Page 501
Section 9A Operator Interface
Figure 9A.19 shows the input circuit diagram for the MTB I/O module. Figure 9A.19 MTB I/O Module Input Circuit Diagram Push-Button MTB Panel
Push-Button MTB Panel I/O Module
CMOS Input
Switch Common
Converted to Optic Signal
Common 3A AMP fuse
Operator Panel
Fiber optics
+12V + -
Common
DC power supply
11269-I
Output Specifications Table 9A.P lists the output specifications for the circuit that outputs the operation status to the push-button MTB panel. Table 9A.P MTB I/O Module Output Specifications Item
9A-34
Specifications
Remark
A-B MTB Panel
Custom MTB Panel
Number of Output Points
37
18
Modal Group Outputs
19
Non- I/O Outputs
Discrete Outputs
18
I/O Outputs
Output Type
Sink/Source
Totem Pole Driver Output
Output Voltage Range
9.3-13.2V dc
Output Current at ON
Less than 125mA
Output Voltage Drop at ON
Less than 1 V DC
Number of Common Points
22
Isolation
Non-Isolated type
Connection
60 Pin Flat Cable Connector (CN52)
Per Each Output Internally Connected to Power Supply Max. Length 1m
Page 502
Section 9A Operator Interface
Figure 9A.20 shows the output circuit diagram for the MTB I/O module. Figure 9A.20 MTB I/O Module Output Circuit Diagram
Push-Button MTB Panel I/O Module Push-Button MTB Panel Fiber optics
Output
Load Converted from optical to electrical signal
Common
+12V
Operator Panel
Common
DC power supply 11860-I
9A.4.1.2 MTB Panel I/O Module Fiber Optic Connection
Table 9A.Q shows the connectors used to make the fiber optic connections to the I/O ring. Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Table 9A.Q MTB I/O Module Fiber Optic Connectors Connector On Motherboard
Connected To
Remark
OP11 (RED)
Receiver on next module in I/O ring
Output
OP12 (BLACK)
Transmitter on previous module in I/O ring
Input
9A-35
Page 503
Section 9A Operator Interface
9A.4.1.3 MTB I/O Module Mode Setting
If you are using a custom MTB panel you need to set a jumper so that the I/O module can interface with the MTB panel. If you have an Allen-Bradley MTB panel, you don’t need to set this jumper because it is preset. Set the jumper as shown:
+12V DC GND
CN51
OP12 (in)
OP11 (out)
JPR1 JPR2
CN52
MTB Panel Type
Pins to cover with the shorting post
Custom
3 and 2
Allen-Bradley
1 and 2
PANEL JPR3 CUSTOM
9A.4.1.4 MTB I/O Module Node Address Setting
A-B
Each push-button MTB panel must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned to each push-button MTB panel I/O module in the I/O assignment file. The node address is selected by cutting the jumpers located on the push-button MTB panel I/O module. Figure 9A.21 shows the location of the jumpers. Figure 9A.21 MTB I/O Module Jumper Positions
+12V DC GND
CN51
OP12 (in)
OP11 (out)
JPR1 JPR2
CN52 I/O ring fault indicator
9A-36
3 2 1
Page 504
Section 9A Operator Interface
Set the node address by cutting the wire jumper(s) on the push-button MTB panel I/O module, according to Table 9A.R shown below. Table 9A.R MTB I/O Module Node Address Setting Node Address
Jumper
Hexidecimal
Binary
JP1
JP2
00
00
Short
Short
01
01
Short
Open
02
10
Open
Short
03
11
Open
Open
The node address may be any number between 00 and 03. You may have a total of 4 MTB panels on the Fiber Optic I/O ring. The same node address can be used for different types of modules, but may not be used more than once for a specific type of module.
9A.4.2 MTB Panel Connectors and Pin Assignments (Direct I/O version)
Figure 9A.22 shows the connectors used to connect the Direct I/O push-button MTB panel to your I/O system. The Direct I/O version of the MTB Panel provides for 51 inputs to and 38 outputs from the I/O system. These inputs and outputs provide machine control functions for the operator to affect the Machine logic (PAL) program. A separate I/O ring device must be used to interface this panel to the 9/Series control.
9A-37
Page 505
Section 9A Operator Interface
Figure 9A.22 Direct I/O MTB Panel Connectors Output conector CN2 Pin 1
Control ON lamp
Input conector CN1 operation selection
Pin 1
P1 CN 1
CN 2
1 2 3
MTBI
MTBD
Direct I/O MTB panel integration 1) Note the locations of pin number one (#1) of CN1 and CN2 . Although the pin #1 locations are the same with respect to the connector keying, the connectors are oriented differently. 2) The P1 jumper is used to set the operation of the “control on” Lamp. In the 1--2 position (MTBD) the lamp is controlled by the I/O system (on when 24V is applied to pin CN2--32). In the 2--3 position (MTBI) the lamp is on whenever 24V is applied to the panel.
Input Interface Connector Input signals from the direct I/O MTB panel are sent through input connector CN 1 . These signals are available for use by the I/O system by pins supplied with this panel. Table 9A.S shows the pin assignments and functions for input interface ribbon cable on the push-button MTB panel.
9A-38
Page 506
Section 9A Operator Interface
Table 9A.S Direct I/O MTB Panel Input connector ( CN 1 ) Pin Assignments Pin No.
Function
Pin No.
Function
1
+24 V
2
Cycle Stop
3
+24 V
4
Cycle Start
5
+24 V
6
Single Block
7
+24 V
8
+X
9
+24 V
10
+Y
11
+24 V
12
+Z
13
AUTO
14
+4
15
MDI
16
-X
17
MANUAL
18
-Y
19
INCR
20
-Z
21
CONT
22
-4
23
HAND
24
TRVRS
25
HOME
26
F5
27
X1
28
F6
29
X10
30
F1
31
X100
32
F2
33
X1000
34
F3
35
X10000
36
F4
37
Rapid Override F1
38
Feedrate Override “a”
39
Rapid Override 25
40
Feedrate Override “b”
41
Spindle Speed Override “d”
42
Feedrate Override “c”
43
Spindle Speed Override “c”
44
Feedrate Override “d”
45
Spindle Speed Override “b”
46
Not Used
47
Spindle Speed Override “a”
48
Not Used
49
Rapid Override 50
50
Not Used
51
Rapid Override 100
52
Power Off
53
CCW
54
On / Off Pushbutton Common
55
OFF
56
Power On
57
CW
58
E-stop
59
Reset
60
E-stop PB Common
Output Interface connector Output signals from the I/O system are sent to the Lamps on the Direct MTB panel via the output interface connector CN 2. Table 9A.T shows the pin assignments and functions for this connector. 9A-39
Page 507
Section 9A Operator Interface
Table 9A.T Direct I/O MTB Panel Output connector ( CN 2 ) Pin Assignments Pin No.
9A-40
Function
Pin No.
Function
1
Ground
2
Cycle Stop
3
Gnd
4
Cycle Start
5
Gnd
6
Single Block
7
Gnd
8
+X
9
Gnd
10
+Y
11
Gnd
12
+Z
13
Gnd
14
+4
15
Gnd
16
-X
17
F4
18
-Y
19
F3
20
-Z
21
F2
22
-4
23
F1
24
Trvrs
25
F6
26
F5
27
AUTO
28
Not Used
29
MDI
30
Not Used
31
MANUAL
32
MANUAL
33
Rapid override F1
34
Contro On (if P1 is set to 1- 2)
35
Rapid Override 25
36
Not Used
37
Rapid Override 50
38
Not Used
39
Rapid Override 100
40
Not Used
41
CCW
42
X1
43
OFF
44
X 10
45
CW
46
X 100
47
INCR
48
X 1000
49
CONT
50
X 10 000
51
HAND
52
GND
53
HOME
54
GND
55
GND
56
GND
57
GND
58
GND
59
GND
60
GND
Page 508
Section 9A Operator Interface
9A.5 HPG (Hand Pulse Generator)
The Hand Pulse Generator (HPG) is a hand wheel used for manual operation of the the control’s axes. The HPGs are generally used to jog axes into position. The operator panel power supply provides power for three Hand Pulse Generators. The HPG is composed of two parts, the HPG itself and the HPG interface board. The HPG interface board is used to interface the HPG with the fiber optic I/O ring. Fiber optic cables are connected to the optical receiver (black) and transmitter (red) on the HPG interface board. The fiber optic cables and connectors are supplied by the system installer. For more information on fiber optics refer to page 7B-1. Figure 9A.23 shows the HPG (Hand Pulse Generator). Figure 9A.23 HPG (Hand Pulse Generator)
Front
Side
Bottom
I/O Ring Fault Indicator DIP switch
Fiber optic connectors +5V dc terminal Common terminal
11271-I
9A-41
Page 509
Section 9A Operator Interface
9A.5.1 HPG Connectors
Figure 9A.24 shows the connectors and terminal block used to make connections to the HPG interface board. Figure 9A.24 HPG Interface Board Connectors and Terminal Block Rear
+5V dc GND OP13 OP14 (OUT) (IN) Optical connectors From Operator Panel power supply
Table 9A.U shows the power supply connections to the HPG interface board. Table 9A.U HPG Power Supply Connectors HPG Connector Terminal
Connected To
BT23
+5V
Operator Panel
GND
Power Supply
Mating Connector BT03
5V dc GND
Cable Number
Remark
C28
Input Output
Table 9A.V shows the connectors used to make the fiber optic connections to the I/O ring. Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Refer to page 7B-1 for additional information on fiber optic cables and connectors.
9A-42
Page 510
Section 9A Operator Interface
Table 9A.V HPG Fiber Optic Connectors
9A.5.2 HPG Power Requirements
Connector On Motherboard
Connected To
Remark
OP13 (RED)
Receiver on next module in I/O ring
Output
OP14 (BLACK)
Transmitter on previous module in I/O ring
Input
The HPGs require a +5V dc power supply. This is supplied from connector BT03 on the operator panel power supply. If the control uses more than three HPGs the system installer will have to provide an external power supply. Table 9A.W lists the power requirements for the HPG. Table 9A.W HPG Power Requirements Item
9A.5.3 HPG Node Address Setting
Specifications
Rated Input Voltage
5V dc
Power Source Voltage Range
4.75-5.25V dc
Power Consumption
Less than 0.4A
Connection
2-M3 Terminals
Distance from Power Supply
Less than 5 meters
Each HPG must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned to each HPG in the I/O assignment file. Select the node address using the switch assembly shown in Figure 9A.25. Table 9A.X lists the required switch assembly settings for each possible node address. Figure 9A.25 HPG Interface Board Switch Assembly Location Bottom of HPG ON 1
2
3
Back of HPG 11273-I
9A-43