The text of a manual · part 50 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 491 to 500
Pages 491 to 500 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 491
Section 9A Operator Interface
Connect the video signal cable to only one interface assembly. Construct the cable shown in Figure 9A.15 to jumper the video signal to the second interface assembly. ATTENTION: Use PAL to select which keyboard is the active keyboard ($KYB_SEL) in conjunction with some external device hardware. PAL should allow an operator to connect his keyboard, and lock out other keyboards from access to the I/O ring. Other keyboards can than be connected to the ring for monitoring but their keyboard inputs will be ignored. Failing to do this check will allow the connection of more than one functioning operator panel at one time which, in some applications, can be dangerous to equipment or personnel.
Use the following procedure to connect multiple removable operator panel interface assemblies. 1.
Connect the video signal to both interface assemblies. This is accomplished by connecting the video signal from the processor to one interface assembly and jumping the video signal out of CN4 on the interface assembly to the video connection on the second interface assembly. The total video signal cable length must be less than 100 feet (including from processor to interface assembly, between interface assemblies, and to portable operator panel).
Figure 9A.15 Connecting Multiple Removable Operator Panel Interface Assemblies Connect Video Cable C09 from 9/Series Processor
Construct this cable to connect video signal between two interface assemblies. We recommend using Belden 9503 for lengths less than 50 ft.. One end of cable will have a 37 pin D shell with sockets, the other end will have a 15 pin D shell with sockets.
Connect Second Interface Assembly Video (37 pin D Shell has pins)
Indicates twisted pairs
21 22
24 23 26 25
Interface Assembly 1
9A-24
N.C. N.C.
9
N.C. N.C. N.C. N.C. N.C. N.C.
11
10
12 13 14 15
1 2 3 4 5 6 7 8
Interface Assembly 2
Page 492
Section 9A Operator Interface
2.
Connect AC power from the main power supply to the interface assemblies. Daisy chain the power between the two assemblies. The standard 9/Series power supply can supply power for two interface assemblies. If your system requires more than two interface assemblies in the same ring you must supply your own external power to the interface assemblies. All interface assemblies in the I/O ring must be powered when the system is running.
GND12VGND5VGND5V GND5V PE L2 L1 AC
To 9/Series Main Power Supply
GND12VGND5VGND5V GND5V PE L2 L1 AC
3.
Connect the 9/Series Fiber optic ring. Other devices can be in the ring at any location but are not shown here for clarity.
9A-25
Page 493
Section 9A Operator Interface
9A.4 MTB Panels
There are three versions of the Pushbutton MTB panel available for use with the 9/Series controls. Standard MTB panel -- fiber optic
(MTB2)
MTB Panel with LED Lamps -- fiber optic
(MTBL)
MTB with LED lamps-- direct inputs /outputs
(MTB24)
The first two of these panels are identical except for the type of illumination in the push buttons. They both are a combination of machine tool builders (MTB) pushbutton panel and a fiber optic I/O module. This combination provides the push-button MTB panel with direct fiber optic communication to the control. The third type of MTB panel does not have the fiber optic interface module, but provides connection from the panel using direct 24 V DC inputs and outputs. An external Fiber Optic interface device is required to provide an interface to the control. This panel uses LEDs for the Pushbutton lamps. This version of the MTB panel is used where complex switching of the signals between several CNCs is required.
9A-26
Page 494
Section 9A Operator Interface
The push-button MTB panels are used to provide the user with manual control over various system functions. These system functions are selected using the various switches and push buttons on the push-button MTB panel. The selected functions are then interfaced to the control via a fiber optic I/O module. Important: A PAL module that provides the PAL logic necessary to decode the push-button MTB panel functions is available on Motion Control Bulletin Board. Refer to the 9/Series CNC PAL Reference Manual, publication 8520-4.3, for more information. Figure 9A.16 shows a front view of all of the push-button MTB panels. Figure 9A.16 Push-Button MTB panel MODE SELECT AUTO
MDI
JOG SELECT
MAN
INCR
CONT
HAND
HOME
SPEED/MULTIPLY LOW X1
MEDL X10
MEDH X1000
AXIS
SPINDLE
SPINDLE SPEED OVERRIDE
MED X100
HIGH X10000
CCW
50
FUNCTION
CYCLE START
+X
+4
--X
F1
F2
SINGLE BLOCK
+Y
TRVRS
--Y
F3
F4
CYCLE STOP
+Z
--4
--Z
F5
F6
OFF
RAPID FEEDRATE OVERRIDE
FEEDRATE OVERRIDE
0
ON
ESTOP RESET
OFF
120
50
CW
100
%
150
F1
25
50
100
19930
Only the three push-button MTB panels are covered in these sections. The system installer may develop custom MTB panels for specific applications. Refer to the system installer’s literature for any information on custom MTB panels. If a custom MTB panel is to be used, the MTB I/O module can be purchased separately to interface a custom MTB panel with the system I/O ring. To use a custom panel with the I/O module, you must set JPR3 to the Custom Panel position.
9A-27
Page 495
Section 9A Operator Interface
9A.4.1 MTB Panel Connectors and Pin Assignments (fiber- optic versions)
Figure 9A.17 shows the terminal blocks and connectors used to connect both versions Fiber--Optic push-button MTB panels (incandescent and LED lamps). The MTB panel I/O module is interfaced with the system I/O ring using fiber optic cables that are connected to the optical receiver and transmitter on the I/O module. Refer to page 7B-1 for additional information on fiber optic cables and connectors. The MTB I/O module interfaces the push-button MTB panel with the control. It provides 44 inputs and 18 outputs to the system I/O ring. These inputs and outputs provide communication between the push-button MTB panel and the control. Figure 9A.17 Push-Button MTB Panel Terminal Block and Connectors
To Main Power Supply (BT04)
To CNC Processor Board (TB1)
PWR ON PWR COM PWR OFF ESTOP
+12V DC GND
CN51
OP12 (in)
OP11 (out)
ESTOP COM
JPR1 JPR2
CN52 I/O ring fault indicator
RESET
BT20
Table 9A.J shows the terminal connector used to connect the push-button MTB panel to the power supply and the CNC processssor. Table 9A.J Push-Button MTB Panel Terminal Connector BT-20 Connector On Push-Button MTB Panel PWR ON
Connected To Component
Connector
Power Supply
PWR COM
ON BT04
PWR OFF BT-20
E-STOP E- STOP COM RESET
9A-28
Cable Number
SW
C01
COM Motherboard/System Processor
E-STOP BT01
COM RESET
C06
Page 496
Section 9A Operator Interface
Table 9A.K shows additional connectors of the push-button MTB panel. Table 9A.K Push-Button MTB Panel Connectors Connector On Push-Button MTB Panel
Connected To Component
Connector
Cable Number
Remark
+12V
Operator Panel
+12V
GND
Power Supply
Input Interface Ribbon Cable
Standard MTB
CN51
C26
Input
Output Interface Ribbon Cable
Panel I/O Module
CN52
C27
Output
CN56F
Motherboard/System Processor
CN16F
C07
Port B
BT03
GND
C28
Input Interface Ribbon Cable Input signals from the push-button MTB panel are sent through input interface ribbon cable to connector CN51 on the push-button MTB panel I/O module. These signals are then sent to the motherboard via the fiber optic I/O ring. Table 9A.L shows the pin assignments and functions for input interface ribbon cable on the push-button MTB panel. PAL expects the push-button MTB panel input signals, which are shown below, to be sent through the push-button MTB panel I/O module on the corresponding pin numbers. If the input signals differ from those listed in Table 9A.L, the PAL I/O assignments file must be altered. Refer to the 9/Series CNC 9/230,9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information. The default settings at power-up for the push-button MTB panel are: Selection
Default
Mode Select
MAN
Jog Select
CONT
Speed/Multiply
X1
Spindle
OFF
Rapid Feedrate Override
F1
Output Interface Ribbon Cable Output signals from connector CN52 on the push-button MTB panel I/O module are sent to the push-button MTB panel via the output interface ribbon cable. Table 9A.M shows the pin assignments and functions for output interface ribbon cable on the push-button MTB panel. PAL outputs signals to the push-button MTB panel through the push-button MTB panel I/O module on the corresponding pin numbers. If the output signals differ from those listed in Table 9A.M, the PAL I/O assignments file must be altered. Refer to the 9/Series CNC 9/230, 9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information. 9A-29
Page 497
Section 9A Operator Interface
Table 9A.L Push-Button MTB Panel Input Interface Ribbon Cable Pin Assignments Function
Pin No.
Gray Code
PAL Device Name
Pin No.
Function
N/A
CN51-1
2
+12V
Gray Code
PAL Device Name
N/A
N/A
1
Cycle Stop
3
Cycle Start
CN51-3
4
+12V
5
Single Block
CN51-5
6
+12V
7
+X
CN51-7
8
+12V
9
+Y
CN51-9
10
+12V
11
+Z
CN51-11
12
+12V
13
+4
CN51-13
14
AUTO a
CN51-34
15
-X
CN51-15
16
MDI b
CN51-32
17
-Y
CN51-17
18
MANUAL
19
-Z
CN51-19
20
INCR a
CN51-30
21
-4
CN51-21
22
CONT b
CN51-28
23
TRVRS
CN51-23
24
HAND
25
F5
CN51-25
26
HOME
27
F6
CN51-27
28
X1 a
CN51-40
29
F1
CN51-29
30
X10 b
CN51-38
31
F2
CN51-31
32
X100 c
CN51-36
33
F3
CN51-33
34
X1000
35
F4
CN51-35
36
X10000
37
Feedrate Override “a” a
CN51-37
38
Rapid Override F1 a
CN51-45
39
Feedrate Override “b” b
CN51-39
40
Rapid Override 25 b
CN51-47
41
Feedrate Override “c” c
CN51-41
42
Spindle Speed Override “d” d
CN51-42
43
Feedrate Override “d” d
CN51-43
44
Spindle Speed Override “c” c
CN51-44
45
Not Used
N/A
N/A
46
Spindle Speed Override “b” b
CN51-46
47
48
Spindle Speed Override “a” a
CN51-48
49
50
Rapid Override 50
51
Power Off
52
Rapid Override 100
53
Power Common
54
CCW a
CN51-49
55
Power On
56
OFF b
CN51-50
57
E-stop
58
CW
59
E-stop Common
60
Reset
9A-30
N/A
Page 498
Section 9A Operator Interface
Table 9A.M Push-Button MTB Panel Output Interface Ribbon Cable Pin Assignments Pin No.
Function
PAL Device Name
Pin No.
1
Cycle Stop
CN52-1
2
3
Cycle Start
CN52-3
4
5
Single Block
CN52-5
6
7
+X
CN52-7
8
Function
Ground
PAL Device Name N/A
9
+Y
CN52-9
10
11
+Z
CN52-11
12
13
+4
CN52-13
14
15
-X
CN52-15
16
17
-Y
CN52-17
18
F4
CN52-18
19
-Z
CN52-19
20
F3
CN52-20
21
-4
CN52-21
22
F2
CN52-22
23
Trvrs
CN52-23
24
F1
CN52-24
25
Jog Retract
CN52-25
26
F6
CN52-26
27
Ground
N/A
28
AUTO
N/A
29
30
MDI
31
32
MANUAL
33
34
Rapid Override F1
35
36
Rapid Override 25
37
38
Rapid Override 50
39
Not Used
40
Rapid Override 100
41
X1
42
CCW
43
X10
44
OFF
45
X100
46
CW
47
X1000
48
INCR
49
X10000
50
CONT
51
Ground
52
HAND
53
54
HOME
55
56
Ground
57
58
59
60
9A-31
Page 499
Section 9A Operator Interface
Serial Interface Connector CN56F The push-button MTB panel has an optional serial interface connector (CN56F). This connector provides an external interface port for a peripheral’s RS 232 or RS 422 interface cable. It is interfaced with Port B (connector J7) on the motherboard/system processor boards by cable C07. Refer to page 7A-22 for additional information on cable C07. Connector CN56F (8520-D25FS) is a 25 pin D-shell connector that is connected to one end of cable C07. This connector is then mounted on the left side of push-button MTB panel under the connector cover. Figure 9A.18 shows the location and mounting instructions for connector CN56F. Figure 9A.18 Push-Button MTB Panel Optional Connector CN56F Push-Button MTB Panel
Spacer alignment ridge
Screw D-sub connector
Toothed washer
Spacer Spacer alignment ridge 11268-I
Important: The two screws with their corresponding spacers and the serial port cover are included with the push-button MTB panel.
9A-32
Page 500
Section 9A Operator Interface
Power Supply Specifications
9A.4.1.1 MTB I/O Module Specifications
Table 9A.N lists the power requirements for the MTB I/O module. Table 9A.N MTB I/O Module Power Requirements Specifications
Item Rated Input Voltage
12V dc
Power Source Voltage Range
11.5-13.2V dc
Power Consumption
1.3 A typical, 2.6 A maximum
Input Specifications Table 9A.O lists the input specifications for the circuit that receives the signals from the pushbuttons and the selector switches on the push-button MTB panel. Table 9A.O MTB I/O Module Input Specifications Item
Specifications A-B MTB Panel
Custom MTB Panel
Number of Input Points
54
44
Modal Group
19
Discrete I/O
18
Rotary Input
8
Interconnect Group
6
Unused
3
Remark
Total input signals from all switch groups
All MTB Panels Operating Voltage ON OFF
11.5 to 13.2 V dc 0-2V dc
Allowable Voltage Drop
Less than .5V dc
Input Impedance
2.25 K ohms
For External Device
Input Current at ON
5mA
Leakage Current at OFF
Less than 1mA
Response
1-22 msec. Includes Digital Filter Time
OFF ® ON, ON ® OFF
Number of Common Points
6 (per 44 inputs)
Internally connected to Power Supply
Fuse
3A
Protects 12V Power Supply
Isolation
Non-Isolated type
Connection
60 Pin flat cable connector (CN51)
With 12V dc Input
Max. Length 1m
9A-33