Page 391

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C32

All 9/Series

Digital I/O BT31, BT32

Digital I/O Signal Cable

Miscellaneous I/O Devices (examples shown)

Prepared by Customer

Typical Inputs

Customer power supply

Terminal Block COM COM A01

A02

COM COM B01

A11

A03

B02

V ac V ac

A04

B03

A12

A05

A06

B04

B05

A13

A14

A07

B06

A08

B07

A15

A09

B08

A16

A10 COM

B09

B10

NOT USED

Suppression circuit and pre-heat resistors are not shown here for clarity. Refer to page 7C-4 for details on suppression circuits.

Label

COM

B11

V ac V ac

B12

B13

B14

B15

NOT USED

B16

Customer power supply

Example using type E153 Motor

Typical Outputs

Noise suppress or Lamp Lamp

Customer power supply

Relay

11223-I

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Per Local Codes

Miscellaneous

Line Drop Limitation

7A-43

Page 392

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C33

All 9/Series

Digital I/O BT31

Digital I/O Power Source Cable (115/230V ac, 24V dc)

External ac/dc Power Source

Prepared by Customer

C33

115 V ac connection

Ground ac power, 115 V ac neutral ac power, 115 V ac

C33

230 V ac connection ac power, 230 V ac neutral Ground ac power, 230V ac

Terminal Block

Terminal Block

CHASSIS GND 230V ac NEUT

NOT USED

115V ac NEUT

Label

115/230 V ac

CHASSIS GND 230V ac NEUT

115V ac NEUT

NOT USED

Label

115/230 V ac

C33

24 V dc connection

Ground dc power, 24V dc common dc power, +24V dc

Terminal Block

CHASSIS GND NOT USED

7A-44

NOT USED

24V dc COM

+24 V dc

Label 11224-I

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Per Local Codes

Miscellaneous

Line Drop Limitation

Page 393

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C34

All 9/Series

E-Series Analog I/O

Analog I/O Signal Cable

Miscellaneous Analog Devices

Prepared by Customer

Shield wire, no connection at device end (com) C34

0 to +10V dc from analog device (+)

Single Input

Shield wire, no connection at device end

Differential Input

(-) C34

- 10 to 0V dc from analog device

Terminal Block

PE NOT USED

INPUT COM INPUT PE (-) (+) NOT PE PE PE PE USED

(com)

INPUT (-)

PE

Label NOT USED

PE

COM PE

INPUT (+) PE

0 to +10V dc from analog device

PE PE

NOT USED

(+)

Shield wire, no connection at device end

Output

(com) C34 0 to +10V dc or - 10 to +10V dc to analog device Terminal Block

PE NOT USED

COM PE

OUTPE NOT PUT USED NOT PE NOT PE USED USED

(+)

Label

PE = Protective Earth

11225-I

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Belden 9501 or 9502

Miscellaneous

Line Drop Limitation

7A-45

Page 394

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C35

All 9/Series

E-Series Analog I/O

Analog I/O Power Source Cable (115/230V ac)

External ac Power Source

Prepared by Customer

Ground

C35

115 V ac connection ac power, 115 V ac neutral ac power, 115V ac

C35

230 V ac connection ac power, 230 V ac neutral Ground ac power, 230V ac

Terminal Block

CHASSIS GND 230V ac NEUT

7A-46

NOT USED

115V ac NEUT

Label 115/230 V ac

Terminal Block

CHASSIS GND 230V ac NEUT

NOT USED

115V ac NEUT

Label 115/230 V ac

11226-I

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

Per Local Codes

Miscellaneous

Line Drop Limitation

Page 395

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C36

9/230, 9/260, and 9/290

3-axis Analog Servo Module or Processor Board J1, J2, and J3

Encoder and Analog Drive Signal Cable

1771-HTE Enc. Termination Panel AXIS terminal

Purchased from Allen-Bradley 8500-TPC

1

19

Servo Mod.

9

C36

SHLD_CHA CHB_HI CHB_LO SHLD_CHB CHZ_HI CHZ_LO SHLD_CHZ +5_ENC SIGNAL COMM SHLD_+5V SW_5V_ENC SIGNAL COMM SHLD_SEN DRIVE DRIVE.RET SHLD_DRV +5V_ENC

À +15V_ENC

19

9

26

Term Panel

26 Not Used Not Used Not Used Not Used Not Used Not Used CHA_HI CHA_LO

1

1 10 19 2 11 20 3 12 21 4 13 22 5

1 10 19 2 11 20 3 12 21 4 13 22 5

14 23

14 23

7 16

7 16

24 8 17 25 9 18 26

24 8 17 25 9 18 26

6 15

6 15

Not Used Not Used Not Used Not Used Not Used Not Used CHA_HI CHA_LO SHLD_CHA CHB_HI CHB_LO SHLD_CHB CHZ_HI CHZ_LO SHLD_CHZ +5_ENC SIGNAL COMM SHLD_+5V SW_5V_ENC SIGNAL COMM SHLD_SEN DRIVE DRIVE.RET SHLD_DRV +5V_ENC À+15V_ENC

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

26- pin D-shell (has pins)

8500-TP (A-B part number)

26- pin D-shell (has pins)

120 inch +5.5”or -1.5”

11227-I

À This pin is not connected on the 9/230 CNC

7A-47

Page 396

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C37

9/230, 9/260, and 9/290

1771-HTE Enc. Termination Panel DRIVE terminal

Analog Servo Amplifier Signal Cable

Analog Servo Amplifier

Prepared by Customer or purchase with AB-Drives

Shield wire, no connection at amplifier end.

DRIVE DRIVE RET

C37

Term Panel

SHLD

Analog Drive Amplifier (Refer to appendix D for connection to AB drives)

The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft.

EXT. POWER EXT PWR IN EXT RET IN To Electrical Cabinet PE Bus. 14 Guage. Repeat for each axis term panel.

7A-48

11228-I

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length none

Belden 9501

Miscellaneous

25 m (82 ft) (measured from TERM panel)

Page 397

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C38

1771-HTE Enc. Termination Panel ENCODER terminal

Analog Servo Feedback Encoder Cable

A-B 845H Optical Encoder

Prepared by Customer or purchase with AB-Drives

ENCODER

C38

A

CH A. HI

A

Term Panel

CH A. LO

B

CH B. HI

B

CH B. LO

A

H

A B B Z Z + Return Ground

I

1

AB SHLD

A

B

1

C

Z SHLD

Z

CH Z. HI

Z

CH Z. LO

J D F G

A-B 845H Optical Encoder

1 To comply with the 9/Series encoder timing, the 845H B high terminal must be connected to the 9/Series B low terminal, and the 845H B low terminal must be connected to the 9/Series B high terminal. For the 9/Series encoder timing diagram refer to the description of parameter Position Feedback Type in your AMP reference manual.

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length none

Belden 9730

Miscellaneous

25 m (82 ft) (measured from TERM panel)

7A-49

Page 398

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C39

9/230, 9/260, and 9/290

1771-HTE Enc. Termination Panel ENC POWER terminal

Analog Servo Encoder Power Cable

A-B 845H Optical Encoder

Prepared by Customer or purchase with AB-Drives

Note 1: Be aware that this connection is dependent on the necessary encoder voltage. If 5V dc encoders are used connect this wire as shown below. If a 15V dc encoder is used, connect this wire to the terminal labeled +15. If a different encoder power supply is used, you must connect your encoder as discussed on page 4C-26. Note that if the +5V connection is made, the power supply connection to connector P3 on the analog servo module must be made.

A H I

Motor Mounted Encoder C39

ENC POWER

C

A-B 845H Optical Encoder

J Note 1

+5V

Term Panel

B

D

RET

F

+15V

G

EX PWR OUT

Connect G to Motor Frame or Drive PE Stud.

SHLD

A H

Non-Motor Mounted Encoder

I B

C39

ENC POWER

J Note 1

+5V

Term Panel

C

A-B 845H Optical Encoder

D F

RET

G

+15V

Connect G to Shield.

EX PWR OUT SHLD

7A-50

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length none

Belden 8719

Miscellaneous

25 m (82 ft)

Page 399

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C40

9/230, 9/260, and 9/290

Analog Servo Amplifier

Analog Servo Drive Signal Cable

Servo Motor

Prepared by Customer

Refer to Appendix D for A-B drives or refer to drives manual for details. Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C41

9/260, and 9/290

Analog Servo Module BAT/TP (TB1)

Touch Probe Cable

Touch Probe

Prepared by Customer

C41 TB1

6

Shield Probe Common

5

Probe fired signal

4

+5 V dc probe power

3

Touch probe control unit

2 1 11231-I

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

None

Belden 9502

Miscellaneous

3 m (10 ft)

7A-51

Page 400

Section 7A Connecting Components

Table 7A.A Cable and Connector List (continued) Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C42

9/260, and 9/290

Analog Servo Module ANALOG OUT (TB2)

Analog Servo Module Drive Signal Cable

Analog Drive Spindle Drive Amplifier

Prepared by Customer

C42

9/230

Processor Board ANALOG OUT (TB3)

C42

9/440 (all)

Wiring Board ANALOG OUT (TB2 and TB3) TB2 9/260 and 9/290

TB3 9/230

C42 3

Shield Signal common

2

+ 10V analog signal

Spindle drive

1

3

Shield

2

Signal common

1

+ 10V analog signal Connect to PE

TB2 and TB3 9/440 Wiring Board

6

SHLD

5

ANLGOUT2 + 10V analog signal

4

RET

3

SHLD

2

ANLGOUT1 + 10V analog signal

1

RET

TB3

TB2

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

None

Belden 9501

Miscellaneous

3 m (10 ft)

Refer to the drives manual provided with your Spindle Drive Amplifier for details.

7A-52