Page 531

Section 10A I/O Interface

10A.2 Push-Button MTB Panel I/O Module

The push-button MTB panel I/O module is included with the push-button MTB panel. It can also be purchased separately to interface a custom MTB panel to the control. This module provides 44 inputs and 18 outputs to the I/O ring. The push-button MTB panel I/O module is interfaced with the system I/O ring through fiber optic cables, which are connected to the optical receiver and transmitter on this module. Refer to Appendix A for additional information on fiber optic cables and connectors. Figure 10A.5 shows the external appearance of the push-button MTB panel I/O module. Figure 10A.5 Push-Button MTB Panel I/O Module External Appearance

+12V dc GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2

CN52 I/O ring fault indicator

10A.2.1 Push-Button MTB Panel I/O Module Pin Assignments

Table 10A.C lists the connectors used to connect the push-button MTB panel I/O module to the operator panel power supply and a custom MTB panel. Table 10A.C Push-Button MTB Panel I/O Module Connectors

Connector On MTB I/O Module

Connected To Module Connector

+12V GND

Operator Panel Power Supply (or External Power Supply)

CN51M

Custom MTB Panel

CN52M

+12V BT03 GND

Cable Number

Remark

C28

Input Output

Input Interface Ribbon Cable MTB panel data is sent to the push-button MTB panel I/O module via the input interface ribbon cable. It is then sent to the control via the fiber optic I/O ring. Table 10A.D lists the pin assignments for the input interface ribbon cable for a custom MTB panel. If you are using an Allen-Bradley MTB panel refer to page 9A-30 for the pinouts of this cable. 10A-8

Page 532

Section 10A I/O Interface

Pin Assignments for Use with Custom MTB Panels The connector pins that are reserved for supplying power to the push-button MTB panel I/O module are indicated. Any pins that are not reserved can be assigned to custom MTB panel functions or an external I/O device. Use the blank space beside each pin number to indicate any pin assignments that are made. The pin assignments will have to correspond to the pin assignments of the push-button MTB panel I/O module in the PAL I/O Assignment file. The I/O assignment file will have to be edited if the pin assignments do not correspond. Refer to the 9/Series CNC 9/230,9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information. Table 10A.D Input Interface Cable Pin Assignments for Custom MTB Panels (Connector CN51) Pin No.

MTB Input Functions

1

2

+12V

3

4

+12V

5

6

+12V

7

8

+12V

9

10

+12V

11

12

+12V

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

Pin No.

MTB Input Functions

49

50

51 53

Power Off Power Common

52 Reserved for use with A-B MTB Panels

55

Power On

56

57

E-Stop

58

59

E-Stop Common

60

54

Reset

10A-9

Page 533

Section 10A I/O Interface

Output Interface Ribbon Cable The data from the push-button MTB panel I/O module is sent to the MTB panel via the output interface ribbon cable. Table 10A.E lists the pin assignments for output interface ribbon cable. If you are using an Allen-Bradley MTB panel refer to page 9A-31 for the pinouts of this cable. Pin Assignments for Use with Custom MTB Panels The connector pins that are reserved for grounding are indicated. Any pins that are not reserved can be assigned to a custom MTB panel function or an external I/O device. Use the blank space beside each pin number to indicate any pin assignments that are made.The pin assignments will have to correspond to the pin assignments of the push-button MTB panel I/O module in the PAL I/O Assignment file. The I/O assignment file will have to be edited if the pin assignments do not correspond. Refer to the 9/Series CNC 9/230,9/260, and 9/290 PAL Reference Manual, publication 8520-4.3, for more information.

10A-10

Page 534

Section 10A I/O Interface

Table 10A.E Output Interface Ribbon Cable Pin Assignments (Connects to CN52) Pin No.

Pin No.

MTB Input Functions

1 3

2

GND

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

MTB Input Functions

4

GND

28 Reserved for Use with A-B MTB Panel

29

30

31

32

33

34

35

36

37 39

38 Unused

40

41 Reserved for Use with A-B MTB Panel

42

43

44

45

46

47

48

49 51

50 GND

52

53

54

55

56

57

58

59

60

GND

10A-11

Page 535

Section 10A I/O Interface

Power Source Specifications

10A.2.2 Push-Button MTB Panel I/O Module Specifications

Table 10A.F lists the power requirements for the push-button MTB panel I/O module. Table 10A.F MTB Panel I/O Module Power Requirements Item

Specifications

Rated Input Voltage

12 V dc

Input Voltage Range

11.5 - 13.2 V dc

Power Consumption

1.3A Typ., 2.6A Max.

External Connection

Terminal Block

Input Specifications Table 10A.G lists the input specifications for the circuits that receive the signals from the pushbuttons and the selector switches on the push-button MTB panel. Table 10A.G Push-Button MTB Panel I/O Module Input Specifications Item

Specifications A-B MTB Panel

Custom MTB Panel

Number of Input Points

54

44

Modal Group

19

Discrete I/O

18

Rotary Input

8

Interconnect Group

6

Unused

3

Remark

Total input signals from all switch groups

All MTB Panels Operating Voltage ON OFF

10A-12

11.5 to 13.2 V dc 0-2V dc

Allowable Voltage Drop

Less than .5V dc

For External Device

Input Impedance

2.25 K ohms

Input Current at ON

5mA

Leakage Current at OFF

Less than 1mA

Response

1-22 msec. Includes Digital Filter Time

OFF ® ON, ON ® OFF

Number of Common Points

6 (per 44 inputs)

Internally connected to Power Supply

Fuse

3A

Protects 12V Power Supply

Isolation

Non-Isolated type

Connection

60 Pin flat cable connector (CN51)

With 12V dc Input

Max. Length 1m

Page 536

Section 10A I/O Interface

Figure 10A.6 shows a typical input circuit diagram for the push-button MTB panel I/O module. Figure 10A.6 Push-Button MTB Panel I/O Module Input Circuit Diagram Push-Button MTB Panel

Push-Button MTB Panel I/O Module

CMOS Input

Switch Common

Converted to Optic Signal

Common

Operator Panel

3A AMP fuse Fiber optics

+12V + -

PE dc power supply

11269-I

The MTB I/O module inputs can be energized by a number of different switching devices, provided that the input specifications listed in Table 10A.G are met. Figure 10A.7 shows some typical input device options. Figure 10A.7 Input Device Options for the Rotary MTB Panel I/O Module MTB Panel

Switch or relay contact

MTB Panel

PE

MTB Panel

Semi-conductor switch

Conductive rubber (resistance) switch

PE

MTB Panel

PE

External supply 8.5 to 13.2 V dc

PE 11312-I

10A-13

Page 537

Section 10A I/O Interface

Output Specifications Table 10A.H lists the output specifications of the MTB I/O module. Table 10A.H Push-Button MTB Panel I/O Module Output Specifications Specifications

Item

Remark

A-B MTB Panel

Custom MTB Panel

Number of Output Points

37

18

Modal Group Outputs

19

Non- I/O Outputs

Discrete Outputs

18

I/O Outputs

Output Type

Sink/Source

Totem Pole Driver Output

Output Voltage Range

9.3-13.2V dc

Output Current at ON

Less than 125mA

Output Voltage Drop at ON

Less than 1 V dc

Number of Common Points

22

Isolation

Non-Isolated type

Connection

60 Pin Flat Cable Connector (CN52)

Per Each Output Internally Connected to Power Supply Max. Length 1m

Figure 10A.8 through Figure 10A.9 show typical output circuit diagrams for the push-button MTB panel I/O module. Figure 10A.8 Push-Button MTB Panel I/O Module Output Circuit Diagram

Push-Button MTB Panel I/O Module Push-Button MTB Panel Fiber optics Output Converted from optical to electrical signal

Load

Common

+12V

Common

Operator Panel dc power supply

Important: A protection resistor is not required with this module.

10A-14

Page 538

Section 10A I/O Interface

Important: When an inductive load (a relay, for example) is directly connected to the output circuit, connect a noise suppressor in the circuit, parallel with the load. Figure 10A.9 Output Device Requiring a Noise Suppressor Noise suppressor MTB Panel Fiber optics

Output Load Common

Converted from optical to electrical signal

+12V

MTB Panel I/O Module

Operator Panel

Common dc power supply 11315-I

10A.2.3 Push-Button MTB Panel I/O Module Fiber Optic Connection

Table 10A.I lists the connectors used to make the fiber optic connections to the I/O ring. Each module connected to the system I/O ring has an optical transmitter and receiver. Fiber optic cables connect transmitters to receivers to form the I/O ring. Refer to Appendix A for additional information on fiber optic cables and connectors. Table 10A.I Push-Button MTB Panel I/O Module Fiber Optic Connectors Connector on Rotary MTB Panel I/O Module

Connected To

Remark

OP11 (RED)

Receiver on next module in I/O ring

Output

OP12 (BLacK)

Transmitter on previous module in I/O ring

Input

10A-15

Page 539

Section 10A I/O Interface

10A.2.4 Push-Button MTB Panel I/O Module Node Address Setting

Each push-button MTB panel I/O module must have a unique node address on the I/O ring. The node address corresponds to a unique address assigned to each push-button MTB panel I/O module in the I/O assignment file. The node address is selected by cutting the jumpers located on the push-button MTB panel I/O module. Figure 10A.10 shows the location of the node address jumpers on the MTB I/O module. Figure 10A.10 Push-Button MTB Panel I/O Module Jumper Positions

+12V dc GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2

CN52 I/O ring fault indicator

Set the node address by cutting the jumper(s) on the push-button MTB panel I/O module according to Table 10A.J. Table 10A.J Push-Button MTB Panel I/O Module Node Address Setting Node Address

Jumper

Hexadecimal

Binary

JP1

JP2

00

00

Short

Short

01

01

Short

Open

02

10

Open

Short

03

11

Open

Open

The node address may be any number between 00 and 03. You may have a total of 4 modules with the MTB panel. The same node address can be used for different types of modules, but may not be used more than once for a specific type of module.

10A-16

Page 540

Section 10A I/O Interface

10A.2.5 Setting the Push-Button MTB Panel I/O Module for a Custom MTB Panel

If you are using the push-button MTB panel I/O module with custom MTB panel, you need to set some jumpers. Figure 10A.11 locates and defines the jumpers. Figure 10A.11 Setting the Jumpers on the Push-Button MTB I/O Panel for a Custom MTB Panel

+12V dc GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2

MTB Panel Type Custom Allen-Bradley

CN52

Pins to cover with shorting post

PANEL JPR3

3 and 2 1 and 2

3 2 1 CUSTOM

A-B

10A-17