Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 81 of 91

9/Series CNC Hardware Integration and Maintenance Manual, pages 801 to 810

Pages 801 to 810 of 898

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 8500-1746I

Page 801

Section 15B Replacement Procedures

Figure 15B.10 Analog Servo Module Mounting Screw Locations

TB1

CN1

P2 TB2 P3 J1 J2 J3

15B.29 Replacing the 4-axis Servo Module (9/260 and 9/290 only)

5.

Remove the servo module being replaced and install the new servo module.

6.

Replace and tighten the 6 mounting screws.

7.

Slide the board rack into the the board slot of the component enclosure then replace and tighten the 4 mounting screws.

8.

Replace all cables that were disconnected.

9.

Turn ON power to the control.

To replace the 4-axis servo module: 1.

Turn OFF all power to the control, any peripherals, and servo devices. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open and locked.

15B-45

Page 802

Section 15B Replacement Procedures

Important: The use of a ground strap is recommended to prevent static discharge to any of the sensitive electronic components on the servo amplifier logic board(s). 2.

Disconnect all cables that are connected to the servo module.

Important: For digital systems, the control must be “homed” after replacing the servo module. If the servo motors incorporate an absolute encoder, the absolute axis position will be lost. The absolute encoder must be reset after the servo module is replaced. Refer to page 13A-33 for absolute encoder reset procedures.

15B.30 Replacing an Analog Servo Amplifier

3.

Remove the 4 mounting screws that hold the board rack with the servo module to be replaced, in the component enclosure. Slide the board rack out of the component enclosure board slot.

4.

Remove the 6 mounting screws, shown in Figure 15B.10, which hold the servo module to the board rack.

5.

Remove the servo module being replaced and install the new servo module.

6.

Replace and tighten the 6 mounting screws.

7.

Slide the board rack into the the board slot of the component enclosure then replace and tighten the 4 mounting screws.

8.

Replace all cables that were disconnected.

9.

Turn ON power to the control.

To replace an analog servo amplifier, first read all documentation prepared by the analog servo amplifier’s manufacturer, then: 1.

Turn OFF all power to the control and the servo amplifier. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open (off) and locked.

2.

15B-46

Carefully disconnect and mark all cables that are connected to the servo amplifier.

Page 803

Section 15B Replacement Procedures

3.

Loosen and/or remove the mounting screws that hold the servo amplifier to the cabinet.

4.

Carefully remove the servo amplifier.

5.

Install the replacement amplifier by reversing the removal procedure.

6.

Replace all wires and connectors exactly as they were removed.

7.

MATCH SETTINGS on the new servo amplifier to the settings on the amplifier being replaced. Servo amplifiers may use jumpers, DIP switches, software switches or potentiometers for amplifier configuration. Refer to the literature provided with the servo amplifier. ATTENTION: Amplifier settings configure the amplifier to match the specific application. Failure to match settings on the new servo amplifier may result in damage to the amplifier, servo motors, or machine.

8.

15B.31 Replacing the Rotary MTB Panel I/O Module

Turn ON power to the control and servo amplifier.

To replace the rotary MTB panel I/O module: 1.

Disconnect the cable running from the operator panel power supply or external power source to the power supply terminals. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Disconnect the fiber optic cables.

3.

Disconnect the input and output cables running from the rotary MTB panel I/O module to the rotary MTB panel.

15B-47

Page 804

Section 15B Replacement Procedures

4.

Remove the 5 mounting screws, shown in Figure 15B.11, that connect the rotary MTB panel I/O module to the stand-offs.

Figure 15B.11 Rotary MTB Panel I/O Module Mounting Screw Locations

+12 Vdc GND

CN51

CN52

OP11 (out) I/O ring fault indicator OP12 (in)

JP1 JP2

5.

Replace the old rotary MTB panel I/O module with a new rotary MTB panel I/O module.

6.

Replace and tighten the 5 mounting screws then reconnect all cables.

7.

Set the node address to match the settings on the old rotary MTB panel by cutting the wire jumpers on the new rotary MTB panel I/O module.

Figure 15B.12 Rotary MTB Panel I/O Module Jumper Positions

C26

+12 V DC GND

CN51

OP11 (out) I/O ring fault indicator OP12 (in)

15B-48

JP1 JP2

C27

CN52

Page 805

Section 15B Replacement Procedures

15B.32 Replacing the Push-Button MTB Panel I/O Module

To replace the push-button MTB panel I/O module: 1.

Disconnect the cable running from the operator panel power supply or external power source to the power supply terminals. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Disconnect the fiber optic cables.

3.

Disconnect the input and output cables running from the push-button MTB panel I/O module to the push-button MTB panel.

4.

Remove the 9 mounting screws, shown in Figure 15B.13, that connect the push-button MTB panel I/O module to the stand-offs.

Figure 15B.13 Push-Button MTB Panel I/O Module Mounting Screw Locations

+12V DC GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2 CN52

5.

Replace the old push-button MTB panel I/O module with a new push-button MTB panel I/O module.

6.

Replace and tighten the 9 mounting screws then reconnect all cables.

7.

Set the node address to match the settings on the old push-button MTB panel by cutting the wire jumpers on the new push-button MTB panel I/O module.

8.

If you are using a custom MTB panel, set the shorting post of JPR3 over pins 2 and 3.

15B-49

Page 806

Section 15B Replacement Procedures

Figure 15B.14 Push-Button MTB Panel I/O Module Jumper Positions

+12V DC GND

CN51

OP12 (in)

OP11 (out)

JPR1 JPR2

CN52

PANEL JPR3 CUSTOM

15B.33 Replacing Digital I/O

3 2 1

MTB Panel Type

Pins to cover with the shorting post

Custom

3 and 2

Allen-Bradley

1 and 2

A-B

To replace the digital I/O: 1.

Disconnect the cable running from the external power source to the digital I/O. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the ac distribution network unless the main ac disconnect switch is open (off) and locked.

15B-50

2.

Disconnect the cables running from the external I/O devices to the digital I/O.

3.

Disconnect the fiber optic cables.

Page 807

Section 15B Replacement Procedures

4.

Remove the mounting screws, which are located at each corner of the digital I/O. Fuse

5.

Replace the old digital I/O with a new digital I/O.

6.

Replace and tighten the 4 mounting screws then reconnect all cables.

7.

Set the node address to match that of the old digital I/O using the switch assembly located between the fiber optic connectors.

O N1 2 3 4 5 6

15B-51

Page 808

Section 15B Replacement Procedures

15B.34 Replacing the Power Fuse on Digital I/O and Analog I/O

Under normal conditions the DC POWER indicator will be illuminated. If a fuse is blown, the DC POWER indicator will not be illuminated. One of the following conditions may have caused a blown fuse: Excessive line voltage Internal power supply malfunction. To replace a blown fuse: 1.

Disconnect the cable running from the external power source to the digital I/O. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Remove the fuse compartment cover.

3.

Remove the fuse holder; push the handle to the left, then pull outward.

4.

Remove the fuse from its holder and replace it with a recommended replacement fuse. ATTENTION: Use only replacement fuses of the type and rating specified for the unit. Improper fuse selection may result in equipment damage.

15B-52

5.

Place the fuse holder back into its compartment. Push inward until it locks into place.

6.

Replace the fuse compartment cover.

7.

Restore power. The DC POWER indicator should now be illuminated.

Page 809

Section 15B Replacement Procedures

15B.35 Replacing the High Density I/O

To replace the high density I/O: 1.

Disconnect the cable running from the external power source to the high density I/O. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Disconnect the cables running from the external I/O devices to the high density I/O.

3.

Disconnect the fiber optic cables.

4.

Remove the 4 mounting screws shown in the figure below that secure the high density I/O back plate to the cabinet.

5.

Replace the old high density I/O with a new high density I/O. There are two versions of the high density I/O module. If you are replacing an existing module with a different version of the high density I/O module, you will have to drill new mounting holes to secure the new module. Refer to page 2B-21 for mounting dimensions for both of these modules.

6.

Replace and tighten the 4 mounting screws then reconnect all cables.

7.

Set the node address to match that of the old high density I/O using the switch assembly shown in the figure below. The location of this switch is slightly different between the two available modules.

8500-HDM1

8500-HDM 12

12

34

3

45

6

56

15B-53

Page 810

Section 15B Replacement Procedures

15B.36 Replacing the Analog I/O

To replace the analog I/O: 1.

Disconnect the cable running from the external power source to the analog I/O. ATTENTION: To guard against electrical shock hazards, never make connections or disconnections at the AC distribution network unless the main AC disconnect switch is open and locked.

2.

Disconnect the cables running from the external I/O devices to the analog I/O.

3.

Disconnect the fiber optic cables.

4.

Remove the mounting screws, which are located at each corner of the analog I/O. Fuse

5.

Replace the old analog I/O with a new analog I/O.

6.

Replace and tighten the 4 mounting screws then reconnect all cables.

7.

Set the node address to match that of the old analog I/O using the switch assembly shown below.

O 1 2 3 N 4

This cover unsnaps and folds down to expose switches

8.

15B-54

Set the unipolar/bipolar switches to match the settings on the replaced analog I/O module.