Pico GFX-70 Controllers User Manual: 5 - Visualization with Pico GFX-70, pages 289 to 298

Pages 289 to 298 of 400, from Pico GFX-70 Controllers User Manual

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley GFX-70 1760-DUB

Page 289

Visualization with Pico GFX-70

5-21

Table 5.14 Numerical value and output formats Left column

Right column

Numerical value 1 • Value range: 0 to 50000 • Unit: None • Scaling range: None • Always show sign: No

Numerical value 1 • Value range: 0 to 4000 • Unit: None • Scaling range: 0 to 4 • Decimal places: 0 • Always show sign: No

Numerical value 2 • Value range: 0 to 50000 • Unit: ms • Scaling range: None • Always show sign: No

Numerical value 2 • Value range: 0 to 4000 • Unit: s • Scaling range: 0 to 4 • Decimal place: 1 • Always show sign: No

Numerical value 3 • Value range: 0 to 50000 • Unit: ms • Scaling range: None • Always show sign: Yes

Numerical value 3 • Value range: 0 to 4000 • Unit: s • Scaling range: 0 to 4 • Decimal places: 2 • Always show sign: Yes

Figure 5.15 Output formats Timer 4 1873 2 1873ms 1.9s +1873ms +1.87s

Screen 2 - Screen 2 shows a simple example of the visualization of timing relay times using the function block parameter (FB parameter) from the Associated variable tab. The screen contains three numerical values. These are associated with the QV output of timing relay T04.

Table 5.16 Numerical value – visualization of timing relay times Numerical value 1:

Start value of the timing relay T04 FB parameter: I2 (zero as input I2 is not assigned with on-delayed relays!)

Numerical value 2:

Setpoint of the timing relay T04 FB parameter: I1 (4000 as input I1 is assigned with the constant 4 s (= 4000 ms) in the function block editor)

Numerical value 3:

Actual value of the timing relay T04 FB parameter: QV (display of value present at the function block output)

In order for the values to be displayed meaningfully, “ms” (milliseconds) is entered in the Unit of measure field in the Number range/format tab.

Publication 1760-UM002B-EN-P - March 2005

Page 290

5-22

Visualization with Pico GFX-70

Figure 5.17 Timing relay times Start Val 0ms Setpoint 4000ms Act Val 1452ms

Screen 3 - Screen 3 shows an example of outputting analog values (here IA3) on the display. Note the Scaling range field on the Number range/format tab. The screen contains three numerical value that output the analog value in different formats. The values are associated with the analog input IA3 (Associated variable tab) which has a value provided as a DWord variable at the QV output (FB parameter). All numerical values are assigned a value range from 0 to 1019 as this scan range is defined by the connected potentiometer. Table 5.18 Numerical value - analog value output Numerical value 1:

Display of the analog value (0 to 1019)

Numerical value 2:

Display of the analog value with the scaling range 0 to 10, two decimal places, unit of measure “V” (Volt)

Numerical value 3:

Display of the analog value with the scaling range –5 to +5, two decimal places, unit of measure “V” (Volt), signed

Figure 5.19 Analog value output Analog input I3 Figure 358 0 to 10 3.51V -5to+5 -1.49V

Screen 4 - Screen 4 shows an example of the output of analog values (here IA3) on the display which is an extension of screen 3. For greater simplicity, all the basic settings of the scaling range were taken from screen 3. Note the Numerical display setting in the Display change area of the Number range/format tab. Table 5.20 Numerical value - extended analog value output

Publication 1760-UM002B-EN-P - March 2005

Numerical value 1:

Display of the analog value (0 to 1019)

Numerical value 2:

Display of the analog value with the scaling range 0 to 10, two decimal places; unit of measure "V" (Volt); Always show sign: yes; Display change - Detection via: internal limit value comparison; Numerical display: flashing

Numerical value 3:

Display of the analog value with the scaling range –5 to +5, two decimal places, unit of measure "V" (Volt); Always show sign: no; Display change - detection via: internal limit value comparison; Numerical value display: inverted

Page 291

Visualization with Pico GFX-70

5-23

Figure 5.21 Extended analog value output Analog input I3 Figure 0 Flashing +0.00V Invert -5.00V

Screen 5 - Screen 5 shows an example of the output of analog values (here IA3) on the display with the visibility option switched via I1 and I2. The settings for this were defined on the Visibility tab. Two numerical values are shown on the screen that output the analog value in different formats. These values are associated with analog input IA3 which provides a Word type variable for further processing. Table 5.22 Numerical value – analog value output with invisibility activated Numerical value 1:

Display of the analog value with the scaling range 0 to 10; two decimal places; Unit of measure "V" (Volt); make number invisible via Boolean operand I1; make contact bit logic (Visibility tab)

Numerical value 2:

Display of the analog value with the scaling range –5 to +5; two decimal places; Unit of measure "V" (Volt); make number invisible via Boolean operand I2; make contact bit logic (Visibility tab)

Figure 5.23 Make invisible function Invisibility via I1 via I2

1.29V

Screen 6 - Screen 6 shows a simple example of the display change using an external trigger. In this example input I1 is the external trigger. The screen contains two numerical values. These are associated with the output QV of timing relay T08 which is a DWord type variable. The timing relay is run in a loop from 0 to 10 seconds. Table 5.24 Numerical value – analog value output with display change via external trigger input General settings:

Value range from 0 to 11000; unit of measure: s (seconds); scaling range from 0 to 11, two decimal places; display change active; detection via external trigger input

Left numerical value:

Display of timing relay value T08, I1 actuated: the numerical value flashes as the external trigger is set for flashing display via Boolean operand I1

Right numerical value:

Display of timing relay value T08; I1 actuated: the numerical value is inverted as the external trigger is set for inverted display via Boolean operand I1

Publication 1760-UM002B-EN-P - March 2005

Page 292

5-24

Visualization with Pico GFX-70

Figure 5.25 External trigger Display change (I1) external trigger 3.37s 3.37s

Screen 7 - Screen 7 shows a simple example of the display change using an internal limit value comparison. The screen shows two numerical values that show the output values (QV output) of the timing relay T08. The variable type is DWord. The timing relay is run in a loop from 0 to 10 seconds. A value range from 0 to 11000 is defined in the Number range/format tab. The unit of measure is set to “s” (seconds). The scaling range is defined from 0 to 11 with 2 decimal places. The display change is active and is detected via the internal limit value comparison. The numerical value display flashes for the left numerical value and is inverted for the right numerical value.

Table 5.26 Numerical value – analog value output with display change via internal limit value comparison Left numerical value:

The numerical value flashes in the range from 0 to 3 and from 7 to 10. The upper limit value is set to 7 (the display change occurs from numerical value 7 to 10) in the Display change tab and the lower limit value is set to 3 (the display change occurs from numerical value 0 to 3). There is therefore no display change between 3 and 7.

Right numerical value:

The numerical value is inverted in the range from 0 to 3 and from 7 to 10. The upper limit value is set to 7 (the display change occurs from numerical value 7 to 10) in the Display change tab and the lower limit value is set to 3 (the display change occurs from numerical value 0 to 3). There is therefore no display change between 3 and 7.

Figure 5.27 Display change via internal limit value comparison

Display Marker word1(C1)

16

No display change

Display change

Display change (without 3-7s) internal trigger 6.57s 6.57s

Display change (without 3-7s) internal trigger 0.95s 0.95s

Screen 8 - Screen 8 shows an example of outputting a marker word. The numerical value in the screen is associated with marker word MW01. The variable type is Word. A value range from 0 to 999 is defined in the Number range/format tab. The timing relay T09 switches the counter C01 (refer to the circuit diagram in PicoSoft Pro.) every two seconds. The output QV of the counter function block writes the data to marker word MW01 (defined in the Parameters tab in the Function block output area). If the upper switch value SH (38) is reached, the counter resets itself.

Publication 1760-UM002B-EN-P - March 2005

Page 293

Visualization with Pico GFX-70

TIP

Overflow signal Timer 4

---ms

Underflow signal Counter 2

-mm

5-25

In PicoSoft Pro, the contents of the marker can be viewed both in decimal and hexadecimal format. Only decimal format, however, is shown in the display.

Screen 9 - Screen 9 shows an example of how to display a value overflow. The associated variable is the QV output of timing relay T04. The variable type is DWord. The timing relay runs from 0 to 4000 ms. A value range from 0 to 3000 and “ms” as unit of measure are defined in the Number range/format tab. This causes a value overflow as soon as 3000 ms is exceeded. This is indicated in the display by an overflow signal. Screen 10 - Screen 10 shows an example of how to display a value underflow. The associated variable is the QV output of counter C02. The variable type is DWord. The counter C02 is triggered by a flashing pulse from timing relay T07. The counter counts down from 12 to 0. A value range from 6 to 12 and “mm” as unit of measure are defined in the Number range/format tab. This causes a value underflow as soon as 6 mm is undershot. This is indicated in the display by an underflow signal.

Value Entry This screen element enables you to enter numerical setpoint values on the device during operation and thus make interventions in a process. The process value is thus entered via the set variable linked in the program. The Pico GFX-70 saves the entered value internally. The value is processed by the program and displayed until it is modified again by the operator or the program. Without an operator entry this screen element functions like the numerical value screen element and therefore displays the value of the associated set variable. When you start to enter a value on the Pico GFX-70 device, the entry field shows the last variable value. You start the entry by pressing OK. This activates Selection mode in which you can use the cursor buttons to move between the value entry elements of a screen. The order of the selected elements is from the back to the front. This order is defined by their positioning and can be altered in the toolbar. Pressing OK once more activates Entry mode.

Value and Scaling Range The value range defines the range that is to be displayed. If the values are below or above this range, the Pico GFX-70 activates an underflow or overflow signal.

Publication 1760-UM002B-EN-P - March 2005

Page 294

5-26

Visualization with Pico GFX-70

The scaling range is used for scaling the value range. The lower and upper values of the scaling range are assigned to the lower and upper values of the value range respectively. The Pico GFX-70 displays the value range if a scaling range has not been defined. Examples

In order, for example, to display the value range (0 to 255) of a counter as a percentage (0 to 100 %), enter “0” as the minimum value and “255” as the maximum value in the Value range field. Enter “%” as the unit of measure. Activate the Scaling range field and enter “0” as the minimum value and “100” as the maximum value. In order, for example, to display the value range (0 to 120) of a timing relay in minutes (0 to 2 min), enter “0” as the minimum value and “120” as the maximum value in the Value range field. Enter “min” as the unit of measure. Enter “0” in the activated Scaling range field as the minimum value and “120” as the maximum value.

Programming in PicoSoft Pro 1. Hold down the left mouse button and drag the Value entry screen element into the screen. 2. Position the mouse over the screen element and move it to the required position with the left mouse button depressed. The height of the screen element frame depends on the font size selected. Three sizes are available: • Normal font • Double font • Quadruple font You can change the font size by activating the context menu (right mouse button) or by dragging the selection handle at the bottom edge of the element frame concerned. When increasing the font size, ensure that there is sufficient space available underneath the element. The width of the screen element frame can be scaled as required by dragging the selection handle on the sides. Set variable tab - On the Set variable tab you define the Boolean variable you wish to set.

Publication 1760-UM002B-EN-P - March 2005

Page 295

Visualization with Pico GFX-70

5-27

Number range/format tab - The Number range/format tab is used for defining the following: • Value range • Unit of measure • Scaling range • Input format The display of the value sign can be forced. Visibility tab - The Visibility tab enables you to make the screen element invisible via an associated variable. Operability tab - In the Operability tab, select the associated variable for disabling the entry element. Value Entry Example Program

The program consists of seven screens that can be selected using the up and down cursor buttons. The screen change was defined in the Button editor (see Button Editor on page 5-37). When the Pico GFX-70 is in RUN mode, you can change values that are processed in the program by using the up/down and left/right cursor buttons. The Pico GFX-70 shows the actual values in the display. In order to change values, the Pico GFX-70 must first switch to Selection mode. In Selection mode you can select the value entry element containing the values you wish to change. 1. Press OK to switch the Pico GFX-70 to Selection mode. Use ESC to exit Selection mode. The selected value entry element will flash. If several value entry elements are present, use the up/down and left/right cursor buttons to select the required element (see Screen 7). 2. Press the OK button to move from Selection mode to Entry mode. 3. Move to the required position using the left and right cursor buttons, change the value with the up and down cursor buttons. 4. Accept the modified value by pressing OK. Press ESC if you wish to retain the previous value. In both cases you return to Selection mode and can exit by pressing ESC.

Publication 1760-UM002B-EN-P - March 2005

Page 296

5-28

Visualization with Pico GFX-70

The circuit diagram contains timing relay T01 which triggers counter C02. When the counter reaches the upper switch threshold SH, it switches output Q1 to 1. The value of the counter's function block output QV is transferred to marker word MW06. The upper setpoint SH is associated with marker word MW07 and the preset actual value SV with marker word MW05. In RUN mode, the marker words are where the actual data is stored and where new data is written via the value entry elements. The counter can be reset at any time via input I2. I1 (rising edge) is used to accept the value in marker word MW05 as a new preset actual value SV. As there is no setpoint value in marker word MW07 (switch value for Q1) when the program is started, this is interpreted as switch value “zero”, and output Q1 is switched immediately to 1. Standard path: C:\Program Files\PicoSoft 6 Pro\samples\ Program: Value entry_manual screen change.e60 Switch val Q1(OK) Act val 99

100

Screen 1 - Screen 1 illustrates the value entry option using the set variable marker word MW07 (switch value for Q1). The value entry element is enlarged on the display. A value range from 0 to 9999 and Allow digit selection as input format are defined in the Number range/format tab. Input I01 is assigned make contact bit logic in the Operability tab. The value is written to marker word 7 and accepted by counter input SH. Q1 is set to 1 if the counter actual value QV is greater than or equal to the upper setpoint SH. If the actual value already has a higher value than the switch value you can reset the counter via I2. Q1 is immediately reset to 0 and is not active again until the switch value is reached. Screen 2 - Screen 2 illustrates the activation of the value entry via the set variable marker word MW05 (preset actual value SV). After you have entered a new value, this is written to marker word MW05 by actuating I1. This is associated with the preset actual value SV of counter C02. When transferred, the actual value QV switches to the SV value entered and continues counting from this value. Figure 5.28 Transfer of value when I1 closes Set entry: 80

QV 304

Set Entry(OK) 80 Transfer I1

Transfer of value

QV 80

Set Entry(OK) 80 Transfer I1

Screen 3 - Screen 3 shows an example from the Number range/format tab, particularly the Scaling range area and Input format area r Allow digit selection. You can enter any value from 0.00 to 10.00 (Allow digit selection). After I1 closes, the preset actual value SV is transferred. When transferred, the actual value QV switches to the SV value entered and continues counting from this value. The maximum scaling range (10.00) is assigned to the maximum

Publication 1760-UM002B-EN-P - March 2005

Page 297

Visualization with Pico GFX-70

5-29 value range (9999). The value of QV will therefore jump to 9999 when the entered value is 10.00 and I1 is actuated. Figure 5.29 Transfer of value with Allow digit selection set Value entry = 10.00

QV value = 9999

Allow digit selec Set entry QV (OK) 15 10.00

Allow digit selec Set entry QV (OK) 9999 10.00

Screen 4 - Screen 4 shows an example of the Number range/format tab, particularly the Scaling range area and Input format area r Fixed step width. You can enter any value from 0.00 to 10.00 in step widths of 0.50 (fixed step width). After I1 closes, the preset actual value SV is transferred. When transferred, the actual value QV switches to the SV value entered and continues counting from this value. The maximum scaling range (10.00) is assigned to the maximum value range (9999). The value of QV will therefore jump to 9999 when the entered value is 10.00 and I1 is actuated. Figure 5.30 Transfer of value with fixed step width set Value entry

Step width Set entry QV (OK) 16 8.50

Transfer of QV value

Step width Set entry QV (OK) 8500 8.50

Screen 5 - Screen 5 shows an example of the Visibility tab. If I4 is closed, the value entry element is made invisible. The make contact bit logic is set. When using break contact bit logic, this is the same as a “visible circuit”. Even when invisible the element is operable and value entry is still possible. Figure 5.31 Making the value entry element invisible Set value visible

Set value invisible

Set value entry Invisible QV via I4 299 1037

Set value entry Invisible QV via I4 299

Screen 6 - Screen 6 shows an example of the Operability tab. (visibility set as in screen 5.) When I3 closes, the entry function is disabled. Make contact bit logic is selected. If the value entry element is disabled, you can still select it (flashing) but Entry mode (changing values) is disabled. If the value entry element is in Entry mode when I3 closes, the Pico GFX-70 automatically switches to Selection mode. When using break contact bit logic, entry is only possible if I3 is actuated. The value entry element is made invisible via I4. However, it is still operable and values can still be modified.

Publication 1760-UM002B-EN-P - March 2005

Page 298

5-30

Visualization with Pico GFX-70

Figure 5.32 Value entry element disabled I3 not actuated

I3 actuated

Set value entry disabled QV via I3 249 1037

Set value entry disabled QV via I3 249 1037

Message Text This screen element can be used to display texts that are stored beforehand in a text table inside the program. A text can have a maximum length of 16 characters. Additional blanks are added to the displayed text if it is shorter than the element. A message text is used for indicating status changes in the process. In order to visually indicate changes of this kind, you can link message texts with a variable (associated variable). When the variable concerned assumes a specified value, the Pico GFX-70 outputs the appropriate message text. The default text is output if the variable assumes a value that is not assigned to a text.

Programming in PicoSoft Pro 1. Hold down the left mouse button and drag the Message text screen element into the screen. 2. Position the mouse over the screen element and move it to the required position with the left mouse button depressed. The height of the screen element frame depends on the font size selected. Two sizes are available: • Normal font size • Double font size You can change the font size by activating the context menu (right mouse button) or by dragging the selection handle at the bottom edge of the element frame concerned. When increasing the font size, ensure that there is sufficient space available underneath the element. The width of the screen element frame can be scaled as required by dragging the selection handle on the sides.

TIP

Publication 1760-UM002B-EN-P - March 2005

Ensure that the screen elements are sufficiently large for containing the corresponding text of all languages selected. This can be checked easily in the screen overview.