Page 491

Section 9A Operator Interface

Connect the video signal cable to only one interface assembly. Construct the cable shown in Figure 9A.15 to jumper the video signal to the second interface assembly. ATTENTION: Use PAL to select which keyboard is the active keyboard ($KYB_SEL) in conjunction with some external device hardware. PAL should allow an operator to connect his keyboard, and lock out other keyboards from access to the I/O ring. Other keyboards can than be connected to the ring for monitoring but their keyboard inputs will be ignored. Failing to do this check will allow the connection of more than one functioning operator panel at one time which, in some applications, can be dangerous to equipment or personnel.

Use the following procedure to connect multiple removable operator panel interface assemblies. 1.

Connect the video signal to both interface assemblies. This is accomplished by connecting the video signal from the processor to one interface assembly and jumping the video signal out of CN4 on the interface assembly to the video connection on the second interface assembly. The total video signal cable length must be less than 100 feet (including from processor to interface assembly, between interface assemblies, and to portable operator panel).

Figure 9A.15 Connecting Multiple Removable Operator Panel Interface Assemblies Connect Video Cable C09 from 9/Series Processor

Construct this cable to connect video signal between two interface assemblies. We recommend using Belden 9503 for lengths less than 50 ft.. One end of cable will have a 37 pin D shell with sockets, the other end will have a 15 pin D shell with sockets.

Connect Second Interface Assembly Video (37 pin D Shell has pins)

Indicates twisted pairs

21 22

24 23 26 25

Interface Assembly 1

9A-24

N.C. N.C.

9

N.C. N.C. N.C. N.C. N.C. N.C.

11

10

12 13 14 15

1 2 3 4 5 6 7 8

Interface Assembly 2

Page 492

Section 9A Operator Interface

2.

Connect AC power from the main power supply to the interface assemblies. Daisy chain the power between the two assemblies. The standard 9/Series power supply can supply power for two interface assemblies. If your system requires more than two interface assemblies in the same ring you must supply your own external power to the interface assemblies. All interface assemblies in the I/O ring must be powered when the system is running.

GND12VGND5VGND5V GND5V PE L2 L1 AC

To 9/Series Main Power Supply

GND12VGND5VGND5V GND5V PE L2 L1 AC

3.

Connect the 9/Series Fiber optic ring. Other devices can be in the ring at any location but are not shown here for clarity.

9A-25

Page 493

Section 9A Operator Interface

9A.4 MTB Panels

There are three versions of the Pushbutton MTB panel available for use with the 9/Series controls. Standard MTB panel -- fiber optic

(MTB2)

MTB Panel with LED Lamps -- fiber optic

(MTBL)

MTB with LED lamps-- direct inputs /outputs

(MTB24)

The first two of these panels are identical except for the type of illumination in the push buttons. They both are a combination of machine tool builders (MTB) pushbutton panel and a fiber optic I/O module. This combination provides the push-button MTB panel with direct fiber optic communication to the control. The third type of MTB panel does not have the fiber optic interface module, but provides connection from the panel using direct 24 V DC inputs and outputs. An external Fiber Optic interface device is required to provide an interface to the control. This panel uses LEDs for the Pushbutton lamps. This version of the MTB panel is used where complex switching of the signals between several CNCs is required.

9A-26

Page 494

Section 9A Operator Interface

The push-button MTB panels are used to provide the user with manual control over various system functions. These system functions are selected using the various switches and push buttons on the push-button MTB panel. The selected functions are then interfaced to the control via a fiber optic I/O module. Important: A PAL module that provides the PAL logic necessary to decode the push-button MTB panel functions is available on Motion Control Bulletin Board. Refer to the 9/Series CNC PAL Reference Manual, publication 8520-4.3, for more information. Figure 9A.16 shows a front view of all of the push-button MTB panels. Figure 9A.16 Push-Button MTB panel MODE SELECT AUTO

MDI

JOG SELECT

MAN

INCR

CONT

HAND

HOME

SPEED/MULTIPLY LOW X1

MEDL X10

MEDH X1000

AXIS

SPINDLE

SPINDLE SPEED OVERRIDE

MED X100

HIGH X10000

CCW

50

FUNCTION

CYCLE START

+X

+4

--X

F1

F2

SINGLE BLOCK

+Y

TRVRS

--Y

F3

F4

CYCLE STOP

+Z

--4

--Z

F5

F6

OFF

RAPID FEEDRATE OVERRIDE

FEEDRATE OVERRIDE

0

ON

ESTOP RESET

OFF

120

50

CW

100

%

150

F1

25

50

100

19930

Only the three push-button MTB panels are covered in these sections. The system installer may develop custom MTB panels for specific applications. Refer to the system installer’s literature for any information on custom MTB panels. If a custom MTB panel is to be used, the MTB I/O module can be purchased separately to interface a custom MTB panel with the system I/O ring. To use a custom panel with the I/O module, you must set JPR3 to the Custom Panel position.

9A-27

Page 495

Section 9A Operator Interface

9A.4.1 MTB Panel Connectors and Pin Assignments (fiber- optic versions)

Figure 9A.17 shows the terminal blocks and connectors used to connect both versions Fiber--Optic push-button MTB panels (incandescent and LED lamps). The MTB panel I/O module is interfaced with the system I/O ring using fiber optic cables that are connected to the optical receiver and transmitter on the I/O module. Refer to page 7B-1 for additional information on fiber optic cables and connectors. The MTB I/O module interfaces the push-button MTB panel with the control. It provides 44 inputs and 18 outputs to the system I/O ring. These inputs and outputs provide communication between the push-button MTB panel and the control. Figure 9A.17 Push-Button MTB Panel Terminal Block and Connectors

To Main Power Supply (BT04)

To CNC Processor Board (TB1)

PWR ON PWR COM PWR OFF ESTOP

+12V DC GND

CN51

OP12 (in)

OP11 (out)

ESTOP COM

JPR1 JPR2

CN52 I/O ring fault indicator

RESET

BT20

Table 9A.J shows the terminal connector used to connect the push-button MTB panel to the power supply and the CNC processssor. Table 9A.J Push-Button MTB Panel Terminal Connector BT-20 Connector On Push-Button MTB Panel PWR ON

Connected To Component

Connector

Power Supply

PWR COM

ON BT04

PWR OFF BT-20

E-STOP E- STOP COM RESET

9A-28

Cable Number

SW

C01

COM Motherboard/System Processor

E-STOP BT01

COM RESET

C06

Page 496

Section 9A Operator Interface

Table 9A.K shows additional connectors of the push-button MTB panel. Table 9A.K Push-Button MTB Panel Connectors Connector On Push-Button MTB Panel

Connected To Component

Connector

Cable Number

Remark

+12V

Operator Panel

+12V

GND

Power Supply

Input Interface Ribbon Cable

Standard MTB

CN51

C26

Input

Output Interface Ribbon Cable

Panel I/O Module

CN52

C27

Output

CN56F

Motherboard/System Processor

CN16F

C07

Port B

BT03

GND

C28

Input Interface Ribbon Cable Input signals from the push-button MTB panel are sent through input interface ribbon cable to connector CN51 on the push-button MTB panel I/O module. These signals are then sent to the motherboard via the fiber optic I/O ring. Table 9A.L shows the pin assignments and functions for input interface ribbon cable on the push-button MTB panel. PAL expects the push-button MTB panel input signals, which are shown below, to be sent through the push-button MTB panel I/O module on the corresponding pin numbers. If the input signals differ from those listed in Table 9A.L, the PAL I/O assignments file must be altered. Refer to the 9/Series CNC 9/230,9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information. The default settings at power-up for the push-button MTB panel are: Selection

Default

Mode Select

MAN

Jog Select

CONT

Speed/Multiply

X1

Spindle

OFF

Rapid Feedrate Override

F1

Output Interface Ribbon Cable Output signals from connector CN52 on the push-button MTB panel I/O module are sent to the push-button MTB panel via the output interface ribbon cable. Table 9A.M shows the pin assignments and functions for output interface ribbon cable on the push-button MTB panel. PAL outputs signals to the push-button MTB panel through the push-button MTB panel I/O module on the corresponding pin numbers. If the output signals differ from those listed in Table 9A.M, the PAL I/O assignments file must be altered. Refer to the 9/Series CNC 9/230, 9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information. 9A-29

Page 497

Section 9A Operator Interface

Table 9A.L Push-Button MTB Panel Input Interface Ribbon Cable Pin Assignments Function

Pin No.

Gray Code

PAL Device Name

Pin No.

Function

N/A

CN51-1

2

+12V

Gray Code

PAL Device Name

N/A

N/A

1

Cycle Stop

3

Cycle Start

CN51-3

4

+12V

5

Single Block

CN51-5

6

+12V

7

+X

CN51-7

8

+12V

9

+Y

CN51-9

10

+12V

11

+Z

CN51-11

12

+12V

13

+4

CN51-13

14

AUTO a

CN51-34

15

-X

CN51-15

16

MDI b

CN51-32

17

-Y

CN51-17

18

MANUAL

19

-Z

CN51-19

20

INCR a

CN51-30

21

-4

CN51-21

22

CONT b

CN51-28

23

TRVRS

CN51-23

24

HAND

25

F5

CN51-25

26

HOME

27

F6

CN51-27

28

X1 a

CN51-40

29

F1

CN51-29

30

X10 b

CN51-38

31

F2

CN51-31

32

X100 c

CN51-36

33

F3

CN51-33

34

X1000

35

F4

CN51-35

36

X10000

37

Feedrate Override “a” a

CN51-37

38

Rapid Override F1 a

CN51-45

39

Feedrate Override “b” b

CN51-39

40

Rapid Override 25 b

CN51-47

41

Feedrate Override “c” c

CN51-41

42

Spindle Speed Override “d” d

CN51-42

43

Feedrate Override “d” d

CN51-43

44

Spindle Speed Override “c” c

CN51-44

45

Not Used

N/A

N/A

46

Spindle Speed Override “b” b

CN51-46

47

48

Spindle Speed Override “a” a

CN51-48

49

50

Rapid Override 50

51

Power Off

52

Rapid Override 100

53

Power Common

54

CCW a

CN51-49

55

Power On

56

OFF b

CN51-50

57

E-stop

58

CW

59

E-stop Common

60

Reset

9A-30

N/A

Page 498

Section 9A Operator Interface

Table 9A.M Push-Button MTB Panel Output Interface Ribbon Cable Pin Assignments Pin No.

Function

PAL Device Name

Pin No.

1

Cycle Stop

CN52-1

2

3

Cycle Start

CN52-3

4

5

Single Block

CN52-5

6

7

+X

CN52-7

8

Function

Ground

PAL Device Name N/A

9

+Y

CN52-9

10

11

+Z

CN52-11

12

13

+4

CN52-13

14

15

-X

CN52-15

16

17

-Y

CN52-17

18

F4

CN52-18

19

-Z

CN52-19

20

F3

CN52-20

21

-4

CN52-21

22

F2

CN52-22

23

Trvrs

CN52-23

24

F1

CN52-24

25

Jog Retract

CN52-25

26

F6

CN52-26

27

Ground

N/A

28

AUTO

N/A

29

30

MDI

31

32

MANUAL

33

34

Rapid Override F1

35

36

Rapid Override 25

37

38

Rapid Override 50

39

Not Used

40

Rapid Override 100

41

X1

42

CCW

43

X10

44

OFF

45

X100

46

CW

47

X1000

48

INCR

49

X10000

50

CONT

51

Ground

52

HAND

53

54

HOME

55

56

Ground

57

58

59

60

9A-31

Page 499

Section 9A Operator Interface

Serial Interface Connector CN56F The push-button MTB panel has an optional serial interface connector (CN56F). This connector provides an external interface port for a peripheral’s RS 232 or RS 422 interface cable. It is interfaced with Port B (connector J7) on the motherboard/system processor boards by cable C07. Refer to page 7A-22 for additional information on cable C07. Connector CN56F (8520-D25FS) is a 25 pin D-shell connector that is connected to one end of cable C07. This connector is then mounted on the left side of push-button MTB panel under the connector cover. Figure 9A.18 shows the location and mounting instructions for connector CN56F. Figure 9A.18 Push-Button MTB Panel Optional Connector CN56F Push-Button MTB Panel

Spacer alignment ridge

Screw D-sub connector

Toothed washer

Spacer Spacer alignment ridge 11268-I

Important: The two screws with their corresponding spacers and the serial port cover are included with the push-button MTB panel.

9A-32

Page 500

Section 9A Operator Interface

Power Supply Specifications

9A.4.1.1 MTB I/O Module Specifications

Table 9A.N lists the power requirements for the MTB I/O module. Table 9A.N MTB I/O Module Power Requirements Specifications

Item Rated Input Voltage

12V dc

Power Source Voltage Range

11.5-13.2V dc

Power Consumption

1.3 A typical, 2.6 A maximum

Input Specifications Table 9A.O lists the input specifications for the circuit that receives the signals from the pushbuttons and the selector switches on the push-button MTB panel. Table 9A.O MTB I/O Module Input Specifications Item

Specifications A-B MTB Panel

Custom MTB Panel

Number of Input Points

54

44

Modal Group

19

Discrete I/O

18

Rotary Input

8

Interconnect Group

6

Unused

3

Remark

Total input signals from all switch groups

All MTB Panels Operating Voltage ON OFF

11.5 to 13.2 V dc 0-2V dc

Allowable Voltage Drop

Less than .5V dc

Input Impedance

2.25 K ohms

For External Device

Input Current at ON

5mA

Leakage Current at OFF

Less than 1mA

Response

1-22 msec. Includes Digital Filter Time

OFF ® ON, ON ® OFF

Number of Common Points

6 (per 44 inputs)

Internally connected to Power Supply

Fuse

3A

Protects 12V Power Supply

Isolation

Non-Isolated type

Connection

60 Pin flat cable connector (CN51)

With 12V dc Input

Max. Length 1m

9A-33