The text of a manual · part 53 of 91

9/Series CNC Hardware Integration and Maintenance Manual, pages 521 to 530

Pages 521 to 530 of 898

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 8500-1746I

Page 521

--2

Publication 852062- RM009A- EN- P - November 2000 Supercedes Publication 8520--6.2.9 -- August 1997

PN 176959 Copyright 2000 Allen-Bradley Company, Inc. Printed in USA

Page 522 read from a scan by OCR; it may hold reading errors

O® Rockwell Automation

Allen-Bradley

8520-6.2.10 - February 1997

9/Series Hardware TAB 10

I/O Interface

WW QW WO WC

1746 1/0 Adapter

PN-176041

Page 523

4

Page 524

Section

10A

I/O Interface

10A.0 Section Overview

This section covers the devices that provide an I/O interface with the control. I/O devices transmit inputs from external switches, sensors, etc. to the executing PAL program for processing. Outputs originating from the PAL program are transmitted through the I/O devices to external lamps, relays, valves, etc. The I/O devices are connected either directly to the control or through a fiber optic I/O ring that provides serial communication with the control. The devices on the I/O ring convert electrical signals to optical signals for transmission through the I/O ring. These optical signals are converted back to electrical signals at the CPU board for use by the PAL program. This entire process is reversed for outputs originating from the PAL program. The following I/O devices can be installed on the I/O ring: Push-Button MTB Panel I/O Module Digital I/O High--density I/O Module Analog I/O 1746 I/O Ring Adapter 1771 I/O Ring Adapter HPG Operator Panel 1394 Digital Drive In addition, the following I/O devices can be connected directly to the motherboard (it does not transmit through the fiber optic ring): Fast I/O (9/260 and 9/290 only) Remote I/O Port The size of the I/O ring is limited in how many I/O devices it can support. This limitation is imposed to make sure that the I/O data used by PAL is updated within the time period allotted for PAL foreground execution. Refer to the 9/Series CNC 9/230,9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information.

10A-1

Page 525

Section 10A I/O Interface

ATTENTION: When the control faults or loses power, all I/O devices remain in their last state. I/O devices do not automatically reset to an off state. It is the system installers responsibility to make sure that all I/O is in a safe state when a control shut down occurs. 1771 I/O devices have a dip switch on the backplane that determines the shutdown state for I/O in that 1771 I/O chassis when used with a PLC-5 processor. This dip switch does not have any effect when 1771 I/O devices are used with a 9/Series control. Each I/O device requires a specific amount of update time regardless of the number of inputs and outputs actually connected to the device. This is because devices on the I/O ring use Asynchronous Serial Ring Network circuits (referred to as ASRN “chips”) for input and output transmission. These chips are constantly scanned through the fiber optic ring by the control. Table 10A.A lists the number of ASRN “chips” per device and the number of I/O points per device. Important: The total number of ASRN chips allowed on the fiber optic ring is dependent on your processor as shown in Table 10A.B. Exceeding this number creates an E-STOP condition. Since your system scan time is configurable in AMP it is possible to set the system scan time so low that the control will not complete the I/O scan of all the ASRNs in your ring. When this occurs old data may be made available to PAL. On systems with large I/O rings and low system scan times, the PAL flag $RNGS should be used to test if the system has completed the I/O scan and made all the necessary ring I/O updates. Table 10A.A I/O Ring Modules Connectors I/O Ring Modules

10A-2

Number of ASRN Chips

Number of I/O Points

Operator Panel (standard non-portable)

1

1 8-bit Input

Portable Operator Panel Interface Assembly

1

1 8-bit Input

HPG

1

1 6-bit Input

Pushbutton MTB Panel I/O Module

4

44 Digital Inputs; 18 Digital Outputs

Digital I/O

2

20 Digital Inputs; 12 Digital Outputs

High- density I/O Module

6

66 Digital Inputs; 33 Digital Outputs

Analog I/O

2

1 12-bit Analog Input; 1 12-bit Analog Output

1394 Digital Drive

2

21 Digital Inputs (see appendix H for addressing)

1746 24V dc Digital I/O Assembly (S24)

3

32 inputs, 16 outputs

1746 110V ac Digital I/O Assembly (S115)

3

32 Inputs, 16 Outputs

1746 Analog I/O Assembly (SANL)

6

2 analog input channels, 2 analog output channels

Other 1746 or 1771 I/O Chassis see page 10B-10

Depends upon modules used

Page 526

Section 10A I/O Interface

Table 10A.B Max Number of ASRN Chips 9/Series Control

ASRN

9/230

65

9/260

65

9/290

85

9/440

65

ASRN Chip Used by 1746 or 1771 I/O Chassis The number of ASRN chips used by a 1746 or 1771 I/O chassis will vary depending on the chassis size and the number and type of digital/analog I/O cards installed in the chassis. Refer to page 10B-10 for information on calculating the number of ASRN chips used by one of these racks. The number of ASRN “chips” used by the 1746 or 1771 I/O chassis must be added to the total number of ASRN “chips” used by all the I/O devices on the current I/O ring.

10A-3

Page 527

Section 10A I/O Interface

10A.1 Fiber Optics

I/O devices are connected either directly to the control or through a fiber optic I/O ring that provides serial communication with the control. The I/O devices on the I/O ring convert electrical signals to optical signals for transmission through the I/O ring. These optical signals are converted back to electrical signals at the sub processor board for use by the PAL program. This entire process is reversed for outputs originating from the PAL program. Each I/O device connected to the I/O ring has an transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. A typical ring layout is shown below. Figure 10A.1 Typical Layout of a Multiple Device Fiber Optic I/O Ring Operator’s Panel

HPG

MTB Panel

Digital I/O

High--density I/O

10A-4

9/290 Processor

1746 I/O Rack 11386-I

Page 528

Section 10A I/O Interface

The devices on the fiber optic I/O ring convert electrical signals to optical signals for transmission through the I/O ring. These optical signals are converted back to electrical signals at the sub processor board for use by the PAL program. An example of the input process is shown in Figure 10A.2. Figure 10A.2 PAL Fiber Optic Input Process I/O signals converted from optical to electrical

Executing PAL checks for %HOM_SW1 input to be true prior to setting $HMSW.00 true

Other I/O ring devices 1746 I/O Rack I/O name %HOM_SW1 assigned to input labeled A08 on I/O device

I/O signals converted from electrical to optical

Home Switch (typical I/O input element)

Customer supplied I/O power source

11387-I

10A-5

Page 529

Section 10A I/O Interface

This entire process is reversed for outputs originating from the PAL program. An example of the output process is shown in Figure 10A.3. Figure 10A.3 PAL Fiber Optic Output Process PAL signals converted from electrical to optical

Executing PAL checks $ESTOP (from the control) and sets %ES_ALARM true

E-Stop Warning Alarm (typical I/O output element) Customer supplied I/O power source Other I/O ring devices 1746 I/O Rack

I/O name %ES_ALARM assigned to output labeled B12 on I/O device

PAL signals converted from optical to electrical

All I/O devices on the I/O ring must be assigned a position that corresponds to the physical location of that device on the I/O ring. Their corresponding input and output terminals must be assigned variable names. These assignments are listed in the I/O Assignment file.

10A-6

Page 530

Section 10A I/O Interface

10A.1.1 Fiber Optic Ring Device Fault Indicators

Each I/O interface device connected to the I/O ring has a fault indicator (LED) located on it. Some examples of these indicators are shown in the following figure. The fault indicators on the I/O devices will be lit whenever there is a ring communication error. Figure 10A.4 Fiber Optic Interface Device Fault Indicators

Color Operator Panel Rear

Monochrome Operator Panel

Rear

HPG

Keyboard I/O Ring Interface

8500-1746I Digital (or Analog) I/O

1771 I/O Ring Adapter acTIVE ADAPTER FAULT I/O RING FAULT

A01 A02 A03 A04 A05 A06 A07 A08 A09 A10 B01 B02 B03 B04 B05 B06 B07 B08 B09 B10

I/O RING ADAPTER

A11 A12 A13 A14 A15 A16 B11 B12 B13 B14 B15 B16 ALLEN-BRADLEY

Push-button MTB I/O Panel High--density I/O

11389-I

10A-7