Page 661
Section 13A Connecting 8520 Digital Drive Systems
13A.8.2 8500 Digital Servo Motor Connector and Pin Assignments
The 8500 digital servo motor leads must be connected as shown below. The servo motor rotation, as viewed from the shaft end, will depend on the value of the SIGN OF FEEDBACK AMP parameter. Refer to the 9/260-9/290 AMP Reference Manual, publication 8520-6.4, for more information. Important: The A series 8500 digital servo motor connector (without brake) is slightly smaller than the B series servo motor connector (without brake). The pin layout of these connectors is the same. Figure 13A.2 lists the pin assignments for the 8500 digital servo motor connector without brake. Figure 13A.2 A and B Series 8500 Digital Servo Motor Connector Pin Assignments (without brake)
A
F G
E
B
D
C
Pin
Signal
Pin
Signal
A
PHASE A (U)
E
Thermal Protector
B
PHASE B (V)
F
Thermal Protector
C
PHASE C (W)
G
D
Ground and Shield
-
Figure 13A.3 shows the pin layout for the A series 8500 digital servo motor connector with brake. Figure 13A.3 A Series 8500 digital Servo Motor Connector Pin Assignments (with brake) Pin
G
H
A
I
B
F E
D
C
Signal
Pin
Signal
A
-
F
Phase A (U)
B
Phase C (W)
G
Thermal Protector
C
Brake Terminal
H
Thermal Protector
D
Brake Terminal
I
Phase B (V)
E
Ground and Shield
Important: The A series 8500 digital servo motor connector (with brake) is slightly smaller and its pin layout is different than the B series 8500 digital servo motor connector (with brake). 13A-27
Page 662
Section 13A Connecting 8520 Digital Drive Systems
Figure 13A.3 lists the pin assignments for the A series 8500 digital servo motor connector with brake. Figure 13A.4 shows the pin layout and pin assignments for the B series 8500 digital servo motor connector with brake. Figure 13A.4 B Series 8500 Digital Servo Motor Connector and Pin Assignments (with brake)
A
B
C
E
F
D G
H
13A.9 Feedback Devices
I
Pin
Signal
Pin
Signal
A
Thermal Protector
F
Phase C (W)
B
Thermal Protector
G
Ground and Shield
C
-
H
Brake Terminal
D
Phase A (U)
I
Brake Terminal
E
Phase B (V)
Each servo motor is equipped with a feedback device that is mounted on the end of the motor that is opposite the shaft end. This feedback device can be either an absolute or an incremental encoder. The servo module supplies these encoders with their required +5V power supply. Each servo motor may also be equipped with a second feedback device for greater accuracy for positioning feedback. This second feedback device is normally mounted directly to the moving axis member to avoid inaccuracies caused by the motor gearing and drive components. When a second feedback device is used the motor mounted encoder must remain and is used for velocity feedback as well as motor commutation. The spindle motor can also be equipped with a feedback device. This feedback device must be an incremental encoder with A quad B format. The servo module can supply the spindle encoder with +5V or +15V power.
13A-28
Page 663
Section 13A Connecting 8520 Digital Drive Systems
Table 13A.Q lists the servo encoder specifications. Table 13A.Q Servo Encoder Specifications Absolute Encoder
Incremental Encoder
Number of Pulse
8192 pulse/rev
6000 pulse/rev
Number of Multi-turning
±99999 turns
Resolution
8192 ´4 = 32768 counts/rev
6000 ´4 = 24000 counts/rev
Supply Voltage
+5V (+10%, -1%)
+5V (+10%, -1%)
Battery Backup Voltage
2.9V to 4.5V
N/A
Weight
500 g
500 g
Incremental Encoders Incremental encoders provide coarse axis position feedback to the servo module. These encoders also provide U, V, and W motor phase signals for use in motor commutation until the first marker is detected. After the first marker is detected, the servo module determines incremental axis position from the A, B, and C signals which are output by the encoder. After initial power-up, the control must determine motor phasing by finding the encoder marker. Until this marker is found, phasing is estimated using the U, V, and W phase signals. This limits motor power to approximately 85% of maximum. After the first marker is detected, the exact electrical position is known. Since precise commutation is now possible, full power is possible. An axis homing cycle is required to establish axis position after the motor is phased. Once axis position is established, axis position feedback is transmitted back to the servo module in an A quad B format with marker. This feedback transmission takes place on an incremental basis. ATTENTION: Do not adjust encoder alignment. Commutation requires the encoder marker to be aligned with the windings of the servo motor. This alignment process is done during the mounting of the incremental or absolute encoder to the servo motor.
13A-29
Page 664
Section 13A Connecting 8520 Digital Drive Systems
Absolute Encoders Absolute encoders are an “intelligent” feedback device that provide absolute axis position feedback to the servo module. These encoders incorporate a turns counter register and an absolute single turn encoder. The turns counter register holds the number of turns the motor has made since the motor was last homed. The absolute single turn encoder holds the number of pulses encountered, since the marker was last detected to the present position. The servo module requests position data from the absolute encoder after power up. The values contained in the turns counter register and the single turn encoder are sent to the servo module on the A channel of the encoder signal cable. These values are used by the servo module to calculate the absolute axis position. Once the absolute axis position is determined, the absolute encoder transmits axis position feedback just like an incremental encoder. Precise commutation is possible immediately after power up when using the absolute encoder. Motor winding position is determined using the data provided by the absolute single turn encoder. The absolute encoder is supplied with battery backup. This allows the absolute encoder to retain the absolute position of an axis even after power to the control is turned off. This eliminates the need to home axes every time the control is turned on, and also provides a means for limited recovery from a power failure during machining operations. The battery power originates from the batteries plugged into the servo module. Even if battery backup fails, or the encoder cable is temporarily disconnected, the encoder will still maintain position data for up to 24 hours. This also allows for battery replacement without loss of data. When an encoder other than the standard incremental or absolute encoder provides feedback to the servo module, typically the spindle feedback device, the maximum encoder channel frequency will have to be determined. The following formula is used to calculate the maximum encoder channel frequency: 5 x 10 Maximum Encoder Channel Frequency =
360 90-Eq
Where: 5 x 106 = Control’s Feedback Clock Frequency EQ = Encoder Quadrature Error in Degrees 1.15 = Feedback Clock Safety Factor
13A-30
6 x 1.15
Page 665
Section 13A Connecting 8520 Digital Drive Systems
This value is then compared to the actual A channel frequency of the encoder which is determined by the following formula: (Lines/Rev.) x (Max. Operating RPM) x (min./60sec.)
As long as the actual encoder A channel frequency does not exceed the maximum encoder channel frequency calculated above, the servo module should process the encoder feedback data without a quadrature fault.
13A.9.1 Incremental Encoder Feedback Interface
Figure 13A.5 shows the interface between the 8500 digital servo module and servo motors with incremental encoders. Figure 13A.5 Incremental Encoder to 8520 Digital Servo Module Interface Feedback device (incremental encoder)
Servo module or 9/230 CNC
Channel signals (A, B, Z, U, V, W) Power supply (+5V dc)
Servo Connector
Servo motor 1
Servo Connector
Servo motor 2
Servo Connector
Servo motor 3
Analog Out
11092-I
Figure 13A.6 shows the connector and pin assignments used to interface the incremental encoder with the 8520 digital servo module. Figure 13A.6 Incremental Encoder Feedback Connector and Pin Assignments Incremental Encoder A
M L
T
K
H
C
P S
J
B
N
D
R G
E F
Pin
Signal
Pin
Signal
A
A Channel Output
K
U Channel Output 2
B
/A Channel Output
L
/U Channel Output 2
C
B Channel Output
M
V Channel Output 2
D
/B Channel Output
N
/V Channel Output 2
E
Z Channel Output 1
P
W Channel Output 2
F
/Z Channel Output 1
R
/W Channel Output 2
G
0V
S
----------------
H
+5V dc
T
----------------
J
Frame Ground
-
----------------
Connector Type: Cannon MS3102A20-29P Signal Output Circuit: Differential Line Driver 1 The Z channel output is used for the marker signal. 2 The U, V, and W channels are used for motor phasing only
13A-31
Page 666
Section 13A Connecting 8520 Digital Drive Systems
13A.9.2 Absolute Encoder Feedback Interface
Figure 13A.7 shows the interface between the 8520 digital servo module and the 8500 digital servo motors with absolute encoders. Figure 13A.7 Absolute Encoder to 8520 Digital Servo Module Interface Feedback device (Absolute encoder)
Servo module or 9/230 CNC
Channel signals (A, B, Z)
Servo Connector
Power supply (+5V dc) Battery (+V dc)
Servo motor 1
Servo motor 2
Servo Connector
Servo motor 3
Servo Connector
Battery Connector
Battery
11093-I
Figure 13A.8 shows the connector and lists the pin assignments used to interface the absolute encoder with the 8520 digital servo module. Figure 13A.8 Absolute Encoder Feedback Connector and Pin Assignments Absolute Encoder A
M L
B
N T
C
P
K
D S
J
R E
H
G
F
Pin
Signal
Pin
Signal
A
A Channel Output
K
----------------
B
/A Channel Output
L
----------------
C
B Channel Output
M
----------------
D
/B Channel Output
N
----------------
E
Z Channel Output 1
P
----------------
F
/Z Channel Output 1
R
Encoder Reset Pin
G
0V
S
0V (battery)
H
5V (power supply)
T
+V (battery)
J
Frame Ground
-
----------------
Connector Type: Cannon MS3102A20-29P Signal Output Circuit: Differential Line Driver 1 The Z channel output is used for the marker signal
13A-32
Page 667
Section 13A Connecting 8520 Digital Drive Systems
13A.9.3 Resetting Absolute Encoders on an 8500 Digital Servo Motor
The turns counter register of an absolute encoder can be reset to zero at system start up or if the absolute encoder’s battery backup has failed.
Resetting an Absolute Encoder on the 9/230 At the control: 1.
Move the axis that the absolute encoder is configured for in AMP to the desired zero coordinate position for that axis.
2.
Turn OFF the control and the main ac power switch. ATTENTION: Never adjust the control unless the main AC disconnect switch is open (off) and locked.
3.
Disconnect the battery that supplies battery backup to the absolute encoder being reset.
4.
Determine whether it is easier to disconnect and access connectors at the servomotor or at the control.
If accessing connectors at the 8500 digital servo motor: a.
Remove the cable that is connected to the absolute encoder to be reset.
b.
At the encoder, use a jumper to short pin R to pin S of the absolute encoder for at least 2 minutes. A
M L
B
N T
C
P
K
D S
J
R E
H
G
F
13A-33
Page 668
Section 13A Connecting 8520 Digital Drive Systems
If accessing connectors at the control: a.
Disconnect the absolute encoder signal cable from the servo connector on the control (J1, J2, or J3).
b.
At the cable, use a jumper to short pin 16 to pin 34 (which connect to pins S and R of the absolute encoder) for at least 2 minutes. 15 30 44
1 16 31
After shorting the pins together for the required time: 1.
Make sure the control is OFF.
2.
Reconnect the encoder cable to the control.
3.
Make sure the battery that supplies battery backup to the absolute encoders is good and reconnect it. ATTENTION: Battery power must be supplied to the absolute encoders prior to turning the control “ON”. Power turn-on without first connecting the absolute encoder battery may result in a “Servo AMP Error.” The control remains in E-STOP and E-STOP reset is ignored. To recover from this condition, follow the procedure for resetting absolute encoders.
4.
Leave the motor connected to the backup battery through the feedback cable for at least 1 second before turning the control ON.
The axis is then ready to be homed.
13A-34
Page 669
Section 13A Connecting 8520 Digital Drive Systems
Resetting an Absolute Encoder on the 9/260 and 9/920 Important: The following procedure is no necessary if you are using distance--coded markers or a Stegmann feedback device. At the control: 1.
Move the axis that the absolute encoder is configured for in AMP to the desired zero coordinate position for that axis.
2.
Turn OFF the control and the main ac power switch. ATTENTION: Never adjust the control unless the main AC disconnect switch is open (off) and locked.
At the servo module: 1.
Disconnect the battery that supplies battery backup to the absolute encoder being reset.
2.
Determine whether it is easier to disconnect and access connectors at the servomotor or at the servo module.
If accessing connectors at the 8500 digital servo motor: a.
Remove the cable that is connected to the absolute encoder to be reset.
b.
At the encoder, use a jumper to short pin R to pin S of the absolute encoder for at least 2 minutes. A
M L
B
N T
C
P
K
D S
J
R E
H
G
F
11294-I
13A-35
Page 670
Section 13A Connecting 8520 Digital Drive Systems
If accessing connectors at the 8520 digital servo module: a.
Disconnect the absolute encoder signal cable from the encoder feedback port on the servo module (CN5, CN6, or CN7).
b.
At the cable, use a jumper to short pin 12 to pin 1 (which connect to pins S and R of the absolute encoder) for at least 2 minutes. 1
2 8
14
3 9
15
16
4
5
6
7
10
11
12
13
17
18
19
20
11295-I
After shorting the pins together for the required time: 1.
Make sure the control is OFF.
2.
Reconnect the encoder cable to the control.
3.
Make sure the battery that supplies battery backup to the absolute encoders is good and reconnect it. ATTENTION: Battery power must be supplied to the absolute encoders prior to turning the control “ON”. Power turn-on without first connecting the absolute encoder battery may result in a “Servo AMP Error.” The control remains in E-STOP and E-STOP reset is ignored. To recover from this condition, follow the procedure for resetting absolute encoders.
4.
Leave the motor connected to the backup battery through the feedback cable for at least 1 second before turning the control ON.
The axis is then ready to be homed.
13A-36