Page 461

Section 8 Communication Interface

You are ready to start receiving and transmitting remote I/O information. As the remote I/O module responds to commands, you should see this LED pattern:

8.9.4 9/440 Remote I/O Connection

LED

Status

Description

DS4 NA COMM ACTIVE

ON

Active Link to PLC. This is the normal state when the RIO link is active.

FLASHING

The remote I/O link is active but the PLC is currently in program mode.

OFF

Remote I/O plug is offline. The port is not being used, not configured in AMP correctly, not turned on with $RMON, or not attached to a 1771 device.

The remote I/O circuitry and connector are integral parts of the wiring board in the 9/440 system module. Figure 5A.11 shows the remote I/O connector mounted on the 9/440 wiring board. Wire connections for the remote I/O communications are made through the TB4 NODE ADAPT connector. Connect the wires for remote I/O as shown in the following figure. Refer to your 1771 I/O documentation for details on making remote I/O connections. Figure 8.20 Remote I/O Connector in System Module

9/440 System Module

Remote I/O Plug RIO2

RIO1

SHLD

Blue Shield Clear

TB4

8-28

Open Cover

Page 462

Section 8 Communication Interface

9/440 Remote I/O LED Assuming you have: made all necessary remote I/O communication connections on your 1771 I/O network configured your remote I/O port for the remote I/O network in AMP written PAL to set $RMON true during the first PAL foreground execution, and to handle input and output words ($RMI1 -- $RMI8 inputs to PAL and $RMO1 -- $RMO8 outputs from PAL.) CNC Processor Board

Front of System Module

Serial Port A

R--I/O LED

8.10 MMS Ethernet Communications

Video

You are ready to start receiving and transmitting remote I/O information. An LED is provided on the 9/440 CNC processor board and is visible from the bottom of the system module. As remote I/O responds to commands, you should see this LED pattern: LED

Status

Description

Green R- I/O LED

ON

Active Link to PLC. This is the normal state when the RIO link is active.

FLASHING

The remote I/O link is active but the PLC is currently in program mode.

OFF

Remote I/O link is offline. The port is not being used, not configured in AMP correctly, not turned on with $RMON, or not attached to a 1771 device.

The 9/260 and 9/290 CNCs have an MMS Etherent communications module available that provide MMS Ethernet services. With this module, the software is pre--installed with a set of default communication settings (modifications to these defaults is performed with Allen-Bradley Station Manager software). A wide range of services are supported that allow you access to PAL and control variables, part program management, CNC status, etc... Details on the MMS Ethernet communications module are provided in a separate 9/Series MMS/Ethernet Communication Module Users Manual (Catalog number 8520-ENETM). Refer to this publication for further details.

8-29

Page 463

Section 8 Communication Interface

8.11 DH+ Communications

The 9/260 and 9/290 CNCs have a DH+ (Data Highway Plus) communications module available that provide DH+ communications. With this module, the 9/Series can communicate to pass/receive data over DH+ with other Allen--Bradley DH+ compatible devices. A wide range of services are supported that allow you access to PAL and part program variables, part program management, CNC status, etc... Details on the DH+ communications module are provided in a separate 9/Series Data Highway Plus Communication Module Users Manual (Catalog number 8520-DHM). Refer to this publication for further details. END OF SECTION

8-30

Page 464

Publication 8520-6.2.8 - August 1998

Page 465

I--2

9/Series, PAL, PLC, SLC 5/03, SLC 5/04, DH+, and INTERCHANGE are trademarks of Allen-Bradley Company, Inc.

Allen-Bradley, a Rockwell Automation Business, has been helping its customers improve productivity and quality for more than 90 years. We design, manufacture and support a broad range of automation products worldwide. They include logic processors, power and motion control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the world’s leading technology companies.

Worldwide representation. Argentina ·Australia ·Austria ·Bahrain ·Belgium ·Brazil ·Bulgaria ·Canada ·Chile ·China, PRC ·Colombia ·Costa Rica ·Croatia ·Cyprus ·Czech Republic · Denmark ·Ecuador ·Egypt ·El Salvador ·Finland ·France ·Germany ·Greece ·Guatemala ·Honduras ·Hong Kong ·Hungary ·Iceland ·India ·Indonesia · Ireland ·Israel ·Italy ·Jamaica ·Japan ·Jordan ·Korea ·Kuwait ·Lebanon ·Malaysia ·Mexico ·Netherlands ·New Zealand ·Norway ·Pakistan ·Peru · Philippines ·Poland ·Portugal ·Puerto Rico ·Qatar ·Romania ·Russia- CIS ·Saudi Arabia ·Singapore ·Slovakia ·Slovenia ·South Africa, Republic ·Spain · Sweden ·Switzerland ·Taiwan ·Thailand ·Turkey ·United Arab Emirates ·United Kingdom ·United States ·Uruguay ·Venezuela ·Yugoslavia

Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444

Publication 8520-6.2.8 - August 1998 Publication 8520-6.2.8 - August 1998

PN176441 Copyright 1998 Allen-Bradley Company, Inc. Printed in USA

Page 466 read from a scan by OCR; it may hold reading errors

O® Rockwell Automation

Allen-Bradley

9/Series Hardware TAB 9

Operator Interface

852061-RMO09A-EN-P - November 2000 PN-176959

Page 467

This page is a scan with no text; see it in the PDF.

Page 468

Section

9A

Operator Interface

9A.0 Section Overview

This section covers the integration of the components that make up the Operator Interface for the 9/Series CNCs. A section is devoted to each of the following components: Operator Panel (Display device and keyboard -- 3 versions) - Mounted Monochrome operator panel - Mounted Color panel (CRT and Flat panel) - Removable operator panel MTB Panel (selector switches and pushbuttons -- 3 versions) - Standard MTB panel with fiber optic connection - LED type Lamp panel with fiber optic connection - LED type Lamp panel with Direct 24 V I/O connection HPG

(Hand pulse generator for manual jogging)

These components work together to enable the machine tool operator to interface with the control. Data entered through the operator panel keyboard, the MTB panel push buttons and switches, and the HPG handwheel is input to the control via the system I/O ring. How the specific components connect and interact with other modules of the control is explained in the following sections.

9A.1 Operator Panel Overview

The operator can edit programs, view system data, perform machine functions, and many other tasks through the operator panel. The operator panel allows an interface to/from the control through: 5 softkeys and 2 page keys a keyboard with 51 alphanumeric, control, and shift keys the display (CRT or TFT) The display terminal can be either a 9--inch monochrome CRT, a 12--inch color CRT, or the 10.4 inch color flat screen TFT. The system installer must set an AMP parameter to select between the color and monochrome displays (the removable operator panel is always a monochrome display, the flat panel is always configured as a color display). The color displays will use all white characters if the AMP parameter is set incorrectly to “monochrome”. A monochrome display will not display any RED characters if AMP is configured for a color panel. This includes ALL of the system emergency messages.

9A-1

Page 469

Section 9A Operator Interface

The monochrome and the color operator panels are powered by the operator panel power supply. It supplies: +12V dc power to the monochrome or color flat panel displays +12 V dc power to the MTB panel I/O module +5V dc power to the keyboard I/O ring interface +5V dc power to the HPGs The operator panel power supply receives power directly from the controls main power supply. The keyboard and softkeys on the operator panel are interfaced into the 9/Series I/O ring through the keyboard I/O interface. Fiber optic cables connect the optical receiver (black) and optical transmitter (red) on the operator panel keyboard I/O ring interface to the I/O ring. For more information on fiber optic cables and connectors refer to page 7B-1. Figure 9A.1 shows the different operator panels.

9A-2

Page 470

Section 9A Operator Interface

Figure 9A.1 Operator Panels

9/SERIES

Monochrome Operator Panel

Removable Operator Panel

Color Operator Panels (CRT and Flat Panel)

9A-3