The text of a manual · part 65 of 91

9/Series CNC Hardware Integration and Maintenance Manual, pages 641 to 650

Pages 641 to 650 of 898

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 8500-1746I

Page 641

Section 13A Connecting 8520 Digital Drive Systems

Figure 13A.5 8520 Digital Servo Amplifier Connectors CNA1 and CNA2, Honda MR-25RMA and Pin Assignments Pin No.

Connection

Pin No.

Connection

17

1

ENABLE

14

PWM_C

10

2

/ENABLE

15

/PWM_C

3

Shield

16

N.C.

4

Shield

17

Ia

5

Shield

18

/Ia

6

STATUS

19

Shield

7

/STATUS

20

Shield

8

N.C.

21

Shield

9

N.C.

22

Ib

10

PWM_A

23

/Ib

11

/PWM_A

24

N.C.

12

PWM_B

25

N.C.

13

/PWM_B

25 16 9 1 11285-I

Table 13A.G 2AX-D Servo Amplifier Terminal Block TB2 Terminal Assignments Term. No. Connection

Term. No. Connection

1

3f200v/230v-f1

8

Motor 1-fC

2

3f200v/230v-f2

9

Motor 2-fA

3

3f200v/230v-f3

10

Motor 2-fB

4

1f200v/230v-1f-1

11

Motor 2-fC

5

1f200v/230v-1f-2

12

Motor F Ground -1 and Shield

6

Motor 1-fA

13

Motor F Ground-2 and Shield

7

Motor 1-fB

Table 13A.H 2AX-D Servo Amplifier Terminal Block TB2 Terminal Assignments Term. No.

Connection

1

DC+

2

DC-

3

External

13A-7

Page 642

Section 13A Connecting 8520 Digital Drive Systems

Table 13A.I 2AX-D Servo Amplifier Terminal Block TB3 Terminal Assignments Term. No.

Connection

1

SYSTEM READY (Contact Output)

2

SYSTEM READY (Contact Input)

Typically TB3 is used as a relay in your E-STOP string. Terminal 1 and Terminal 2 is an open connection when the drive is in a fault condition and a closed connection when the drive is operating correctly. Table 13A.J System Ready Contact Ratings DC

AC up to 24V max. up to 1.4 A up to 30 Watts max.

up to 230V max. up to 1.4 A up to 30 Watts max.

Table 13A.K 2AX-D Servo Amplifier Terminal Block TB4 Terminal Assignments Term. No.

Connection

1

TSW1-1 (For Motor 1)

2

TSW1-2 (For Motor 1)

3

TSW2-1 (For Motor 2)

4

TSW2-2 (For Motor 2)

Important: Terminal block TB4 is an optional connector that provides a convenient connection to the thermal overload switches of the servo amplifier. This terminal block is typically used to interface the thermal overload switches with PAL or the system E-STOP string. The servo amplifier operates normally without any external connections to terminal block TB4.

13A-8

Page 643

Section 13A Connecting 8520 Digital Drive Systems

13A.2.3 3AX-D Servo Amplifier Connectors and Pin Assignments

Figure 13A.6 shows and lists the 3AX-D (3 axis) 8520 digital servo amplifier connectors and terminal blocks. Figure 13A.6 3AX-D Servo Amplifier Connectors and Terminal Blocks

TB2

CNA2 CNA1

CNA3 TB3 TB1 TB4

Circuit breaker

Connector on 3AX-D Amplifier

Connected To

Mating Connector

CNA1

3-axis Digital Servo Module

CN2/CN3/CN4

CNA2

3-axis Digital Servo Module

CN2/CN3/CN4

CNA3

3-axis Digital Servo Module

CN2/CN3/CN4

CNA1

4-axis Digital Servo Module

J1/J2,/J3 /J4

CNA2

4-axis Digital Servo Module

J1/J2,/J3 /J4

CNA3

4-axis Digital Servo Module

J1/J2,/J3 /J4

TB1

Power Source and Motors

TB2

External Shunt Resistor

TB3

System Ready on E-STOP String

TB4

Thermal Switches on Motors

11287-I

Figure 13A.7 8520 Digital Servo Amplifier Connectors CNA1, CNA2 and CNA3,Honda MR-25RMA and Pin Assignments Pin No.

Connection

Pin No.

Connection

17

1

ENABLE

14

PWM_C

10

2

/ENABLE

15

/PWM_C

3

Shield

16

N.C.

4

Shield

17

Ia

5

Shield

18

/Ia

6

STATUS

19

Shield

7

/STATUS

20

Shield

8

N.C.

21

Shield

9

N.C.

22

Ib

10

PWM_A

23

/Ib

11

/PWM_A

24

N.C.

12

PWM_B

25

N.C.

13

/PWM_B

25 16 9

1 11285-I

13A-9

Page 644

Section 13A Connecting 8520 Digital Drive Systems

Table 13A.L 3AX-D Servo Amplifier Terminal Block TB1 Terminal Assignments Term. No.

Connection

Term. No.

Connection

1

3f200v/230v-f1

10

Motor 2-fA

2

3f200v/230v-f2

11

Motor 2-fB

3

3f200v/230v-f3

12

Motor 2-fC

4

1f200v/230v-1f-1

13

Motor 2-F Ground and Shield

5

1f200v/230v-1f-2

14

Motor 3-fA

6

Motor 1-fA

15

Motor 3-fB

7

Motor 1-fB

16

Motor 3-fC

8

Motor 1-fC

17

Motor 3-F Ground and Shield

9

Motor 1-F Ground and Shield

Table 13A.M 3AX-D Servo Amplifier Terminal Block TB2 Terminal Assignments Term. No.

Connection

1

DC+

2

DC-

3

Shunt

4

External

Table 13A.N 3AX-D Servo Amplifier Terminal Block TB3 Terminal Assignments Term. No.

Connection

1

SYSTEM READY (Contact Output)

2

SYSTEM READY (Contact Input)

Typically TB3 is used as a relay in your E-STOP string. Terminal 1 and Terminal 2 is in a closed connection when the drive is operating correctly and in an open connection when the drive is in a fault condition. Table 13A.O System Ready Contact Ratings

13A-10

DC

AC up to 24V max. up to 1.4 A up to 30 Watts max.

up to 230V max. up to 1.4 A up to 30 Watts max.

Page 645

Section 13A Connecting 8520 Digital Drive Systems

Table 13A.P 3AX-D Servo Amplifier Terminal Block TB4 Terminal Assignments Term. No.

Connection

1

TSW1-1 (For Motor 1)

2

TSW1-2 (For Motor 1)

3

TSW2-1 (For Motor 2)

4

TSW2-2 (For Motor 2)

5

TSW3-1 (For Motor 3)

6

TSW3-2 (For Motor 3)

Important: Terminal block TB4 is an optional connector that provides a convenient connection to the thermal overload switches of the servo amplifier. This terminal block is typically used to interface the thermal overload switches with PAL or the system E-STOP string. The servo amplifier operates normally without any external connections to terminal block TB4.

13A.3 Selecting an A-B 1389 Transformer for 8520 Digital Servo Amplifiers

This section gives you the information you need to determine which A-B 1389 transformer to use with your application. Its also gives the dimensions of each type of A-B 1389 transformer. Important: The 9/230, 9/260, and 9/290 8520 digital servo amplifier is compatible only with an Allen-Bradley 1389 transformer. Table 13A.A provides the formulas you need to size the type of transformer for the application.

13A-11

Page 646

Section 13A Connecting 8520 Digital Drive Systems

Table 13A.A Formulas for Determining Transformer Size If you are using a machine tool application with:

Use this formula to calculate the minimum transformer KVA

Varying loads on the motor

Number of Axes

Machine Tool Duty

(Machine Tool Duty)

1

KW (Largest Motor) x 0.43 + 0.2

2

KW (Largest Motor) x 0.61 + 0.4

3

KW (Largest Motor) x 0.86 + 0.6

4

KW (Largest Motor) x 1.28 + 0.8

5

KW (Largest Motor) x 1.82 + 1.0

6

KW (Largest Motor) x 2.60 + 1.2

Constant acceleration and deceleration

Number of Axes

Rapid Accel/Decel Duty

(Rapid Accel/Decel Duty)

1

KW (Largest Motor) x 0.60 + 0.2

2

KW (Largest Motor) x 0.85 + 0.4

3

KW (Largest Motor) x 1.20 + 0.6

4

KW (Largest Motor) x 1.80 + 0.8

5

KW (Largest Motor) x 2.50 + 1.0

6

KW (Largest Motor) x 3.50 + 1.2

Motors that perform continuously at or near peak capacity

Number of Axes

Continuous Duty

(Continuous Duty)

All

KW (Total of All Motors) x 1.2 + 1.0

If you are using 8520 digital servo amplifiers, select a transformer from this list of Allen-Bradley 1389 transformers. Base your selection on the calculated minimum transformer KVA rating such that the selected transformer’s KVA rating is equal to or larger than the calculated value: Catalog Number

Rating (KVA)

Primary Voltage and Frequency

1389-T015DA

1.5

240/480V ac, 3 f60Hz

1389-T035DA

3.5

1389-T050DA

5.0

1389-T100DA

10.0

1389-T125DA

12.5

1391-TA2

NEMA 1 Transformer Enclosure

The dimensions of the Allen-Bradley 1389 transformers are shown in Figure 13A.8 and Figure 13A.9.

13A-12

Page 647

Section 13A Connecting 8520 Digital Drive Systems

Figure 13A.8 Allen-Bradley 1389 Transformer Dimensions mm (in) Slot 0.22R B max.

13.5 (0.53) 11.2 ref. (0.44)

D

E

C max.

A max. 11195-I

Table 13A.B Allen-Bradley 1389 Transformer Dimensions mm (in.) 1389-

A

B

C

D

E

Weight

T015DA

228 mm (9 in)

254 mm (10 in)

330 mm (13 in)

127 mm (5 in)

79 mm (3.10 in)

12.7 kg (28 lbs)

T035DA

279 mm (11 in)

279 mm (11 in)

356 mm (14 in)

152 mm (6 in)

114 mm (4.5 in)

27.2 kg (60 lbs)

T050DA

279 mm (11 in)

279 mm (11 in)

356 mm (14 in)

152 mm (6 in)

133 mm (5.25 in)

34.0 kg (75 lbs)

T100DA

305 mm (12 in)

317 mm (12.5 in)

406 mm (16 in)

203 mm (8 in)

149 mm (5.85 in)

50.8 kg (112 lbs)

T125DA

305 mm (12 in)

317 mm (12.5 in)

406 mm (16 in)

203 mm (8 in)

143 mm (5.63 in)

59.5 kg (131 lbs)

Figure 13A.9 Allen-Bradley 1389 Transformer Dimensions 469.9 (18.50)

355.6 (14.00)

Front

Side

431.8 (17.00)

419.1 (16.50)

340.8 (12.00) 11196-I

13A-13

Page 648

Section 13A Connecting 8520 Digital Drive Systems

13A.4 8520 Digital Servo Amplifier Fault Indicators

This section discusses faults and how they are detected on the 8520 digital servo amplifier.

System Ready Faults The system checks that the servo amplifier is ready using two methods: System Ready Connector (TB3) The System Ready (on TB3) contact makes sure that the control board of the servo amplifier is ready, the power circuit of the DC bus is ready, and the system relay is closed. Table 13A.C System Ready Contact Ratings DC

AC

24V dc @ 1.4 A (max. 30 W)

230V ac @ 1.4 A (max. 30 W)

Axis status output (CNA1, CNA2, and CNA3)

The Axis status output contact is connected to the servo module and is checked by the servo module’s CPU on a per axis basis. If this contact is not active, the servo module recognizes that the amplifier is in a fault condition and sends the message “SERVO AMPLIFIER FAULT” sent to the control. This is pre-wired through servo cable CN20.

LED Indicators Table 13A.D through Table 13A.F lists the symbol, indication, and color of the 8520 digital servo amplifier fault and ready status indicators (note the LED indicators are numbered on the 3AX-D servo amplifier). Table 13A.D 1AX-D (1 axis) Servo Amplifier Indicators TB2

Symbol

13A-14

Fault or Ready Indication

Color

OT

Over Temperature

Red

UV

Bus Undervoltage

Yellow

OC

Over Current

Red

AXF

Axis 1 Fault

Red

RDY

System Ready

Green

OV

Bus Overvoltage

Red

CVF

Control Voltage Fault

Red

EAX1

Axis 1 Enable

Green

Location of LEDs CNA1 Circuit breaker

TB3 TB1 TB4

Page 649

Section 13A Connecting 8520 Digital Drive Systems

Table 13A.E 2AX-D (2 axis) Servo Amplifier Indicators Symbol (block 1)

Fault or Ready Indication

Color

CVF

Control Voltage Fault

Red

RDY

System Ready

Green

UV

Bus Undervoltage

Yellow

OT

Over Temperature

Red

OV

Bus Overvoltage

Red

AX1F

Axis 1 Fault

Red

AX2F

Axis 2 Fault

Red

OC

Over Current

Red

Symbol (block 2)

Fault or Ready Indication

TB2

Location of block 1 LEDs

Color

Location of block 2 LEDs

CNA2 TB3 TB1

CNA1

EAX1

Axis 1 Enable

Green

EAX2

Axis 2 Enable

Green

TB4

Circuit breaker

Table 13A.F 3AX-D (3 axis) Servo Amplifier Indicators Symbol

Fault or Ready Indication

Color

RDY

System Ready

Green

OT

Over Temperature

Red

OV

Bus Overvoltage

Red

UV

Bus Undervoltage

Yellow

CVF

Control Voltage Fault

Red

OC

Over Current

Red

AX1F

Axis 1 Fault

Red

AX2F

Axis 2 Fault

Red

AX3F

Axis 3 Fault

Red

EAX1

Axis 1 Enable

Green

EAX2

Axis 2 Enable

Green

EAX3

Axis 3 Enable

Green

TB2

Location of LEDs CNA2

CNA3 TB3

CNA1

TB1 TB4

Circuit breaker

13A-15

Page 650

Section 13A Connecting 8520 Digital Drive Systems

13A.5 8520 Digital Servo Amplifier Jumper Settings

Table 13A.G through Table 13A.L list the 8520 digital servo amplifier jumper settings. These jumpers are used to configure the 8520 digital servo amplifier to supply 200% or 300% of the motor rated current, enable or disable the servo motors, latch or unlatch the bus under voltage fault detector, and select the internal or external shunt resistor. ATTENTION: Incorrect jumper settings can cause damage to the servo motors and/or servo amplifiers.

Table 13A.G 1AX-D (1 axis) Servo Amplifier Jumper Settings Axis 1 - - CNA1

J1

J2

J3

J4

J7

J8

J9

J10

Motor Rated Current 200%

300%

1.3

1.3

2.6

2.6

3.9

3.9

5.2

5.2

6.5

6.5

7.8

7.8

9.1

9.1

10.4

10.4

11.8

11.8

13.1

13.1

14.4

>AMP Limit

15.7

>AMP Limit

17.0

>AMP Limit

18.3

>AMP Limit

19.6

>AMP Limit

20.9

>AMP Limit

·

· ·

·

·

·

·

·

· · ·

·

· ·

·

·

·

· ·

· ·

·

·

·

· · ·

· ·

·

·

· ·

·

·

·

·

·

·

·

·

·

· ·

· · ·

· ·

·

·

· ·

·

·

·

·

·

·

·

·

·

· ·

“· ” Denotes jumper short

For 200% of motor rated current, the following jumpers are shorted: - AXIS 1: J5, J6, J11, J12 For 300% of motor rated current, the following jumpers are open: - AXIS 1: J5, J6, J11, J12

13A-16