The text of a manual · part 89 of 91
9/Series CNC Hardware Integration and Maintenance Manual, pages 872 to 881
Pages 872 to 881 of 898
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 8500-1746I
Page 872
Index 9/Series Integration and Maintenance Manual ii
Page 873
Section
17
Installing 9/Series Hardware for CE Compliance
17.0 Complying with European Union Directives
If your system is installed within the European Union, EEA regions, or has the CE mark, the following regulations apply:
EMC Directive This device is tested to meet Council Directive 89/336 Electromagnetic Compatibility (EMC) using a technical construction file and the following standards, in whole or in part: EN 50081--2 EMC -- Generic Emission Standard, Part 2 -- Industrial Environment EN 50082--2 EMC -- Generic Immunity Standard, Part 2 -- Industrial Environment The products described in this manual are intended for industrial use in an industrial environment. Use this table as a guide to determine what you need to know about your CE compliant Allen-Bradley product.
Low- voltage Directive This device is tested to meet Council Directive 73/23/EEC Low--voltage, by applying the safety requirements of EN 61131--2 Programmable Controllers, Part 2 -- Equipment Requirements of Tests. For specific information required by EN--61131--2, refer to the following Allen--Bradley publications: Industrial Automation Wiring and Grounding Guidelines for Noise Immunity, publication 1770--4.1 Guidelines for Handling Lithium Batteries, publication AG--5.4 Automation Systems Catalog, publication B111
17-1
Page 874
Section 17 Installing 9/Series for CE Compliance
17.1 Wiring AC Power for a CE Compliant System
If you are integrating a 9/Series that has a final destination within Europe you must attach a metal oxide varistor (MOV) to all connections that carry AC power to the system. If you have this control:
then you need to connect a varistor to:
9/230, 9/260 or 9/290 the incoming AC connection on the power supply
9/440 the incoming AC connection on the ON/OFF module
The types of MOV that you need are: AC Power Voltage 90-130 V AC
Manufacturer Harris
Part Number V130LA20B
130-265V AC
V275LA40B
These devices are available through several vendors, including Newark Electronics. They can be contacted at: Country
Phone Number
United Kingdom
(0420) 5433333
France
(1) 30-90-59-90
Germany
02 15 4-9 59 60
USA
312-784-5100
Here is an example of a typical MOV varistor connector on the 9/440 ON/OFF Control Module: ON/OFF Power Control Module
AC IN
L1
AC power source
C02
High
Low AC power source
L2 PE L1 AUX AC
L2 ON SW
COMMON OFF SW
17-2
Ground
Page 875
Section 17 Installing 9/Series Hardware for CE Compliance
Filtering Power for a 9/440 System To comply with CE guidelines you need to connect a power line filter to cable C55. The type of filter you need is: Product
Part Number
Manufacturer
Phone Number
Power Line Filter
MIF323-GS
Roxburgh Electronics LTD Foxhills Industrial Park Scuntharpe South Humberside, DN158Q5 United Kingdom
011-44-017-242-81770
Connect the power line filter to C55 as shown: Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C55
9/440
External 380/460V Three Phase
Drive Power
9/440 System Module Power Terminal Block
Prepared by Customer
9/440 Power Strip
Bussman FRS- R- 20A (min) 600 V AC FRS-R-30A (max) 600V AC or equivalent (qty 3)
Three-phase input 380-460V AC
DC+
INT
COL
W1
W2
U
V
W
C55
PE
LOAD
LINE
Power Line Filter AC Bulletin 100- A30N x 3 (surge protector required) or DC Bulletin 100- A30NZ x 3
Bulletin 100 Contactor Power
Noise suppressor
E-STOP Status Contactor (customer supplied or internal 9/440 TB1 status)
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
See Local Codes (12Awg max)
Clamped by terminal screws
Line Drop Limitation
17-3
Page 876
Section 17 Installing 9/Series for CE Compliance
17.2 Wiring a High-Density I/O Module for CE Compliance
If you are using a High Density I/O module, you must wire all inputs and all outputs on the module with MOV varistors for surge protection. Here’s the type of MOV you need: DC Power Voltage
Manufacturer
24 V DC
Part Number
Harris
V392A6
This device is available through several vendors, including Newark Electronics. They can be contacted at: Country
Phone Number
United Kingdom
(0420) 5433333
France
(1) 30-90-59-90
Germany
02 15 4-9 59 60
USA
312-784-5100
Here is an example of a typical input and output connection on the high density I/O module that uses MOV varistors: CN61M or CN62M
Typical Input or Output
Terminal Board
1
1
2 3 4
G 2 G 3 G 4 G
33 34
Share current between the four “common”pins
17-4
35 36 37
C
MOV varistor
I/O Device
Page 877
Section 17 Installing 9/Series Hardware for CE Compliance
17.3 Wiring E-stop for CE Compliance
A CE compliant system must have noise-reducing components as part of its emergency stop wiring. When connecting E-stop to a 9/Series, place the ferrite suppressor core as close to the control as possible, as shown in these drawings: Figure 17.1 E-STOP Component Connection
E-STOP status relay
CR
E-STOP reset button
E-STOP button
Note: To meet CE compliance, the E- stop wire must pass through the suppressor core twice.
Pluggable E-STOP Connector
1 E-STOP 2 Common
On MTB panel
3 Reset 4
Customer E-STOP string E-STOP status relay contact connection
5 6
CR
+
7 8* customer supplied fuse (size to protect K1b contact and your E-Stop status relay) Ferrite Suppressor Core
*Important: If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
17-5
Page 878
Section 17 Installing 9/Series for CE Compliance
Figure 17.2 Typical Emergency Stop Circuit MTB PANEL
Reset button
Motherboard/Processor Board
E-STOP button
1
250mA 15 V dc from main power supply
Reduced to 12 V dc filter
2 K1A
3
MACHINE Extreme overtravel switches
Remote E-STOP button
4
Drive System Ready
5
Software
CR controlled Motor thermal switches may be connected directly
DRIVES ENCLOSURE
-
E-STOP status relay
Customer-supplied dc power
+
7 customer supplied fuse (size to protect K1b contact and your E-Stop status relay)
E-STOP
6
CR
Ferrite Suppressor Core
8
Contactors for E-STOP status controlled devices (servo amp contactor, indicators, brakes, coolant pumps, etc.)
circuit
K1B E-STOP relay K1 12 V dc coil Contact ratings: 30 V dc 1.4 A common
Important: If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
SYSTEM INSTALLER OPTIONS
Ferrite suppression cores can be aquired through several vendors, including Dexter Magnetic Materials Division (DMMD): Country
Phone
Germany
089-857-3071
United Kingdom
0753-680011
United States
1-800-345-4082
Ferrite Suppression Core Specification 250W @ 100 MHz
17-6
Manufacturer
Part Number
Fair- Rite Corporation
0443164151
Newark
95F 762
Page 879
Section 17 Installing 9/Series Hardware for CE Compliance
17.4 Modifying the Video Cable for CE Compliance
To meet CE compliance, a ferrite suppression core has to be installed around the video cable. Place the ferrite suppression core as close to the monitor as possible, as shown in this drawing:
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C09
9/260 or 9/290
Motherboard J8
Video Signal Cable
Prepared by Customer
9/260 or 9/290
Processor Board J8
CN19M on Operator Panel or on Portable Operator Panel Interface Assembly
9/440
System Module J8 1 2 3 4 5 6 7 8
9 10 11 12 13 14
N.C. N.C.
N.C. N.C.
N.C. N.C. N.C. N.C. N.C. N.C.
N.C. N.C. N.C. N.C. N.C. N.C.
15
1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
Monochrome monitor
1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
Color monitor
Ferrite Suppressor Core 1 2 3 4 5 6 7 8
9 10 11 12 13 14
N.C. N.C. N.C. N.C.
N.C. N.C. N.C. N.C.
15
Ferrite Suppressor Core Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
15 Pin D-Shell (has pins) 8520-D15M
Belden 9503 (monochrome) Belden 9505 (color)
15 Pin D-Shell (has sockets) 8520-D15F
15m (50 ft)
17-7
Page 880
Section 17 Installing 9/Series for CE Compliance
Ferrite suppression cores can be aquired through several vendors, including Dexter Magnetic Materials Division (DMMD): Country
Phone
Germany
089-857-3071
United Kingdom
0753-680011
United States
1-800-345-4082
Ferrite Suppression Core 250W @ 100 MHz
17-8
Manufacturer
Part Number
Fair- Rite Corporation
0443164151
Newark
95F 762
Page 881
Section 17 Installing 9/Series Hardware for CE Compliance
17.5 1394 and 9/440 CE Requirements Enclosure
Ground Conduit to Enclosure Three- Phase Mains with Ground
Schaffner (or equivalent) E Filter
Conduit Clamp User- Supplied 24V Power Source Three- Phase Contactor
System PE Bus Enclosure
Note 1
360°shield termination at Enclosure by user. If you are using a 9/440 with optional feedback capability, 360° shielding is needed.
Resolver Feedback Cables
END OF APPENDIX
17-9