Page 821

Section

16

Error and System Messages

Overview

This section serves as a guide to error and system messages that can occur during programming and operation of the 9/Series control. We listed the messages in alphabetical order along with a brief description. Important: To display both active and inactive messages, press the {ERROR MESAGE} softkey found on softkey level 1. For details, see Chapter 2. Important: This appendix covers only error and system messages. PAL-generated operator messages generally appear on lines 21 and 22 of the CRT and should be described in documentation prepared by the machine tool builder. Message

Description

Symbols (+) 15V SUPPLY FAILURE

+ 15 Vdc is not available at the main processor board. Check the wires from the main power supply and connector CN07 on the main processor board.

(- ) 15V SUPPLY FAILURE

- 15 Vdc is not available at the main processor board. Check the wires from the main power supply and connector CN07 on the main processor board.

(+) OVERTRAVEL PROGRAM ERROR

If axis motion continues along the programmed path, the indicated axis will reach or exceed the positive software overtravel limit (runtime error).

(- ) OVERTRAVEL PROGRAM ERROR

If axis motion continues along the programmed path, the indicated axis will reach or exceed the negative software overtravel limit (runtime error).

(+) OVERTRVL PRGRAM ERROR:

The end-point of the commanded move will cause the indicated axis to reach or exceed the positive software overtravel limit (pre-execution error).

(- ) OVERTRVL PRGRAM ERROR:

The end-point of the commanded move will cause the indicated axis to reach or exceed the negative software overtravel limit (pre-execution error).

+/- SIGN ERROR

A + or - sign was found out of place when a numeric value was being decoded. Check the active program block for programming format errors. 1

1394 AXIS MODULE MISMATCH

At power turn on the system identified an axis module in the 1394 rack that is misconfigured in AMP. If an extra axis module is present in the 1394 rack it should either be fully configured or not configured at all in AMP even if that axis module is not used or detached.

1394 RING COMMUNICATIONS ERROR

At power up the internal communications ring which runs through the front of the 1394 system and drive modules was either not connected, a device on the ring experienced a hardware failure, or a device on the ring was discovered to be misconfigured once a command was sent to the device. Make sure all axis modules and the end terminator are properly connected to complete the communication ring.

1746 RACK CARDS MISMATCH

The I/O configuration for the 1746 I/O rack that was downloaded from ODS, or resides in the PAL PROMs, contradicts what is actually in the rack (devices must match slot-for-slot).

1771 RACK CARDS MISMATCH

The I/O configuration for the 1771 I/O rack that was downloaded from ODS, or resides in the PAL PROMs, contradicts what is actually in the rack (devices must match slot-for-slot).

16-1

Page 822

Section 16 Error and System Messages

Message

Description

2 2MB RAM IS BAD/MISSING

The control has discovered the RAM SIMMs for the two megabyte extended storage option are either damaged or missing. The RAM SIMMs must be installed or replaced. Contact your Allen Bradley sales representative for assistance. 9

9/SERIES LATHE - CANNOT USE MILL AMP

The control was powered up with a lathe software option chip installed, when the AMP file that was downloaded was configured for a mill.

9/SERIES MILL - CANNOT USE LATHE AMP

The control was powered up with a mill software option chip installed, when the AMP file that was downloaded was configured for a lathe.

7300 7300 NAMES TABLE IS CORRUPTED

7300 program name doesn’t match corresponding name in cross-reference table.

7300 PATTERN NAME TOO LONG

More than 5 digits have been used in the pattern name.

A A RETRACE BUFFER WAS DELETED

The control required one (or more) of the block retrace buffers to perform a necessary block look-ahead operation (refer to block look-ahead in the user’s manual). When this occurs, less block retrace operations can be performed than AMP is configured to allow. If this error occurs, to improve control efficiency, it is recommended that the number of allowable block retrace blocks set in AMP be lowered or add additional RAM to you system.

ABS POSITION NOT INITIALIZED

This message indicates that axes with absolute encoders have not been homed. These axes require an initial homing operation to establish the absolute position.

ABSOLUTE FEEDBACK FAILURE

The control has detected a loss of feedback from the absolute encoder. The most likely cause of this error would be a broken or disconnected wire. Axis homing may be required after the error condition is corrected.

ACC/DEC CONFIGURATION ERROR

An axis configuration error was detercted by the control when manual acc/dec was requested in a program block.

ACCUM. AND EXPECTED LIFE ARE 0

No tool life data was entered for the current tool selected by the tool life management feature. Tool life management will be disabled for this tool.

ACTIVE GROUP CANNOT BE DELETED

An attempt was made to delete a tool group in the tool life management feature that contains an active tool currently in the tool holder.

ACTIVE OFFSET CANNOT CHANGE

An attempt was made to alter a tool offset value of a tool offset that is currently the active tool offset on the control. The active tool offset is indicated with an * on the tool offset table.

ACTIVE TOOL CANNOT BE CHANGED

An attempt was made to edit tool data for the currently active tool. De-activate the tool before editing.

ACTIVE TOOL CANNOT BE DELETED

An attempt was made to delete tool data for the currently active tool. De-activate the tool before editing.

ADAPTIVE FEED MAX LIMIT

The actual torque is less than the desired programmed torque and the adaptive feed axis has reached the programmed maximum feed limit. Either raise the programmed maximum feed limit, or lower the programmed desired torque.

ADAPTIVE FEED MIN LIMIT

This message indicates your are exceeding the programmed desired torque. The actual torque is greater than the desired programmed torque and the adaptive feed axis has reached the programmed minimum feed limit. Either raise the programmed desired torque or lower the minimum feed limit.

ADAPTIVE FEED PROGRAMMING ERROR

E and Q must both be programmed in every G25 block.

ALL DUAL AXES ARE PARKED

An attempt was made, while using dual axes, to move the dual group when all the axes of that group were parked.

AMP FILE SIZE ERROR

The size of the AMP file being downloaded is incorrect. The file cannot be downloaded.

16-2

Page 823

Section 16 Error and System Messages

Message

Description

AMP IN BACKUP DOES NOT MATCH AMP IN RAM

This message always appears after a successful AMP download if the downloaded file is different from the one currently stored in backup memory. Its purpose is to remind the user to copy the downloaded AMP into backup memory after testing it.

AMP WAS MODIFIED BY PATCH AMP UTILITY

This message always appears after changes have been made to AMP using the patch AMP utility. Its purpose is to remind the user that the current AMP has not been verified by a cross-reference check normally performed by ODS. It is meant as a safety warning.

AMPED HOLDING OR DETECT TRQ OUT OF RANGE

This message is displayed when you have entered a value in AMP for either the holding torque or the detection torque, for the feed to hard stop feature, that is higher than the value entered for the servos available peak torque. You must change your AMP values.

ANALOG SERVO VOLTAGE FAILURE

A + 15V to the servo cards has failed.

ANGLE WORD NOT ALLOWED

An angle word was programmed in a QPP block where it is not allowed, for example, programming an angle word in a circular QPP block.

ANGLED WHEEL AXES, JOG ONE AT A TIME

While in the angled wheel grinding mode you can not jog more than one axis in the angled wheel plane at any one time.

ANGLED WHEEL CONFIG ERROR

The angled-wheel grinder AMP downloaded to the control is not configured correctly. Make sure all necessary angled-wheel parameters are configured correctly and re-download AMP to the control.

ANGLED WHEEL NOT CONFIGURED

You have attempted to program an angled wheel grinder mode function and the angled wheel feature has not been correctly configured for your system. The angled wheel feature must be configured in AMP and is a purchased option for your 9/Series control.

ARCTAN SYNTAX ERROR

An attempt was made to calculate or execute a paramacro block that calculates the arc tangent of an invalid or improperly entered number.

ARITHMETIC OVERFLOW ERROR

An internal math error has occurred; contact Allen-Bradley customer support service.

ARITHMETIC UNDERFLOW ERROR

An internal math error has occurred; contact Allen-Bradley customer support service.

AUX FB NOT ALLOWED WITH DEPTH PROBE

Your AMP file has a depth probe configured for an axis that also is configured to use an optional feedback device. A depth probe can not be configured to use any feedback device other then its depth probe for that depth probe axis. If a second feedback device is used it is configured in AMP as a separate logical axis.

AUXILIARY FEEDBACK DISCONNECTED

The digital servo module provides the capability to use two different feedback encoders with one servo (in the case where two encoders are used, the auxiliary encoder is used for the position feedback). If the servo processor detects that the auxiliary encoder has been disconnected, this message is displayed.

AUXILIARY FEEDBACK QUADRATURE FAULT

The digital servo module provides the capability to use two different feedback encoders with one servo (in the case where two encoders are used, the auxiliary encoder is used for the position feedback). If the servo processor detects a quadrature fault on the auxiliary encoder, this message is displayed.

AUXILIARY SPINDLE 2 NOT CONFIGURED

For aux spindle 2 to be programmable, it must be configured in AMP; a decode error.

AUXILIARY SPINDLE 3 NOT AVAILABLE

AMP configuration error; aux spindle 3 can be configured only on a 9/290.

AUXILIARY SPINDLE 3 NOT CONFIGURED

For aux spindle 3 to be programmable, it must be configured in AMP; a decode error.

AXES COLLISION

Two processes have collided. Interference checking has stopped all motion.

AXES CONFIGURED ON INACTIVE PROCESS

An AMP was loaded that contains an axis that was configured for an inactive process. Set the process axis in AMP to a process that has been configured.

AXES DATA MISSING

Expected axis data is missing in a program block.

AXIS AMPED AS NON-SCALING AXIS

The user attempted to scale an axis that was AMPed as non-scaleable.

AXIS ASSIGNED TO PAL AXIS MOVER

The user attempted to move the axis configured as the PAL axis mover axis by some means other than PAL.

AXIS DISPLAY DISABLED BY PAL

The position display for a selected axis has been turned off using the $NODP flag.

16-3

Page 824

Section 16 Error and System Messages

Message

Description

AXIS IN PLANE DOES NOT EXIST

At least one of the axes assigned to a plane that was defined in AMP does not exist. An example of when this error would occur is if an axis was renamed in AMP, but that new name was not entered into the AMP plane definition. Another example would be if an unfitted axis was assigned to that plane.

AXIS INVALID FOR G24/G25

The programmed axis was not AMPed for software velocity loop operation, and can not be used in a G24 or G25 block. To use these features the axis programmed must be configured for tachless operation (or be a digital servo).

AXIS IS HARD STOPPED, CANT ADJUST SERVO

The torque limit of the servo can not be adjusted because, either the axis is in a hard- stopped state, or some other axis on the same servo card is in a hard- stopped state.

AXIS MODULE POWER FAULT

The axis module hardware has faulted from a short duration over current condition. If the output current exceeds a fixed level (Over 200% of axis module rating for the 10 and 15 Kw modules and Over 300% for the 2, 3 and 5 Kw modules) this fault will appear. Typical causes are a shorted lead, motor malfunction, or malfunctioning power IGBTs.

AXIS MODULE OVER CURRENT

One of the axis modules of your 1394 drive has been requested to provide too much current over an extended time period. This is typically caused by: Accel/Decel command from the CNC is requiring peak current for an excessive amount of time, the machine friction or inertial/viscous load is excessive, the motor has been improperly sized, a short circuit exists across the drive output terminals, logic supply circuits have malfunctioned, or AC input is incorrectly wired.

AXIS MODULE BUSS VOLTAGE LOSS

The DC bus supply was lost to the axis module. Check slider connections/termination strip or there could be a blown link fuse. This condidtion also occurs in a systemE- stop state.

AXIS MODULE OVER TEMP

The 1394 contains a thermal sensor which senses the internal ambient temperature. Causes could be: that the cabinet ambient temperature is above rating. The machine duty cycle requires an RMS current exceeding the continuous rating of the controller. The airflow access to the 1394 is limited or blocked. This does not necessarily indicate a motor over temperature. Motor over temperture sensors should be wired directly into the E-Stop string.

AXIS MOVER CONFLICT WITH G16.3/G16.4

You have requested a PAL axis mover function on an angled wheel grinder. You can not use the PAL axis mover in one of the angled wheel modes unless the PAL axis mover has control of both the axial and the wheel axes.

AXIS NAME DUPLICATE

Two or more axes have been assigned the same name in AMP.

AXIS NOT IN PROCESS

You attempted to read/write a paramacro parameter for an axis that is not currently in the process requesting the data. To access paramacro parameter data for an axis, that axis must be in the process making the request.

AXIS POSITION INCORRECT

Using the mid-start program function, you have searched to a block that does not create the programmed contour if started from your current axis position. Be aware the mid-start operation may have searched thru a offset operation that is not readily apparent to determine your axis position. The mid-start operation is aborted. You must re-perform the mid-start operation and either position the axes to the correct axis position, or use the {MOVE & EXIT} softkey to find the correct axis position.

AXIS SELECT NOT ALLOWED

The {AXIS SELECT} softkey was pressed when no axis select option is available. Axis select is only available on large screens and normal character size screen for systems that contain more then 9 axes total or dual process systems with more than 8 axes in a process. It is not available when the small screen (showing all system AMPed axes) is being viewed.

AXIS TYPE-POSITION LOOP ERROR

In patch AMP, an axis was assigned a position loop type that is illegal for the axis type assigned to that axis.

B BACKUP VERSION OF AMP WAS COPIED TO RAM

The AMP in RAM was erased (battery backup failed) or corrupted, so the control automatically copied the version of AMP in backup memory into RAM memory. (The control stores AMP in backup, but works from the copy of AMP in RAM memory.)

BAD DAC MONITOR PATCH AMP ENTRY

An invalid value was entered into patch AMP parameter #86 or #87. Either parameter allows the axes to be monitored through the servo module (DAC) analog output. See documentation provided by Allen-Bradley on patch AMP, or contact Allen-Bradley customer support service.

16-4

Page 825

Section 16 Error and System Messages

Message

Description

BAD FIRST POCKET BLOCK

When performing an irregular pocket cycle, the first pocket block should be away from the pocket start/end corner, not toward it. The move to the start/end corner is generated based on the coordinates programmed in the pocket definition block itself.

BAD PAL PROM

One of the PAL PROM chips (plugged into the main processor board) has failed or is not plugged in properly.

BAD RAM DISC SECTOR CHECKSUM ERROR

A RAM disk sector error was detected during the RAM checksum test at power-up. Attempt to power-up again. If the error remains, contact Allen-Bradley customer support services.

BAD RECORD IN PROGRAM

This indicates a serious problem with the program. Attempt to open the program a second time. If retry doesn’t work, you may have to delete the program. Typically this error is not caused by a programmer or operator action. It is typically caused by an internal software error in the program.

BAD STATE/TOKEN COMBINATION (PROGRAM ERROR)

While attempting to decode the current block, a combination of characters caused a decode error to occur. Check the characters in the current block for an illegal combination.

BATTERY FAILURE

The battery that provides backup of the RAM memory is not functioning; the voltage may be low. The battery may be dead, removed, or poorly connected.

BLK DELETE CHG IGNORED ON PREPARED BLKS

A block-delete was activated while a program was executing. This change is ignored by the control for blocks that have already been read into the control’s set-up buffer (see block look-ahead in user’s manual).

BLOCK LENGTH ERROR

A block that exceeds the allowable maximum block length was programmed.

BLOCK RETRACE ABORTED

The block retrace operation being performed has been canceled. When <CYCLE START> is pressed, the control will return the tool along a linear path back to the start-point of the block retrace operation.

BOOT DIRECTORY IS MISSING

The update utility failed to properly create the system boot directory. Retry the update. If the error occurs again, contact your local Allen Bradley service.

BOOTSTRAP FAILED TO START

The bootstrap code did not send the “ok”signal to the main processor within the specified time.

BOTH AXES IN QPP PLANE NOT PRGMD

The second block of a currently executing QuickPath Plus two-block set does not contain both required axis words in the current plane. Both axis words are required to correctly identify the end-point of the second move.

BOTH LINES ARE PARALLEL

Both blocks of a two-block QPP sequence are parallel, and no mathematical intersection can be computed.

BOTH PORTS ARE BUSY

An attempt was made to use or monitor communication ports A or B when neither were available.

BUSY, REQUEST IGNORED

You have requested an operation while the control is currently executing some other higher priority function. The control must first complete the higher priority task before your new task can be performed.

C CALLED 7300 PATTERN NAME IS BAD

The 7300 pattern name that is called by a part program does not exist .

CANCEL/REMOVE OFFSET BEFORE AXIS CHANGE

You have attempted to change the active tool length axis while an length offset is currently active on that axis. You must cancel tool length offsets before you are allowed to change the active tool length axis.

CANNOT (GOTO) TO INSIDE A (DO)

A (GOTO) command cannot transfer execution to a block which is located within a (DO) loop.

CANNOT ACCESS REMOTE VARIABLE

Variable name is invalid. Check the fields for CNC name and remote name, and make sure they are in the correct format.

CANNOT ACTIVATE - OPEN PROGRAM

An attempt was made to activate a program for execution when it was still open for an editing operation. Before it can be activated for automatic execution, it is necessary to press the {EXIT EDITOR} softkey from the edit menu to close a program being edited.

CANNOT ACTIVATE RAM PARTITION

The RAM disk has been corrupted. Attempt to perform a “REFORMAT”operation. If this is unsuccessful, consult Allen-Bradley customer support services.

16-5

Page 826

Section 16 Error and System Messages

Message

Description

CANNOT ASSIGN IN CURRENT MODE

An attempt was made to modify a paramacro parameter that cannot be modified when the cutter compensation or TTRC feature is active.

CANNOT CALCULATE - PROMPT PRESENT

An attempt to perform a calculate operation was made when some other prompt was present on line 2 of the CRT. Before the control will allow a calculation to be made, it is necessary to remove any prompts from line 2 .

CANNOT COPY

The requested copying task cannot be performed due to an internal problem in the file or RAM disk. Contact Allen-Bradley customer support service.

CANNOT DELETE - OPEN PROGRAM

The selected program is either active or open for editing and cannot be deleted.

CANNOT DELETE ALL PROGRAMS

An attempt was made to delete all part programs or to reformat RAM while a program was being edited or was currently selected as the active program for execution.

CANNOT DELETE PROGRAM

The file selected cannot be deleted. This is caused by a major error being detected in the actual software file of the program. It may be necessary to “REFORMAT”RAM to remove the program. If this is unsuccessful, contact Allen-Bradley customer support service.

CANNOT DIVIDE BY ZERO

An attempt was made to divide a quantity by zero, either using the CALC functions or in an executing program with a paramacro operator.

CANNOT EDIT - FILE UPLOADING

The file you’ve tried to open is already open and is in the middle of a part program upload or download operation with ODS.

CANNOT EDIT - MUST BE IN CYCLE OR E-STOP

An attempt was made to edit a part program while another part program was currently being executed.

CANNOT EDIT - OPEN PROGRAM

The program that you have selected for editing is currently open for another feature.

CANNOT EDIT - OTHER FILE IS BEING EDITED

An attempt was made to edit a part program while another part program was currently being edited.

CANNOT EDIT ACTIVE PROGRAM

An attempt was made to edit a program that is currently selected as the active program for execution. Before it can be edited, the program must first be disabled.

CANNOT EXIT IN CYCLE

You cannot exit in the middle of a roughing cycle because it executes at runtime, not during setup.

CANNOT FIND CORRECT POSITION

The program-restart feature cannot locate the correct program block in the program at which automatic execution was interrupted. To position the program at the correct block, it will be necessary to perform one of the other search operations. The operator must know what this correct block is as the control has failed its recover operation.

CANNOT FIND PAL PAGE

PAL requested a PAL display page to be displayed that does not exist in the display page file.

CANNOT FORMAT - OPEN PROGRAM

A program was selected for automatic execution or was still in the edit mode when a request to format memory was made. The active program must be disabled by pressing the {CANCEL PRGRAM} softkey, and any program being edited must be closed by pressing the {EXIT EDITOR} softkey before formatting memory.

CANNOT FORMAT RAM PARTITION

The control is unable to format memory due to open file conditions indicating a more serious problem. Consult Allen-Bradley customer support services.

CANNOT JOG - ALL AXES ARE PARKED

An attempt was made to jog a dual group when all the axes were parked.

CANNOT MERGE WITH SAME PROGRAM

An attempt was made to merge the same program that is being edited with itself. If this is desirable, first copy the original program, then merge the copy into the original.

CANNOT OPEN DIRECTORY

This indicates a serious RAM disk problem. If retry doesn’t work, you may have to reformat.

CANNOT OPEN PROGRAM FOR READ

This indicates a serious problem with the program. If retry doesn’t work, you may have to delete the program.

CANNOT OPEN PROGRAM FOR WRITE

An error occurred while attempting to open a file on the RAM disk. Either the RAM disk is full, or there is an internal problem with the file. The file may need to be deleted.

CANNOT OPEN SUBPROGRAM

An attempt to call a sub-program has failed. This is usually caused by the sub-program name (programmed in the calling block with a P-word) not existing in the current program directory.

16-6

Page 827

Section 16 Error and System Messages

Message

Description

CANNOT READ A WRITE-ONLY PARAMETER

An attempt was made to use the value of a paramacro system parameter that is a write-only parameter. This parameter may have only its value written to. It cannot be read.

CANNOT READ DIRECTORY

This indicates a serious RAM disk problem. If retry doesn’t work, you may have to reformat.

CANNOT READ PROGRAM

This indicates a serious problem with the program. If retry doesn’t work, you may have to delete the program.

CANNOT RENAME

When performing a rename of a program name, the new program name has not been correctly entered. The format is OLD PROGRAM NAME,NEW PROGRAM NAME.

CANNOT REPLACE START POINT

An illegal attempt was made to change the axis calibration start-point using the online AMP feature.

CANNOT RESTART G24 HARD STOP

An attempt was made to restart a part program on a block which would have an axis at the hard stop. You cannot restart or mid start a part program after if (at that blocks execution) any axis would be holding against a hard stop. You must either re-start/mid- start to a block before the G24 hard stop block or to a block after the hard stop is released.

CANNOT SEND AVAILABLE COMMAND

This is displayed when a non-programmed communications command is executed from “send’¨softkey.

CANNOT SET DATA WHEN TOOL IS ACTIVE

An attempt was made to manually (using the softkeys) change tool management data for the currently active tool. Tool management data can be changed only for a tool that is not currently selected as the active tool.

CANNOT TAP IN CSS

You must disable the CSS feature before you begin a tapping operation. Disable CSS using a G97 command.

CANNOT TAP IN VIRTUAL-C MODE

You attempted to use the solid tapping feature while cylindrical or end-face milling was active.

CANNOT UPLOAD - PAL NOT IN PROM

PAL can be uploaded only from the PAL PROMs. PAL in RAM memory cannot be uploaded.

CANNOT UPLOAD - PAL SOURCE NOT LOADED

When the source is loaded, PAL can be uploaded in the 9/240 only . The 9/260 and 9/290 always have PAL in flash.

CANNOT USE COPY WITH ACTIVE TOOL OFFSET

An attempt was made to copy offset data from one axis to another using the {COPY OFFSET} softkey. You cannot use this softkey if the tool offsets are active.

CANNOT USE EXIT - BLOCK NOT FOUND

An attempt was made to {EXIT} while searching for a block for a mid-program start. You cannot use {EXIT} until the block has been found. To abort the search, use {QUIT}.

CANNOT WRITE A READ-ONLY PARAMETER

An attempt was made to assign a value to a PAL or system paramacro parameter that is a read-only parameter. The value of these parameters can be used only by the programmer; they cannot be altered in the program.

CANNOT WRITE TO PROGRAM

This indicates a serious problem with the program. Attempt to write to program a second time. If retry doesn’t work, you may have to delete the program. Typically this error is not caused by a programmer or operator action, but rather by an internal program software error.

CAUTION! YOU ARE IN 7300 TAPE MODE TO RETURN TO STANDARD 9/240 MODE RESET THE 7300- COMPATIBILITY PAL FLAG

The operator is cautioned that the tape being copied is presumed to be a 7300 formatted tape. This message is displayed on the copy-tape set-up screen when the MCU is in 7300 compatibility mode.

CC/TTRC ON, CAN’T ASSIGN TIME DEP. PARAM

An attempt was made to assign a time-dependent paramacro system parameter while dresser/wheel radius compensation was active. Time-dependant parameters are any system parameters that record or reference a current axis position.

CHAMFER LENGTH/RADIUS TOO LARGE

A chamfer or radius value programmed with a ,C or ,R would generate a chamfer or radius that is larger than one or both of the two adjacent tool paths.

CHAMFER/RADIUS NOT ALLOWED

An attempt was made to perform a chamfer or radius cut (programmed with a ,R or ,C) in a block that does not allow these functions to be performed. For example, you cannot do a chamfer or radius cut in a non-motion block, in the last block on an MDI line, or in the last block of a part program.

CHANGE NOT MADE IN BUFFERED BLOCKS

Changes to the offset table did not affect those program blocks that were already in the control’s current activation queue. Program blocks that call for offsets and which follow those already in the activation queue will call the updated offset tables.

16-7

Page 828

Section 16 Error and System Messages

Message

Description

CHANNEL NAME TOO LONG

There is an error in G05 DH+ communications block.

CHAR MUST BE _, ., LETTER, DIGIT

You have used incorrect search string syntax in the PAL search monitor utility.

CHAR MUST BE LETTER,DIGIT, UNDERSCORE

You have used incorrect search string syntax in the PAL search monitor utility.

CHARACTERS MUST BE DIGIT

You have used incorrect search string syntax in the PAL search monitor utility.

CHARACTERS MUST FOLLOW WILDCARD

You have used incorrect search string syntax in the PAL search monitor utility.

CHECKSUM ERROR IN FILE

The file (AMP, PAL) being downloaded from a storage device has a checksum error. The file cannot be used.

CIRCLE MID-POINT NOT ENTERED

The center-point of an arc is not entered in a circular programming block. Circular blocks require programming either an R or an I, J, K in the block.

CIRCULAR BLOCK NOT ALLOWED

When activating cutter compensation, you cannot program a circular block as the first block or as the last block prior to deactivating cutter compensation.

CIRCULAR NOT ALLOWED AFTER SKIP

A circular move cannot immediately follow a G31 or G37 series skip block. Only linear moves are permitted as the next move following a G31 or G37 type code.

CIRCULAR PROGRAMMING ERROR

A circular motion was programmed incorrectly. Typically this occurs from incorrectly programming an R or I, J or K value.

CODING ERROR

A system software error has occurred. Consult Allen-Bradley customer support services.

COM COMMAND TABLE IS CORRUPTED

Restore the flash version of the output command table.

COM CONFIGURATION TABLE IS CORRUPTED

Restore the flash version of the communication configuration table.

COMM ERROR WHILE PROCESSING HOST REQUEST

A communication error occurred between your PC and 9/Series while performing an update utility. Retry at a lower baud rate. If that does not work check communication ports, connections and cable wiring.

COMMUNICATION TIME-OUT

The time allowed for a peripheral device to respond has elapsed. Check cable connections and device set-up.

COMMUNICATIONS DISPLAY PAGE ENABLED

When a remote host enables the 9/Series remote operator display screen, this message is displayed.

COMMUNICATIONS LINK IS DOWN

A problem was detected in the communications line. Check the cables and retry the download/upload.

COMPLETED WITH ERROR(S)

A QuickCheck syntax check operation has completed the check of the currently active program and found one or more errors. Some editing of the program is required.

COMPLETED WITH NO ERRORS

A QuickCheck syntax check operation has completed the check of the currently active program and found no syntax errors.

CONFIGURATION EXCEEDS AVAIL MEMORY

This error occurs when the amount of available control memory drops below what is required to maintain a minimum 5 block setup buffer for program execution. The system is held in E-Stop when this error occurs. You may either chose to add more memory to your system or re-configure your system by decreasing the watch list allocation (in AMP) for OCI systems.

CONTINUE NOT ALLOWED

An attempt was made to continue a program search when no character string was entered. This can occur when an error is generated by the program being searched and the control cannot continue the search of the program correctly.

CONTROL RESET NOT ALLOWED

The Control Reset Request was not honored by the control (e.g., a Control Reset Request during Cycle Suspended state).

CORRUPTED PROGRAM FOUND & DELETED

Program was found to be corrupted and not usable. This program was deleted.

CPU #2 DUALPORT RAM FAILED

The DUALPORT RAM memory shared between the 68000 main processor and the Z80 I/O ring processor has failed. (two 98030’s instead of the 68000 and Z80 on 9/230, 9/260, and 9/290 controls)

CPU #2 EXEC IS BAD/MISSING

CPU #2 exec is not in flash; you must use update utility to load it (9/290 only). Consult Allen-Bradley customer support services.