Page 791
Section 15B Replacement Procedures
7.
Remove the 9 mounting screws along the top and bottom edges of the MTB interface board. TB1 +12V DC GND
CN51
OP12 (in)
OP11 (out)
JPR1 JPR2 CN52
TB20
MTB Interface Board
8.
Remove the interface board to reveal the MTB board that contains the push-buttons.
MTB Board
9.
Use a flat head screwdriver to twist the bulb and its socket out of the panel.
10. Place the replacement bulb into the hole and gently twist the socket into place. Important: Do not over-tighten the light bulbs. 11. Remount the MTB interface board and reconnect the cables and wiring you disconnected in steps 3. through 6.
15B-35
Page 792
Section 15B Replacement Procedures
15B.21 Replacing the Hand Pulse Generator and Interface Board
To replace the Hand Pulse Generator and Interface Board 1.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.
2.
Disconnect the cable running from the operator panel power supply to the HPG interface board.
3.
Disconnect the fiber optic cables.
4.
Remove the screw holding the handle on the HPG interface board then remove the handle.
5.
Disconnect the cable running from the HPG to the HPG interface board.
6.
Remove the 3 nuts on the HPG mounting studs that hold the HPG to the cabinet or front panel.
Important: The HPG interface board is mounted behind the front panel using 2 of the 3 nuts that secure the HPG to the front panel. When the nuts holding the HPG to the front panel are removed, the HPG interface will come off. 7.
If the HPG or HPG interface board is defective, replace it with a new HPG.
8.
Match the setting of the switch assembly on the new HPG interface board to that of the one being replaced as shown below.
9.
Put the HPG back onto the cabinet or front panel.
10. Place the HPG interface board onto two of the mounting studs of the HPG. 11. Tighten the 3 nuts.
15B-36
Page 793
Section 15B Replacement Procedures
12. Reconnect all cables, then place the handle over the HPG interface board and tighten the screw that holds the handle in place. Bottom of HPG
ON 1
2
3
Back of HPG
15B.22 Replacing the Battery Backup for Absolute Encoders on the Servo Module
Important: If incremental encoders are used instead of absolute encoders, the servo module requires no batteries. The digital servo module provides battery backup for the absolute encoder position register. The absolute encoder position register provides position data retention during power loss. The battery backup power originates from the batteries plugged into the servo board at connector CN10. Even if battery backup fails, or the encoder cable is temporarily disconnected, the encoder will still maintain position data for up to 24 hours. This also allows for battery replacement without loss of information. Important: On the 9/230 Digital CNC the battery backup for the absolute encoder originates from the battery on the processor board. This battery is also used for axis data backup. To replace the servo module battery: 1.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.
Important: Wear an ESD wristband to prevent static discharge. 2.
Disconnect the old battery pack from connector CN10 on the 3-axis servo module or connector P3 on the 4-axis servo module.
15B-37
Page 794
Section 15B Replacement Procedures
3.
Loosen the four screws holding the battery pack to the control chassis.
4.
Replace the old battery pack with a new one and tighten the four screws.
5.
Connect the new battery pack to connector CN10 on the 3-axis servo module or connector P3 on the 4-axis servo module.
6.
Turn ON power to the control.
Batteries and battery replacement instructions are included with the battery replacement kit. Before installing new batteries, use a voltage meter to make sure that new battery voltage is higher than 3.5V.
The lithium battery contains heavy metals and must be collected separately from other waste.
15B.23 Replacing the 3-axis Digital Servo Module
This is not available on the 9/230 control. To replace the digital servo module: 1.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open and locked.
Important: The use of a ground strap is recommended to prevent static discharge. 2.
Disconnect all cables that are connected to the servo module.
Important: The control must be “homed” after replacing the servo module. If the servo motors incorporate an absolute encoder, the absolute axis position will be lost. The absolute encoder must be reset after the servo module is replaced. Refer to page 13A-33 for absolute encoder reset procedures. 3.
15B-38
Remove the 4 mounting screws that hold the board rack, which holds the servo module to be replaced, in the component enclosure. Slide the board rack out of the component enclosure board slot.
Page 795
Section 15B Replacement Procedures
4.
If your system has an optional feedback module, remove it as described on page 15B-43.
5.
Remove the 6 mounting screws, shown in Figure 15B.9, which hold the servo module to the board rack.
Figure 15B.9 Servo Module Mounting Screw Locations
CN1 CN11
CN10 CN13 CN8 CN2 CN3 CN4 CN5 CN6 CN7
CN12
CN9
6.
Remove the servo module being replaced and install the new servo module.
7.
Replace and tighten the 6 mounting screws.
8.
If you have an optional feedback module, reinstall it.
9.
Slide the board rack into the the board slot of the component enclosure then replace and tighten the 4 mounting screws.
10. Replace all cables that were disconnected. 11. Turn ON power to the control.
15B-39
Page 796
Section 15B Replacement Procedures
15B.24 Replacing the Digital Servo Amplifier
To replace a digital servo amplifier: 1.
Turn OFF all power to the control and the servo amplifier. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open and locked.
2.
Carefully disconnect and mark all cables that are connected to the servo amplifier.
3.
Loosen but do not remove the 4 mounting screws that hold the servo amplifier to the cabinet.
4.
Grasp the servo amplifier firmly with one hand holding the chassis under connector TB1 and one hand holding the chassis just to the right of TB2.
5.
Carefully slide the servo amplifier up (mounting holes are slotted) and then out.
6.
Install the replacement amplifier by reversing the removal procedure. Grasp it as described in step 4 above and position it over the mounting screws.
7.
Carefully slide it down, making sure all four screws are positioned into the screw slots.
8.
Tighten the four mounting screw securely.
9.
Replace all wires and connectors exactly as they were removed.
10. MATCH JUMPERS on the new servo amplifier to the settings on the amplifier being replaced. Amplifier jumper settings are listed starting on page 13A-16. ATTENTION: Jumper settings configure the amplifier to match the specific application. Failure to match jumper settings on the new servo amplifier may result in damage to the amplifier, servomotors, or machine.
11. Turn ON power to the control and servo amplifier.
15B-40
Page 797
Section 15B Replacement Procedures
15B.25 Replacing the Logic Board on the Digital Servo Amplifier
The logic board(s) is the circuit board(s) mounted directly to the face of the servo amplifier. Generally replacement can be accomplished without removing the servo amplifier from the cabinet. To replace the logic board on a servo amplifier: 1.
Turn OFF all power to the control and the servo amplifier. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open (off) and locked.
Important: The use of a ground strap is recommended to prevent static discharge to any of the sensitive electronic components on the servo amplifier logic board(s). 2.
Carefully label and disconnect all wires and connectors to the logic board(s).
Important: Labeling is essential since some connectors are the same size and could be accidentally interchanged. 3.
Disconnect the chassis ground wire from the logic board(s). If the ground wire is soldered to the logic board, it will have to be disconnected at the chassis, just to the left of TB1.
4.
Remove the screws that secure the logic board(s) to the servo amplifier chassis.
5.
Carefully push the wires and connectors to the side and remove the logic board(s).
6.
Install the replacement board(s) by reversing the removal procedure. First position the board(s) on the chassis and verify that all wires and connectors are accessible.
7.
Install and tighten the screws that secure the logic board(s) to the chassis.
8.
Reconnect all wires and connectors, including the chassis ground wire.
15B-41
Page 798
Section 15B Replacement Procedures
9.
MATCH JUMPERS on the new servo amplifier logic board(s) to the settings on the board(s) being replaced. Amplifier jumper settings are listed starting on page 13A-16. ATTENTION: Jumper settings configure the amplifier to match the specific application. Failure to match jumper settings on the new servo amplifier may result in damage to the amplifier, servomotors, or machine.
10. Turn ON power to the control and servo amplifier.
15B.26 Replacing the Power Section on the Digital Servo Amplifier
The servo amplifier power section includes the entire servo amplifier chassis and all components mounted beneath the servo amplifier logic board. Replacement requires removal of the servo amplifier from the cabinet. To replace the servo amplifier power section on a servo amplifier: 1.
Turn OFF all power to the control and the servo amplifier. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open (off) and locked.
Important: The use of a ground strap is recommended to prevent static discharge to any of the sensitive electronic components on the servo amplifier logic board(s). 2.
Remove the servo amplifier from the cabinet as discussed earlier in this section.
3.
Carefully label and disconnect all wires and connectors to the logic board(s).
Important: Labeling is essential since some connectors are the same size and could be accidentally interchanged. 4.
15B-42
Disconnect the chassis ground wire from the logic board(s). If the ground wire is soldered to the logic board, it will have to be disconnected at the chassis, just to the left of TB1.
Page 799
Section 15B Replacement Procedures
5.
Remove the screws that secure the logic board(s) to the servo amplifier chassis.
6.
Carefully push the wires and connectors to the side and remove the logic board(s).
7.
Install the logic board(s) onto the new servo amplifier power section by reversing the removal procedure. First position the board(s) on the chassis and verify that all wires and connectors are accessible.
8.
Install and tighten the screws that secure the logic board(s) to the chassis.
9.
Reconnect all wires and connectors to the logic board(s) as labeled, including the chassis ground wire.
10. Return the servo amplifier to the cabinet and reconnect it. 11. Turn ON power to the control and servo amplifier.
15B.27 Replacing the Optional Feedback Module
This is not available on the 9/230 control. To replace the optional feedback module: 1.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open and locked.
2.
Remove the servo module next to the optional feedback module.
3.
Disconnect all cables connected to the optional feedback module.
4.
Disconnect the optional feedback module from the servo module.
5.
Replace the optional feedback module with a new one.
6.
Set jumper JP1 on the new optional feedback module to correspond to the setting of jumper JP1 on the old optional feedback module.
7.
Adjust the variable resistors (pots) on the new optional feedback module so they to correspond to the settings of the variable resistors (pots) on the old optional feedback module.
8.
Reconnect all cables that were disconnected.
15B-43
Page 800
Section 15B Replacement Procedures
9.
Reinstall the servo module
10. Turn ON power to the control.
15B.28 Replacing the 3-axis Analog Servo Module (9/260 and 9/290 only)
To replace the analog servo module: 1.
Turn OFF all power to the control. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open and locked.
Important: The use of a ground strap is recommended to prevent static discharge to any of the sensitive electronic components on the servo amplifier logic board(s).
15B-44
2.
Disconnect all cables that are connected to the servo module.
3.
Remove the 4 mounting screws that hold the board rack with the servo module to be replaced, in the component enclosure. Slide the board rack out of the component enclosure board slot.
4.
Remove the 6 mounting screws, shown in Figure 15B.10, which hold the servo module to the board rack.