The text of a manual · part 5 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 41 to 50
Pages 41 to 50 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 41
Section 1B System Overview
Figure 1B.18 1746 I/O Ring Adapter - 8500-1746I
1B.8 Communication Interface
Page 8-1 covers the peripherals that can be interfaced to the control. These peripherals are used to input or output data to the control. This data can be in the form of part programs, AMP, PAL and others. The data is input to the control through Port A or Port B, for Series 9/260 and 9/290, or only Port B for 9/230.
1B.9 Offline Development System (ODS)
The Offline Development System (ODS) is a menu driven software package that resides on your personal computer. You can use ODS to:
1B.10 Adjustable Machine Parameters (AMP)
The system installer uses AMP and PAL to integrate the control to the machine. Through AMP, the system installer can:
create and edit part program files download AMP and PAL files to the control create, edit and document AMP and PAL files upload, copy, restore, rename, or delete files define a number of basic parameters such as system resolution, axis types, that affect the overall operation of the control. define a number of individual axis parameters such as soft travel limits, position tolerances, feedback constants. Refer to the 9/Series 9/230, 9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more information.
1B-15
Page 42
Section 1B System Overview
1B.11 Programmable Application Logic (PAL)
The system installer uses AMP and PAL to integrate the control to the machine. The system installer uses PAL to form a ladder logic program that is continuously executed by the control to control devices such as tool turrets, limit switches, coolant systems, and lamps. PAL also controls the I/O process between the control and the machine tool. Through PAL, system variables, which are assigned to each input or output terminal of an I/O device, are monitored. PAL uses these variables to provide system control. Refer to the 9/Series CNC 9/230, 9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information.
1B.12 Fiber Optic I/O Ring
9/Series I/O devices are linked together by a fiber optic I/O ring. This I/O ring provides serial communication with the control. Inputs to the control are first converted to fiber optic signals at the I/O device. These signals are transmitted through the fiber optic I/O ring to the control. There they are converted back to electrical signals that can be monitored and acted on by the PAL program. Outputs from the control originate from the continuously executing PAL program which is stored in the control’s memory. They are converted to fiber optic signals at the control and transmitted through the fiber optic I/O ring to the appropriate I/O device. There they are converted back to electrical signals which cause the desired action.
END OF SECTION
1B-16
Page 43
9/Series, PAL, PLC, SLC 5/03, SLC 5/04, DH+, and INTERCHANGE are trademarks of Allen-Bradley Company, Inc.
Allen-Bradley, a Rockwell Automation Business, has been helping its customers improve productivity and quality for more than 90 years. We design, manufacture and support a broad range of automation products worldwide. They include logic processors, power and motion control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the world’s leading technology companies.
Worldwide representation. Argentina ·Australia ·Austria ·Bahrain ·Belgium ·Brazil ·Bulgaria ·Canada ·Chile ·China, PRC ·Colombia ·Costa Rica ·Croatia ·Cyprus ·Czech Republic · Denmark ·Ecuador ·Egypt ·El Salvador ·Finland ·France ·Germany ·Greece ·Guatemala ·Honduras ·Hong Kong ·Hungary ·Iceland ·India ·Indonesia · Ireland ·Israel ·Italy ·Jamaica ·Japan ·Jordan ·Korea ·Kuwait ·Lebanon ·Malaysia ·Mexico ·Netherlands ·New Zealand ·Norway ·Pakistan ·Peru · Philippines ·Poland ·Portugal ·Puerto Rico ·Qatar ·Romania ·Russia- CIS ·Saudi Arabia ·Singapore ·Slovakia ·Slovenia ·South Africa, Republic ·Spain · Sweden ·Switzerland ·Taiwan ·Thailand ·Turkey ·United Arab Emirates ·United Kingdom ·United States ·Uruguay ·Venezuela ·Yugoslavia
Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444
Publication 8520-6.2.1 - February 1996
PN160474 Copyright8520-6.2.1 1996 Allen-Bradley Company, 1996 Inc. Printed in USA Publication - February
Page 44
9/Series Hardware TAB 2
System Layout and Dimensions
80 Æ
46 max. (1.81)
(3.15”) 60 Æ
Side
4 Æ x 15 long, three places, on 72 Æ bolt circle
(2.36”)
60 (j2.36)
Front mm (in) 28 (1.10) 48max. (1.89)
119 (4.69)
Bottom
50 (1.97)
I/O ring fault indicator Address switches
Fiber optic connectors +5 Vdc terminal Common terminal
8520-6.2.2 -- August 1998
PN--176437
Page 45
3
Page 46
Section
2A
Planning Your System Layout
2A.0 Section Overview
When planning the system layout of your control, take into consideration the restrictions and specifications covered in this section. Mechanical system design specifications necessary for cabinet design and construction are listed in the following sections: Table 2A.A To Plan your System Layout For Information on:
2A.1 Determining Cable Lengths
See Page
Determining Cable Lengths
2A-1
Meeting Environmental Conditions
2A-1
Designing the Cabinet for Its Environment
2A-3
Reducing Noise
2A-8
Installing the Components
2A-8
When you install the components, refer to page 7A-1 for electrical cable lengths, and page 7B-1 for fiber optic cable lengths. ATTENTION: The system installer should consult local and state regulations for additional installation requirements.
2A.2 Meeting Environmental Conditions
You must install the components inside a cabinet that satisfies the environmental conditions listed in Table 2A.A. All components must meet these conditions for you to successfully operate the control.
2A-1
Page 47
Section 2A Planning Your System Layout
Table 2A.A Environmental Conditions Condition
Range or Limit
Operating temperature
CPU Board and Servo Amplifiers: 0°C to 55°C (32°F to 131°F) except 9/440 0°C to 50°C (32°F to 122°F) 9/440 only Operator Panels (standard and removable): 0°C to 55°C (32°F to 131°F) 0°C to 45°C (32°F to 113°F) external ambient Operator Panels (flat): 0°C to 50°C (32°F to 122°F) 0°C to 40°C (32°F to 104°F) external ambient Operator Panels (pendant): 0°C to 55°C (32°F to 131°F) 0°C to 40°C (32°F to 104°F) external ambient 8500 Digital Servo Motors: 0°C to 40°C (32°F to 104°F)
Storage or Transport Temperature
CPU Board, Servo Motors, and Servo Amplifiers -30°C to 70°C (-40°F to 158°F) Operator Panel: -30°C to 65°C (-40°F to 131°F)
Maximum Temperature Change Rate
1.1°C/min. (1.80°F/min.)
Altitude
Above temperature based on operation at 1000m (3500 ft)
Atmosphere
Components placed in a protected enclosure with filtered air. Avoid placing components in areas where there is high concentration of dust, cutting oil, or organic solvents.
Relative Humidity
CPU Board and Operator Panel 5-95% (no condensation) 8500 Digital Servo Motors 20-80% (no condensation)
Vibrations (operating)
Max. 1.0 G (operator panel) Max. 2.5 G (all 9/Series controls except 9/440) Max. 1.0 G (9/440 CNC) Max. 2.5 G (E-150 Series I/O)
ATTENTION: Environmental conditions exceeding those shown above may cause component failure and/or unpredictable control operation.
2A-2
Page 48
Section 2A Planning Your System Layout
2A.3 Designing the Cabinet for your System’s Environment
When designing the cabinet, consider the environment in which the control operate. The degree of cabinet sealing and whether or not external air must be filtered before entering the cabinet will depend on the expected environmental conditions. Industrial environments frequently require the cabinet be airtight. If it is not airtight, outside air may bring contaminants into the cabinet. Dust will accumulate in high voltage areas on the operator panel. Coolant mist adhering to this dust may cause an insulation failure. ATTENTION: If the environmental conditions require an airtight cabinet, the cooling system cannot bring outside air into the cabinet. In this case, an air conditioner or heat exchanger may be required.
To make the cabinet airtight, place gaskets between the component mounting faces, service ports, doors, covers, and the cabinet. Figure 2A.1 is an installation example that shows gasket placement between the operator panel and the cabinet. Figure 2A.1 Gasket Placement Example
19437
2A-3
Page 49
Section 2A Planning Your System Layout
2A.4 Maintaining Cabinet Temperature
The components of the control, like all electronic devices, dissipate power in the form of heat. The components and all modules in the control cabinet must be continuously cooled to prevent overheating. ATTENTION: If the internal temperature of the control cabinet exceeds 55°C (131°F), irreparable damage may result to the control and its components within the enclosure and injury to personnel.
Since solid state electronic equipment is more reliable at lower operating temperatures, we recommend that the internal control cabinet temperature be kept as cool as possible, without going below 0°C (32°F).
Using Fans Install fans inside the cabinet to keep the modules cool by circulating air inside the enclosure as shown in Figure 2A.2. Do not blow the air directly on the modules as this may cause accumulation of foreign matter on or inside the module. As fan driven air circulates inside the control enclosure, it absorbs some of the heat dissipated by the control components. If this air circulation does not guarantee sufficient thermal exchange through the cabinet walls, then the air must be cooled before it comes in contact with the components again.
Using Air Conditioners or Heat Exchangers The approximate change in internal air temperature due to a heat exchanger or air conditioner is a function of dissipated power, vertical surface area, and air conditioner or heat exchanger rating. In calculating the change in internal air temperature, be sure to use only the exposed vertical surface areas of the enclosure; do not include the top or bottom of the enclosure in the calculation. Important: To help assure adequate internal air flow, do not mount any obstructions within 0.6 meters of the intake and exhaust ports of fans, heat exchangers or air conditioners.
2A-4
Page 50
Section 2A Planning Your System Layout
Figure 2A.2 Filtered Air Flow In A Fan Cooled Cabinet
Exhaust air
Cabinet temperature between 0°C and 55°C
Servo Amplifier
Filter
Cooling air
Regardless of air conditioner or heat exchanger rating, be sure its blowers and all other fans provide sufficient internal air flow.
Calculating the Temperature within the Cabinet If you have a cabinet that contains an Operator Panel, allow for an increase in ambient temperature of up to +5°C (10°F). If you have a cabinet that contains modules other than the Operator Panel, allow for an increase of up to +10°C (20°F). Temperature information needed when designing a cabinet is listed with the specifications for each module. Design the cabinet so that temperature rise inside the cabinet, caused by heat generation of the modules and other units mounted inside, will not exceed allowable maximums. Table 2A.B shows the heat generation wattages of each component or module. 2A-5