The text of a manual · part 65 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 641 to 650
Pages 641 to 650 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 641
Section 13A Connecting 8520 Digital Drive Systems
Figure 13A.5 8520 Digital Servo Amplifier Connectors CNA1 and CNA2, Honda MR-25RMA and Pin Assignments Pin No.
Connection
Pin No.
Connection
17
1
ENABLE
14
PWM_C
10
2
/ENABLE
15
/PWM_C
3
Shield
16
N.C.
4
Shield
17
Ia
5
Shield
18
/Ia
6
STATUS
19
Shield
7
/STATUS
20
Shield
8
N.C.
21
Shield
9
N.C.
22
Ib
10
PWM_A
23
/Ib
11
/PWM_A
24
N.C.
12
PWM_B
25
N.C.
13
/PWM_B
25 16 9 1 11285-I
Table 13A.G 2AX-D Servo Amplifier Terminal Block TB2 Terminal Assignments Term. No. Connection
Term. No. Connection
1
3f200v/230v-f1
8
Motor 1-fC
2
3f200v/230v-f2
9
Motor 2-fA
3
3f200v/230v-f3
10
Motor 2-fB
4
1f200v/230v-1f-1
11
Motor 2-fC
5
1f200v/230v-1f-2
12
Motor F Ground -1 and Shield
6
Motor 1-fA
13
Motor F Ground-2 and Shield
7
Motor 1-fB
Table 13A.H 2AX-D Servo Amplifier Terminal Block TB2 Terminal Assignments Term. No.
Connection
1
DC+
2
DC-
3
External
13A-7
Page 642
Section 13A Connecting 8520 Digital Drive Systems
Table 13A.I 2AX-D Servo Amplifier Terminal Block TB3 Terminal Assignments Term. No.
Connection
1
SYSTEM READY (Contact Output)
2
SYSTEM READY (Contact Input)
Typically TB3 is used as a relay in your E-STOP string. Terminal 1 and Terminal 2 is an open connection when the drive is in a fault condition and a closed connection when the drive is operating correctly. Table 13A.J System Ready Contact Ratings DC
AC up to 24V max. up to 1.4 A up to 30 Watts max.
up to 230V max. up to 1.4 A up to 30 Watts max.
Table 13A.K 2AX-D Servo Amplifier Terminal Block TB4 Terminal Assignments Term. No.
Connection
1
TSW1-1 (For Motor 1)
2
TSW1-2 (For Motor 1)
3
TSW2-1 (For Motor 2)
4
TSW2-2 (For Motor 2)
Important: Terminal block TB4 is an optional connector that provides a convenient connection to the thermal overload switches of the servo amplifier. This terminal block is typically used to interface the thermal overload switches with PAL or the system E-STOP string. The servo amplifier operates normally without any external connections to terminal block TB4.
13A-8
Page 643
Section 13A Connecting 8520 Digital Drive Systems
13A.2.3 3AX-D Servo Amplifier Connectors and Pin Assignments
Figure 13A.6 shows and lists the 3AX-D (3 axis) 8520 digital servo amplifier connectors and terminal blocks. Figure 13A.6 3AX-D Servo Amplifier Connectors and Terminal Blocks
TB2
CNA2 CNA1
CNA3 TB3 TB1 TB4
Circuit breaker
Connector on 3AX-D Amplifier
Connected To
Mating Connector
CNA1
3-axis Digital Servo Module
CN2/CN3/CN4
CNA2
3-axis Digital Servo Module
CN2/CN3/CN4
CNA3
3-axis Digital Servo Module
CN2/CN3/CN4
CNA1
4-axis Digital Servo Module
J1/J2,/J3 /J4
CNA2
4-axis Digital Servo Module
J1/J2,/J3 /J4
CNA3
4-axis Digital Servo Module
J1/J2,/J3 /J4
TB1
Power Source and Motors
TB2
External Shunt Resistor
TB3
System Ready on E-STOP String
TB4
Thermal Switches on Motors
11287-I
Figure 13A.7 8520 Digital Servo Amplifier Connectors CNA1, CNA2 and CNA3,Honda MR-25RMA and Pin Assignments Pin No.
Connection
Pin No.
Connection
17
1
ENABLE
14
PWM_C
10
2
/ENABLE
15
/PWM_C
3
Shield
16
N.C.
4
Shield
17
Ia
5
Shield
18
/Ia
6
STATUS
19
Shield
7
/STATUS
20
Shield
8
N.C.
21
Shield
9
N.C.
22
Ib
10
PWM_A
23
/Ib
11
/PWM_A
24
N.C.
12
PWM_B
25
N.C.
13
/PWM_B
25 16 9
1 11285-I
13A-9
Page 644
Section 13A Connecting 8520 Digital Drive Systems
Table 13A.L 3AX-D Servo Amplifier Terminal Block TB1 Terminal Assignments Term. No.
Connection
Term. No.
Connection
1
3f200v/230v-f1
10
Motor 2-fA
2
3f200v/230v-f2
11
Motor 2-fB
3
3f200v/230v-f3
12
Motor 2-fC
4
1f200v/230v-1f-1
13
Motor 2-F Ground and Shield
5
1f200v/230v-1f-2
14
Motor 3-fA
6
Motor 1-fA
15
Motor 3-fB
7
Motor 1-fB
16
Motor 3-fC
8
Motor 1-fC
17
Motor 3-F Ground and Shield
9
Motor 1-F Ground and Shield
Table 13A.M 3AX-D Servo Amplifier Terminal Block TB2 Terminal Assignments Term. No.
Connection
1
DC+
2
DC-
3
Shunt
4
External
Table 13A.N 3AX-D Servo Amplifier Terminal Block TB3 Terminal Assignments Term. No.
Connection
1
SYSTEM READY (Contact Output)
2
SYSTEM READY (Contact Input)
Typically TB3 is used as a relay in your E-STOP string. Terminal 1 and Terminal 2 is in a closed connection when the drive is operating correctly and in an open connection when the drive is in a fault condition. Table 13A.O System Ready Contact Ratings
13A-10
DC
AC up to 24V max. up to 1.4 A up to 30 Watts max.
up to 230V max. up to 1.4 A up to 30 Watts max.
Page 645
Section 13A Connecting 8520 Digital Drive Systems
Table 13A.P 3AX-D Servo Amplifier Terminal Block TB4 Terminal Assignments Term. No.
Connection
1
TSW1-1 (For Motor 1)
2
TSW1-2 (For Motor 1)
3
TSW2-1 (For Motor 2)
4
TSW2-2 (For Motor 2)
5
TSW3-1 (For Motor 3)
6
TSW3-2 (For Motor 3)
Important: Terminal block TB4 is an optional connector that provides a convenient connection to the thermal overload switches of the servo amplifier. This terminal block is typically used to interface the thermal overload switches with PAL or the system E-STOP string. The servo amplifier operates normally without any external connections to terminal block TB4.
13A.3 Selecting an A-B 1389 Transformer for 8520 Digital Servo Amplifiers
This section gives you the information you need to determine which A-B 1389 transformer to use with your application. Its also gives the dimensions of each type of A-B 1389 transformer. Important: The 9/230, 9/260, and 9/290 8520 digital servo amplifier is compatible only with an Allen-Bradley 1389 transformer. Table 13A.A provides the formulas you need to size the type of transformer for the application.
13A-11
Page 646
Section 13A Connecting 8520 Digital Drive Systems
Table 13A.A Formulas for Determining Transformer Size If you are using a machine tool application with:
Use this formula to calculate the minimum transformer KVA
Varying loads on the motor
Number of Axes
Machine Tool Duty
(Machine Tool Duty)
1
KW (Largest Motor) x 0.43 + 0.2
2
KW (Largest Motor) x 0.61 + 0.4
3
KW (Largest Motor) x 0.86 + 0.6
4
KW (Largest Motor) x 1.28 + 0.8
5
KW (Largest Motor) x 1.82 + 1.0
6
KW (Largest Motor) x 2.60 + 1.2
Constant acceleration and deceleration
Number of Axes
Rapid Accel/Decel Duty
(Rapid Accel/Decel Duty)
1
KW (Largest Motor) x 0.60 + 0.2
2
KW (Largest Motor) x 0.85 + 0.4
3
KW (Largest Motor) x 1.20 + 0.6
4
KW (Largest Motor) x 1.80 + 0.8
5
KW (Largest Motor) x 2.50 + 1.0
6
KW (Largest Motor) x 3.50 + 1.2
Motors that perform continuously at or near peak capacity
Number of Axes
Continuous Duty
(Continuous Duty)
All
KW (Total of All Motors) x 1.2 + 1.0
If you are using 8520 digital servo amplifiers, select a transformer from this list of Allen-Bradley 1389 transformers. Base your selection on the calculated minimum transformer KVA rating such that the selected transformer’s KVA rating is equal to or larger than the calculated value: Catalog Number
Rating (KVA)
Primary Voltage and Frequency
1389-T015DA
1.5
240/480V ac, 3 f60Hz
1389-T035DA
3.5
1389-T050DA
5.0
1389-T100DA
10.0
1389-T125DA
12.5
1391-TA2
NEMA 1 Transformer Enclosure
The dimensions of the Allen-Bradley 1389 transformers are shown in Figure 13A.8 and Figure 13A.9.
13A-12
Page 647
Section 13A Connecting 8520 Digital Drive Systems
Figure 13A.8 Allen-Bradley 1389 Transformer Dimensions mm (in) Slot 0.22R B max.
13.5 (0.53) 11.2 ref. (0.44)
D
E
C max.
A max. 11195-I
Table 13A.B Allen-Bradley 1389 Transformer Dimensions mm (in.) 1389-
A
B
C
D
E
Weight
T015DA
228 mm (9 in)
254 mm (10 in)
330 mm (13 in)
127 mm (5 in)
79 mm (3.10 in)
12.7 kg (28 lbs)
T035DA
279 mm (11 in)
279 mm (11 in)
356 mm (14 in)
152 mm (6 in)
114 mm (4.5 in)
27.2 kg (60 lbs)
T050DA
279 mm (11 in)
279 mm (11 in)
356 mm (14 in)
152 mm (6 in)
133 mm (5.25 in)
34.0 kg (75 lbs)
T100DA
305 mm (12 in)
317 mm (12.5 in)
406 mm (16 in)
203 mm (8 in)
149 mm (5.85 in)
50.8 kg (112 lbs)
T125DA
305 mm (12 in)
317 mm (12.5 in)
406 mm (16 in)
203 mm (8 in)
143 mm (5.63 in)
59.5 kg (131 lbs)
Figure 13A.9 Allen-Bradley 1389 Transformer Dimensions 469.9 (18.50)
355.6 (14.00)
Front
Side
431.8 (17.00)
419.1 (16.50)
340.8 (12.00) 11196-I
13A-13
Page 648
Section 13A Connecting 8520 Digital Drive Systems
13A.4 8520 Digital Servo Amplifier Fault Indicators
This section discusses faults and how they are detected on the 8520 digital servo amplifier.
System Ready Faults The system checks that the servo amplifier is ready using two methods: System Ready Connector (TB3) The System Ready (on TB3) contact makes sure that the control board of the servo amplifier is ready, the power circuit of the DC bus is ready, and the system relay is closed. Table 13A.C System Ready Contact Ratings DC
AC
24V dc @ 1.4 A (max. 30 W)
230V ac @ 1.4 A (max. 30 W)
Axis status output (CNA1, CNA2, and CNA3)
The Axis status output contact is connected to the servo module and is checked by the servo module’s CPU on a per axis basis. If this contact is not active, the servo module recognizes that the amplifier is in a fault condition and sends the message “SERVO AMPLIFIER FAULT” sent to the control. This is pre-wired through servo cable CN20.
LED Indicators Table 13A.D through Table 13A.F lists the symbol, indication, and color of the 8520 digital servo amplifier fault and ready status indicators (note the LED indicators are numbered on the 3AX-D servo amplifier). Table 13A.D 1AX-D (1 axis) Servo Amplifier Indicators TB2
Symbol
13A-14
Fault or Ready Indication
Color
OT
Over Temperature
Red
UV
Bus Undervoltage
Yellow
OC
Over Current
Red
AXF
Axis 1 Fault
Red
RDY
System Ready
Green
OV
Bus Overvoltage
Red
CVF
Control Voltage Fault
Red
EAX1
Axis 1 Enable
Green
Location of LEDs CNA1 Circuit breaker
TB3 TB1 TB4
Page 649
Section 13A Connecting 8520 Digital Drive Systems
Table 13A.E 2AX-D (2 axis) Servo Amplifier Indicators Symbol (block 1)
Fault or Ready Indication
Color
CVF
Control Voltage Fault
Red
RDY
System Ready
Green
UV
Bus Undervoltage
Yellow
OT
Over Temperature
Red
OV
Bus Overvoltage
Red
AX1F
Axis 1 Fault
Red
AX2F
Axis 2 Fault
Red
OC
Over Current
Red
Symbol (block 2)
Fault or Ready Indication
TB2
Location of block 1 LEDs
Color
Location of block 2 LEDs
CNA2 TB3 TB1
CNA1
EAX1
Axis 1 Enable
Green
EAX2
Axis 2 Enable
Green
TB4
Circuit breaker
Table 13A.F 3AX-D (3 axis) Servo Amplifier Indicators Symbol
Fault or Ready Indication
Color
RDY
System Ready
Green
OT
Over Temperature
Red
OV
Bus Overvoltage
Red
UV
Bus Undervoltage
Yellow
CVF
Control Voltage Fault
Red
OC
Over Current
Red
AX1F
Axis 1 Fault
Red
AX2F
Axis 2 Fault
Red
AX3F
Axis 3 Fault
Red
EAX1
Axis 1 Enable
Green
EAX2
Axis 2 Enable
Green
EAX3
Axis 3 Enable
Green
TB2
Location of LEDs CNA2
CNA3 TB3
CNA1
TB1 TB4
Circuit breaker
13A-15
Page 650
Section 13A Connecting 8520 Digital Drive Systems
13A.5 8520 Digital Servo Amplifier Jumper Settings
Table 13A.G through Table 13A.L list the 8520 digital servo amplifier jumper settings. These jumpers are used to configure the 8520 digital servo amplifier to supply 200% or 300% of the motor rated current, enable or disable the servo motors, latch or unlatch the bus under voltage fault detector, and select the internal or external shunt resistor. ATTENTION: Incorrect jumper settings can cause damage to the servo motors and/or servo amplifiers.
Table 13A.G 1AX-D (1 axis) Servo Amplifier Jumper Settings Axis 1 - - CNA1
J1
J2
J3
J4
J7
J8
J9
J10
Motor Rated Current 200%
300%
1.3
1.3
2.6
2.6
3.9
3.9
5.2
5.2
6.5
6.5
7.8
7.8
9.1
9.1
10.4
10.4
11.8
11.8
13.1
13.1
14.4
>AMP Limit
15.7
>AMP Limit
17.0
>AMP Limit
18.3
>AMP Limit
19.6
>AMP Limit
20.9
>AMP Limit
·
· ·
·
·
·
·
·
· · ·
·
· ·
·
·
·
· ·
· ·
·
·
·
· · ·
· ·
·
·
· ·
·
·
·
·
·
·
·
·
·
· ·
· · ·
· ·
·
·
· ·
·
·
·
·
·
·
·
·
·
· ·
“· ” Denotes jumper short
For 200% of motor rated current, the following jumpers are shorted: - AXIS 1: J5, J6, J11, J12 For 300% of motor rated current, the following jumpers are open: - AXIS 1: J5, J6, J11, J12