Page 846

Section 16 Error and System Messages

Message

Description

MEMORY CRASH - REFORMAT

A major error has occurred within the system RAM memory. All part programs stored in memory will have to be be deleted by performing a reformat operation. This will not remove the current versions of AMP or PAL from the system.

MEMORY FULL

There is no more RAM memory space for part program storage. If you are in the process of editing a part program, your changes cannot be saved.

MIDSTART NOT ALLOWED FROM TAPE

You cannot perform a mid-program start on a program that is stored on tape. The program must first be transferred to RAM memory.

MINIMUM RPM LIMIT AUXILIARY SPINDLE 2

The commanded aux spindle 2 speed requested by the control is less than the AMPed minimum aux spindle 2 speed for the current gear being used. This requires a gear change operation or a change in the programmed aux spindle 2 speed. In some cases, the <SPINDLE SPEED OVERRIDE> switch may be sufficient.

MINIMUM RPM LIMIT AUXILIARY SPINDLE 3

The commanded aux spindle 3 speed requested by the control is less than the AMPed minimum aux spindle 3 speed for the current gear being used. This requires a gear change operation or a change in the programmed aux spindle 3 speed. In some cases, the <SPINDLE SPEED OVERRIDE> switch may be sufficient.

MINIMUM RPM LIMIT FIRST SPINDLE

The commanded spindle 1 speed requested by the control is less than the AMPed minimum spindle 1 speed for the current gear being used. This requires a gear change operation or a change in the programmed spindle 1 speed. In some cases, the <SPINDLE SPEED OVERRIDE> switch may be sufficient.

MINIMUM RPM LIMIT PRIMARY SPINDLE

The commanded primary spindle speed requested by the control is less than the AMPed minimum primary spindle speed for the current gear being used. This requires a gear change operation or a change in the programmed primary spindle speed. In some cases, the <SPINDLE SPEED OVERRIDE> switch may be sufficient.

MINIMUM RPM LIMIT SECOND SPINDLE

The commanded spindle 2 speed requested by the control is less than the AMPed minimum spindle 2 speed for the current gear being used. This requires a gear change operation or a change in the programmed spindle 2 speed. In some cases, the <SPINDLE SPEED OVERRIDE> switch may be sufficient.

MINIMUM RPM LIMIT THIRD SPINDLE

The commanded spindle 3 speed requested by the control is less than the AMPed minimum spindle 3 speed for the current gear being used. This requires a gear change operation or a change in the programmed spindle 3 speed. In some cases, the <SPINDLE SPEED OVERRIDE> switch may be sufficient.

MIRROR NOT ALLOWED ON ROLLOVER AXIS

You cannot perform mirrored motion using an axis with rollover.

MISSING 1394 I/O RING ADDR

This message indicates that a 1394 amplifier ID has been AMPed but not defined in I/O ring assignment from ODS. The 1394 amplifier must be a defined device on the 9/Series fiber optic I/O ring.

MISSING ( [ ) AFTER FUNCTION NAME

Paramacro and calculator functions must have their values enclosed in [ ], for example, SIN[5].

MISSING ( ] )

Paramacro and calculator functions must have their values enclosed in [ ], for example, SIN[5]. The control has found that a right bracket “]”is missing in the current operation.

MISSING (END) COMMAND

The control has found an end-of-program block (M02 or M30) before it has read the END command for a paramacro DO loop.

MISSING (F) IN INVERSE TIME

An F-word must be programmed in every motion block that is not rapid when in inverse time feed mode (G93). F is not modal in G93.

MISSING (GOTO) COMMAND

An IF paramacro condition does not have a GOTO with a sequence number following the condition.

MISSING A (DO) COMMAND

A WHILE paramacro condition does not have a DO with a loop identifier following the condition.

MISSING ADAPTIVE FEED DATA

An attempt was made to create a transfer line part program from the quick view screen with incomplete adaptive feedrate data.

MISSING COMMA

An error occurred in G05 DH+ communications block.

MISSING COMMA OR RIGHT PARENTHESIS

An error occurred in G05 DH+ communications block.

16-26

Page 847

Section 16 Error and System Messages

Message

Description

MISSING CUTTER COMP CODE

Cutter compensation must be activated before initiating a G89 irregular pocket cycle.

MISSING DATA FROM BLOCK

G89 irregular pocket cycle parameters are missing from a the G89 programming block.

MISSING END PARENTHESIS

An error occurred in G05 DH+ communications block.

MISSING G67

An active modal macro (G66 or G66.1) was not canceled by a G67 before the control read an M02 or M30 end-of-program command.

MISSING HPG FROM I/O RING

The I/O assignment file that was compiled and downloaded with PAL defines an HPG that is not physically present in the I/O ring. Verify that the HPG address settings are correct.

MISSING I/O RING DEVICE

The I/O assignment file that was compiled and downloaded with PAL defines an I/O ring device that is not physically present in the I/O ring. Verify that all device address settings are correct.

MISSING INTEGRAND/RADIUS WORD

A circular or helical block has been programmed with axis data and no radius (R) or integrand (I, J, or K) values. A radius or integrand must be programmed in a circular or helical block to define the location of the arc center.

MISSING KEYBOARD AND HPG FROM I/O RING

The I/O assignment file that was compiled and downloaded with PAL defines a keyboard and an HPG that is not physically present in the I/O ring. Also verify that the keyboard and HPG address settings are correct.

MISSING KEYBOARD FROM I/O RING

The I/O assignment file that was compiled and downloaded with PAL defines a keyboard that is not physically present in the I/O ring. Verify that the keyboard address settings are correct.

MISSING L-WORD

The L-word parameter is missing from the G88.5 or G88.6 hemispherical pocket programming block.

MISSING M02 OR M30

The control has executed through to the last block of a program and has not read an end-of-program command (M02 or M30).

MISSING MASTER AXIS NAME

Slave axes that do not have a master have been configured for a dual group.

MISSING OR ILLEGAL L-VALUE

An attempt was made to program an irregular pocket milling cycle (G89) with a missing or illegal L-word.

MISSING PROGRAM NAME

An operation, such as a copy or rename, was performed without the proper program names being specified. The proper format consists of the program performing the operation followed by a comma and the target program (OLD PROGRAM NAME,NEW PROGRAM NAME).

MISSING PROGRAM NUMBER (P)

No sub-program name was specified in a block that calls a sub-program or paramacro. A sub-rogram name must be programmed with a P-word in the calling block.

MISSING PROMPT DATA

The control is waiting for data to be entered on the input line (line 2 of the CRT) using the keys on the operator panel.

MISSING Q-WORD

The Q-word parameter is missing from the G88 or G89 programming block.

MISSING QPP ANGLE WORD

The second block of a two block QPP set does not contain the necessary angle word to define an intersection with the first block.

MISSING ROUGHING CYCLE (P/Q) WORD

A roughing cycle block was programmed that does not contain both a starting and ending sequence number for the contour blocks as programmed with the P- and Q-words.

MISSING ROUGHING CYCLE DEPTH (D) WORD

A roughing cycle block was programmed that does not contain the D parameter for depth of cut.

MISSING SHADOW RAM

Either your 9/290 control is missing the SIMMS necessary for shadow RAM, or your 9/260 control is not equipped with enough RAM to operate properly. If your 9/260 system contains both the DH+ module and the search monitor utility, additional RAM must be installed. All 9/290 controls must have this additional RAM. Refer to your 9/Series installation and maintenance manual for details on installing SIMMS.

MISSING SLAVE INCREMENTAL AXIS NAME

When using dual axes on Lathe A, all slave axes must have incremental axis names.

MISSING START PARENTHESIS

An error occurred in G05 DH+ communications blocks.

MISSING TOOL ENTRY

This is missing a tool entry.

MODULE(S) WITH INCONSISTENT REVISION LEVEL

Retry the update utility. If this does not work, call Allen-Bradley and request a new update utility that matches your hardware revision level.

16-27

Page 848

Section 16 Error and System Messages

Message

Description

MODULE(S) WITH INVALID CHECKSUM

Retry update.

MOTION IN DWELL BLOCK

An attempt was made to program axis motion in the same block that generates a dwell. No axis words can be programmed in a block that generates a dwell.

MOTION NOT ALLOWED

The block includes G-codes that must be programmed in a block without axis motion. For example, the G-codes that convert from inch to metric or metric to inch cannot have axis motion in the same block.

MOTOR SHAFT - LEAD SCREW RATIO TOO HIGH

The motor shaft to lead screw gear ratio is too high to achieve the rapid speed assigned in AMP.

MULTIPLE FUNCTIONS NOT ALLOWED

Multiple functions are not allowed.

MULTIPLE SPINDLE CONFIGURATION ERROR

Each multiple spindle must have a servo board identified in AMP to indicate to which board the spindle is connected. The spindle must be included in the number-of-motors AMP parameter for the board the spindle is on.

MUST ASSIGN TOOL NUMBER FIRST

In random tool, an attempt was made to customize a tool before the tool number was assigned.

MUST BE IN (AUTO)

It is necessary to place the control in auto mode to perform the requested operation.

MUST BE IN (AUTO) OR (MDI)

It is necessary to place the control in Auto or MDI mode to perform the requested operation.

MUST BE IN (CYCLE STOP)

It is necessary to place the control in cycle stop state to perform the requested operation. The control cannot be in cycle suspend, feed hold, or E-Stop.

MUST BE IN (CYCLE STOP) AND (EOB)

The control must be in cycle stop state and at the end-of- program block to perform the requested operation. The control cannot be executing a program, in cycle suspend, feed hold, or E-Stop.

MUST BE IN (E-STOP)

An attempt was made to perform an operation (such as, editing the reversal error parameters in online AMP) that must be performed in E-Stop. Place the control in E-Stop by pressing the <E-STOP> button.

MUST BE IN (LINEAR MODE)

An attempt was made to perform an operation (such as, exiting from cutter compensation) that must be performed in a linear block (G00 or G01).

MUST BE IN (MANUAL)

It is necessary to place the control in manual mode to perform the requested operation.

MUST BE IN (MDI)

It is necessary to place the control in MDI mode to perform the requested operation.

MUST BE IN E-STOP OR CYCLE STOPPED

It is necessary to place the control in E-Stop or cycle stop state to perform the requested operation. Place the control in E-Stop by pressing the <E-STOP> button. Place the control in cycle stop state by pressing the <SINGLE BLOCK> button. Simply pressing <CYCLE STOP> will not guarantee the control to be in cycle stop mode. Most likely a cycle stop request while executing a program will place the control in cycle suspend mode. If you get this error using the CALC function it indicates you may be asking the calculator function to access a paramacro variable (using the # sign) when a program is executing. You can not use a paramacro variable # sign in a calculator function when any part program is executing or suspended.

MUST BE IN MANUAL MODE TO HOME

To do a jog home operation (from jog retract) the control must be in manual mode.

MUST COMPLETE ACTIVE HOME OPERATION

An attempt was made to jog a dual group when one of the axes of the dual was homing.

MUST DISABLE RUN-TIME GRAPHICS

An attempt was made to call up one of the QuickView prompting options while the active graphics option was currently executing. Active graphics must be disabled before QuickView prompting can be performed.

MUST HOME ANGLE SOURCE AXIS FIRST

Before you can enter angled wheel grinding mode both the axial and wheel axes must be homed.

MUST HOME AXIS

An attempt was made to perform axis calibration before the axes were homed. Axes can be homed manually or by programming a G28 block.

MUST SETUP THE ENCRYPTION ARRAY

An attempt was made to encrypt a part program while uploading it to ODS or the mini-DNC package. The encryption array must be set up before you can encrypt a part program.

MUST START WITH $, %, !, #, +, - , LTR, DIGIT

You have used incorrect search string syntax in the PAL search monitor utility.

MUST START WITH $, %, !, #, OR LETTER

You have used incorrect search string syntax in the PAL search monitor utility.

16-28

Page 849

Section 16 Error and System Messages

Message

Description

MUST START WITH $, %, !, OR LETTER

You have used incorrect search string syntax in the PAL search monitor utility.

MUST START WITH $, !, OR LETTER

You have used incorrect search string syntax in the PAL search monitor utility.

MUST START WITH A LETTER

You have used incorrect search string syntax in the PAL search monitor utility.

MUST SWITCH PROCESS FOR SCREEN RESTORE

An attempt was made to ‘restore screen’while the system was in Digitize, Graphics, Search, or while PAL was selecting a process. Any attempt to switch processes results in this message.

N NEED SHADOW RAM FOR ONLINE SEARCH

Your system contains the DH+ module and you have not installed the extra RAM SIMMS that are required to run the PAL online search monitor with the DH+ module installed. You must buy additional RAM for a system equipped with both of these features. Contact your Allen-Bradley Sales representative to purchase these SIMMS. Refer to your 9/Series integration manual for details on installing additional SIMMS.

NEED SPINDLE FEEDBACK

You attempted to use the solid- tapping feature or synchronization feature with a spindle that does not have feedback.

NEGATIVE DWELL VALUE

An attempt was made to execute a dwell with a negative value. Dwell values must be positive values.

NEGATIVE F-WORD PROGRAMMED

A negative feedrate was programmed in a program block. Negative feedrates are illegal.

NEGATIVE TO UNSIGNED LONG ERROR

Internal math error has occurred; contact Allen-Bradley customer support services.

NEGATIVE VALUE NOT ALLOWED

The minus (-) sign was used for an address which cannot be programmed with a negative value.

NET CORRECTION IS NOT ZERO

For a rotary axis, the net amount of correction for axis calibration should be zero for one complete revolution.

NET PICK/PLUNGE AWAY FROM ENDPOINT

The primary and secondary pick/plunge amounts, when added together, are in the direction away from the programmed endpoint.

NETWORK COMMUNICATION DISABLED

When editing or restoring communications configuration data, this message is displayed.

NETWORK PASSTHRU COMMUNICATIONS FAULT

A communication error has occurred between the controls ethernet module and the ODS passthrough device (typically a PLC).

NEVER OPENED THE PROGRAM

An attempt was made to edit a program that was not currently open.

NEW TOOL OFFSET SETUP BUT NOT ACTIVATED

The tool offsets for the active tool were changed, but not activated in the current block. These new tool offsets will not be activated until the set-up blocks are cleared of the old tool offsets and refilled with the new tool offsets.

NO ACTIVE PROCESS CONFIGURED

The AMP has been loaded into a multi-processing system that has no processes configured as active.

NO ACTIVE PROGRAM

An attempt was made to do a search when no part program is active.

NO AXIS CONFIGURED

The current active version of AMP does not have any axes configured as usable. All axes are configured as unfitted.

NO CHARACTERS ENTERED FOR SYMBOL

You have used incorrect search string syntax in the PAL search monitor utility.

NO DEPTH PROBE TRIP

A G26 block reached its programmed endpoint without the adaptive depth probe being tripped. The part surface was not detected by the adaptive depth probe before the G26 block completed.

NO FEEDRATE PROGRAMMED

A command for axis motion was executed when there was no active feedrate. Applies to non-rapid moves (G01, G02, or G03).

NO FURTHER RETRACE ALLOWED

The control has reached a block during retrace from which no further retrace is permitted.

NO INTERSECTION EXISTS

There is no mathematical intersection for the QPP blocks as programmed.

NO MARKER FOUND ON :

The encoder marker was not detected when homing the indicated axis. Homing was unsuccessful.

NO MORE MDI BLOCKS

Cycle start was requested during MDI mode when there were no MDI blocks present to be executed.

16-29

Page 850

Section 16 Error and System Messages

Message

Description

NO MORE MDI BLOCKS TO RESET

A reset was requested during MDI mode when there were no incomplete or unexecuted MDI blocks reset.

NO OFFSET ACTIVE

An offset must be active before the control will allow the offset to be changed. This check is used so that the control will no the method and direction of the offset will be the same as the previous offset.

NO OPTIONAL FB PORT ON ANALOG SERVO

The system was incorrectly AMPed with optional feedback module on an analog servo module.

NO PROGRAM TO RESTART

There is no program to restart. The previous program was either completed or cancelled.

NO RECIPROCATION DISTANCE

A reciprocation interval of zero (0) was programmed for a grinder reciprocation fixed cycle.

NO RECIPROCATION FEEDRATE

The reciprocation feedrate, E-word, required during a grinder reciprocation fixed cycle was not programmed.

NO SPINDLE ASSIGNED TO THIS PROCESS

A process attempted to activate virtual or cylindrical mode and that process has no spindle assigned to it via AMP.

NO STRING INPUT

A program search operation was requested and no string to search for has been entered. Key in the required search string, and press the [TRANSMIT] key to enter a search string.

NO TOOL GROUP PROGRAMMED

A block that loads data into the tool management table does not contain the parameter that determines the tool group number corresponding to the other data in the block. The group number is programmed using the P-word.

NO TOOL NUMBER PROGRAMMED

A block that loads data into the tool management table does not contain the parameter that determines the tool number corresponding to the other data in the block. The tool number is programmed using the T-word.

NO UNEXPIRED TOOL AVAILABLE

A request for a tool group was made, and all of the tools in that tool management group have expired their tool lives. Either reset the tool life for the tools, or install new tooling.

NON_CONSECUTIVE/TOO MANY FITTED AXES

More than the allowable number of axes may have been assigned in AMP or an unfitted axis was assigned between two fitted axes. You can assign only fitted axes consecutively in AMP.

NON-LINEAR AXIS IN PLANE DEFINITION

The current axis plane is illegal because a non-linear axis (rotary) has been assigned to the plane in AMP.

NOT ALIGNED

During the power- up alignment procedure, either the 1326 motor (connected to a 9/440HR) is misaligned or the SINCOS device’s memory is corrupt.

NOT ALLOWED IN ANGLED WHEEL MODE

The axes can not be moving when you change to angled wheel mode. Also the axes involved in angled wheel motion must be homed before you can enter angled wheel mode. Other features, such as block retrace or jog retract also must not be active when changing mode.

NOT ALLOWED - G41/G42 ACTIVE

An attempt was made to perform some operation or program some feature that cannot be performed when cutter compensation or TTRC is active (G41 or G42). Cancel compensation by programming a G40 block before performing the operation.

NOT ALLOWED FROM MDI

Certain programming commands are not allowed from MDI (GOTO, WHILE, etc.).

NOT ALLOWED ON DUAL/SLAVE AXIS

A G26 was programmed on a dueled axis. The G26 feature is incompatible with the dual axis feature.

NOT ALLOWED - THREADING ACTIVE

An attempt was made to perform some operation (typically a spindle speed adjustment) that is not allowed when cutting a thread. This includes all forms of threading, including single pass or multiple pass threads.

NOT IN G10L3 MODE

A G11 block was programmed that cancels G10L3 data setting when the control is not in the G10L3 data setting mode. G10L3 is used to set the tool management table data.

NUMBER IS OUT OF RANGE

An attempt was made to perform a calculation using the paramacro features or the calculator features that contains a number longer than 11 characters.

16-30

Page 851

Section 16 Error and System Messages

Message

Description

NUMBER OF MOTORS/SPINDLE CONFIG ERROR

This is error indicates AMP is incorrectly configured for the 9/Series hardware. Typical AMP configuration errors that generate this error include: You have AMPed more motors than the current hardware supports. You have indicated there are servo motors attached to servo boards that don’t exist (the 9/230 and 9/440 are configured as if they have only one servo card). You have configured too many spindles (1 on 9/230, 2 on 9/260 and 9/440, 3 on 9/290). Too few axes were configured for the indicated number of motors on the boards or too few servos were configured for indicated number of motors on the boards.

NUMERIC VALUE MISSING

The numeric value associated with the programmed word is missing. There is an AMP parameter that determines whether a missing numeric is assumed to be zero or if it will generate this error. O

OBJECT NOT FOUND IN PROGRAM

The object you are searching for in the search monitor utility does not exist in the current module, or does not exist in the program in the direction you are searching.

OCI ETHERNET CARD NOT INSTALLED

An OCI dual- process system has a standard CRT installed. The OCI Ethernet card has not been installed. This may happen if a dual- process OCI executive is loaded into a non- OCI system.

OCI SYSTEM ERROR

VRTX error. Contact Allen Bradley Support.

OCI PROCESSING TASK OVERLAP

The amount of time to process a new OCI request is taking longer than expected. This is an informational warning only. It i s not critical to the CNC.

OCI WATCH LIST TASK OVERLAP

This message indicates that the watch list task was not running to completion in the AMPed allotted amount of time. This typically occurs when a large task is requested by an OCI station and the CNC takes longer than expected to complete.

ODS & 9/SERIES REVISIONS DIFFER

The version of AMP or PAL on the peripheral device does not match the control version.

ODS RUNG MONITOR ACTIVE

The online PAL search monitor utility can not be accessed. The online PAL search monitor utility requires the offline ODS PAL search monitor utility to not be running.

OFFSET EXCEEDS MAX CHANGE

You have attempted to modify an offset table by an amount that is larger than the allowable change to an offset table. Refer to your AMP reference manual for details on Maximum wear and geometry offset change.

OFFSET EXCEEDS MAX VALUE

You have attempted to modify an offset table by entering an offset amount that is larger than the allowable maximum offset selected in AMP. Refer to your AMP reference manual for details on Maximum offset table values.

OFFSET MOTION PENDING ON CYCLE START

After changing the active offset this message identifies that the control will move the axis to the new offset location the next time cycle start is pressed (this may or may not occur on a non- motion block depending on the AMP offset configuration).

OFFSET TABLE(S) CORRUPT/CLEARED

A bad offset table checksum value was detected by the control during PTO.

ONLY ONE DEPTH PROBE PER SERVO BOARD

The 9/Series servo card firmware only supports one adaptive depth probe on each servo card. If your system requires more than one adaptive depth probe they must be attached to different servo cards (9/230 and 9/440 controls can only have one adaptive depth probe). AMP must be configured to indicate which port the adaptive depth probe is attached to.

ONLY ONE M19 ALLOWED PER BLOCK

For system configured with multiple spindles, only one spindle orient M-code (M19) is allowed per block.

ONLY REQUEST THE DUAL MASTER FOR JOGS

An attempt was made to jog a slave axis; you can jog a slave axis only when the master axis is parked.

OPTION NOT INSTALLED

An attempt was made to program an optional feature that has not been purchased from Allen-Bradley.

OPTION NOT INSTALLED (PAL DISPLAY PAGE)

The PAL display page option is not installed on your control.

OPTIONAL FEATURE IS NOT PROVIDED

An attempt was made to program an optional feature that has not been purchased from Allen-Bradley.

16-31

Page 852

Section 16 Error and System Messages

Message

Description

OPTIONAL RAM SIMM BAD/MISSING

The control has discovered the RAM SIMMs for the extended storage option are either damaged or missing. The RAM SIMMs must be installed or replaced. Contact your Allen Bradley sales representative for assistance.

OTHER PROCESS G CODE CONFLICT

On a dual processing system, one process has a conflicting G code active when you attempted to activate a G26 depth probe cycle. For example, process one executes a G26 while process two has an axis in feed to hard stop which is on the same servo card as the depth probe.

OVER SPEED

A servo motor is turning at an RPM that is greater than the maximum RPM allowed for that servo as defined in AMP by the system installer. For digital spindles this error can result from maximum RPM gear range 1 being set higher than your AMPed allowed Maximum Motor Speed.

OVER SPEED IN POCKET CYCLE

The programmed feedrate for an irregular pocket cycle (G89) was too high for the cycle to keep up. The part program stops at the endpoint of the block in which the error occurred. The cycle must be executed with a lower feedrate.

OVERTRAVEL (+)

The indicated axis has reached the positive software overtravel limit during an axis jog. This message can appear prior to reaching the overtravel limit in certain instances. For example, if a single pulse from the handwheel will result in a large incremental move beyond the overtravel limit, this error message will appear before the axis moves up to the limit.

OVERTRAVEL (-)

The indicated axis has reached the negative software overtravel limit during an axis jog. See OVERTRAVEL (+) for details. P

P VALUE OUT OF RANGE

An attempt was made to call a macro or sub-program using a program number, following the P-word, that is out of the valid range. Valid range for a P-word is 1 to 99999.

PAL & 9/SERIES REVISIONS DIFFER

Either the overall revision number of PAL does not match the software revision on the control, or the revision number of system symbols in PAL and the revision number of those on the control do not match.

PAL ANALOG PORT ILLEGAL CONFIGURATION

This is a power turn-on error that occurs when an AMP configuration error exists in the PAL analog port configuration.

PAL ANALOG PORT/SERVO F-W INCOMPATIBLE

PAL-controlled analog output port feature requires the servo firmware (f-w) revisions: Analog servo f-w rev 0.06 or greater Digital servo f-w re. 2.03 or greater Consult Allen-Bradley customer support services about servo firmware updates.

PAL AXIS STATUS CANNOT CHANGE

You attempted to change the status of a PAL axis (either to PAL axis or to a system axis) when it is not allowed. Examples of when the transition is not allowed are when the axis is jogging, performing jog retract, performing block retrace, etc...

PAL BACKGROUND TOOK TOO LONG

Background PAL was not completed in the time allocated to it in AMP. Background PAL will continue on to completion before restarting. If and when background PAL does complete in the allocated time, this message will disappear. If this message appears continuously, the PAL program should be rewritten, or else the AMP defined background PAL execution time should be increased. Refer to the AMP and PAL reference manuals for more details.

PAL DIVIDE BY ZERO ERROR

The PAL program tried to divide a value by zero. Check the PAL program for errors.

PAL DOES NOT EXIST

There is no PAL program in the system, either on EPROM or in RAM memory. EPROMs must be installed, or else PAL must be downloaded to RAM from ODS.

PAL INITIATED MOTION POSSIBLE

While in QuickCheck mode it is possible for PAL to physically move axes. This includes any motion generated by PAL including the PAL axis mover, or jogs that can occur in automatic mode such as jog on the fly or manual gap elimination. This message is cleared after the first block is executed in QuickCheck mode.

PAL OVERWRITING G54 ® G59.3

PAL is overwriting the current G54 - G59.3 offset through PAL offsets.

PAL PAGE WAITING - EXIT DISPLAY SELECT

A PAL display page is being overwritten by the current screen. Pressing the {DISPLY SELECT} softkey will display the display page.

16-32

Page 853

Section 16 Error and System Messages

Message

Description

PAL PAGE WAITING - EXIT MONITOR

A PAL display page is being overwritten by the current screen. Exit the search monitor utility to see the screen PAL is attempting to display.

PAL PAGE WAITING - SCREEN HAS PROMPT

A PAL display page is being overwritten by the current screen.

PAL PROM CHECKSUM ERROR

Checksum error in the PAL PROM memory. This indicates PAL has been loaded successfully however it has failed to pass verification. Check if your flash sticks are installed properly and are not damaged. Attempt to download a copy of the same PAL image from another project.

PAL SOURCE NOT DOWNLOADED TO CNC

The PAL search monitor utility can not be accessed. The PAL search monitor utility requires the PAL source code be downloaded with the built PAL program.

PAL SOURCE NOT LOADED

The copy of PAL in flash does not contain source programs.

PAL SOURCE REV. MISMATCH - CAN’T MONITOR

PAL source code in the control does not match the revision of the CNC executive. The PAL code may execute if all of the PAL system flags exist but the monitor cannot be used.

PAL USING MEMORY - REFORMAT

The AMP parameter allowing PAL to be stored in RAM memory has been enabled. This changes the amount of RAM memory available for part program storage, requiring the RAM disk to be reformatted. Part programs should have been backed up prior to this.

PARAMETER ASSIGNMENT SYNTAX ERROR

A block that assigns Paramacro parameters has been entered incorrectly.

PARAMETER NUMBER NOT FOUND

The AMP parameter number being searched for through the control’s patch AMP utility does not exist in the system.

PARAMETER VALUE OUT OF RANGE

The value entered for the selected AMP parameter or paramacro parameter is less than or greater than the allowed legal value.

PARENTHESIS INPUT ERROR

Parentheses have been entered incorrectly in a program block or calculation operation. Correct the use of the parenthesis; verify they are in matched pairs.

PARITY ERROR IN PROGRAM

A serial communications error has occurred. A data parity error occurred while sending or receiving data. This can result in a corrupted file, or the entire date transfer operation may be aborted by the control.

PARK AXIS MOTION NOT ALLOWED

Axis motion was programmed for a parked axis in a dual axis group. When both master and slave axes are parked, no axis motion is allowed on a parked axis in a dual group.

PART PROGRAM NOT SELECTED

An attempt was made to execute a program or check a program before a program was selected for execution.

PART ROTATION FORMAT ERROR

In part rotation blocks (G68, G69), only plane changes and mode changes including inch/metric and absolute/incremental are permitted. Any commands other than normal motion commands and the motion G-codes (G00, G01, G02, and G03) are not permitted.

PASSWORD PROTECTED

When assigning password protectable features to an access level, an attempt was made to assign a feature to a different access level when the currently active password does not have access to the feature. You can assign features to other access levels only when you have access to that feature yourself.

PEAK CURRENT NOT 300%

The axis for a 1394 or 9/440 is not AMPed to have the PEAK CURRENT set to 300%. This misconfiguration forces the control into E- Stop.

PERIPHERAL DEVICE ERROR

An illegal communication attempt was made with a peripheral device, for example, attempting to output to a tape reader or input from a tape punch.

PLANE SELECT ERROR

An attempt was made to change planes during cutter compensation (TTRC), between QPP blocks, or between chamfer and corner rounding blocks. This error also will occur if G17 or G19 planes are selected on a lathe.

PLEASE WAIT FOR CLEARING OF PAL MEMORY

PAL is being erased in preparation for a PAL download.

PLUNGE MOTION NOT ALLOWED

The final plunge position must be different from the start point of the cycle. This message can occur if the plunge axis is not programmed in the entry block to G89 mode, or if the plunge axis increment is zero, or if the final plunge axis position is the same as the start point of the cycle block during G89 mode.

16-33