Page 481
Section 9A Operator Interface
9A.3 Removable Operator Panel Installation
Use the removable operator panel on controls installed in locations where operator/machine interface is not needed often and it is practical for one operator panel to be transported from control to control when necessary. The 9/Series removable operator panel allows the connection and disconnection of the operator panel from the control while the control is running. This connection/disconnection takes place without any interruption to control operation and requires no reconfiguration of the control. This functionality is made available through the installation of a separate operator panel interface assembly installed in the 9/Series I/O ring. This interface assembly allows the removable operator panel to be attached or detached from the 9/Series I/O ring without physically breaking the I/O ring. You must install an interface assembly in the 9/Series I/O ring wherever you intend to attach a removable operator panel. All connections between the 9/Series controller and the removable operator panel are made through a single cable. This cable provides all necessary communications to the 9/Series control (I/O ring interface for the keyboard, video signal, and power).
9A-14
Page 482
Section 9A Operator Interface
9A.3.1 Installing the Removable Operator Panel Interface Assembly
The operator panel interface assembly is used to makes all connections between the 9/Series control and the removable operator panel. Install an interface assembly in the 9/Series fiber optic I/O ring at any location you intend to connect a removable operator panel. Figure 9A.9 Placing Operator Panel Interface Assemblies
Servo Amplifier
Operator panel interface assembly Fiber optics to/from other 9/Series I/O devices
9A-15
Page 483
Section 9A Operator Interface
Assigning a Module Address Each interface assembly must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned as independent operator panels in the I/O assignment file found in ODS (see your PAL reference manual). The node address is selected by cutting the jumpers located on the interface assembly(s). Figure 9A.10 shows the location of the jumpers on the interface module. Important: You must remove the cover from the removable operator panel interface assembly to access the node address jumpers. Turn off power to the interface assembly before removing the cover. Make sure to follow proper ESD grounding procedures when working on any 9/Series equipment. Figure 9A.10 Removable Operator Panel Interface Assembly JP1 and JP2 Jumper Locations
GND 12V GND 5V GND 5V GND 5V PE
Jumpers JP2 JP1 Remove cover (2 screws each side) Fiber Optic Connections
AC
L2 L1
Set the node address by cutting the wire jumper(s) according to Table 9A.E. The node address may be any number between 00 and 03. You may have a total of 4 interface assemblies in the 9/Series fiber optic I/O ring. The same node address can be used for other types of modules however, each removable operator panel interface assembly must have its own unique address.
9A-16
Page 484
Section 9A Operator Interface
Reinstall the cover on the interface assembly when you have finished setting your address jumpers.
Connecting the Interface Assembly to the Fiber Optic Ring Fiber optic connection to the keyboard on the removable front panel is made through the interface assembly. Table 9A.F shows the connectors used to make the fiber optic connections to the I/O ring. Each interface assembly connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Refer to page 7B-1 for additional information on fiber optic cables and connectors. Figure 9A.11 Removable Operator Panel Interface Module Fiber Optic Connections
GND 12V GND 5V GND 5V GND 5V PE
Jumpers JP2 JP1
Fiber Optic Connections
AC
L2 L1
Table 9A.F Operator Panel I/O Connectors Connector
Connected To
Remark
RED
Receiver on next module in I/O ring
Output
BLACK
Transmitter on previous module in I/O ring
Input
You must connect both the input and output connectors of all devices on the I/O ring. You can not leave an open connector on any module.
9A-17
Page 485
Section 9A Operator Interface
Interface Assembly Video Connection CN19M Table 9A.G shows the interface assembly video signal connector. Table 9A.G Interface Assembly Video Signal Connection Connector On Motherboard/System Processor
To Connector On Removable Front Panel Interface Assembly
Cable Number (page 7A-24)
J8 15 pin D- shell
CN19M 15 pin D- shell
C09
Remark Video Signal
Video connector CN19M is the connector that connects the removable operator panel interface module to the motherboard (9/260 and 9/290) or processor board (9/230). Figure 9A.12 shows the pin assignments of the video connector CN19M. Figure 9A.12 Video Connector CN19M 15 Pin Male D-shell Connector and Pin Assignment
1
8
9
9A-18
15
Pin No.
Signal Name
Pin No.
1
GND (SHIELD)
9
NC
2
NC
10
GREEN (L)
3
GREEN (H)
11
NC
4
NC
12
NC
5
NC
13
NC
6
NC
14
H-SYNC (L)
7
H-SYNC (H)
15
V-SYNC (L)
8
V-SYNC (H)
Signal Name
Page 486
Section 9A Operator Interface
Figure 9A.13 Removable Operator Panel Interface Module Video Connections
Interface Assembly
Connect Video Cable C09 Vidoe Out CN4
Operator Pnl. CN5
AC
GND12V GND5VGND 5V GND 5V PE L2
Video In CN19M
L1
9/230 Processor Board
Connect Video Cable C09 (connector J8)
Removable Operator Panel Interface Assembly Power Supply Power for the removable operator panel is provided by the interface assembly power supply. The interface assembly also supplies power for HPGs and an MTB panel I/O module. The interface assembly power supply receives power from the main power supply. Connect the ac-H and ac-L terminals on the BT02 terminal strip to the main 9/230 control power supply connector BT04 terminals AUX--H and AUX--L.
9A-19
Page 487
Section 9A Operator Interface
Figure 9A.6 shows the removable operator panel interface assembly power supply. Figure 9A.14 Operator Panel Power Supply
GND 12V GND 5V GND 5V GND 5V PE
Video In CN19M To M TB panel
To H PG
Vidoe Out CN4
Operator Pnl. CN5
To H PG
To H PG
AC
L2
AC
L1
Table 9A.H shows the input and output power connections for the interface assembly power supply. Table 9A.H Interface Assembly Power Supply Connection Connector On Interface Assembly ac-L1 ac-L2 BT02
Connected To Component Connector Main Power Supply
PE +5V dc
BT04
HPG (1)
BT23
HPG (2)
BT23
9A-20
AC Input Earth GND
+5V
C29
Output
+5V
C29
Output
GND
GND HPG (3)
BT23
GND +12V dc GND
C03
GND
GND +5 V dc
Remark
Cabinet Chassis Ground
GND +5 V dc
Aux-H Aux-L
Cable Number
+5V
GND C29
GND MTB Panel I/O Module
MTB I/O
+12V GND
Output GND
C28
Output GND
Page 488
Section 9A Operator Interface
Table 9A.I shows the output specifications of the removable operator panel interface power supply. For input specifications and fuse specifications refer to page 4D-5. Table 9A.I Interface Assembly Power Supply Output Specifications Item Outputs
9A.3.2 Connecting/Disconnecting the Removable Operator Panel
Specifications
Remark
5 V dc (3 terminals) 0.4 A/channel
For HPGs
12 V dc (1 terminal) 1.5 A
For MTB Panel I/O Module
5 V dc
For Keyboard I/O Module
12 V dc
For Monochrome CRT
Protection Function
Overcurrent protection
Connection
Terminal Block
Your removable operator panel connects to the 9/Series control through the removable operator panel interface assembly you installed as discussed on page 9A-15. The connection between removable operator panel and interface assembly is made via a 10 ft (max length) cable. This cable is provided with your removable operator panel. Attach the removable operator panel cable between the interface assembly connector CN5 and the 37--pin D--shell connector on the front of your removable operator panel. You can attach or detach the operator panel at any time. We do not recommend, however, disconnecting this panel while in the middle of editing online or Patch AMP or while editing a part program.
9A-21
Page 489
Section 9A Operator Interface
Removable Operator Panel
Connect Interface Assembly (37---pin D---Shell has pins)
Interface Assembly
Vidoe Out CN4
Operator Pnl. CN5
GND12V GND5VGND 5V GND 5V PE L2 L1 AC
Video In CN19M
Connect Operator Panel (37---pin D---Shell has sockets)
Removable Operator Panel Interface Cable The removable operator panel interface assembly cable has a 37 pin D shell connector at both ends of the cable. The female end of the cable (has sockets) connects to the removable operator panel. The male end of the cable (has pins) connects to the removable operator panel interface assembly. The pin out connections for this cable are as follows:
9A-22
Page 490
Section 9A Operator Interface
Pin number:
Description:
Pin number:
Description:
1
Shld. Chassis Ground
20
Ground
2
Keyboard Data
21
Video Hi
3
Keyboard Data
22
Video Lo
4
Keyboard Data
23
H - Sync Hi
5
Keyboard Data
24
H - Sync Lo
6
Keyboard Data
25
V - Sync Hi
7
Keyboard Data
26
V - Sync Lo
8
Keyboard Data
27
Ground
9
Keyboard Data
28
12 Vdc
10
Keyboard Data
29
12 Vdc
11
Keyboard Data
30
12 Vdc
12
Keyboard Data
31
12 Vdc
13
Keyboard Data
32
12 Vdc
14
Keyboard Data
33
Ground
15
Keyboard Data
34
Ground
16
Keyboard Data
35
Ground
17
Keyboard Data
36
No Connection
18
Keyboard Data
37
No Connection
19
Keyboard Data
9A.3.3 Multiple Removable Operator Panel Assemblies
20
37
1
19
If your machine layout calls for more than one location to plug in your removable operator panel, read this section. Multiple operator panel locations typically require a separate removable operator panel interface assembly at each location. A maximum of four interface modules can exist in the 9/Series fiber optic I/O ring. The interface assembly provides power to the CRT as well as a keyboard interface to the fiber optic ring. Important: It is possible to place a mounted fixed location operator panel on the ring with a removable operator interface assembly at some other location. Call your Allen Bradley support group for details on installing this type of system. For systems with two removable operator panel interface assemblies: Wire the power supplies for both interface assemblies Connect the KBI interface to the fiber optic ring for both assemblies 9A-23