Page 731
Section 15A Troubleshooting the Control
The device number of the selected 1771 I/O Adapter device appears under the “1771 I/O ADAPTER” heading. This will be a decimal number from 00 to 60. Following the number is the message indicating whether it is a 4, 8, 12, or 16 slot rack. If the selected device is a 8, 12, or 16 slot rack, two or three screens may be required to display all of the I/O data. When additional screens are available, press and hold the [SHIFT] key and press the [DOWN-ARROW] key to access additional screens with I/O data from the same 1771 I/O Adapter. Cursoring down below the last row on each screen will also access the next screen if it exists. The 1771 I/O Adapter Diagnostic screen displays the inputs and outputs that correspond to the terminal numbers on the 1771 I/O Adapter module. They are listed in rows with each row representing a slot in the rack. Since there can be 8, 16, or 32 terminals per slot, the 32 terminal slots will require two rows of the display. If an input or output is “ON”, its terminal number appears in inverse video. If there is no I/O module in a slot, “EMPTY” follows the slot number. This is a real time display, and its response is limited only by delays in screen updates. If more than one 1771 I/O Adapter is on the I/O Ring, a diagnostics screen for each of these devices can be displayed. To display a diagnostics screen for the next 1771 I/O adapter on the ring, while on the last page of the current 1771 I/O adapter press and hold the [SHIFT] key and press the [DOWN-ARROW] key. Pressing the exit softkey (up arrow) at any time displays the Ring I/O Menu screen.
15A-21
Page 732
Section 15A Troubleshooting The Control
15A.4.5 MTB Panel I/O Diagnostics Screen
If a MTB Panel I/O device is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the MTB I/O Diagnostics screen appears. Figure 15A.8 is an example of this screen. Figure 15A.8 MTB Panel I/O Diagnostics Screen
MTB PANEL I/O DEVICE NO. 01 IN
01 PW 03 PW 05 PW 07 PW 09 PW 11 PW 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
OUT
01 GD 03 GD 05 GD 07 GD 09 GD 11 GD 13 GD 15 GD 17 18 19 20 21 22 23 24 25 26
SETUP MODE ON =
The device number of the selected MTB Panel I/O device appears under the “MTB PANEL I/O” heading. This will be a decimal number from 00 to 03. This screen displays the input and output pin assignments that correspond to the input and output connectors on the MTB Panel I/O module. If an input or output pin is “ON”, it appears in inverse video. This is a real time display, and its response is limited only by delays in screen updates. The following abbreviated symbols may appear: PW = power connection GD = ground connection If more than one MTB Panel I/O device is on the I/O Ring, a diagnostics screen for each of these devices can be displayed. To display a diagnostics screen for the next MTB panel I/O device on the ring, press and hold the [SHIFT] key and press the [DOWN-ARROW] key. Pressing the exit softkey (up arrow) at any time displays the Ring I/O Menu screen. 15A-22
Page 733
Section 15A Troubleshooting the Control
Using the MTB Panel I/O Diagnostics Screen with the Push-Button MTB Panel The signals from the push-button MTB panel are interpreted differently than those received by the rotary MTB panel. Since the MTB Panel I/O Diagnostics Screen displays only the pins for the rotary MTB panel, you need to use Table 15A.A and Table 15A.B to perform diagnostics on the push-button MTB panel with this screen.
15A-23
Page 734
Section 15A Troubleshooting The Control
Table 15A.A Push-Button MTB Panel Input Interface Ribbon Cable Pin Assignments Function
Pin No.
Gray Code
PAL Device Name
Pin No.
Function
N/A
CN51-1
2
+12V
Gray Code
PAL Device Name
N/A
N/A
1
Cycle Stop
3
Cycle Start
CN51-3
4
+12V
5
Single Block
CN51-5
6
+12V
7
+X
CN51-7
8
+12V
9
+Y
CN51-9
10
+12V
11
+Z
CN51-11
12
+12V
13
+4
CN51-13
14
AUTO a
CN51-34
15
-X
CN51-15
16
MDI b
CN51-32
17
-Y
CN51-17
18
MANUAL
19
-Z
CN51-19
20
INCR a
CN51-30
21
-4
CN51-21
22
CONT b
CN51-28
23
TRVRS
CN51-23
24
HAND
25
F5
CN51-25
26
HOME
27
F6
CN51-27
28
X1 a
CN51-40
29
F1
CN51-29
30
X10 b
CN51-38
31
F2
CN51-31
32
X100 c
CN51-36
33
F3
CN51-33
34
X1000
35
F4
CN51-35
36
X10000
37
Feedrate Override “a” a
CN51-38
37
Rapid Override F1 a
CN51-45
39
Feedrate Override “b” b
CN51-40
39
Rapid Override 25 b
CN51-47
41
Feedrate Override “c” c
CN51-42
41
Spindle Speed Override “d” d
CN51-42
43
Feedrate Override “d” d
CN51-44
43
Spindle Speed Override “c” c
CN51-44
45
Not Used
N/A
N/A
46
Spindle Speed Override “b” b
CN51-46
47
48
Spindle Speed Override “a” a
CN51-48
49
50
Rapid Override 50
51
Power Off
52
Rapid Override 100
53
Power Common
54
CCW a
CN51-49
55
Power On
56
OFF b
CN51-50
57
E-stop
58
CW
59
E-stop Common
60
Reset
15A-24
N/A
Page 735
Section 15A Troubleshooting the Control
Table 15A.B Push-Button MTB Panel Output Interface Ribbon Cable Pin Assignments Pin No.
Function
PAL Device Name
Pin No.
1
Cycle Stop
CN52-1
2
3
Cycle Start
CN52-3
4
5
Single Block
CN52-5
6
7
+X
CN52-7
8
Function
Ground
PAL Device Name N/A
9
+Y
CN52-9
10
11
+Z
CN52-11
12
13
+4
CN52-13
14
15
-X
CN52-15
16
17
-Y
CN52-17
18
F4
CN52-18
19
-Z
CN52-19
20
F3
CN52-20
21
-4
CN52-21
22
F2
CN52-22
23
Trvrs
CN52-23
24
F1
CN52-24
25
F5 Jog Retract
CN52-25
26
F6 Block Retrace
CN52-26
27
Ground
N/A
28
AUTO
29
30
MDI
31
32
MANUAL
33
34
Rapid Override F1
35
36
Rapid Override 25
37
38
Rapid Override 50
39
Not Used
40
Rapid Override 100
41
X1
42
CCW
43
X10
44
OFF
45
X100
46
CW
47
X1000
48
INCR
49
X10000
50
CONT
51
Ground
52
HAND
53
54
HOME
55
56
Ground
57
58
59
60
N/A
15A-25
Page 736
Section 15A Troubleshooting The Control
15A.4.6 Operator Panel Keyboard Diagnostics Screen
If an Operator Panel Keyboard (OPERATOR PANEL) device is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the Operator Panel Keyboard (OPERATOR PANEL) Diagnostics screen appears. Figure 15A.9 is an example of this screen. Figure 15A.9 OPERATOR PANEL Diagnostics Screen OPERATOR PANEL DEVICE NO. 0
SETUP MODE NUMBER 1011000
X
The device numbers of all operator panel devices that are on the I/O Ring will appear under the “OPERATOR PANEL” heading. These may be any decimal numbers from 0 to 3. To the right of the device number is a number that represents the binary output from each of the operator panel keys. This number changes as the operator panel keys are depressed. The symbol of the key that is depressed will be displayed to the right of this number. To verify key actuation, place a volt meter or oscilloscope probes between test points TP1 (GND) and TP2 (KEY_ON) located on the keyboard interface module. A logic high or +5V dc measured between TP1 and TP2 indicates a key actuation.
15A-26
Page 737
Section 15A Troubleshooting the Control
15A.4.7 HPG Diagnostics
If a Hand Pulse Generator (HPG) device is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the HPG Diagnostics screen appears. Figure 15A.10 is an example of this screen. Figure 15A.10 HPG Diagnostics Screen HPG
SETUP MODE
DEVICE NO. 0 1 2
NUMBER 011011 111111 000000
The device numbers of all HPG devices that are on the I/O Ring will appear under the “HPG” heading. These may be any decimal numbers from 00 to 07. To the right of each device number is a number for each of the HPG’s. This is the pulse count value of the pulse counter that counts from 0 to 63 and then rolls over. Even though the number of pulse counts displayed for each HPG is limited to 64, the total pulse count of each HPG, which is stored internally by the system software, is unlimited. Since this is a real time display, its response is limited only by delays in screen updates. Only HPG devices connected to the I/O Ring are displayed on this screen. Pressing the exit softkey (up arrow) at any time displays the Ring I/O Menu screen.
15A-27
Page 738
Section 15A Troubleshooting The Control
15A.4.8 Analog I/O Diagnostics Screen
If an 9/Series Analog I/O device is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the Analog I/O Diagnostics screen appears. Figure 15A.11 is an example of this screen. 1746 Analog I/O devices are discussed on page 15A-17. Figure 15A.11 Analog I/O Diagnostics Screen ANALOG I/O
DEV. INPUT NO. U/B VAL. VOLTAGE 0 B 12C 1.464 1 U 52F 3.238 2 U 82C 5.104 3 B F12 -1.137 6 U 800 5.000 7 B 800 -10.000 8 B 800 -10.000 9 B 800 -10.000 10 B 800 -10.000 11 B 800 -10.000 12 B 800 -10.000
U: 0 TO +10 B: -10 TO +10 OUTPUT U/B VAL. VOLTAGE U 012 0.044 U 830 5.114 B 800 -10.000 U F12 9.419 B 012 0.088 B 012 0.088 B 012 0.088 B 012 0.088 B 012 0.088 B 012 0.088 B 012 0.088
The device numbers for all Analog I/O devices that are on the I/O Ring will appear under the “ANALOG I/O” heading. These will be decimal numbers from 00 to 15. If more than 13 Analog I/O devices are connected to the I/O Ring, press and hold the [SHIFT] key and press the [DOWN-ARROW] key to access the remaining devices. Pressing these keys or cursoring below the last device on the screen will cause the next Analog I/O Diagnostics screen to appear. Each device listed is followed by several columns of diagnostic values. These columns are:
15A-28
U/B
This indicates whether the device is Unipolar (0 to 10 volts) or Bipolar (-10 to 10 volts) as determined by device switch settings.
VAL.
This is the HEX representation of the digital equivalent of the analog voltage level from or to the device.
VOLTAGE
This is the voltage level from or to the device.
Page 739
Section 15A Troubleshooting the Control
These columns are duplicated for INPUT and OUTPUT for each device. The voltage values shown represent real time values with response limited only by delays in screen updates. Pressing the exit softkey (up arrow) at any time displays the Ring I/O Menu screen.
15A.4.9 1394 Drives Diagnostics Screen
If a 1394 Drive is selected on the Ring I/O screen and the {DISPLY} softkey is pressed, the 1394 Drives Diagnostics screen appears. Figure 15A.12 is an example of this screen. 1394 drives are discussed on page 11A-1. Important: This page only applies to 1394 drives that are present on the 9/Series fiber optic I/O ring. It does not apply to 9/440 CNC systems that are integrated into the 1394 drive. Figure 15A.12 1394 Drive Diagnostics Screen
Device Ring Address 1394 DRIVES DEV NO. 00
Axis Module Faults Axis Module Slot Number
System Module Faults
SLOT 1 SLOT 2 SLOT 3 SLOT 4
AXIS MODULE FAULT PWR CRNT VBUS 00 02 03 05 06 07 09 10 11 13 14 15
TEMP 04 08 12 16
SYSTEM MODULE FAULT VHI VLOW GRND 17 18 19
TEMP 20
PHASE 21
Note that the fault is active when the I/O number for that fault is shown in reverse video. The following table lists the axis module and system module faults and gives a description.
15A-29
Page 740
Section 15A Troubleshooting The Control
Faults Axis Module
Description
PWR
The axis module hardware has faulted from an over current condition. The current through the power output transistors is monitored. If the current exceeds a fixed level (greater than 300% of controller rating) this fault will appear. Typical causes are a shorted lead, motor malfunction, or malfunctioning power IGBTs.
CRNT
One of the axis modules of your 1394 drive has been requested to provide too much current. This is typically caused by: Accel/Decel command from the CNC is requiring peak current for an excessive amount of time, the machine friction or inertial/viscous load is excessive, the motor has been improperly sized, a short circuit exists across the drive output terminals, logic supply circuits have malfunctioned, or AC input is incorrectly wired.
VBUS
The DC bus supply was lost to the axis module. Check slider connections/termination strip or there could be a blown link fuse.
TEMP1
The 1394 contains a thermal sensor which senses the internal ambient temperature. Causes could be: that the cabinet ambient temperature is above rating. The machine duty cycle requires an RMS current exceeding the continuous rating of the controller. The airflow access to the 1394 is limited or blocked.
Faults System Module
Description
VHI
The 1394 system module bus voltage exceeds the maximum operating voltage. The DC power bus is continuously monitored. If it exceeds a preset level (810 Vdc), a fault is sensed and the power supply is disabled. This can be caused by an under sized shunt requirement, shunt regulator fuse has blown, the shunt regulator transistor has malfunctioned, the power driver board is malfunctioning and incorrectly sensing the bus voltage, the CNC acc/dec rate is incorrectly set, the input line voltage is excessive, the system inertia is too high causing excessive energy to be returned to the power supply bus, or a vertical axis with insufficient counterbalancing is overdriving the servomotor and causing excessive energy to be returned to the power supply bus.
VLOW
The 1394 system module voltage does not meet the minimum operating voltage. The DC power buss shall activate the under voltage limit when the bus drops to 275 VDC or less. It will clear at 300 Vdc. Typical causes include low voltage on the three phase input.
GRND
The 1394 system module has detected a ground fault. The system generates a ground fault when there is an imbalance in the DC bus of greater than 5A. This drive error can be caused by incorrect wiring (verify motor and ground wiring), motor malfunction, or an axis module IGBT malfunction.
TEMP1
The 1394 contains a thermal sensor which senses the internal ambient temperature. Causes could be: that the cabinet ambient temperature is above rating. The machine duty cycle requires an RMS current exceeding the continuous rating of the controller. The airflow access to the 1394 is limited or blocked.
PHASE
The 1394 system module has detected a loss of one of the input power phases. The three- phase input line is monitored and a fault will be issued when a phase loss is detected. Typical causes include, one or more input line fuses have opened, contactor malfunction, or incorrect wiring.
1 Over Temperature Indicators are for the system module and axis modules only. They do not reflect any motor over temperatures that may occur. Motor thermal switches (if available) should be wired into the E-STOP string.
15A-30