Page 838

Section 16 Error and System Messages

Message

Description

ILLEGAL COMMAND FROM TEACH PENDANT

A non-recognized CMD-type packet was received in a DF1 packet from the teach pendant interface. Allowable CMDs are 60 - 63.

ILLEGAL CONTROL TYPE

You have downloaded from a peripheral device an AMP that does not match your control hardware.

ILLEGAL CPU #2 COMMAND

The 68000 main processor sent incorrect data to the Z80 I/O ring processor. (two 98030’s instead of the 68000 and Z80 on 9/230, 9/260, and 9/290 controls)

ILLEGAL CYLINDRICAL BLOCK

A G-code not allowed in a cylindrical entry block or during cylindrical programming mode was programmed.

ILLEGAL DCM FDBK ON RESOLVER SYSTEM

This message indicates that an illegal attempt has been made to configure a resolver based system with a Distance Coded Marker (DCM) A quad B device type on one or more of the feedback channels. When this error condition is encountered, the system will not be released from e- stop.

ILLEGAL DUAL CONFIGURATION

Both dual master axes names have the same letter OR when assigning dual groups in AMP, dual groups must be assigned in contiguous order, starting with group 1, 2, 3, 4, and 5. You can not assign axes to dual group 3 without axes having been assigned to dual groups 1 and 2.

ILLEGAL DUAL LINEAR/ROTARY CONFIGURATION

The dual group cannot contain a mixture of linear and rotary axes.

ILLEGAL FILENAME

An attempt was made to create a program using a program name that contains illegal characters. A different program name must be used.

ILLEGAL G40 EXIT BLOCK

An illegal sequence of exit moves was programmed in a G40 exit block.

ILLEGAL G88.5 OR G88.6 PARAMETERS

Illegal parameters were entered in a G88.5 or a G88.6 programming block.

ILLEGAL G99

An illegal G99 was entered in a programming block.

ILLEGAL G-CODE IN INTERRUPT MACRO

An illegal G-code has been programmed in a program called by a program interrupt. G24, G25, G26, G40, G41, G42, G52, G92, and G92.1 cannot be programmed in an interrupt program.

ILLEGAL G-CODE IN POCKET

An illegal G-code was entered in a G88 or G89 pocket-programming block.

ILLEGAL I/O RING DEVICE CODE

There is a device on the I/O ring that cannot be identified.

ILLEGAL I/O RING RACK SLOT CODE

There is a card in the 1771 I/O rack that the I/O ring cannot use.

ILLEGAL INPUT

A number was input from the keyboard instead of a character, or a character was input instead of a number.

ILLEGAL MACRO CMD VIA MDI

A paramacro command that cannot be used in MDI mode was programmed. This also can include an illegal sub-program return M99 code.

ILLEGAL MASTER AXIS NAME

Slave axes that do not have a master have been configured for a dual group OR you have assigned a $ axis name as a group master. Axis names beginning with a $ can not be assigned as the master axis for a dual group (first logical axis assigned to the group).

ILLEGAL PAL PRIORITY MESSAGE

This error message displays each time your PAL logic program attempts to save a machine error message that contains dynamic data in the error log. Contact your system installer for assistance with this problem.

ILLEGAL PASSWORD

A password was entered that was not assigned to one of the 8 different password levels. Make sure that no one has changed the passwords by using {ACCESS CONTRL}.

ILLEGAL PLANE - USING SLAVE AXIS

This is a power turn-on message. When using dual axes, one of the slave axes was AMPed as part of the plane configuration. Only master can be used in the plane configuration.

ILLEGAL PLANE DEFINITION

The axis plane assignment made in AMP is incorrect. It can also occur if the two axes assigned to a plane have the same axis name.

ILLEGAL PROGRAMMED RETURN GROUP

The tool group programmed in an M06 block must be the currently active tool group that is being replaced (not the tool group you are changing to). This requirement is configured in AMP by the system installer.

ILLEGAL PROGRAMMED RETURN TOOL

The tool number programmed in an M06 block must be the currently active tool number that is being replaced (not the tool number you are changing to). This requirement is configured in AMP by the system installer.

16-18

Page 839

Section 16 Error and System Messages

Message

Description

ILLEGAL RANDOM TOOL TABLE ASSIGNMENT

An attempt was made to program a G10.1L20 block that would assign a tool to a tool pocket that already has a tool assigned to it.

ILLEGAL RECIPROCATION INTERVAL

The programmed reciprocating interval is greater than the total rollover distance.

ILLEGAL ROTATION PLANE SELECTED

When using the external part rotation feature, the external part rotation plane selected on the rotation parameter screen is not the currently active plane in the program block being executed.

ILLEGAL SPINDLE PROCESS NUMBER

An illegal process number was used to indicate a process that uses one of the spindles.

INCOMPATIBLE PAL SOURCE

The PAL search monitor utility can not be accessed. The PAL search monitor utility requires PAL program built with a newer version of ODS.

INCOMPATIBLE TOOL ACTIVATION MODES

This message is displayed and the control is held in E-Stop at power up when the tool geometry offset mode is “Immediate Shift/Immediate Move”and the tool wear offset mode is “Immediate Shift/Delay Move” or when the tool geometry offset mode is “Immediate Shift/Delay Move”and the tool wear offset mode is “Immediate Shift/Immediate Move”. These modes are incompatible. You must correct your AMP configuration and re-download AMP.

INCORRECT NUMBER OF SYMBOLS

An error occurred in G05 DH+ communications block.

INPUT DATA TOO LONG

The data input has a number of characters exceeding the allowable number of characters.

INPUT STRING SYNTAX ERROR

An attempt was made to search for an illegal character string, or no character string was entered.

INSUFFICIENT MEMORY FOR PAL PROGRAM

An attempt was made to load a PAL program that exceeded the PAL storage space limit allotted by the flash memory.

INSUFFICIENT MEMORY FOR PART PROGRAM

There is not enough available memory for the current program to be stored. Any attempt to store the program in memory will be aborted by the control.

INTEGRANDS FOR DUALS MUST BE THE SAME

This is a power turn-on message. When using dual axes, all integrands of the dual group must use the same letter.

INTEGRANDS FOR NON-MASTER MUST BE NONE

An axis integrand name was configured in AMP that corresponds to an axis in a dual axis group that is not the master axis of that group. Only the master axis in a dual axis group can have a corresponding axis integrand name.

INTEGRANDS NOT AMPED PROPERLY

The axis integrand names were not configured properly in AMP. Refer to your AMP manual for additional details on axis integrand names.

INTERF CHECKING ZONE TABLE CORRUPTED

The zone tables used by interference checking have an invalid checksum and were cleared.

INTERNAL COMMUNICATIONS ERROR

Communication failed. Contact Allen-Bradley customer support services.

INTERRUPT NOT RECOGNIZED

An interrupt macro was not acted on for some reason. An example would be if an interrupt occurred in the middle of another interrupt.

INVAL LOOP BASE

An attempt was made to configure ports TB2 and TB3 as postion/velocity loop or digital or digital spindle.

INVALID AMP-DEFINED G CODE

An attempt was made to assign the same G-code to different macro calls. This message appears after AMP is downloaded and the control does secondary calculations.

INVALID AMP LETTER FORMAT

The programmed word or parameter has an invalid letter format defined in AMP. Since ODS AMP detects and prohibits invalid formats, this error usually indicates that an invalid format was entered through patch AMP. Refer to your AMP reference manual for details.

INVALID ARC-COSINE ARGUMENT

An attempt was made to calculate or execute a paramacro block that calculates the arc cosine of an invalid or improperly entered number.

INVALID ARC-SINE ARGUMENT

An attempt was made to calculate or execute a paramacro block that calculates the arc sine of an invalid or improperly entered number. Change cosine to sine.

INVALID ARGUMENT ASSIGNMENT

An invalid argument assignment was programmed.

INVALID AXIS

The axis programmed in the adaptive depth (G26) or adaptive feedrate (G25) block is invalid. Valid axis names for programming these features are defined in AMP.

16-19

Page 840

Section 16 Error and System Messages

Message

Description

INVALID AXIS FOR CSS

The CSS axis (the axis that is perpendicular to the center-line of the rotating part) is not a valid axis on the control. This usually occurs when the CSS axis is changed from the default axis by programming a P-word in the G96 block that selects some other axis.

INVALID AXIS PROGRAMMING RESOLUTIONS

The axis resolutions set in AMP by the system installer are too far apart. The control is incapable of handling large differences in axis resolutions. For example, if the X axis has a resolution that allows .999999 and the Z axis allows a resolution of only .9, the control can have difficulty moving both axes simultaneously.

INVALID CCT INDEX

An error occurred in G05 DH+ communications block.

INVALID CHANNEL NAME

An error occurred in G05 DH+ communications block.

INVALID CHARACTER

A program name has been entered that contains an illegal special character.

INVALID CHECKSUM DETECTED

This error is common for several different situations. Most typically it results when writing or restoring invalid data to flash memory. For example if axis calibration data is being restored to flash and there was an error or invalid memory reference in the axis calibration data file. Typically this indicates a corrupt or invalid file.

INVALID CNC FILENAME

An error occurred in G05 DH+ communications block.

INVALID CODE PROGRAMMED FOR 7300

An invalid G or M code was programmed during 7300 tape compatibility mode.

INVALID COMMUNICATIONS PARAMETER

Parameters in G05 and/or G10.2 communication blocks are incorrect.

INVALID CONTROL FOR DUAL PROCESS SYS

The system executive downloaded to the control does not match the hardware configuration established by your option chip.

INVALID CUTTER COMPENSATION NUMBER

A compensation number (or TTRC number) out of the range of allowable compensation numbers (either too large or too small) was programmed.

INVALID CYCLE PROFILE

The path defining the cycle profile is not valid. This is typically caused by the cutter radius being set to the wrong sign, being set too large, or the values for U, W, I, K, and the cutter radius combined are not valid for the profile to be cut.

INVALID DATA AFTER A MACRO COMMAND

Typically caused by a non-paramacro command following a paramacro command. Macro and non-macro commands cannot exist in the same block.

INVALID DATA BEFORE A MACRO COMMAND

Typically caused by a non-paramacro command preceding a paramacro command. Macro and non-macro commands cannot exist in the same block.

INVALID DATA FORMAT MUST BE MM/DD/YY

An invalid date format was entered. The format must be Month / Day / Year (MM/DD/YY).

INVALID DEPTH PROBE CONTROLLING AXIS

The axis name which is AMPed as the controlling axis for the depth axis is not an axis that has been configured on the system or the adaptive depth controlling axis is configured as the same axis defined to have depth probe feedback. Refer to your AMP reference manual for details on axis configuration.

INVALID DESKEW MASTER

The AMPed name specifying the master deskew servo is not one of the AMPed axes.

INVALID DESKEW SLAVE

The AMPed name specifying the master deskew servo is not one of the AMPed axes, or it has already selected as a master axis.

INVALID DH COMMAND TYPE

An error occurred in G05 DH+ communications block.

INVALID (DO) COMMAND NUMBER

The specified loop number in a paramacro DO command is out of the legal range, or not found. DO commands must be followed by a 1, 2, or 3.

INVALID (END) COMMAND NUMBER

A paramacro END command has been encountered without a matching DO or WHILE, or outside the valid range. END commands must be followed by a 1, 2, or 3, as programmed with the corresponding DO command.

INVALID ENDPOINT IN G27 BLOCK

The position programmed in the G27 block is not the home position. The end-point of a G27 block must be the machine home position.

INVALID EXPECTED LIFE

The data just entered for the expected life of the cutting tool for tool management is invalid.

INVALID EXPECTED TOOL LIFE

The current program is attempting to enter an invalid value for the tool management expected life of a tool. Tool life is programmed in a G10 block with an L-word.

16-20

Page 841

Section 16 Error and System Messages

Message

Description

INVALID FB COUNTS

At power up the control checks the AMP configured position and velocity feedback counts per revolution. If either of these parameters are invalid (for this hardware type) this error appears and the control is held in E- Stop.

INVALID FDBK/MTR TYPE COMBO

When changing between an executive from system 9.xx to 10.xx some major changes occurred to how a servo is configurated in AMP. When copying this AMP project from 9.xx to 10.xx you must open and reconfigure some of the AMP servo group parameters before saving and downloading to the control.

INVALID FILE TYPE

An error has occurred in a file that has been sent from the ODS workstation to the control. Typically it is the result of ODS sending the wrong file type to the control (for example, an AMP file is sent when a PAL download is taking place, etc.). Attempt to download the file again, making sure that the correct file type is selected when downloaded.

INVALID FIXED DRILLING AXIS

The axis selected as the drilling axis is an invalid axis for a drilling application.

INVALID FORMAT SPECIFIED IN B/DPRNT CMD

Improper format was used in the paramacro command (BPRNT or DPRNT) that outputs data to a peripheral device.

INVALID FUNCTION ARGUMENT

An invalid paramacro argument was used in a paramacro function. The argument contains either bad syntax or an illegal value.

INVALID G10 CODE

The format for a G10 block is not correct. Refer to your user manual for the correct format for the G10 block that is currently being programmed.

INVALID IN ANGLED WHEEL MODE

A feature that is not available in G16.3 mode, or G16.4 mode or both has been programmed. Refer to your grinder users manual angled-wheel grinder section for a description of features not available on an angled-wheel grinder.

INVALID INFEED (P WORD)

Infeed value (P-word) is not in valid range. The valid range for a P-word during a threading cycle is whole numbers 1 though 4.

INVALID INPUT VALUE

The data entered is invalid for the current operation being performed.

INVALID INTERFERENCE AREA

A G10 block has programmed a zone where the plus value is less than the minus value.

INVALID INTERFERENCE CHECK AXIS

An axis from the wrong process was AMPed. Unless a shared axis is used in the zone, the axis defined to make up an interference area must be in the process the zone is defined for.

INVALID LATHE AXIS

An illegal code was encountered during cylindrical interpolation programming.

INVALID LIFE TYPE

The current program is attempting to enter an invalid tool life type for a tool group in the tool management tables. Valid tool life types are type 0, 1, or 2. Tool life type is programmed in a G10 block following a I-word.

INVALID M99 IN MAIN PROGRAM

An M99 part program rewind and auto start was programmed in the middle of the main program. An M99 can be programmed only at the end of a part program.

INVALID MACRO COMMAND

The IS and IM commands are reserved for use by the control only for program interrupts. They cannot be entered in a part program or MDI program.

INVALID MACRO FROM TAPE

You have programmed a paramacro command that cannot be executed from tape.

INVALID NUMBER OF POCKETS

This error occurs when using G10 L20 to enter random tool data and the number of pockets needed for the tool is invalid.

INVALID OFFSET NUMBER

An offset number out of the range of allowable offset numbers (either too large or too small) was programmed.

INVALID OPERATOR IN EXPRESSION

Check expressions to make sure they are correct.

INVALID OPERATOR IN PARAMACRO EXPRESSION

The control has encountered a non-mathematical operator (character) in a paramacro expression or calculate operation.

INVALID OUTPUT FORMAT

An error occurred in G05 DH+ communications block.

INVALID PARAMACRO ARGUMENT ASSIGNMENT

An argument assignment in a block that calls a paramacro program contains either an invalid argument specification or a syntax error was made in the argument.

INVALID PARAMETER NUMBER

An attempt was made to assign or read the value of a paramacro parameter that does not exist.

16-21

Page 842

Section 16 Error and System Messages

Message

Description

INVALID PARAMETER VALUE

An attempt was made to assign an invalid value (typically too large or too small of a value) to a paramacro parameter.

INVALID POCKET NUMBER

An attempt was made to enter a tool pocket number that exceeds the allowable number of tool pockets in the random tool table. This error occurs when a P-word that is too large or too small is programmed in a G10.1L20 block.

INVALID POCKET PROFILE

An invalid pocket profile was programmed in a lathe roughing or finishing cycle.

INVALID POSITION FB TYPE

System was incorrectly AMPed with a Yaskawa type encoder (absolute or incremental) on the position feedback device when separate position and velocity feedback devices are used.

INVALID PROGRAM NUMBER (P)

A program number called by a sub-program or paramacro call is invalid. A P-word that calls a sub-program or paramacro can only be an all-numeric program name as many as 5 digits long. The O-word preceding the numeric program number in control memory cannot be entered with the P-word.

INVALID REMOTE NODE NAME

An error occurred in G05 DH+ communications block.

INVALID REMOTE STATION TYPE

An error occurred in G05 DH+ communications block.

INVALID REPEAT COUNT (L)

An L parameter that programs the number of times a paramacro or other operation is to be repeated was programmed incorrectly or out of the legal range. The L-word for repeat count must be a whole, positive number. Decimal values and negative values are invalid. The maximum value of an L-word is 9999.

INVALID ROUGHING CYCLE (P/Q) WORD VALUE

When executing a roughing cycle, the starting or ending sequence number of the contour defining blocks cannot be found in the currently executing program. The sequence number of the contour blocks is programmed using the P and Q words. These blocks can be anywhere in the program provided they are resident in the same program, sub-program, or paramacro program that contains the calling block.

INVALID SCALE FACTOR (P-WORD)

An invalid scale factor has been specified. The P-word has a range of 0.0001 to 999.99999.

INVALID SERVO HARDWARE TYPE

The AMP servo parameter that selects the servo type does not match the hardware found on the control when the AMP file is downloaded. Either AMP is misconfigured or the servo hardware installed on your system is not correctly installed or not of the correct type.

INVALID SHAFT POCKET

When entering a custom tool in the random tool table, an attempt was made to assign a shaft pocket position that is not in the range of the number of pockets assigned to the tool. The shaft pocket number must be equal to or less than the number assigned for the number of pockets.

INVALID SHAFT POCKET VALUE

A program is attempting to enter a custom tool in the random tool table with a invalid shaft pocket position (not in the range of the number of pockets assigned to the tool). The shaft pocket number must be equal to or less than the number assigned for the number of pockets. The shaft pocket value is assigned in a G10.1 block following the R-word.

INVALID SPCMD VALUE

A invalid special command error typically occurs when the servo PROMs are not compatible with the main processor PROMs. Check the software version numbers and contact Allen-Bradley customer support services.

INVALID SYMBOL NAME

An error occurred in G05 DH+ communications block.

INVALID T-CODE FORMAT

This is an invalid T-Code Format

INVALID_THREAD_ANGLE

An attempt was made to program an angle that is outside the allowable range, which is 0 through 120 degrees.

INVALID THRESHOLD RATE

An invalid threshold percentage was entered for a tool group while setting tool management data. The threshold percentage must range between 0 and 100 percent. Only whole positive numbers can be entered. If using a G10 block, the threshold percentage is entered with a Q-word.

INVALID TIME FORMAT MUST BE HH:MM:SS

An invalid time format was entered. The time format must be hour / minute / second (HH/MM/SS).

INVALID TOOL AXIS

This is an invalid Tool Axis.

16-22

Page 843

Section 16 Error and System Messages

Message

Description

INVALID TOOL CUTTER COMPENSATION NUMBER

An attempt was made to enter a tool radius offset number, for cutter compensation or TTRC, in the tool life management table that is larger than the maximum offset number allowed. If the tables are being loaded by a G10 program, the radius offset is entered with a D-word in the block.

INVALID TOOL DIAMETER VALUE

An invalid tool diameter value was entered in a program block.

INVALID TOOL GROUP

An attempt was made to create a tool group greater than 200 in the tool management tables. A maximum of 200 tool groups can be used. If loading the tables using a G10 program, the tool group number is entered using a P-word.

INVALID TOOL LENGTH OFFSET NUMBER

An attempt was made to enter a tool length offset number in the tool life management table that is larger than the maximum offset number allowed. If the tables are being loaded by a G10 program, the length offset number is entered with a H-word in the block.

INVALID TOOL LIFE TYPE

An attempt was made to enter an invalid tool life type for a tool group in the tool management tables. Valid tool life types are type 0, 1, or 2.

INVALID TOOL NUMBER

Either no tool or an invalid tool number was programmed in a random tool G10.1 block. Tools should be programmed with a Q-word in a G10.1 block or within a range determined by the system installer in AMP. An invalid tool number was entered into the tool management tables or was programmed in a part program block.

INVALID TOOL NUMBER FROM PAL

The PAL offset change feature specified an invalid tool number to the control.

INVALID TOOL ORIENTATION

This is an invalid tool orientation.

INVALID TOOL TABLE TYPE

This is an invalid tool table type.

INVALID VALUE ZONE 3

A zone 3 value was entered that is outside of the zone 3 limits.

INVALID VALUE ZONE 3:

The zone listed has values that are outside of the zone limits.

INVALID VELOCITY FDBK TYPE

AMP for your digital drive system has been configured for an invalid velocity loop hardware type. Valid values for digital systems are NO FEEDBACK, ABSOLUTE FEEDBACK, and INC ENCODER ON DIGITAL MODULE. Other selections are invalid on digital systems.

INVALID WHEEL ANGLE

An invalid wheel angle has been entered for the angled wheel grinder. Wheel angles must be entered between 0 and 180 degrees. Also wheel angles that approach 90 degrees are also invalid.

INVALID WORD IN G10L3 MODE

An attempt was made to assign a parameter that is not a legal parameter in the G10L3 mode. G10L3 assigns data to the tool management tables.

INVALID WORD IN G11 BLOCK

An invalid word was programmed in a G11 block that cancels the data setting mode for the tool management tables. The G11 code must be programmed in a block that contains no other data.

INVALID ZONE LIMIT

This is an invalid Zone Limit.

INVALID ’,’WORD

A word other than a chamfering C-word, a radius R-word, or QPP angle word was programmed in a block with a comma “,”. Only the radius and chamfer words can be preceded with a “,”in a block.

IPD AND G16.3/G16.4 CANNOT BE CONCURRENT

This error message is issued when in-process dressing is on and a block containing a G16.3 or G16.4 is activated on a cylindrical grinder in angled wheel configurations.

J JOG WILL CAUSE (+) OVERTRAVEL

An attempt was made to execute an incremental jog that would move the indicated axis beyond its positive software overtravel limit.

JOG WILL CAUSE (-) OVERTRAVEL

An attempt was made to execute an incremental jog that would move the indicated axis beyond its negative software overtravel limit.

JOGGED HOME TOO FAST:

The speed selected for the move to the home limit switch is too fast and the homing operation has failed. Move the axes back to the other side of the limit switch (the side before the homing operation began), and re-execute the homing operation, this time slowing the speed using the <SPEED/MULTIPLY> switch or the <FEEDRATE OVERRIDE> switch.

L

16-23

Page 844

Section 16 Error and System Messages

Message

Description

L VALUE OUT OF RANGE

An L-word repeat count was programmed larger than the system is capable of performing (typically a maximum L of 9999 is permitted). A second block will need to be programmed to duplicate the commands again. Enter a smaller L-word for both blocks.

L-WORD CANNOT BE GREATER THAN TOOL RADIUS

The programmed L-word value in a G88.5 or G88.6 hemispherical pocket cycle is greater than the programmed tool radius. The incremental plunge depth of a hemispherical pocket cycle cannot be greater than the tool radius.

L- WORD OUT OF RANGE

More than 1000 spark-out passes were specified by the L-word in a grinder fixed cycle.

LARGER MEMORY - REFORMAT

This message typically occurs after a new AMP or PAL has just been downloaded to the control. There is now more memory available for the RAM disk, but you need to reformat to use it. If desired, you do not have to reformat RAM and can continue to run the control with the RAM disk at its current size.

LEAD WORD FORMAT FINER THAN

The word format programmed is requesting a finer resolution than the axis word format for the corresponding axis allows. These word formats are set in AMP.

LENGTH OFFSET AXIS MISSING IN PROCESS

You have configured the tool length axis as a shared axis and it is currently not being controlled by the process requesting to activate a tool length offset. The shared length axis must be returned to the process attempting to activate the tool offset. Or tool offsets were programmed for an axis that is configured in AMP as unfitted.

LESS MEMORY - REFORMAT

This message typically occurs after a new AMP or PAL has just been downloaded to the control. There is now less memory available for the RAM disk, and you must reformat to use the RAM disk.

LETTER OR DIGIT MUST FOLLOW $, %, !, &, OR #

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW $, %, ! OR #

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW $, % OR !

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW $, % OR !

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW #

You have used incorrect search string syntax in the PAL search monitor utility.

LIMIT EXTRN DECEL SPEED ON

Dual axes have limited the external decel speed AMP value. An axis in the dual-axis group was AMPed with a lower value.

LIMIT MANUAL DLY CONSTNT ON

Dual axes have limited the manual delay constant AMP value. An axis in the dual-axis group was AMPed with a lower value.

LIMIT MAX CUTTING FEED ON

Dual axes have limited the maximum cutting feedrate AMP value. An axis in the dual-axis group was AMPed with a lower value.

LIMITED ACC/DEC RAMP ON

Dual axes have limited the acc/dec ramp AMP value. An axis in the dual-axis group was AMPed with a lower value.

LIMITED RAPID FEEDRATE ON

Dual axes have limited the rapid feedrate AMP value. An axis in the dual-axis group was AMPed with a lower value.

LIMITED VELOCITY STEP ON

If the velocity step AMP value is not the same for all axes of a dual group, the control will adjust them to the limiting axis.

LOW VOLTAGE ON FLASH STICKS

Call Allen-Bradley Support Services.

LOWER > UPPER

A value entered in the programmable zone table for zone 2 or 3 results in a lower limit value being greater than the upper limit. The upper limit must always be greater than the lower limit. M

M02 OR M30 FOUND - REQUEST TERMINATED

This error occurs if an M02 or M30 is found before the requested block while searching during a mid-program start. The search will be terminated at the M02/M30 block.

MACHINE HOME REQUIRED OR G28

An attempt was made to program an axis move before the axes were homed. Axes can be homed manually or by programming a G28 block.

MASTER HAS TO BE AMPED FIRST

The dual master axis has to be configured first in the AMP data base.

16-24

Page 845

Section 16 Error and System Messages

Message

Description

MASTER ONLY G-CODE - MUST PARK SLAVES

An attempt was made to program a G-code that is not compatible with a dual axes. The programmed G-code can only be applied to the AMP defined master axis of the dual axis group. All other axes in the dual axis group must be parked.

MATH OVERFLOW

Your paramacro or calculator function is requiring a calculation with an excessively large or illegal value.

MAX SIZE EXCEEDED

The programmed number of symbols is too large (the communication data packet is too large).

MAX SOLID TAP RPM EXCEEDS MAX GEAR RPM

The resulting solid taping RPM exceeds the spindles current RPM Maximum for the active gear range. Either change gear ranges, or reduce the tapping speed.

MAXIMUM BLOCK NUMBER REACHED

A renumber operation was performed to renumber block sequence numbers (N-words), and the control has exceeded a block number of N99999. Either the program is too large to renumber, or the parameters for the first sequence number, or the sequence number increment, are too large. When this error occurs, the renumber operation stops renumbering at the last block within the legal range of N-words.

MAXIMUM NUMBER OF AXES EXCEEDED

If the COCOM breakout is true, a maximum of 4 concurrent interpolated axes can be used.

MAXIMUM NUMBER OF PROGRAMS

The RAM disk directory for part program storage is full. You can store only 328 files on the system even when memory is available for part program storage.

MAXIMUM RETRACE COUNT REACHED

The limit (defined in AMP) for the amount of retrace blocks allowed was reached. No further retracing will be allowed.

MAXIMUM REVERSE PLANES EXCEEDED

The order that the axes are named in AMP is important. If, for example, axis one’s name is assigned as X and axis three’s name is assigned as Z, a reverse plane is defined if the G18 plane is assigned in AMP as the ZX plane. The G18 plane defines a plane consisting of axis 3 followed by axis 1, making it a reverse plane (axis 1 followed by axis 3 would be a normal plane since 1 is configured before 3 from the standpoint of ODS). This also pertains to parallel axes. A maximum of four reverse planes is allowed. If your system exceeds this number of reverse planes, you must re-configure your AMP.

MAXIMUM RPM LIMIT AUXILIARY SPINDLE 2

A request was made for the aux spindle 2 speed to exceed the AMPed maximum value. Reduce the programmed aux spindle 2 speed, or use the spindle speed override switch to reduce the RPM.

MAXIMUM RPM LIMIT AUXILIARY SPINDLE 3

A request was made for the aux spindle 3 speed to exceed the AMPed maximum value. Reduce the programmed aux spindle 3 speed, or use the spindle speed override switch to reduce the RPM.

MAXIMUM RPM LIMIT FIRST SPINDLE

A request was made for the spindle 1 speed to exceed the AMPed maximum value. Reduce the programmed spindle 1 speed, or use the spindle speed override switch to reduce the RPM.

MAXIMUM RPM LIMIT PRIMARY SPINDLE

A request was made for the primary spindle speed to exceed the AMPed maximum value. Reduce the programmed primary spindle speed, or use the spindle speed override switch to reduce the RPM.

MAXIMUM RPM LIMIT SECOND SPINDLE

A request was made for the spindle 2 speed to exceed the AMPed maximum value. Reduce the programmed spindle 2 speed, or use the spindle speed override switch to reduce the RPM.

MAXIMUM RPM LIMIT THIRD SPINDLE

A request was made for the spindle 3 speed to exceed the AMPed maximum value. Reduce the programmed spindle 3 speed, or use the spindle speed override switch to reduce the RPM.

MESSAGE PENDING, PRESS A KEY TO DISPLAY

The 9/Series screen saver is engaged and a system error message, PAL error message, E-Stop condition, or PAL display page has been activated. Press any key on the keyboard to disable the screen saver and view the error or PAL display page.

MDI INPUT COMMAND TOO LONG

The MDI input command string exceeds the maximum length allowed.

MDI NOT ALLOWED DURING INTERRUPT MACRO

An attempt was made to halt the execution of a interrupt program and execute a MDI command. MDI commands cannot be executed during the execution of a interrupt program.

MDI NOT ALLOWED DURING POCKET MILLING

An MDI command cannot be programmed while a G88 or G89 pocket milling cycle is executing.

MDI NOT ALLOWED DURING RETRACE

You cannot use MDI while a retrace operation is in progress.

MEASUREMENT POINT OVERFLOW

The user tried to enter more points into online AMP for axis calibration than are permitted.