Page 862
Section 16 Error and System Messages
Message
Description
STORING TO BACKUP - PLEASE WAIT
This message appears whenever AMP or axis calibration data in RAM is being stored in backup memory.
SYMBOL NAME FORMAT ERROR
Check the remote symbol and CNC symbol to make sure they exist on both remote and CNC. Check the table of the read only or write only variables.
SYMBOL NOT FOUND
Check the remote symbol and CNC symbol to make sure they exist on both remote and CNC. Check the table of the read only or write only variables.
SYNCHRONIZATION DEADLOCK
A synchronization code is activated and caused the activating process to wait on a process that is already waiting.
SYNCH SPINDLES MISCONFIGURED
Causes for this could be: only one spindle (either controlling or follower) was defined in the synchronized spindle pair, you exceeded the simple feedback ratio limitation of 10 (e.g., 11:1 or 2:13), or on a multiprocess system, one (or both) of the spindles in the synch pair is currently not available to the process making the synchronization request.
SYNCH SPINDLES REQUIRE FEEDBACK
One or both of the spindles, configured in AMP as a member of a synchronized pair, did not have feedback. Both spindles in a synchronized pair must be equipped with an AMP configured feedback device.
SYNTAX ERROR (COMMA)
A missing comma or an extra comma was found in the program block.
SYSTEM DIAGNOSTIC #1
An illegal parameter was passed into a switch statement (mid-program start) in the control software. Contact Allen-Bradley customer support services.
SYSTEM DIAGNOSTIC #2
An illegal parameter was passed into a switch statement (ASCII buffer task) in the control software. Contact Allen-Bradley customer support services.
SYSTEM DIAGNOSTIC #3
An illegal parameter was passed into a switch statement (ASCII buffer task) in the control software. Contact Allen-Bradley customer support services.
SYSTEM MODULE CONFIG ERROR
In the “Smart “1394 power supplies, the CNC sends configuration data to the power supply. These values are read back by the CNC for verification. This fault message indicates a mismatch between the two values. This mandates that the system module power supply be replaced.
SYSTEM MODULE GROUND FAULT
The 1394 system module has detected a ground fault. The system generates a ground fault when there is an imbalance in the DC bus of greater than 50 A. This drive error can be caused by incorrect wiring (verify motor and ground wiring), motor malfunction, or an axis module IGBT malfunction.
SYSTEM MODULE CURRENT LIMIT WARNING
The system module has reached 80% of it’s RMS Bus current capabilities. You may need to reduce the acc /dec profiles or increase the size of the system module. The CNC system will not take action based on this fault, However the machine logic (PAL) can take action based on this status.
SYSTEM MODULE MIS MATCH
This error indicates an AMP value is set in error on a 1394 “smart”power system module. You may have set some of the “system wide” parameters differently between two axes that exist on a single 1394 platform.
SYSTEM MODULE OVER CURRENT
The system module has reached the limit of its current capabilities. The total motoring and regeneration current produced has exceeded the current capability of the system module by 5% or more. You may need to reduce the acc /dec profiles or increase the size of the system module.
SYSTEM MODULE OVER TEMP
The 1394 contains a thermal sensor which senses the internal ambient temperature. Causes could be that : The cabinet ambient temperature is above the 70 deg C rating. The machine duty cycle requires an RMS current exceeding the continuous rating of the controller. The airflow access to the 1394 is limited or blocked. An axis module or a system module FAN has failed. This does not necessarily indicate a motor over temperature. Motor over temperture sensors should be wired directly into the E-Stop string.
16-42
Page 863
Section 16 Error and System Messages
Message
Description
SYSTEM MODULE OVER VOLTAGE
The 1394 system module buss voltage exceeds the maximum operating voltage. The DC power bus is continuously monitored. If it exceeds a preset level (810V DC), a fault is sensed and the power supply is disabled. There are several possible causes for this error. ·an undersized shunt requirement ·a blown shunt regulator fuse ·a malfunctioning shunt regulator transistor ·the power driver board is malfunctioning and incorrectly sensing the bus voltage ·an incorrectly set CNC acc/dec rate ·an excessive input line voltage ·the system inertia is too high causing excessive energy to be returned to the power supply bus ·a vertical axis with insufficient counterbalancing is overdriving the servomotor and causing excessive energy to be returned to the power supply bus ·an incorrect power supply is installed in your system. Make sure you are using a CNC power supply
SYSTEM MODULE PHASE LOSS
The 1394 system module has detected a loss of one of the input power phases. The three- phase input line is monitored and a fault will be issued when a phase loss is detected. Typical causes include, One, two , or all three input line fuses opened, contactor malfunction, or incorrect wiring.
SYSTEM MODULE PRE- CHARGE
The DC bus voltage did not rise to operating levels (285 V) within .5 sec after 3 phase power was applied to the system. This can occur if : a short is detected on the DC bus . An axis is enabled before the pre- charge check is complete, or if torque is commanded before full bus voltage is present.
SYSTEM MODULE SHUNT TIMEOUT WARNING
The shunt resistor has absorbed 80% of the rated regeneration energy produced by the motor. In general this warning message will not cause any action to be taken by the CNC system, however the logic program can take action based on this status.
SYSTEM MODULE SHUNT TIMEOUT
The shunt resistor has timed out due to an amount of regeneration energy produced by the motor exceeding the limit of the shunt resistor by more than 5%. You may require a properly sized shunt, modification of the duty cycle of the application, or the addition of an external shunt for additional capacity.
SYSTEM MODULE UNDER VOLTAGE
The 1394 system module voltage does not meet the minimum operating voltage. The DC power buss shall activate the under voltage limit when the bus drops to 275 VDC or less. It will clear at 300 Vdc. Typical causes include low voltage on the three phase input.
T (T) WORD IN CIRCULAR MODE
An attempt was made to activate a tool length offset in a block that generates a circular move. Tool length offsets can be activated only in linear blocks (or in non-motion blocks if AMP is so configured).
T- WORD NOT ALLOWED WITH M06
NEXT TOOL IN T WORD was selected as the tool- change type in AMP while a T- word is programmed in an M06 block.
TAN CIRCLE NOT IN 1ST BLOCK
When editing a program, an attempt was made to digitize an arc using {CIRCLE TANGNT} as the first block in the program. To use this digitizing format, the control must first have a tool path programmed to make the arc tangent.
TEMPLATE PROGRAM NOT FOUND
A transfer line quick view item was selected without the correct part program template present in the protected directory. There are 19 transfer line cycles and there must be part program templates QV01 thru QV19 present in the protected directory. Refer to your T-LINE-9 Quick Start guide for details on replacing/restoring these part program templates.
THIRD SPINDLE NOT AVAILABLE
AMP configuration error; spindle 3 can be configured only on a 9/290.
THIRD SPINDLE NOT CONFIGURED
For spindle 3 to be programmable, it must be configured in AMP; a decode error.
THRDS/IN WORD FORMAT FINER THAN
The word format programmed is requesting a finer resolution than the axis word format for the corresponding axis allows. These word formats are set in AMP.
THREAD FEEDRATE TOO LARGE
The lead is too large in threading mode. Program slower spindle speed.
16-43
Page 864
Section 16 Error and System Messages
Message
Description
THREAD LEAD ERROR
The thread lead was too large or too small. This commonly occurs when cutting a variable thread lead and before the end of the threading pass is reached. Either the lead goes to zero for a decreasing lead thread, or an axis speed would exceed its maximum allowable cutting feedrate when cutting an increasing lead thread.
THREAD LEAD IS ZERO
No thread lead has been programmed in a block that calls for thread cutting. Thread lead is programmed with either an F- or an E-word.
THREAD PULLOUT DISTANCE TOO LARGE
The programmed threading pullout distance is larger than the programmed distance of the thread departure.
THREAD PULLOUT STOPPED AT I- PLANE
The chamfer block of a threading cycle is shortened so that the combination of pullout angle and pullout distance does not cause the retract in axis 1 to go beyond the I- plane. The AMP pullout angle is still used for the chamfer.
THREADING DISTANCE IS ZERO
A threading cycle has been programmed with no thread. Program an end-point or an end-point different from the start-point.
TIME-OUT OCCURRED WHILE WAITING FOR INPUT
When downloading AMP or PAL from the ODS workstation to the control, the message OKAY TO DOWNLOAD? (Y/N): appears on the control screen. If you do not respond within an allowed time, this error will appear.
TIMER MUST START WITH #
You have used incorrect search string syntax in the PAL search monitor utility.
TOO MANY ( [ ) IN EXPRESSION
The control has found an unmatched number of [] in a program block or calculator operation. All left brackets “[”must have a corresponding right bracket “]”.
TOO MANY ( ] ) IN EXPRESSION
The control has found an unmatched number of [] in a program block or calculator operation. All right brackets “]”must have a corresponding left bracket “[”.
TOO MANY 7300 PATTERNS IN MEMORY
An attempt was made to enter a 7300 pattern into the control’s memory when the internal cross-reference table of pattern repeat names was full. The internal cross-reference table of pattern repeat names can only hold 20 pattern repeat names.
TOO MANY ACTIVE PROCESSES CONFIGURED
An AMP has been loaded that has too many actively configured processes for this controller model. The 260 series and the dual lathe can have only 2 active processes.
TOO MANY AXES AMPED FOR HARDWARE
An AMP has been loaded that has too many configured axes for this controller model. The 9/440 series can have only up to 6 axes.
TOO MANY AXES PROGRAMMED
Too many axis letters were programmed in a fixed cycle block.
TOO MANY AXES SELECTED FOR DISPLAY
When using the {AXIS SELECT} softkey, you can display only 6 axes. If you attempt to display more than 6 axes, this message is displayed.
TOO MANY CODES IN SYNCH BLOCK
Synch codes must be in a block by themselves, except for an N- or O-word. (9/260-9/290 dual lathe only)
TOO MANY DECIMAL POINTS
A word or parameter value has been programmed with two or more decimal points.
TOO MANY DEVICES ON I/O RING
The I/O ring cannot support the number of devices that has been connected.
TOO MANY EXPRESSION NESTS
The maximum number of nested expressions is 25; for example, [P3+[P4+[P5]]] has 3 expressions nests.
TOO MANY G67’S
A G67 cancel modal paramacro code was executed when no modal paramacro was active. This is typically caused when there are fewer nested modal paramacros than the programmer expected.
TOO MANY I-J-K SETS
An attempt was made to define a local paramacro parameter that is greater than #33 using I,J,K, argument sets. A maximum of 10 different I, J, K, sets may be programmed for each set of local parameters.
TOO MANY MACRO CALLS
The maximum number of nested paramacros was reached. Only 4 paramacros can be active at any one time.
TOO MANY MOTORS AMPED ON 1ST BOARD
The AMP parameter for the number of motors on the first servo board is larger than the number of axes in the system.
16-44
Page 865
Section 16 Error and System Messages
Message
Description
TOO MANY NESTED (DO) COMMANDS
More than the allowable number paramacro DO loops are active at one time. A maximum of 3 nested DO loops are allowed.
TOO MANY NONMOTION BLOCKS-DEADLOCK
There were too many non-motion blocks encountered during the look-ahead for cutter compensation or QPP. Consult Allen-Bradley customer support services.
TOO MANY NONMOTION CHAMFER/RADIUS BLOCKS
Too many non-motion blocks separate the first tool path that determines the chamfer or radius size (programmed with a ,R or ,C) from the second tool path. A maximum number of non-motion blocks is set in AMP by the system installer. A non-motion block is defined as any block that does not generate axis motion in the current plane.
TOO MANY POCKETS IN ROUGHING CYCLE
A maximum of 2 pockets can exist in a roughing cycle.
TOO MANY QPP NONMOTION BLOCKS
Too many non-motion blocks separate the first and second tool paths with unknown intersections in QuickPath Plus. A maximum number of non-motion blocks is set in AMP by the system installer. A non-motion block is defined as any block that does not generate axis motion in the current plane.
TOO MANY SHARED SPINDLES
Too many spindles were specified as being shared by two or more processes.
TOO MANY SPINDLES
More than one spindle is configured on the control.
TOO MANY SUBPROGRAM CALLS
The maximum number of nested sub-programs was reached. Only 4 sub-programs may be active at any one time.
TOOL CONFIGURATION WILL NOT FIT
When assigning a custom tool in the random tool table, the number of pockets assigned to the tool relative to the position of the selected shaft pocket will conflict with a different tool already assigned to a pocket. If the custom tool is to be assigned as entered, it must be assigned to a different shaft pocket, or the tool that conflicts with the custom tools location must be moved.
TOOL ENTRY EXCEEDS LIMIT
The selected tool number entered is greater than the AMP’ed maximum tool number entered by the system installer.
TOOL GROUP DOES NOT EXIST
An attempt was made to edit a tool group in the tool life management tables that does not yet exist in the tool directory. A group must be created by using the {TOOL DIR} softkey options.
TOOL OFFSET CHANGES NOT ALLOWED
During certain cycles, G10 tool change operations are not allowed.
TOOL OFFSET REQUIRES MOTION BLOCK
A tool offset cannot be changed in a non-motion block. A non-motion block is any block that does not generate axis motion in the current plane.
TOOL RADIUS TOO LARGE
The programmed tool radius in a G88 or G89 pocket cycle is too large for the pocket contour. A smaller radius tool must be used to machine out the current pocket contour.
TOOL RADIUS TOO SMALL FOR POCKET SIZE
The programmed tool radius in a G88 or G89 pocket cycle is too small for the pocket contour. Either select a larger tool for the pocket contour or reduce the amount of material to be removed each rough cut of the cycle.
TOP OF PROGRAM REACHED
When performing one of the program search operations, the first block in the program has been reached.
TRAVERSE NOT ALLOWED ON :
An attempt was made to move an axis at rapid traverse before it was been homed. This only applies to axes that have software overtravel limits.
TYPE 1 INTERRUPT INCOMPATIBLE WITH G24
This message occurs when returning from a type 1 program interrupt that previously interrupted a G24 block. The interrupt is allowed however the return move is invalid since the axis was previously in the G24 mode. You must manually intervene to continue program execution. We recommend switching to a type 2 program interrupt.
U UART PORT IS ALREADY OPEN
The requested serial communications port has already been opened. This message will appear if an attempt is made to send data to a port that is currently being used.
UNABLE TO OPEN PROGRAM
The control cannot find the program that is requested. Make sure the program name is entered correctly or the peripheral device has the correct programs loaded in it.
16-45
Page 866
Section 16 Error and System Messages
Message
Description
UNABLE TO OPEN THE UART PORT
A serial communication port error has occurred; retry. The conditions that can lead to this error are unusual and generally will not exist when a second attempt is made to open the port. If this error is generated continuously, it indicates that there may be a communications port hardware failure.
UNABLE TO SYNCH IN CURRENT MODE
The control can not perform the request to synchronize spindles. Possible causes are: synchronization is already active; virtual/cylindrical programming or a threading operation is active on the primary or follower spindle when the synchronization request is made; or on a dual- process system, one of the requesting processes cannot gain control over both spindles.
UNABLE TO WRITE TO FLASH MEMORY
If flash SIMMs appear to be installed correctly, remove and reseat SIMMs. If problem persists, contact Allen- Bradley support service.
UNDEFINED INTERRUPT MACRO/SUBPROG
An interrupt program request was received by the control, but it cannot find the paramacro or sub-program with the corresponding program name in the program directory. The program name is defined in the enable block (M96) with a P-word.
UNEXPECTED DEPTH PROBE TRIP
G26 adaptive depth probe has fired unexpectedly. Either it has fired in a non-G26 block or it has fired before the programmed G26 contact range.
UNSPECIFIED NETWORK ERROR
An error is being sent from another device that the module cannot interpret.
UNUSABLE WORDS IN ZONE BLOCK
An axis word or other data was programmed in a programmable zone block (G22, G22.1 G23, G23.1). These G-codes must be programmed in blocks containing no other data except a block delete /, N word, or comments.
UNRECOVERABLE ERROR
Can occur when updating flash SIMMs with new 9/Series firmware. Retry the update utility. If problem persists, call Allen-Bradley Support Services.
V VEL LOOP INVALID WITH DAC OUT
An attempt was made to select the position/velocity servo loop type on a 9/440HR system.
VIRTUAL AXIS NOT ALLOWED
The virtual axis can only be programmed when the control is in a virtual axis mode. You must place the control in G16.3 mode to program a virtual axis.
VIRTUAL C NEEDS SPINDLE WITH FDBK
When the spindle is the virtual C axis in a virtual C application, it must be configured to provide feedback to the servo module.
VIRTUAL/REAL AXIS NAME CONFLICT
The axis configured in AMP as the Virtual C axis was previously configured as a linear machine axis.
W WARNING - G10 OFFSETS ALTERED
This message warns that the offsets were changed by a G10 block during execution from a mid-program start.
WARNING - PROGRAM STARTING AT BEGINNING
An active program was edited and then the editor exited. This causes the active program to restart at the beginning of the program.
WARNING - VERIFY MODAL CODES
The MID START PROGRAM feature that activates modal codes for mid-program execution is requesting that these generated modal codes be checked before program execution is started. These modal codes can be checked on the G- and M-code status screens.
WARNING - WATCHDOG JUMPER IS INSTALLED
This error indicates that the watchdog has been bypassed on the 9/Series hardware and your system will not report watchdog errors. Call Allen-Bradley field service.
WHEEL AXIS MOTION INVALID IN G16.3/G16.4
While in the angled wheel grinding mode you have attempted to program the wheel axis directly. Only the virtual axis and the axial axis can be programmed in angled wheel mode.
WILDCARD MUST BE AT START/END OF SYMBOL
You have used incorrect search string syntax in the PAL search monitor utility.
WORK CO-ORD CHANGES NOT ALLOWED
You have attempted to make a change to the work coordinate system at an invalid time. Changes to the work coordinate system can not be performed when some features are active. Disable the offending feature before attempting to change coordinate systems.
16-46
Page 867
Section 16 Error and System Messages
Message
Description
Z Z-WORD CANNOT BE GREATER THAN R-WORD
The depth (Z-word) of a pocket formed using a G88.5 and G88.6 hemispherical pocket cycle cannot be greater than the radius (R-word) of that pocket.
ZONE 2 PROGRAM ERROR
The next block in the program or MDI entry would cause the specified axis to enter the restricted area of programmable zone 2.
ZONE 2 PROGRAM ERROR:
The current block in the program or MDI entry caused the specified axis to enter the restricted area of programmable zone 2.
ZONE 3 PROGRAM ERROR
The next block in the program or MDI entry would cause the specified axis to enter or exit the area defined as programmable zone 3.
ZONE 3 PROGRAM ERROR:
The current block in the program or MDI entry caused the specified axis to enter the restricted area of programmable zone 3.
END OF APPENDIX
16-47
Page 868
Section 16 Error and System Messages
16-48
Page 869
Page 870