Page 721
Section 15A Troubleshooting the Control
Display Preset Pressing the {DISPLY PRESET} softkey displays the preset values assigned to the timer. The value just above the timer element shows the default preset value assigned to the timer when PAL was originally written. The actual preset value (since the preset can be modified with a --(PUT)-command) is shown just below the timer element. Typically both these preset values are the same. (softkey level4) SEARCH FORWRD REVRSE ADJUST TYPE SEARCH SEARCH VIEW DISPLY DISPLY TIME PRESET
The softkey of the current mode being displayed for timers is shown in reverse video.
15A.2.6 Using the Search Monitor Hotkey [SHIFT] + {® }
This feature of the search monitor utility is designed to allow you to quickly switch between most 9/Series screens and the search monitor utility. Using this feature of search monitor, you can jump directly from your current screen to the search monitor and return quickly. This is performed with a hotkey. Use the search monitor hotkey as follows: 1.
Select the screen to view using the normal softkey path.
2.
You can now jump between the selected screen and the search monitor utility using the hotkey sequence which consists of [SHIFT] + {® } keys simultaneously (hold the shift and press the “more” softkey). Each time you press the hotkey, the search monitor utility will toggle between the search monitor screen and the selected screen.
Refer to the accessing the search monitor utility on page 15A-4 for details on how the search monitor information is interpreted and other search monitor restrictions. Important: You can not use the [DISP SELECT] key to select displays when the search monitor utility is active. Additionally you can not use the search monitor hotkey if you have the [DISP SELECT] keys active. If you need to use the display select functions you must select the display prior to entering any of the search monitor screens.
15A-11
Page 722
Section 15A Troubleshooting The Control
If you have designed custom screens through PAL (PAL display pages), you can not use the hotkey to jump to and from the search monitor utility from these screens. The search monitor can also be password protected to prevent unauthorized access. Protecting the search monitor utility with password protection disables not only the softkey access to the utility, but the hotkey access as well. If however you password protect the System Suport softkey, access to the search monitor utility is still available using the hotkey. Password protecting System Suport only prevents softkey access to the search monitor utility. Refer to your 9/Series Operation and Programming manual for details on password protection.
15A.3 Setup Diagnostics
This section defines the setup diagnostic functions available to assist with integrating the control to the machine tool. The diagnostics can be run any time the control is powered up and the fiber optic ring is correctly connected. The diagnostic functions are used to check and monitor all I/O devices. It can also be used to monitor individual axis parameters such as following error, torque, and others. To access the control’s diagostic functions: 1.
Press the {SYSTEM SUPORT} softkey. (softkey level 1) PRGRAM OFFSET MACRO MANAGE PARAM
QUICK CHECK
FRONT PANEL
SWITCH LANG
ERROR PASSMESAGE WORD
SYSTEM SUPORT
If the control determines (through password identification) that the current user is allowed access, then the {MONITOR} softkey appears on the second softkey level. If this softkey does not appear, refer to the password and/or access control section of your operation and programming manual. 2.
Press the {MONITOR} softkey. (softkey level 2) PRGRAM MANAGE
15A-12
AMP
DEVICE MONISETUP TOR
TIME PARTS
Page 723
Section 15A Troubleshooting the Control
The diagnostic menu softkeys that will appear after pressing the {MONITOR} softkey are shown below. (softkey level 3) RING I/O
15A.4 I/O Ring Diagnostics
REMOTE I/O
FAST I/O
AXIS SERIAL MONTOR I/O
When the {RING I/O} softkey is pressed on the Main Diagnostics Menu screen, the Ring I/O screen will appear. At the top of the screen is the message “USE CURSOR FOR SELECTION”, followed by “RING I/O” to identify the screen. Figure 15A.1 Ring I/O Diagnostics Menu Screen
USE CURSOR FOR SELECTION RING I/O DEVICE NAME DEVICE NO. OPERATOR PANEL ANALOG I/O HIGH DENSITY I/O DIGITAL I/O HPG MTB PANEL I/O 1746 I/O DIGITAL I/O 1746 I/O 1746 I/O 1771 I/O ANALOG I/O HPG 1394 Drive
DISPLY
SETUP MODE
00 00 01 01 00 01 01 02 02 03 01 01 02 00
RECOVR RECOVR ENABLE DISABL
Figure 15A.1 is an example of a Ring I/O screen with a relatively large number of different devices. The devices resident on the I/O ring are displayed in the order that they are physically connected on the ring. One screen displays up to 14 devices. If more than 14 devices are connected to the I/O Ring, press and hold the [SHIFT] key and press the [DOWN-ARROW] key to display another page of I/O Ring devices. 15A-13
Page 724
Section 15A Troubleshooting The Control
Displayed to the right of the device is the device number. Assigning device numbers is explained starting on page 10A-1. Different types of I/O devices can have the same device number, however, when more than one of the same type of device is resident on the I/O Ring, each one must have a unique device number. A device can be selected for diagnostic viewing by using the up or down cursor keys on the operator panel keyboard. If the cursor down key is pressed while the cursor is on the bottom line, the next page of devices is displayed (if more devices exist). Pressing the {DISPLY} softkey after the desired device has been selected, will result in an I/O status screen being displayed, which may be used to monitor the selected device. The {RECVRY --DISABLE} and {RECVRY --ENABLE} softkeys determine how the I/O ring will operate if the data integrity checks indicate a bad set of data from the ring. {RECVRY --ENABLE} : This is the Power Turn On mode. When active, the control will try to RECOVER by re--sending / re--reading the ring data. If the remains for a fixed number of retrys, an E--STOP is generated. After the E--stop is generated the control CONTINUES to re--try. This may result in the ring recovering after the E--stop and error message are generated. While this fault tolerent operation is normally good, it makes trouble shooting of an intermittent I/O ring difficult. {RECVRY --DISABLE} : This mode of ring operation can be selected for diagnostic purposes. When active, the control will not try to recover when a fault in the I/O ring data integrity is detected. It will immediately cause an E--STOP and do no retrys of the ring data. This allows the faulty Ring device to be more easily identified.
15A.4.1 Digital I/O
15A-14
If a Digital I/O device is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the Digital I/O Diagnostics screen appears. Figure 15A.2 is an example of this screen.
Page 725
Section 15A Troubleshooting the Control
Figure 15A.2 Digital I/O Diagnostics Screen
DIGITAL I/O DEVICE NO. 02
SETUP MODE ON =
IN A 01 02 03 04 05 06 07 08 09 10 IN B 01 02 03 04 05 06 07 08 09 10 OUT A 11 12 13 14 15 16 OUT B 11 12 13 14 15 16
The device number of the selected Digital I/O appears under the “DIGITAL I/O” heading. This will be a decimal number from 00 to 63. This screen displays the inputs and outputs that correspond to the terminal numbers on the Digital I/O. These are IN A (1 through 10), IN B (1 through 10), OUT A (11 through 16) and OUT B (11 through 16). If an input or output is “ON”, its terminal number appears in inverse video. This is a real time display, and its response is limited only by delays in screen updates. If more than one Digital I/O device is on the I/O Ring, a diagnostics screen for each of these devices can be displayed. To display a diagnostics screen for the next digital I/O on the ring, press and hold the [SHIFT] key and press the [DOWN-ARROW] key. Pressing the exit softkey (up arrow) at any time displays the Ring I/O Menu screen.
15A.4.2 High Density I/O
If a High Density I/O device is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the High Density I/O Diagnostics screen appears. Figure 15A.3 is an example of this screen.
15A-15
Page 726
Section 15A Troubleshooting The Control
Figure 15A.3 High Density I/O Diagnostics Screen
HIGH DENSITY I/O DEVICE NO. 01 IN
SETUP MODE ON =
CN1 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 PW PW PW PW CN2 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 PW PW PW PW
OUT CN3 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 NC
The device number of the selected High Density I/O device appears under the “HIGH DENSITY I/O” heading. This will be a decimal number from 00 to 63. This screen displays the inputs and outputs that correspond to the pin numbers listed for the various connectors on the High Density I/O module. These are IN CN1 (01 through 37), IN CN2 (01 through 37) and OUT CN3 (01 through 37). If an input or output is “ON”, its pin number appears in inverse video. This is a real time display, and its response is limited only by delays in screen updates. The following abbreviated symbols may appear: NC = no connection PW = power connection If more than one High Density I/O device is on the I/O Ring, a diagnostics screen for each of these devices can be displayed. To display a diagnostics screen for the next high density I/O on the ring, press and hold the [SHIFT] key and press the [DOWN-ARROW] key. Pressing the exit softkey (up arrow) at any time displays the Ring I/O Menu screen.
15A-16
Page 727
Section 15A Troubleshooting the Control
15A.4.3 1746 I/O Ring Adapter
If a 1746I I/O Adapter is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the 1746I I/O Adapter Diagnostics screen appears. Since the 1746I I/O Adapter is available in four different configurations, 4--slot Chassis, 7--slot Chassis, 10--slot Chassis, and 13--slot Chassis, there are four possible screens. Examples are shown in Figure 15A.4 and Figure 15A.5. Figure 15A.4 1746 I/O Adapter Diagnostics Screen, 4 Slot Rack
1746 I/O DEVICE NO. 01
SETUP MODE ON =
4 SLOT RACK
1
IN
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
2
IN 00 01 02 03 04 05 06 07 OUT 00 01 02 03 04 05 06 07
3
EMPTY
Figure 15A.5 1746 I/O Adapter Diagnostics Screen, 4 Slot Rack 1746 I/O DEVICE NO. 02
4 SLOT RACk
SETUP MODE ON =
1 OUT 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 2 IN 00 01 02 03 04 05 06 07 3 ANALOG IN 0000H 0.000V 0.000MA ANALOG IN 8000H -10.000V -20.000MA ANALOG OUT 7FFFH 10.000V 20.000MA ANALOG OUT 0CCDH 1.000V 4.000MA
15A-17
Page 728
Section 15A Troubleshooting The Control
The device number of the selected 1746 I/O Adapter device appears under the “1746 I/O ADAPTER” heading. This number is selected on the 1746I module using a dip switch (refer to page 10B-4 for details) and used in the I/O assigner in PAL. Following the number is the message indicating whether it is a 4, 7, 10, or 13 slot rack. If the selected device is a 7, 10, or 13 slot rack, two or three screens may be required to display all of the I/O data. When additional screens are available, press and hold the [SHIFT] key and press the [DOWN-ARROW] key to access additional screens with I/O data from the same 1746 I/O Adapter. Cursoring down below the last row on each screen will also access the next screen if it exists. The 1746 I/O Adapter Diagnostic screen displays the inputs and outputs that correspond to the terminal numbers on the 1746 I/O Adapter module. They are listed in rows with each row representing a slot in the rack. If an input or output is “ON”, its terminal number appears in inverse video. If there is no I/O module in a slot, “EMPTY” follows the slot number. This is a real time display, and its response is limited only by delays in screen updates. Values for analog modules are displayed using four lines of the display. If more than one 1746 I/O Adapter is on the I/O Ring, a diagnostics screen for each of these devices can be displayed. To display a diagnostics screen for the next 1746 I/O adapter on the ring, while on the last page of the current 1746 I/O adapter press and hold the [SHIFT] key and press the [DOWN-ARROW] key. Pressing the exit softkey (up arrow) at any time displays the Ring I/O Menu screen.
15A.4.4 1771 I/O Ring Adapter
15A-18
If a 1771 I/O Adapter is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the 1771 I/O Adapter Diagnostics screen appears. Since the 1771 I/O Adapter is available in four different configurations, 4 Slot Rack, 8 Slot Rack, 12 Slot Rack, and 16 Slot Rack, there are four possible screens. Examples are shown in Figure 15A.6 and Figure 15A.7
Page 729
Section 15A Troubleshooting the Control
Figure 15A.6 1771 I/O Adapter Diagnostics Screen, 4 Slot Rack
1771 I/O DEVICE NO. 01
4 SLOT RACK
SETUP MODE ON =
0
IN
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17
1
OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17
2
IN
3
EMPTY
00 01 02 03 04 05 06 07
Figure 15A.7 1771 I/O Adapter Diagnostics Screen, 16 Slot Rack
1771 I/O DEVICE NO. 02 16 SLOT RACK 0 IN 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 1 OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 2 IN 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 3 IN 00 01 02 03 04 05 06 07 4 IN 00 01 02 03 04 05 06 07 5 IN 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 6 EMPTY 7 IN 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 8 IN 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 9 IN 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37
SETUP MODE ON =
15A-19
Page 730
Section 15A Troubleshooting The Control
Figure 15A.7 1771 I/O Adapter Diagnostics Screen, 16 Slot Rack (continued)
1771 I/O DEVICE NO. 02 10 11 12 13 14 15
15A-20
IN
16 SLOT RACK
00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 IN 00 01 02 03 04 05 06 07 OUT 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 IN 00 01 02 03 04 05 06 07 IN 00 01 02 03 04 05 06 07
SETUP MODE ON =