - Customer Brake Circuit 1 Shld.
Tie Shield to ground at both TB1 and Servo Motor
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
10 Ga. (TBD)
(E24-11S) (8520-BC9F)
20m (65 ft)
12 Ga. 1326-CB-AB100 (100 ft) ” ” -AB200 (200 ft) ” ” ” ” 1326-CB-AB1500 (1500 ft)
MS Style E20-18S 8520-ac9F
7A-35
Page 384
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C20
9/260 and 9/290
8520 3 Axis Digital Servo Module CN2-CN4
8520 Digital Servo Amplifier Signal Cable (PWM)
8520 Digital Servo Amplifier CNA1-CNA3
Prepared by Customer enable /enable shield shield shield status /status pwm_a /pwm_a pwm_b /pwm_b pwm_c /pwm_c la /la shield shield shield lb /lb
1 2 3 4 5 6 7
N.C. N.C. N.C.
N.C. N.C.
N.C. N.C. 8 9 10 11 12 13
N.C.
14 15 16 17 18 19 20
N.C. N.C. N.C.
N.C. N.C. N.C.
N.C. N.C.
7A-36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 enable /enable shield shield shield status /status not used not used pwm_a /pwm_a pwm_b /pwm_b pwm_c /pwm_c not used la /la shield shield shield lb /lb not used not used
Indicates twisted pairs
For connection to the 9/230 8520 Digital CNC refer to cable C18
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Honda MR-20LF (has sockets) 8520-H20F
Belden 9508 or Belden 9808
Honda MR-25LF (has sockets) 8520-H25F
25m (82 ft)
Page 385
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C21
9/230, 9/260, 9/290 8520 Digital
8520 Digital Servo Amplifier
8520 Digital Servo Amp. Power Source Cable (230V ac)
External ac Power Source
Prepared by Customer
------
N/A on the 9/230
-----------------------
----------------------
--------------------
-----------------
1
2
3 4
5 TB1
1f 200v/230v - 2 1f 200v/230v - 1
3f200v/230v - f3 3f200v/230v - f2 3f200v/230v - f1
C21
From fuses and/or contactors provided by customer
11217-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Per Local Codes
Miscellaneous
Line Drop Limitation
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C22
9/260 and 9/290
8520 3- Axis Digital Servo Module (CN08F)
Analog Spindle Signal Cable
Analog Out Port
Prepared by Customer
1 2 3 4 5 6 7 8
N.C. N.C. N.C.
Analog signal + 10 V Analog signal ground Shield
N.C. N.C.
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Honda MR-8LM (has pins) 8520-H8M
Belden 9501
Miscellaneous
Line Drop Limitation
7A-37
Page 386
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C23
9/260 and 9/290
8520 3- Axis Digital Servo Module (CN09M)
Touch Probe Signal Cable
Touch Probe
Prepared by Customer
1 2 3 4 5 6 7 8
+5V dc touch probe power Touch Probe signal input Touch Probe signal ground
N.C. N.C.
Shield
N.C. N.C.
11218-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Honda MR-8LF (has sockets) 8520-H8F
Belden 9502
Miscellaneous
3 m (10 ft)
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C24
9/260 and 9/290
Digital Servo Module (CN10M)
Battery Backup Cable (dc)
Lithium Battery
Part of Battery Assembly
C25
All 9/Series
MTB Panel CN56F
RS- 232 Serial Interface Cable
I/O Device
Prepared by Customer
For cable wiring examples, refer to page 8-3. Also refer to the manual included with the I/O device being connected. Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
25- pin D-shell (has pins) 8520-D25M
Belden 9508
Miscellaneous
4
4 The maximum length of this cable depends on the length of cable C07. The combined length of cables C07 and C25 may not exceed 15 m (50 ft).
7A-38
Page 387
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C26
All 9/Series
MTB Panel Input Ribbon Cable
MTB Panel Output Cable
MTB Panel I/O Module CN51
Included with MTB Panel I/O Module
C27
All 9/Series
MTB Panel Output Ribbon Cable
MTB Panel Output Cable
MTB Panel I/O Module CN52
Included with MTB Panel I/O Module
C28
All 9/Series
Power Supply Connector BT02 on Operator Panel or Removable Operator Panel Interface Assembly
MTB Panel I/O Power Cable
MTB Panel I/O Module +12V, GND
Prepared by Customer
BT02 ac L1 ac L2 PE + 5V GND
+12V dc
+ 5V
GND
GND + 5V
C28
GND + 12V GND
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Belden 8719
Miscellaneous
5m (16 ft)
7A-39
Page 388
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C29
All 9/Series
Power Supply Connector BT02 on Operator Panel or Removable Operator Panel Interface Assembly
HPG Power Supply Cable
HPG BT23, +5V, GND
Prepared by Customer
+ 5V
GND
AC L1 AC L2
BT02
C29
BT23
PE + 5V GND + 5V GND + 5V GND + 12 V GND
7A-40
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Belden 8719
Miscellaneous
5m (16 ft)
Page 389
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C30
All 9/Series
High Density I/O CN61M, CN62M, CN63F
High Density Signal Cables
Miscellaneous I/O Devices (examples shown)
Prepared by Customer
CN61M or CN62M D1 or D34 D2 or D35 D3 or D36 D4 or D37
Typical Inputs
1 2 3 4 5
D5 or D38 D6 or D39 D8 or D41 D9 or D42 D10 or D43
6 7 8 9 10
D11 or D44
11
D33 or D66
33 34
D7 or D40 reserved reserved reserved
35 36 37 reserved
C30
Share current between these four +24V pins Lamp
CN63F D1
1
D2
2 3
D3 D4 D5
Typical Outputs
Relay
C30
4 5
Lamp
Relay D36
36 not used
37
N.C.
BT33 on High Density I/O Module Module power and Input Device Power
Customer- supplied Power supply for output device
Suppression circuit and preheat resistors are not shown here for clarity. Refer to page 7C-4 for details on suppression circuits.
Com
TB1
TB2 Com +24 V dc
Com PE
+24 V dc
We recommend that you connect the 24V common to the electrical cabinet PE BUS at the power supply output.
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
37- pin D-shells
Belden 9319
Miscellaneous
Line Drop Limitation
2 8520-D37F 1 8520-D37M Pins 34, 35, 36, and 37 are reserved for common points.
7A-41
Page 390
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C31
All 9/Series
High Density I/O BT33
High Density I/O Power Source Cable (24V dc)
External dc Power Source
Prepared by Customer
Module power supply
Power supply for output device
BT33 on High Density I/O Module +24 V dc
Com
Com +24 V dc
We recommend you connect the 24V common to the electrical cabinet ground BUS at the power supply output.
C31
To electrical cabinet ground BUS 14AWG
7A-42
+24 V dc Common Customer 24V dc power supply or from PS2 on the 9/230
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Belden 9411
Miscellaneous
Line Drop Limitation