Page 471

Section 9A Operator Interface

9A.2 Mounted Operator Panel Installation

The mounted operator panels are typically mounted directly in a cabinet and are fixed in their location. It is directly linked to the 9/Series fiber optic ring, and contains its own power supply. The video signal is connected directly through a cable from the main processor to the CRT. Figure 9A.2 shows the connectors and terminal blocks of the monochrome operator panel. Figure 9A.2 Monochrome Operator Panel Connectors and Terminal Blocks Front

Operator Panel

Optical in OP04 Optical out OP03

BT02 L1 L2

Rear AC

PE

9A-4

5V GND

To HPG

5V GND

To HPG

5V GND

To HPG

12V GND

To MTB Panel I/O Module

CN19M

Page 472

Section 9A Operator Interface

Figure 9A.3 shows the connectors and terminal blocks of the CRT color operator panel. Figure 9A.3 Color CRT Operator Panel Connectors and Terminal Blocks

CN19M

Back of Panel

Optical in OP04

Optical out OP03

BT02

AC

L1

L2

PE

5V HPG GND

5V

GND

12V

GND

5V HPG GND

HPG

MTB

9A-5

Page 473

Section 9A Operator Interface

Figure 9A.4 shows the connectors and terminal blocks of the color flat panel operator panel. Figure 9A.4 Color Flat Panel Operator Panel Connectors and Terminal Blocks Optical in OP04

Optical out OP03

Operator Panel Power Supply

Video Connection

BT02

AC

Fiber Optic Connection

L1 L2 PE 5V

HPG GND 5V HPG GND HPG

MTB

5V GND 12V GND

9A.2.1 Mounted Operator Panel Video Connector

Table 9A.A shows the mounted operator panel video signal connector CN19M. Table 9A.A Operator Panel Video Signal Connection Connector On Operator Panel CN19M

Connected To Component Motherboard/System Processor

Cable Number

Remark

Connector Video

C09

Video Signal

Video connector CN19M is the connector that connects the video monitor with the motherboard (9/260 and 9/290) or processor board (9/230 and 9/440). Figure 9A.5 shows video connector CN19M.

9A-6

Page 474

Section 9A Operator Interface

Figure 9A.5 shows the pin assignments of video connector CN19M. Figure 9A.5 Video Connector CN19M 15 Pin Male D-Shell Connector (has pins) Pin Assignment

1

8

9

9A.2.2 Mounted Operator Panel Power Supply

15

Pin No.

Signal Name

Pin No.

Signal Name

1

GND (SHIELD)

9

RED (L)

2

RED (H)

10

GREEN (L)

3

GREEN (H)

11

BLUE (L)

4

BLUE (H)

12

NC

5

NC

13

CLOCK (L)

6

CLOCK (H)

14

H-SYNC (L)

7

H-SYNC (H)

15

V-SYNC (L)

8

V-SYNC (H)

The monochrome, color, and color flat panel operator panels use the operator panel power supply. It supplies power to the monochrome and color flat panel displays (+12 V dc), the keyboard I/O ring interface (+5 V dc), the HPGs, and the MTB panel I/O module (note the color CRT uses 115V from the main power supply). The operator panel power supply receives power from the main power supply. Figure 9A.6 shows the operator panel power supply. Figure 9A.6 Operator Panel Power Supply BT02

L1 L2 PE 5V GND 5V GND 5V GND 12V GND

AC

To HPG To HPG To HPG To MTB panel I/O module

9A-7

Page 475

Section 9A Operator Interface

Table 9A.B shows the input and output power connections for the operator panel power supply. Table 9A.B Operator Panel Power Supply Connection Connected To Component Connector

Connector On Operator Panel AC-L1 AC-L2 BT02

Main Power Supply

PE

BT04

Cable Number

Remark

C03

AC Input

AUX-H AC-L

Cabinet Chassis Ground

+5V dc

HPG (1)

Earth GND

BT23

+5V

GND

C29

GND

+5 V dc

HPG (2)

BT23

HPG (3)

BT23

GND

+5V

GND

C29

Output

C29

Output

GND

+5 V dc

GND

+5V

GND

GND

+12V dc GND

MTB Panel I/O Module

MTB I/O

GND

+12V GND

CN1

Keyboard I/O Ring Interface

CN2

Monochrome and Flat Panel Circuit Board

Output

C28

CN23

Output GND +5V dc +12V dc

Table 9A.C shows the output specifications of the operator panel power supply. For input specifications and fuse specifications refer to page 4D-5. Table 9A.C Operator Panel Power Supply Output Specifications Item Outputs

9A-8

Specifications

Remark

5 V dc (3 terminals) 0.4 A/channel

For 3 HPGs

12 V dc (1 terminal) 1.5 A

For MTB Panel I/O Module

5 V dc

For Keyboard I/O Module

12 V dc

For Monochrome and Flat Panel

Protection Function

Overcurrent protection

Connection

Terminal Block

Page 476

Section 9A Operator Interface

Important: The color CRT operator panel has an additional internal power supply that is used to power the color CRT. The ac power supply cable, cable C03, provides ac power to the sub power supply terminal on the rear of the color operator panel as shown in Figure 9A.3. The ac power supply is jumpered internally to the color CRT power supply from operator panel power supply.

9A.2.3 Mounted Operator Panel Fiber Optic Connection

Fiber optic connection is made through the operator panel I/O interface card mounted on the back of the operator panel. Table 9A.F shows the connectors used to make the fiber optic connections to the I/O ring. Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Refer to page 7B-1 for additional information on fiber optic cables and connectors. Figure 9A.2, Figure 9A.3, and Figure 9A.4 shows the location of these connectors. Table 9A.D Operator Panel I/O Connectors Connector

Connected To

Remark

RED

Receiver on next module in I/O ring

Output (OP03)

BLACK

Transmitter on previous module in I/O ring

Input (OP04)

9A-9

Page 477

Section 9A Operator Interface

9A.2.4 Mounted Operator Panel Node Address Setting

Each operator panel must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned to each operator panel in the I/O assignment file. The node address is selected by cutting the jumpers located on the operator panel. Figure 9A.7 shows the location of the jumpers on the operator panel. Figure 9A.7 Operator Panel Jumper Location Front Operator Panel

Rear BT02

L1 L2

AC

PE

JP1 JP2

5V GND 5V GND 5V GND 12V GND

To HPG To HPG To HPG To MTB panel I/O module

The preceding figure shows the jumpers located on the keyboard I/O ring interface board of the the monochrome operator panel. This board is also used by the color and color flat panel operator panels. Locate this board by the fiber optic connections.

9A-10

Page 478

Section 9A Operator Interface

Set the node address by cutting the wire jumper(s) according to Table 9A.E shown below. Table 9A.E Operator and Removable Operator Panel Node Address Setting Node Address

Jumper

Hexidecimal

Binary

JP1

JP2

00

00

Short

Short

01

01

Open

Short

02

10

Short

Open

03

11

Open

Open

The node address may be any number between 00 and 03. You may have a total of 4 interface assemblies on the I/O ring (if the removable operator panel interface is used a separate power supply is required if you use more than 2 assemblies). The same node address can be used for different types of modules, but may not be used more than once for a specific type of module.

9A.2.5 Flat Panel Horizontal Adjustment

The flat screen operator panel has a set of dip switches used to adjust the screens horizontal centering. Screen centering on the flat panel must be adjusted for different connecting control types. Figure 9A.8 illustrates the location and use of these dip switches. Figure 9A.8 Flat Operator Panel Horizontal Adjustment Dip Switches HOR PHASE 1 2 3 4 56 7 8

ON

For this control type:

Sw 1

Sw 2

SW SW SW SW SW SW 3 4 5 6 7 8

9/230, 9/260, and 9/290 CNCs

On

Off

On

Off

Off

Off

Off

Off

9/440 CNCs (factory default)

On

On

On

On

Off

Off

Off

Off

Video Connection Fiber Optic Connection

9A-11

Page 479

Section 9A Operator Interface

9A.2.6 Keyboard Interface Jumper JP3

Jumper JP3 on the operator panel keyboard interface is used to determine if the keyboard interface module is attached to a monochrome or color operator panel (note these keyboard configurations are different). This jumper comes preset from the factory in the correct position for your operator panel. Adjustment of this jumper should only be made when replacing the operator panel keyboard interface module. Set the color or monochrome operator panel jumper (JP3) to match the type of operator panel you have. The following table illustrates proper setting of JP3. Jumper JP3 Setting

For this Operator Panel: Color and Flat Panel Operator Panels

MOP JP3

COP MOP

Monochrome Operator Panel JP3

COP

COP

MOP

JP3

JP3 shown configured for color operator panel.

9A.2.7 Adjusting Monitor Intensity

JP3

JP1 JP2

Monitor intensity is controlled by adjusting the contrast on monochrome and color CRT systems. No intensity adjustments are available for the flat operator panels. Monitor intensity adjustment is typically not required on the operator panels as they are adjusted to an acceptable level before shipping from the factory. In the event that you think you must alter the monitor intensity use the following procedure:

9A-12

Page 480

Section 9A Operator Interface

1.

Remove power from the operator panel.

2.

Remove the plastic cover from the back of the operator panel. The cover is attached with three plastic snap pins at the bottom of the cover. Pull these pins until they snap free of the operator panel.

3.

Using a small screw driver, adjust the contrast or sub contrast pot as shown below. Note these pots are labeled on the printed circuit board:

Color CRTs

Monochrome CRTs

Use Sub- Contrast Pot found at far right of video connector (Color CRT only)

Use Contrast Pot found behind video connector (Monochrome CRT only)

Important: We do not recommend adjusting any of the “Brightness” pots located on either CRT types. The brightness controls are preset at the factory for optimum monitor performance and reliability. 4.

Re--attach the plastic cover to the back of the operator panel.

5.

Re--establish power to the operator panel.

6.

Repeat steps 1 thru 5 until the desired monitor intensity is reached.

9A-13