Page 781

Section 15B Replacement Procedures

15B.9 Replacing the Monochrome CRT

To replace the monochrome CRT: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

15B.10 Replacing the Color CRT

2.

Remove the cover on the back of the monochrome operator panel.

3.

Disconnect the cable running from the main power supply to the operator panel power supply.

4.

Disconnect the cable running from the operator panel power supply to the monochrome CRT.

5.

Remove the 4 screws on the sides of the monochrome CRT enclosure.

6.

Slide the monochrome CRT out of the monochrome operator panel enclosure and replace it with a new monochrome CRT.

7.

Replace and tighten the 4 screws, reconnect the cable running from the operator panel power supply to the monochrome CRT, replace the rear cover, then reconnect all additional cables and modules.

To replace the color CRT: 1.

Turn OFF all power to the control. ATTENTION: Make sure that all cables are properly attached to the correct terminals. Failure to do so may result in injury to personnel, or damage to the control or machine.

2.

Remove the cover that covers the rear of the color operator panel.

3.

Disconnect the cable running from the main power supply to the operator panel power supply.

4.

Disconnect the cable running from the color CRT to the operator panel power supply at the molex connector.

15B-25

Page 782

Section 15B Replacement Procedures

15B.11 Replacing the Keyboard Assembly for the Monochrome Operator Panel

5.

Remove the 4 mounting screws on the sides and the 2 mounting screws on the bottom of the color CRT enclosure.

6.

Slide the color CRT out of the color operator panel enclosure and replace it with a new color CRT.

7.

Replace and tighten the 6 mounting screws, replace the rear cover, then reconnect all cables and modules.

To replace the monochrome panel keyboard assembly: 1.

Turn OFF all power to the control. ATTENTION: Make sure that all cables are properly attached to the correct terminals. Failure to do so may result in injury to personnel, or damage to the control or machine.

2.

Disconnect the flat cable running from the keyboard I/O ring interface to the monochrome panel keyboard assembly.

3.

Disconnect the keyboard ground wires, by removing the screws on the keyboard.

4.

Remove the six keyboard mounting nuts on the back of the panel. Install the new keyboard. Important: The CRT mounting screws must be loosened to allow the CRT to be pushed up against the bezel gasket for proper seal when the new keyboard is installed.

5.

15B-26

Move the CRT up against the bezel and tighten the mounting screws.

Page 783

Section 15B Replacement Procedures

15B.12 Replacing the Keyboard Assembly for the Color Operator Panel

To replace the color panel keyboard assembly: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

15B.13 Replacing the I/O Ring Interface for the Keyboard

2.

Disconnect the flat cable running from the keyboard I/O ring interface to the color panel keyboard assembly and ground wires by removing the screws on the keyboard.

3.

Remove the 12 mounting nuts along the back edges of the color panel keyboard assembly.

4.

Remove the color panel keyboard assembly and replace it with a new color panel keyboard assembly.

5.

Replace and tighten the 12 mounting nuts along the back then reconnect the flat cable to the keyboard I/O ring interface and ground wire.

To replace the keyboard I/O ring interface: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Disconnect the cable running from the operator panel power supply to the keyboard I/O ring interface.

3.

Disconnect the flat cable running from the operator panel keyboard to the keyboard I/O ring interface.

4.

Disconnect the fiber optic cables.

5.

Remove the 4 mounting screws which are located at the corners of the keyboard I/O ring interface.

15B-27

Page 784

Section 15B Replacement Procedures

6.

Remove the keyboard I/O ring interface and replace it with a new keyboard I/O ring interface.

7.

Replace and tighten the 4 mounting screws then reconnect all cables.

8.

Set the node address (JP1 and JP2) to match the jumper settings on the old keyboard I/O ring interface. The node address is selected by cutting the jumpers located on the operator panel keyboard I/O ring interface. Figure 15B.6 shows the location of the jumpers.

9.

Set the color or monochrome operator panel jumper (JP3) to match the type of operator panel you have. The center pin of JP3 and the pin labeled COP should be shorted when installed on a color operator panel. The center pin of JP3 and the pin labeled MOP should be shorted when installed on a monochrome operator panel.

Figure 15B.6 Operator Panel Jumper Positions Front

Operator Panel

8520- KBI

JP3 shown configured for color operator panel.

Rear

COP

MOP

JP3

CN19M

JP3

JP1 JP2

The keyboard I/O ring interface board is mounted under the CRT, next to the power supply module on the color operator panel.

15B-28

Page 785

Section 15B Replacement Procedures

15B.14 Replacing the Fuse in the Monochrome CRT

To replace the monochrome CRT fuse: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Remove the cover that covers the rear of the monochrome operator panel.

3.

Remove the fuse from its holder and replace it with a recommended replacement fuse. Refer to Figure 15B.7 for the location of the monochrome CRT fuse. ATTENTION: Use only replacement fuses of the type and rating specified for the monochrome CRT. Improper fuse selection may result in equipment damage.

Figure 15B.7 Location of Monochrome CRT Fuse

Front

Operator Panel

Rear

3A

4.

After replacing the fuse, replace the rear cover of the monochrome operator panel, then turn power ON.

15B-29

Page 786

Section 15B Replacement Procedures

15B.15 Replacing the Fuse in the Color CRT

To replace the color CRT fuse: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Remove the cover that covers the rear of the color operator panel.

3.

Remove the fuse(s) from its holder and replace it with a recommended replacement fuse. Refer to Figure 15B.8 for the location of the color CRT fuses. ATTENTION: Use only replacement fuses of the type and rating specified for the color CRT. Improper fuse selection may result in equipment damage.

Figure 15B.8 Location of Color CRT Fuses

Rear of color monitor

3A

AC H AC L ac power connection

1.2A

4.

15B-30

After replacing the fuse(s), replace the rear cover of the color operator panel, then turn power ON.

Page 787

Section 15B Replacement Procedures

15B.16 Replacing the Power Supply for Monochrome Operator Panel

To replace the operator panel power supply on a monochrome operator panel: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

15B.17 Replacing the Power Supply for the Color Operator Panel

2.

Disconnect the cable running from the main power supply to the operator panel power supply.

3.

Disconnect the cable running from the operator panel power supply to the keyboard I/O ring interface.

4.

Remove the keyboard I/O ring interface.

5.

Disconnect the cables running from the operator panel power supply to the MTB panel and the HPG’s.

6.

Loosen the 4 mounting screws on the operator panel power supply.

7.

Slide the operator panel power supply out of the mount and replace it with a new operator panel power supply.

8.

Tighten the 4 mounting screws on the operator panel power supply then reconnect all cables.

To replace the operator panel power supply on a color operator panel: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Disconnect the cable running from the main power supply to the operator panel power supply.

3.

Disconnect the cable running from the color CRT internal power supply to the operator panel power supply. 15B-31

Page 788

Section 15B Replacement Procedures

15B.18 Replacing the Rotary MTB Panel

4.

Disconnect the cable running from the operator panel power supply to the keyboard I/O ring interface.

5.

Disconnect the cables running from the operator panel power supply to the MTB panel and the HPG’s.

6.

Loosen the 4 mounting screws on the operator panel power supply.

7.

Slide the operator panel power supply out of the mount and replace it with a new operator panel power supply.

8.

Tighten the 4 mounting screws on the operator panel power supply then reconnect all cables.

To replace the rotary MTB panel: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

15B-32

2.

Disconnect the cable running from the operator panel power supply to the power supply terminals on the rotary MTB panel I/O module.

3.

Disconnect the I/O interface cable running from the connector (CN16F) on the sub processor board to the rotary MTB panel.

4.

Disconnect the cable running from the E-Stop terminals of terminal block BT-20 to the E-Stop terminal block BT01 on the motherboard.

5.

Disconnect the cable running from the power ON/OFF terminals of terminal block BT-20 to the ON SW/OFF SW terminals on the main power supply.

6.

Disconnect the fiber optic cables from the MTB panel I/O module.

Page 789

Section 15B Replacement Procedures

7.

Remove the 8 mounting screws along the top and bottom edges of the rotary MTB panel.

C26

+12 V DC GND

CN51

C27

CN52

OP11 (out) I/O ring fault indicator OP12 (in)

8.

15B.19 Replacing the Push-button MTB Panel

JP1 JP2

Replace the rotary MTB panel with a new rotary MTB panel.

To replace the push-button MTB panel: 1.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Disconnect the cable running from the operator panel power supply to the power supply terminals on the push-button MTB panel I/O module.

3.

Disconnect the I/O interface cable running from the connector (CN16F) on the sub processor board to the push-button MTB panel.

4.

Disconnect the cable running from the E-Stop terminals of terminal block BT-20 to the E-Stop terminal block BT01 on the motherboard.

5.

Disconnect the cable running from the power ON/OFF terminals of terminal block BT-20 to the ON SW/OFF SW terminals on the main power supply.

6.

Disconnect the fiber optic cables from the MTB panel I/O module.

15B-33

Page 790

Section 15B Replacement Procedures

7.

Remove the 9 mounting screws along the top and bottom edges of the push-button MTB panel.

+12V DC GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2 CN52

15B.20 Replacing the Push-button Light Bulbs

8.

Replace the push-button MTB panel with a new MTB panel.

9.

Replace and tighten the 9 mounting screws, then reconnect all cables.

To replace the light bulbs in the push-button MTB panel: 1.

Call your A-B sales representative and have them order replacement light bulb, part number 156780 for your digital MTB panel or part number 800M--N16 for your A--B 800 push--button MTB panel from A-B field service.

2.

Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

15B-34

3.

Disconnect the cables from TB1 located on the MTB interface board.

4.

Disconnect the cables from TB20 located on the MTB interface board.

5.

Disconnect the input interface ribbon cable from CN51 and the output interface ribbon cable from CN52.

6.

Disconnect the fiber optic cables from connectors OP11 and OP12.