The text of a manual · part 40 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 391 to 400
Pages 391 to 400 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 391
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C32
All 9/Series
Digital I/O BT31, BT32
Digital I/O Signal Cable
Miscellaneous I/O Devices (examples shown)
Prepared by Customer
Typical Inputs
Customer power supply
Terminal Block COM COM A01
A02
COM COM B01
A11
A03
B02
V ac V ac
A04
B03
A12
A05
A06
B04
B05
A13
A14
A07
B06
A08
B07
A15
A09
B08
A16
A10 COM
B09
B10
NOT USED
Suppression circuit and pre-heat resistors are not shown here for clarity. Refer to page 7C-4 for details on suppression circuits.
Label
COM
B11
V ac V ac
B12
B13
B14
B15
NOT USED
B16
Customer power supply
Example using type E153 Motor
Typical Outputs
Noise suppress or Lamp Lamp
Customer power supply
Relay
11223-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Per Local Codes
Miscellaneous
Line Drop Limitation
7A-43
Page 392
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C33
All 9/Series
Digital I/O BT31
Digital I/O Power Source Cable (115/230V ac, 24V dc)
External ac/dc Power Source
Prepared by Customer
C33
115 V ac connection
Ground ac power, 115 V ac neutral ac power, 115 V ac
C33
230 V ac connection ac power, 230 V ac neutral Ground ac power, 230V ac
Terminal Block
Terminal Block
CHASSIS GND 230V ac NEUT
NOT USED
115V ac NEUT
Label
115/230 V ac
CHASSIS GND 230V ac NEUT
115V ac NEUT
NOT USED
Label
115/230 V ac
C33
24 V dc connection
Ground dc power, 24V dc common dc power, +24V dc
Terminal Block
CHASSIS GND NOT USED
7A-44
NOT USED
24V dc COM
+24 V dc
Label 11224-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Per Local Codes
Miscellaneous
Line Drop Limitation
Page 393
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C34
All 9/Series
E-Series Analog I/O
Analog I/O Signal Cable
Miscellaneous Analog Devices
Prepared by Customer
Shield wire, no connection at device end (com) C34
0 to +10V dc from analog device (+)
Single Input
Shield wire, no connection at device end
Differential Input
(-) C34
- 10 to 0V dc from analog device
Terminal Block
PE NOT USED
INPUT COM INPUT PE (-) (+) NOT PE PE PE PE USED
(com)
INPUT (-)
PE
Label NOT USED
PE
COM PE
INPUT (+) PE
0 to +10V dc from analog device
PE PE
NOT USED
(+)
Shield wire, no connection at device end
Output
(com) C34 0 to +10V dc or - 10 to +10V dc to analog device Terminal Block
PE NOT USED
COM PE
OUTPE NOT PUT USED NOT PE NOT PE USED USED
(+)
Label
PE = Protective Earth
11225-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Belden 9501 or 9502
Miscellaneous
Line Drop Limitation
7A-45
Page 394
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C35
All 9/Series
E-Series Analog I/O
Analog I/O Power Source Cable (115/230V ac)
External ac Power Source
Prepared by Customer
Ground
C35
115 V ac connection ac power, 115 V ac neutral ac power, 115V ac
C35
230 V ac connection ac power, 230 V ac neutral Ground ac power, 230V ac
Terminal Block
CHASSIS GND 230V ac NEUT
7A-46
NOT USED
115V ac NEUT
Label 115/230 V ac
Terminal Block
CHASSIS GND 230V ac NEUT
NOT USED
115V ac NEUT
Label 115/230 V ac
11226-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Per Local Codes
Miscellaneous
Line Drop Limitation
Page 395
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C36
9/230, 9/260, and 9/290
3-axis Analog Servo Module or Processor Board J1, J2, and J3
Encoder and Analog Drive Signal Cable
1771-HTE Enc. Termination Panel AXIS terminal
Purchased from Allen-Bradley 8500-TPC
1
19
Servo Mod.
9
C36
SHLD_CHA CHB_HI CHB_LO SHLD_CHB CHZ_HI CHZ_LO SHLD_CHZ +5_ENC SIGNAL COMM SHLD_+5V SW_5V_ENC SIGNAL COMM SHLD_SEN DRIVE DRIVE.RET SHLD_DRV +5V_ENC
À +15V_ENC
19
9
26
Term Panel
26 Not Used Not Used Not Used Not Used Not Used Not Used CHA_HI CHA_LO
1
1 10 19 2 11 20 3 12 21 4 13 22 5
1 10 19 2 11 20 3 12 21 4 13 22 5
14 23
14 23
7 16
7 16
24 8 17 25 9 18 26
24 8 17 25 9 18 26
6 15
6 15
Not Used Not Used Not Used Not Used Not Used Not Used CHA_HI CHA_LO SHLD_CHA CHB_HI CHB_LO SHLD_CHB CHZ_HI CHZ_LO SHLD_CHZ +5_ENC SIGNAL COMM SHLD_+5V SW_5V_ENC SIGNAL COMM SHLD_SEN DRIVE DRIVE.RET SHLD_DRV +5V_ENC À+15V_ENC
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
26- pin D-shell (has pins)
8500-TP (A-B part number)
26- pin D-shell (has pins)
120 inch +5.5”or -1.5”
11227-I
À This pin is not connected on the 9/230 CNC
7A-47
Page 396
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C37
9/230, 9/260, and 9/290
1771-HTE Enc. Termination Panel DRIVE terminal
Analog Servo Amplifier Signal Cable
Analog Servo Amplifier
Prepared by Customer or purchase with AB-Drives
Shield wire, no connection at amplifier end.
DRIVE DRIVE RET
C37
Term Panel
SHLD
Analog Drive Amplifier (Refer to appendix D for connection to AB drives)
The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft.
EXT. POWER EXT PWR IN EXT RET IN To Electrical Cabinet PE Bus. 14 Guage. Repeat for each axis term panel.
7A-48
11228-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length none
Belden 9501
Miscellaneous
25 m (82 ft) (measured from TERM panel)
Page 397
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C38
1771-HTE Enc. Termination Panel ENCODER terminal
Analog Servo Feedback Encoder Cable
A-B 845H Optical Encoder
Prepared by Customer or purchase with AB-Drives
ENCODER
C38
A
CH A. HI
A
Term Panel
CH A. LO
B
CH B. HI
B
CH B. LO
A
H
A B B Z Z + Return Ground
I
1
AB SHLD
A
B
1
C
Z SHLD
Z
CH Z. HI
Z
CH Z. LO
J D F G
A-B 845H Optical Encoder
1 To comply with the 9/Series encoder timing, the 845H B high terminal must be connected to the 9/Series B low terminal, and the 845H B low terminal must be connected to the 9/Series B high terminal. For the 9/Series encoder timing diagram refer to the description of parameter Position Feedback Type in your AMP reference manual.
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length none
Belden 9730
Miscellaneous
25 m (82 ft) (measured from TERM panel)
7A-49
Page 398
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C39
9/230, 9/260, and 9/290
1771-HTE Enc. Termination Panel ENC POWER terminal
Analog Servo Encoder Power Cable
A-B 845H Optical Encoder
Prepared by Customer or purchase with AB-Drives
Note 1: Be aware that this connection is dependent on the necessary encoder voltage. If 5V dc encoders are used connect this wire as shown below. If a 15V dc encoder is used, connect this wire to the terminal labeled +15. If a different encoder power supply is used, you must connect your encoder as discussed on page 4C-26. Note that if the +5V connection is made, the power supply connection to connector P3 on the analog servo module must be made.
A H I
Motor Mounted Encoder C39
ENC POWER
C
A-B 845H Optical Encoder
J Note 1
+5V
Term Panel
B
D
RET
F
+15V
G
EX PWR OUT
Connect G to Motor Frame or Drive PE Stud.
SHLD
A H
Non-Motor Mounted Encoder
I B
C39
ENC POWER
J Note 1
+5V
Term Panel
C
A-B 845H Optical Encoder
D F
RET
G
+15V
Connect G to Shield.
EX PWR OUT SHLD
7A-50
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length none
Belden 8719
Miscellaneous
25 m (82 ft)
Page 399
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C40
9/230, 9/260, and 9/290
Analog Servo Amplifier
Analog Servo Drive Signal Cable
Servo Motor
Prepared by Customer
Refer to Appendix D for A-B drives or refer to drives manual for details. Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C41
9/260, and 9/290
Analog Servo Module BAT/TP (TB1)
Touch Probe Cable
Touch Probe
Prepared by Customer
C41 TB1
6
Shield Probe Common
5
Probe fired signal
4
+5 V dc probe power
3
Touch probe control unit
2 1 11231-I
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
None
Belden 9502
Miscellaneous
3 m (10 ft)
7A-51
Page 400
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C42
9/260, and 9/290
Analog Servo Module ANALOG OUT (TB2)
Analog Servo Module Drive Signal Cable
Analog Drive Spindle Drive Amplifier
Prepared by Customer
C42
9/230
Processor Board ANALOG OUT (TB3)
C42
9/440 (all)
Wiring Board ANALOG OUT (TB2 and TB3) TB2 9/260 and 9/290
TB3 9/230
C42 3
Shield Signal common
2
+ 10V analog signal
Spindle drive
1
3
Shield
2
Signal common
1
+ 10V analog signal Connect to PE
TB2 and TB3 9/440 Wiring Board
6
SHLD
5
ANLGOUT2 + 10V analog signal
4
RET
3
SHLD
2
ANLGOUT1 + 10V analog signal
1
RET
TB3
TB2
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
None
Belden 9501
Miscellaneous
3 m (10 ft)
Refer to the drives manual provided with your Spindle Drive Amplifier for details.
7A-52