The text of a manual · part 41 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 401 to 410
Pages 401 to 410 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 401
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C43
9/260 and 9/290
Optional Feedback Module (CN24M)
+5V dc Encoder Power Supply Cable
8520 3 Axis Digital Servo Module (CN13)
Included with Optional Feedback Module
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C44
9/260 and 9/290
Optional Feedback Module (CN14F, CN15F, CN16F)
Non-motor Mounted Feedback Device Feedback Cable
Non-motor Mounted Feedback Device
Prepared by Customer
PB PB ENC_15V ENC_15V Shield
C44
1 2 3
For 15V Feedback Devices
4 5 6
PZ PZ PA PA SIGNAL COMM SIGNAL COMM SIGNAL COMM ENC_5V ENC_5V ENC_5V
7 8 9 10 11
Feedback Device Signal Common
12 13 14
For 5V Feedback Devices
15 16
Indicates twisted pairs
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Honda MR-16LM (has pins) 8520-H16M
Belden 8308 5
Miscellaneous
25m (82 ft)
5 This cable has 22 AWG twisted pairs. Multiple lines (4) must be used to provide sufficient power to the feedback device. Instructions are provided in the connector kit.
7A-53
Page 402
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C45
9/440HR
9/440HR System Module Feedback Board
9/440HR 1326 Motor- mounted HIPERFACE Feedback Cable
9/440HR 1326 Motor- mounted HIPERFACE
Purchased with System (1326-CCU-xxx)
Supply Power
White Black Red
Supply GND 2 CHA_LO 11 CHA_HI 12
Clear
Wire Pair Shield 10
Black Blue Clear
CHB_LO CHB_HI Wire Pair Shield
Black Green Clear Green/Yellow
A B C D
3
Black
8 9 7 RS485_HI 6 RS485_LO 5 Wire Pair Shield 4 Overall Shield 1
E F G H I J Ferrite Suppressor Core
7A-54
Page 403
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C46
9/230
Processor Board TP (TB2)
Touch Probe Cable
Touch Probe
Prepared by Customer
9/440 (all)
System Module Wiring Board (TB5) TB5 9/440 TB2 9/230 1
4 SHLD
1
PE
2
TPIN
3
+5V
4
+5 V dc probe power Probe fired signal +5V common Shield
Touch probe control unit
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
None
Belden 9502
Miscellaneous
3 m (10 ft)
7A-55
Page 404
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C47
9/Series 1394 Digital
9/230 Servo Connector (J1, J2, or J3)
1394 CNC Interface Cable
1394 System Module
8520-DSC
44- pin D-shell (to CNC)
7A-56 shield chu_hi chu_lo chv_hi chv_lo chw_hi chw_lo cha_hi cha_lo chb_hi chb_lo chz_hi chz_lo VA return VB
1 2 32 3 33 4 34 11 41 10 40 39 9 5 43 35 status /status enable gnd gnd gnd not used /enable gnd
8 38 13 15 19 28 29 31 16
Shield wire, no connection at 1394 drive end.
Indicates twisted pair
2 u high 11 u low 3 v high 12 v low 4 w high 13 w low 5 a high 14 a low 6 b high 26- pin D-shell 15 b low (to 1394 System Module) z high 7 16 z low 20 IA 21 I ret 22 IB 23 I ret 8 status_o 17 status_l (gnd) 9 axis enable request 10 signal common 19 signal common 24 signal common 25 signal common 26 signal common 18 gnd 24v input return
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
44- pin Miniature D-shell (has pins) 8520-MD44M
AB 8520-DSC
26 pin Miniature D-shell (has pins) 8520-MD26M
25m (82 ft) (8520-DSC comes 27 inches standard)
Page 405
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C48
1394 Digital Amplifier or 9/440 Resolverbased
1394 CNC System Module
1394 Resolver Interface Cable. (note this cable requires 360°shielding for CE compliance. See page 17-9 in this manual.)
1326 Motor- mounted Resolver
Purchased with System (1326-CCU-xxx)
R1 R2 Shield S1 C1
1 6 2 3 8
A B D E
Shield C2
7 9 S2 4 Shield 5 Shield 10
H G Ferrite Suppressor Core
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C49
1394 Digital Amplifier or 9/440 (all)
1394 Axis Module
1394 Motor Interface Cable (note this cable requires 360° shielding for CE compliance. See page 17-9 in this manual.)
1326 Motor
Purchased with System (1326-CPB1xxx)
4
3 2 1 TB1
Cabinet Ground Bar
C49 Shield
For 1326-CPB1xxx
Shield
Motor Connector 9 5 4
PE1
6
PE2 PE3
8
W1
3
7
V1
2
U1
1
7A-57
Page 406
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C50
9/260, 9/290
4-axis 1394/Analog Servo Module (8520-SM4)
1394 CNC Interface Cable
1394 System Module
Customer Supplied
44- pin D-shell (to CNC)
7A-58 shield not used not used not used not used not used not used cha_hi cha_lo chb_hi chb_lo chz_hi chz_lo VA return not used
1 2 32 3 33 4 34 11 41 10 40 39 9 5 43 35 status /status not used gnd gnd gnd not used not used gnd
8 38 13 15 19 28 29 31 16
Shield wire, no connection at 1394 drive end.
Indicates twisted pair
2 u high 11 u low 3 v high 12 v low 4 w high 13 w low 5 a high 14 a low 6 b high 15 b low 26- pin D-shell 7 z high (to 1394 System Module) 16 z low 20 IA 21 I ret 22 IB 23 I ret 8 status_o 17 status_l (gnd) 9 axis enable request 10 signal common 19 signal common 24 signal common 25 signal common 26 signal common 18 gnd 24v input return
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
44- pin Miniature D-shell (has pins) 8520-MD44M
Belden 9515
26- pin Miniature D-shell (has pins) 8520-MD26M
25m (82 ft)
Page 407
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C51
9/260, and 9/290
4-axis 1394/Analog Servo Module (8520-SM4)
Encoder and Analog Drive Signal Cable
1771-HTE Enc. Termination Panel AXIS terminal
Customer Supplied
1
31
C51
Servo Mod. 15
Shield CHB_HI CHB_LO Shield
1 11 41 30 10 40 30
CHZ_HI CHZ_LO Shield
39 9 30
+5_ENC SIGNAL COMM +5_ENC SIGNAL COMM
24 16 25 19
DRIVE DRIVE.RET Shield
5 43
+5V_ENC SIGNAL COMM +5V_ENC SIGNAL COMM +15V_ENC SIGNAL COMM
19
9
26
Term Panel
44 Shield* CHA_HI CHA_LO
1
1 3 12 21 4 13 22 5
* Use one of the unused drain wires from a twisted pair for the pin one to pin one connection.
14 23 7 16 6 17 9 18 26
1 20 15 21 29
7 17 6 17
17 28
15 16
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
44- pin D-shell (has pins)
Belden 8774
26- pin D-shell (has pins)
120 in. +5.5 or -1.5 in.
7A-59
Page 408
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C52
9/440 Resolverbased
9/440 Resolver- based System Module Feedback Board
Encoder Signal Cable
AB 845H Encoder
Customer Supplied
2 8 1 7 3 9
12 6 Use four 22 gauge twisted pair to make the power connections to pins 6 and 12. Strip 1 inch of one lead and solder into pin. Solder the three remaining leads to the exposed one inch of wire to make the equivalent of 16 gauge wire. Use the appropriate wire tape. Repeat for both pins.
A H I B C J D F
5 11 12 6
AB 845H Encoder
16 AWG for encoder power pins 6 and 12 (use four 22 gauge)
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
AMP 770581- 1
Belden 8307
MS Type
25 m (82 ft.)
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C53
9/440 (all)
On/Off Power Control Module
115V Transformer Feed
24V Logic Transformer (customer supplied)
Prepared by Customer
On/Off Power Control Module L1 ac IN L2
C53
Customer supplied 24V logic transformer High
PE
Low
L1 AUX ac
L2
ON SW
To local cabinet PE bus
COMMON OFF SW
Important: Make sure 24V logic power is applied before allowing 3- phase power to come up. Logic power must be applied to the system module first.
7A-60
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Belden 9409
Miscellaneous
Line Drop Limitation
Page 409
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C54
9/440 (all)
24V Logic Transformer (customer supplied)
24V Logic Power
9/440 System Module Power Terminal Block
Prepared by Customer
9/440 System Module Power Terminal Block
Important: Make sure 24V logic power is applied before allowing 3 phase power to come up. Logic power must be applied to the system module first.
Customer supplied 24V logic transformer High
15 AMP Customer Supplied Fuses dc+
C54
INT
COL W1(+)
U
V
W
W2(--) PE
Low
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Belden 9409
Clamped by terminal screws
Line Drop Limitation
7A-61
Page 410
Section 7A Connecting Components
Table 7A.A Cable and Connector List (continued) Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C55
9/440 (all)
External 380/460V Three Phase
Drive Power
9/440 System Module Power Terminal Block
Prepared by Customer
9/440 Power Strip
Bussman FRS- R- 20A (class RK-5) 600 V ac (qty. 3)
dc+
INT
COL
W1
W2
U
C55
V
W PE
Three-phase input 380-460V ac ac Bulletin 100- A30N x 3 (surge protector required) or dc Bulletin 100- A30NZ x 3 Bulletin 100 Contactor Power
Noise suppressor
E-Stop Status Contactor (customer supplied or internal 9/440 TB1 status)
!
7A-62
ATTENTION: Brake control should not be directly released by the E-Stop status relay (or your customer supplied E-Stop control relay). Brakes should only be released by the PAL logic when it has determined that the 9/440 is in full control of the servo motors and the control is out of E-Stop. See the description of the PAL flag $PFLT.15 for detail on how to test drive status.
Connector On End of Cable
Cable Type
Connector on End of Cable
Max. Cable Length
Miscellaneous
See Local Codes (12Awg max)
Clamped by terminal screws
Line Drop Limitation