The text of a manual · part 77 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 761 to 770
Pages 761 to 770 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 761
Section 15B Replacement Procedures
6.
Press any key when you have connected the control to your personal computer. After a few minutes the PC displays this screen: Connection established. Device is a 9/290 CNC Downloading required system modules... Module:Boot Directory Revision 1.0 Status: downloaded Module:XLINX Data Revision 1.0 Status: downloaded Module:Main CPU Exec Revision 1.0 Status: downloaded Module:I/O CPU Exec Revision 1.0 Status: downloading (81%)
If you have a 9/230 or 9/260 a similar screen appears that does not include the last message about the I/O CPU. Also, the 9/230 downloads a servo executive. If this screen does not appear, refer to the table at the end of this section for a listing of status and error messages. 7. Control Screen
Once the download is complete: PC Screen
Informative Messages Host Operations Complete. Power Down Control. Disconnect Serial Channel Then Restart the Control.
Error Messages
Connection established. Device is a 9/290 CNC Downloading required system modules... Module: Boot Directory Revision 1.0 Module: XLINX Data Revision 1.0 Module: Main CPU Exec Revision 1.0 Module: I/O CPU Exec Revision 1.0 Download complete. The CNC system is now ready to use.
Status: downloaded Status: downloaded Status: downloaded Status: downloaded
Power down the CNC. Disconnect the RS-232 cable. Then restart the CNC and check the updated system. If there are problems, the update may be retried. Retry update (y/n)?
15B-5
Page 762
Section 15B Replacement Procedures
8.
If error messages appear when you restart the control, perform the appropriate recovery and then type y at the PC prompt. Go on to step 9. If no error messages appear, type n at the PC prompt. This screen appears:
Reinsert disk A into drive A: Strike any key when ready...
When you strike a key, the control update deletes the directory that it created to install the update and returns to the drive prompt:
Removing scratch directory... Update is complete C:\>
9.
When you choose to retry the update, this screen appears:
In order to download the system updates the CNC and PC must first be connected. Power down the CNC. Connect RS-232 cable from CNC port B to PC port COM1 Then restart the CNC. Press a key when ready...
15B-6
Page 763
Section 15B Replacement Procedures
10. When you press a key, the update procedure begins again at step 6.
Error and Status Messages As you use the update utility, the control and your PC display status and when necessary, error messages. The status messages tell you what the control is doing or what it has just done. The utility displays error messages when it cannot complete the update. Table 16.A lists the error messages and recovery steps. Table 16.A Error Messages and Recovery Steps for the Update Utility Messages that Appear on the PC Screen Message
Recovery
Boot directory conflict
Call Allen-Bradley Support Services.
Communication line error detected
Retry at lower baud rate. If that does not work check communication ports and connections. Check config.sys file for proper device driver setup.
Connected to invalid device
Make sure you are connected to a 9/230, 9/260, 9/290, or 9/440, and not a 9/240.
Could not open DF1 protocol on COM1
Retry at lower baud rate. If that does not work check communication ports and connections.
I/O error on file
Check disks to make sure that they have not been damaged.
Module has an invalid checksum
Check disks, communication connections, and flash SIMMs. Retry update.
Not enough RAM available
Add memory to your PC.
System update files are corrupt
Call Allen-Bradley and request a new update utility.
Unable to connect to control
Retry at lower baud rate. If that does not work check communication ports and connections. Check config.sys file for proper device driver setup.
Unable to download
Refer to recovery for the error message on the next line of the display.
Unable to find file
Check the disk in the external drive. Make sure it is an update disk.
Unable to open file
Check the disk in the external drive. Make sure it is an update disk.
Unable to set up communications port
Retry at lower baud rate. If that does not work check communication ports and connections.
Update floppies corrupt: Inconsistent module revision
Call Allen-Bradley and request a new update utility. Messages that Appear on the Control Screen
Message
Recovery
Boot directory is missing
Retry update.
Comm error while processing host request
Retry at lower baud rate. If that does not work check communication ports and connections.
Flash SIMMs are not installed
Install the flash SIMMs onto the CPU board (for 9/260 or 9/290) processor board (9/230).
Flash SIMMs contain invalid data
Retry update.
Flash SIMMs U10 and U14 are empty or missing
Make sure your flash SIMMs are installed in the correct tracks.
Flash SIMM U10 is empty or missing
Make sure your flash SIMMs are installed in the correct tracks.
15B-7
Page 764
Section 15B Replacement Procedures
Flash SIMM U14 is empty or missing
Make sure your flash SIMMs are installed in the correct tracks.
Low voltage on flash sticks
Call Allen-Bradley Support Services.
Module(s) with inconsistent revision level
Retry update. If this does not work, call Allen-Bradley and request a new update utility.
Module(s) with invalid checksum
Retry update.
Unable to write to flash memory
Call Allen-Bradley Support Services.
Unrecoverable error
Call Allen-Bradley Support Services.
15B.2 Replacing the Lithium Battery
The RAM memory on the motherboard stores part programs and tool offsets. This stored data is kept active by battery backup while system power is off. The battery backup, which is supplied by a battery pack (8520-LIBAT) will retain data for approximately six months. The battery backup is tested on power-up and at four-hour intervals while system power is on. If battery voltage drops below the replace-battery reference level during the battery test, the control automatically displays the warning message “REPLACE MEMORY BACKUP BATTERY” on the operator panel. Once the “REPLACE MEMORY BACKUP BATTERY” message is displayed, it is essential that the batteries be replaced to avoid loss of data. If battery voltage drops below the battery-dead reference level during the battery test, the control displays the message “BATTERY FAILURE.” Data in RAM memory will be lost if power to the control is turned “OFF” when the battery is dead. Batteries and battery replacement instructions are included with the battery replacement kit. Before installing new batteries, use a voltmeter to make sure that new battery voltage is higher than 3.5V.
The lithium battery contains heavy metals and must be collected separately from other waste.
15B-8
Page 765
Section 15B Replacement Procedures
To replace the main processor board battery: 1.
Backup up any data (typically part programs, PAL, AMP, tool offsets, axis calibration, etc.) that is resident in RAM memory.
2.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open and locked.
Important: To prevent static discharge, the use of a ground strap is recommended . 3.
Disconnect the old battery pack from the connector on the motherboard.
4.
Loosen the four screws holding the battery pack to the component enclosure.
5.
Replace the old battery pack with a new one and tighten the four screws.
6.
Connect the new battery pack to the connector CN10 on the motherboard.
7.
Turn ON power to the control.
8.
Download the the backed up data to RAM.
15B-9
Page 766
Section 15B Replacement Procedures
15B.3 Replacing the CPU Board on the 9/260 and 9/290
In the case of hardware failure, you may be required to replace the CPU board. When you remove the CPU board from the enclosure, you also must remove the flash memory SIMMs and the shadow RAM SIMMs. To replace the CPU board: 1.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.
2.
If there is a cable connected to the RS 232 port (port A) disconnect it.
3.
Remove the Phillips head screws at the top and bottom of the CPU board’s face panel. Use Figure 15B.1 to locate the screws.
4.
Use a flathead screwdriver to pry the board’s faceplate a few inches from the component enclosure. Use Figure 15B.1 to find the pry point on the faceplate.
Figure 15B.1 Removing the CPU Board from the Component Enclosure on the 9/260 and 9/290 Use a screwdriver at this point to pry the module away from the chassis.
Remove this screw
Remove this screw
15B-10
Page 767
Section 15B Replacement Procedures
5.
With your hands pull the board away completely from the enclosure and lay the board on a clean surface with the SIMMs facing you.
6.
Use Figure 15B.2 to find the release tabs for the flash memory and shadow RAM SIMMs.
Figure 15B.2 Release Tabs on the SIMM modules
Flash Memory SIMMs Shadow RAM SIMMs (on 9/290 only)
19202
7.
Press the raised lever on the left and right tabs at the same time to release the SIMM module. As each SIMM is released, it turns slightly.
8.
Remove all SIMM modules from the board. These modules contain the PAL and AMP information for your control. You may want to label these modules before storing them. You will need to reinstall the modules when you receive the new or repaired CPU board.
9.
When you receive your replacement CPU board, install it into the component enclosure as shown in Figure 15B.3. If you have extended memory, you need to set the jumper shown in Figure 15B.4 before you install the module.
15B-11
Page 768
Section 15B Replacement Procedures
Figure 15B.3 Replacing the CPU Module on the 9/260, and 9/290
Component Enclosure
CPU Module 12592-I
Figure 15B.4 Setting the Extended Memory (EPPS) Battery Jumper
Use only for extended program storrage Faceplate of the CPU Module
Flash memory on SIMMs Bottom Side View
15B-12
P14
P13
P12
Connector to the Motherboard
Place the jumper here if you have extended memory (EPPS). Leave the jumper here if you do not have extended memory (EPPS).
19488
Page 769
Section 15B Replacement Procedures
15B.4 Replacing the Motherboard on the 9/260 and 9/290
In the case of hardware failure,you may be required to replace the motherboard. When you remove the motherboard from the enclosure, you also must remove the software option chip. This chip turns on all the optional features that you purchased with the control. To replace the motherboard: 1.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open and locked.
2.
Remove all connections to the motherboard, including: battery fast I/O I/O ring E-stop wiring video RS-232/RS-422 communications
3.
Remove all modules connected to the motherboard, including: CPU board (see the previous procedure) analog or digital servo modules optional communication modules remote I/O port
15B-13
Page 770
Section 15B Replacement Procedures
4.
Remove the 12 screws shaded in this figure.
These are guideposts for installing the motherboard, not screw locations.
19101
5.
Remove the motherboard from the component enclosure and lay it down on a clean surface with the connectors facing up.
6.
Locate the software option chip with this figure. With a dip extractor, remove the chip from the motherboard. You may want to label it before storing it. When the new or repaired motherboard is received, replace the software option chip. Remove with dip extractor
15B-14