Page 471
Section 9A Operator Interface
9A.2 Mounted Operator Panel Installation
The mounted operator panels are typically mounted directly in a cabinet and are fixed in their location. It is directly linked to the 9/Series fiber optic ring, and contains its own power supply. The video signal is connected directly through a cable from the main processor to the CRT. Figure 9A.2 shows the connectors and terminal blocks of the monochrome operator panel. Figure 9A.2 Monochrome Operator Panel Connectors and Terminal Blocks Front
Operator Panel
Optical in OP04 Optical out OP03
BT02 L1 L2
Rear AC
PE
9A-4
5V GND
To HPG
5V GND
To HPG
5V GND
To HPG
12V GND
To MTB Panel I/O Module
CN19M
Page 472
Section 9A Operator Interface
Figure 9A.3 shows the connectors and terminal blocks of the CRT color operator panel. Figure 9A.3 Color CRT Operator Panel Connectors and Terminal Blocks
CN19M
Back of Panel
Optical in OP04
Optical out OP03
BT02
AC
L1
L2
PE
5V HPG GND
5V
GND
12V
GND
5V HPG GND
HPG
MTB
9A-5
Page 473
Section 9A Operator Interface
Figure 9A.4 shows the connectors and terminal blocks of the color flat panel operator panel. Figure 9A.4 Color Flat Panel Operator Panel Connectors and Terminal Blocks Optical in OP04
Optical out OP03
Operator Panel Power Supply
Video Connection
BT02
AC
Fiber Optic Connection
L1 L2 PE 5V
HPG GND 5V HPG GND HPG
MTB
5V GND 12V GND
9A.2.1 Mounted Operator Panel Video Connector
Table 9A.A shows the mounted operator panel video signal connector CN19M. Table 9A.A Operator Panel Video Signal Connection Connector On Operator Panel CN19M
Connected To Component Motherboard/System Processor
Cable Number
Remark
Connector Video
C09
Video Signal
Video connector CN19M is the connector that connects the video monitor with the motherboard (9/260 and 9/290) or processor board (9/230 and 9/440). Figure 9A.5 shows video connector CN19M.
9A-6
Page 474
Section 9A Operator Interface
Figure 9A.5 shows the pin assignments of video connector CN19M. Figure 9A.5 Video Connector CN19M 15 Pin Male D-Shell Connector (has pins) Pin Assignment
1
8
9
9A.2.2 Mounted Operator Panel Power Supply
15
Pin No.
Signal Name
Pin No.
Signal Name
1
GND (SHIELD)
9
RED (L)
2
RED (H)
10
GREEN (L)
3
GREEN (H)
11
BLUE (L)
4
BLUE (H)
12
NC
5
NC
13
CLOCK (L)
6
CLOCK (H)
14
H-SYNC (L)
7
H-SYNC (H)
15
V-SYNC (L)
8
V-SYNC (H)
The monochrome, color, and color flat panel operator panels use the operator panel power supply. It supplies power to the monochrome and color flat panel displays (+12 V dc), the keyboard I/O ring interface (+5 V dc), the HPGs, and the MTB panel I/O module (note the color CRT uses 115V from the main power supply). The operator panel power supply receives power from the main power supply. Figure 9A.6 shows the operator panel power supply. Figure 9A.6 Operator Panel Power Supply BT02
L1 L2 PE 5V GND 5V GND 5V GND 12V GND
AC
To HPG To HPG To HPG To MTB panel I/O module
9A-7
Page 475
Section 9A Operator Interface
Table 9A.B shows the input and output power connections for the operator panel power supply. Table 9A.B Operator Panel Power Supply Connection Connected To Component Connector
Connector On Operator Panel AC-L1 AC-L2 BT02
Main Power Supply
PE
BT04
Cable Number
Remark
C03
AC Input
AUX-H AC-L
Cabinet Chassis Ground
+5V dc
HPG (1)
Earth GND
BT23
+5V
GND
C29
GND
+5 V dc
HPG (2)
BT23
HPG (3)
BT23
GND
+5V
GND
C29
Output
C29
Output
GND
+5 V dc
GND
+5V
GND
GND
+12V dc GND
MTB Panel I/O Module
MTB I/O
GND
+12V GND
CN1
Keyboard I/O Ring Interface
CN2
Monochrome and Flat Panel Circuit Board
Output
C28
CN23
Output GND +5V dc +12V dc
Table 9A.C shows the output specifications of the operator panel power supply. For input specifications and fuse specifications refer to page 4D-5. Table 9A.C Operator Panel Power Supply Output Specifications Item Outputs
9A-8
Specifications
Remark
5 V dc (3 terminals) 0.4 A/channel
For 3 HPGs
12 V dc (1 terminal) 1.5 A
For MTB Panel I/O Module
5 V dc
For Keyboard I/O Module
12 V dc
For Monochrome and Flat Panel
Protection Function
Overcurrent protection
Connection
Terminal Block
Page 476
Section 9A Operator Interface
Important: The color CRT operator panel has an additional internal power supply that is used to power the color CRT. The ac power supply cable, cable C03, provides ac power to the sub power supply terminal on the rear of the color operator panel as shown in Figure 9A.3. The ac power supply is jumpered internally to the color CRT power supply from operator panel power supply.
9A.2.3 Mounted Operator Panel Fiber Optic Connection
Fiber optic connection is made through the operator panel I/O interface card mounted on the back of the operator panel. Table 9A.F shows the connectors used to make the fiber optic connections to the I/O ring. Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Refer to page 7B-1 for additional information on fiber optic cables and connectors. Figure 9A.2, Figure 9A.3, and Figure 9A.4 shows the location of these connectors. Table 9A.D Operator Panel I/O Connectors Connector
Connected To
Remark
RED
Receiver on next module in I/O ring
Output (OP03)
BLACK
Transmitter on previous module in I/O ring
Input (OP04)
9A-9
Page 477
Section 9A Operator Interface
9A.2.4 Mounted Operator Panel Node Address Setting
Each operator panel must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned to each operator panel in the I/O assignment file. The node address is selected by cutting the jumpers located on the operator panel. Figure 9A.7 shows the location of the jumpers on the operator panel. Figure 9A.7 Operator Panel Jumper Location Front Operator Panel
Rear BT02
L1 L2
AC
PE
JP1 JP2
5V GND 5V GND 5V GND 12V GND
To HPG To HPG To HPG To MTB panel I/O module
The preceding figure shows the jumpers located on the keyboard I/O ring interface board of the the monochrome operator panel. This board is also used by the color and color flat panel operator panels. Locate this board by the fiber optic connections.
9A-10
Page 478
Section 9A Operator Interface
Set the node address by cutting the wire jumper(s) according to Table 9A.E shown below. Table 9A.E Operator and Removable Operator Panel Node Address Setting Node Address
Jumper
Hexidecimal
Binary
JP1
JP2
00
00
Short
Short
01
01
Open
Short
02
10
Short
Open
03
11
Open
Open
The node address may be any number between 00 and 03. You may have a total of 4 interface assemblies on the I/O ring (if the removable operator panel interface is used a separate power supply is required if you use more than 2 assemblies). The same node address can be used for different types of modules, but may not be used more than once for a specific type of module.
9A.2.5 Flat Panel Horizontal Adjustment
The flat screen operator panel has a set of dip switches used to adjust the screens horizontal centering. Screen centering on the flat panel must be adjusted for different connecting control types. Figure 9A.8 illustrates the location and use of these dip switches. Figure 9A.8 Flat Operator Panel Horizontal Adjustment Dip Switches HOR PHASE 1 2 3 4 56 7 8
ON
For this control type:
Sw 1
Sw 2
SW SW SW SW SW SW 3 4 5 6 7 8
9/230, 9/260, and 9/290 CNCs
On
Off
On
Off
Off
Off
Off
Off
9/440 CNCs (factory default)
On
On
On
On
Off
Off
Off
Off
Video Connection Fiber Optic Connection
9A-11
Page 479
Section 9A Operator Interface
9A.2.6 Keyboard Interface Jumper JP3
Jumper JP3 on the operator panel keyboard interface is used to determine if the keyboard interface module is attached to a monochrome or color operator panel (note these keyboard configurations are different). This jumper comes preset from the factory in the correct position for your operator panel. Adjustment of this jumper should only be made when replacing the operator panel keyboard interface module. Set the color or monochrome operator panel jumper (JP3) to match the type of operator panel you have. The following table illustrates proper setting of JP3. Jumper JP3 Setting
For this Operator Panel: Color and Flat Panel Operator Panels
MOP JP3
COP MOP
Monochrome Operator Panel JP3
COP
COP
MOP
JP3
JP3 shown configured for color operator panel.
9A.2.7 Adjusting Monitor Intensity
JP3
JP1 JP2
Monitor intensity is controlled by adjusting the contrast on monochrome and color CRT systems. No intensity adjustments are available for the flat operator panels. Monitor intensity adjustment is typically not required on the operator panels as they are adjusted to an acceptable level before shipping from the factory. In the event that you think you must alter the monitor intensity use the following procedure:
9A-12
Page 480
Section 9A Operator Interface
1.
Remove power from the operator panel.
2.
Remove the plastic cover from the back of the operator panel. The cover is attached with three plastic snap pins at the bottom of the cover. Pull these pins until they snap free of the operator panel.
3.
Using a small screw driver, adjust the contrast or sub contrast pot as shown below. Note these pots are labeled on the printed circuit board:
Color CRTs
Monochrome CRTs
Use Sub- Contrast Pot found at far right of video connector (Color CRT only)
Use Contrast Pot found behind video connector (Monochrome CRT only)
Important: We do not recommend adjusting any of the “Brightness” pots located on either CRT types. The brightness controls are preset at the factory for optimum monitor performance and reliability. 4.
Re--attach the plastic cover to the back of the operator panel.
5.
Re--establish power to the operator panel.
6.
Repeat steps 1 thru 5 until the desired monitor intensity is reached.
9A-13