Page 501

Section 9A Operator Interface

Figure 9A.19 shows the input circuit diagram for the MTB I/O module. Figure 9A.19 MTB I/O Module Input Circuit Diagram Push-Button MTB Panel

Push-Button MTB Panel I/O Module

CMOS Input

Switch Common

Converted to Optic Signal

Common 3A AMP fuse

Operator Panel

Fiber optics

+12V + -

Common

DC power supply

11269-I

Output Specifications Table 9A.P lists the output specifications for the circuit that outputs the operation status to the push-button MTB panel. Table 9A.P MTB I/O Module Output Specifications Item

9A-34

Specifications

Remark

A-B MTB Panel

Custom MTB Panel

Number of Output Points

37

18

Modal Group Outputs

19

Non- I/O Outputs

Discrete Outputs

18

I/O Outputs

Output Type

Sink/Source

Totem Pole Driver Output

Output Voltage Range

9.3-13.2V dc

Output Current at ON

Less than 125mA

Output Voltage Drop at ON

Less than 1 V DC

Number of Common Points

22

Isolation

Non-Isolated type

Connection

60 Pin Flat Cable Connector (CN52)

Per Each Output Internally Connected to Power Supply Max. Length 1m

Page 502

Section 9A Operator Interface

Figure 9A.20 shows the output circuit diagram for the MTB I/O module. Figure 9A.20 MTB I/O Module Output Circuit Diagram

Push-Button MTB Panel I/O Module Push-Button MTB Panel Fiber optics

Output

Load Converted from optical to electrical signal

Common

+12V

Operator Panel

Common

DC power supply 11860-I

9A.4.1.2 MTB Panel I/O Module Fiber Optic Connection

Table 9A.Q shows the connectors used to make the fiber optic connections to the I/O ring. Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Table 9A.Q MTB I/O Module Fiber Optic Connectors Connector On Motherboard

Connected To

Remark

OP11 (RED)

Receiver on next module in I/O ring

Output

OP12 (BLACK)

Transmitter on previous module in I/O ring

Input

9A-35

Page 503

Section 9A Operator Interface

9A.4.1.3 MTB I/O Module Mode Setting

If you are using a custom MTB panel you need to set a jumper so that the I/O module can interface with the MTB panel. If you have an Allen-Bradley MTB panel, you don’t need to set this jumper because it is preset. Set the jumper as shown:

+12V DC GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2

CN52

MTB Panel Type

Pins to cover with the shorting post

Custom

3 and 2

Allen-Bradley

1 and 2

PANEL JPR3 CUSTOM

9A.4.1.4 MTB I/O Module Node Address Setting

A-B

Each push-button MTB panel must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned to each push-button MTB panel I/O module in the I/O assignment file. The node address is selected by cutting the jumpers located on the push-button MTB panel I/O module. Figure 9A.21 shows the location of the jumpers. Figure 9A.21 MTB I/O Module Jumper Positions

+12V DC GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2

CN52 I/O ring fault indicator

9A-36

3 2 1

Page 504

Section 9A Operator Interface

Set the node address by cutting the wire jumper(s) on the push-button MTB panel I/O module, according to Table 9A.R shown below. Table 9A.R MTB I/O Module Node Address Setting Node Address

Jumper

Hexidecimal

Binary

JP1

JP2

00

00

Short

Short

01

01

Short

Open

02

10

Open

Short

03

11

Open

Open

The node address may be any number between 00 and 03. You may have a total of 4 MTB panels on the Fiber Optic I/O ring. The same node address can be used for different types of modules, but may not be used more than once for a specific type of module.

9A.4.2 MTB Panel Connectors and Pin Assignments (Direct I/O version)

Figure 9A.22 shows the connectors used to connect the Direct I/O push-button MTB panel to your I/O system. The Direct I/O version of the MTB Panel provides for 51 inputs to and 38 outputs from the I/O system. These inputs and outputs provide machine control functions for the operator to affect the Machine logic (PAL) program. A separate I/O ring device must be used to interface this panel to the 9/Series control.

9A-37

Page 505

Section 9A Operator Interface

Figure 9A.22 Direct I/O MTB Panel Connectors Output conector CN2 Pin 1

Control ON lamp

Input conector CN1 operation selection

Pin 1

P1 CN 1

CN 2

1 2 3

MTBI

MTBD

Direct I/O MTB panel integration 1) Note the locations of pin number one (#1) of CN1 and CN2 . Although the pin #1 locations are the same with respect to the connector keying, the connectors are oriented differently. 2) The P1 jumper is used to set the operation of the “control on” Lamp. In the 1--2 position (MTBD) the lamp is controlled by the I/O system (on when 24V is applied to pin CN2--32). In the 2--3 position (MTBI) the lamp is on whenever 24V is applied to the panel.

Input Interface Connector Input signals from the direct I/O MTB panel are sent through input connector CN 1 . These signals are available for use by the I/O system by pins supplied with this panel. Table 9A.S shows the pin assignments and functions for input interface ribbon cable on the push-button MTB panel.

9A-38

Page 506

Section 9A Operator Interface

Table 9A.S Direct I/O MTB Panel Input connector ( CN 1 ) Pin Assignments Pin No.

Function

Pin No.

Function

1

+24 V

2

Cycle Stop

3

+24 V

4

Cycle Start

5

+24 V

6

Single Block

7

+24 V

8

+X

9

+24 V

10

+Y

11

+24 V

12

+Z

13

AUTO

14

+4

15

MDI

16

-X

17

MANUAL

18

-Y

19

INCR

20

-Z

21

CONT

22

-4

23

HAND

24

TRVRS

25

HOME

26

F5

27

X1

28

F6

29

X10

30

F1

31

X100

32

F2

33

X1000

34

F3

35

X10000

36

F4

37

Rapid Override F1

38

Feedrate Override “a”

39

Rapid Override 25

40

Feedrate Override “b”

41

Spindle Speed Override “d”

42

Feedrate Override “c”

43

Spindle Speed Override “c”

44

Feedrate Override “d”

45

Spindle Speed Override “b”

46

Not Used

47

Spindle Speed Override “a”

48

Not Used

49

Rapid Override 50

50

Not Used

51

Rapid Override 100

52

Power Off

53

CCW

54

On / Off Pushbutton Common

55

OFF

56

Power On

57

CW

58

E-stop

59

Reset

60

E-stop PB Common

Output Interface connector Output signals from the I/O system are sent to the Lamps on the Direct MTB panel via the output interface connector CN 2. Table 9A.T shows the pin assignments and functions for this connector. 9A-39

Page 507

Section 9A Operator Interface

Table 9A.T Direct I/O MTB Panel Output connector ( CN 2 ) Pin Assignments Pin No.

9A-40

Function

Pin No.

Function

1

Ground

2

Cycle Stop

3

Gnd

4

Cycle Start

5

Gnd

6

Single Block

7

Gnd

8

+X

9

Gnd

10

+Y

11

Gnd

12

+Z

13

Gnd

14

+4

15

Gnd

16

-X

17

F4

18

-Y

19

F3

20

-Z

21

F2

22

-4

23

F1

24

Trvrs

25

F6

26

F5

27

AUTO

28

Not Used

29

MDI

30

Not Used

31

MANUAL

32

MANUAL

33

Rapid override F1

34

Contro On (if P1 is set to 1- 2)

35

Rapid Override 25

36

Not Used

37

Rapid Override 50

38

Not Used

39

Rapid Override 100

40

Not Used

41

CCW

42

X1

43

OFF

44

X 10

45

CW

46

X 100

47

INCR

48

X 1000

49

CONT

50

X 10 000

51

HAND

52

GND

53

HOME

54

GND

55

GND

56

GND

57

GND

58

GND

59

GND

60

GND

Page 508

Section 9A Operator Interface

9A.5 HPG (Hand Pulse Generator)

The Hand Pulse Generator (HPG) is a hand wheel used for manual operation of the the control’s axes. The HPGs are generally used to jog axes into position. The operator panel power supply provides power for three Hand Pulse Generators. The HPG is composed of two parts, the HPG itself and the HPG interface board. The HPG interface board is used to interface the HPG with the fiber optic I/O ring. Fiber optic cables are connected to the optical receiver (black) and transmitter (red) on the HPG interface board. The fiber optic cables and connectors are supplied by the system installer. For more information on fiber optics refer to page 7B-1. Figure 9A.23 shows the HPG (Hand Pulse Generator). Figure 9A.23 HPG (Hand Pulse Generator)

Front

Side

Bottom

I/O Ring Fault Indicator DIP switch

Fiber optic connectors +5V dc terminal Common terminal

11271-I

9A-41

Page 509

Section 9A Operator Interface

9A.5.1 HPG Connectors

Figure 9A.24 shows the connectors and terminal block used to make connections to the HPG interface board. Figure 9A.24 HPG Interface Board Connectors and Terminal Block Rear

+5V dc GND OP13 OP14 (OUT) (IN) Optical connectors From Operator Panel power supply

Table 9A.U shows the power supply connections to the HPG interface board. Table 9A.U HPG Power Supply Connectors HPG Connector Terminal

Connected To

BT23

+5V

Operator Panel

GND

Power Supply

Mating Connector BT03

5V dc GND

Cable Number

Remark

C28

Input Output

Table 9A.V shows the connectors used to make the fiber optic connections to the I/O ring. Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Refer to page 7B-1 for additional information on fiber optic cables and connectors.

9A-42

Page 510

Section 9A Operator Interface

Table 9A.V HPG Fiber Optic Connectors

9A.5.2 HPG Power Requirements

Connector On Motherboard

Connected To

Remark

OP13 (RED)

Receiver on next module in I/O ring

Output

OP14 (BLACK)

Transmitter on previous module in I/O ring

Input

The HPGs require a +5V dc power supply. This is supplied from connector BT03 on the operator panel power supply. If the control uses more than three HPGs the system installer will have to provide an external power supply. Table 9A.W lists the power requirements for the HPG. Table 9A.W HPG Power Requirements Item

9A.5.3 HPG Node Address Setting

Specifications

Rated Input Voltage

5V dc

Power Source Voltage Range

4.75-5.25V dc

Power Consumption

Less than 0.4A

Connection

2-M3 Terminals

Distance from Power Supply

Less than 5 meters

Each HPG must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned to each HPG in the I/O assignment file. Select the node address using the switch assembly shown in Figure 9A.25. Table 9A.X lists the required switch assembly settings for each possible node address. Figure 9A.25 HPG Interface Board Switch Assembly Location Bottom of HPG ON 1

2

3

Back of HPG 11273-I

9A-43