Page 389

Specifications

List of the Function Blocks

A-17

Table A.18 Function Block Definitions Element

Meaning of abbreviation

Function block designation

Page

A

Analog comparator

Analog comparator/threshold value switch

4-40

AR

Arithmetic

Arithmetic

4-43

BC block compare

Data block comparison

4-47

BT block transfer

Data block transfer

4-54

BV

Boolean value

Boolean operation

4-64

C counter counter relay

4-68

CF counter frequency

Frequency counter

4-75

CH counter high-speed

High-speed counter

4-79

CI counter incremental value encoder incremental encoder counter

4-85

CP comparators

Comparator

4-90

D display

Text function block

4-92

DB data block

Data block

4-93

DC

DDC controller (direct digital PID controller control)

4-95

FT filter

PT1 signal smoothing filter

4-101

GT

GET

GET value from the network

4-95

HW hora(lat) week

7-day time switch

4-106

HY hora(lat) year

Year time switch

4-111

LS linear scaling

Value scaling

4-115

MR master reset

Master reset

4-122

NC numeric coding

Numerical converter

4-123

OT operating time

Operating hours counter

4-129

PT

PUT

PUT value to the network

4-130

PW pulse width modulation

Pulse width modulation

4-132

SC synchronize clocks

Synchronize time via network

4-135

ST set time

Set cycle time

4-137

T timing relays

Timing relay

4-139

VC value capsuling

Value limitation

4-152

Jumps

4-119

:

Publication 1760-UM002B-EN-P - March 2005

Page 390

A-18

Specifications

Table A.19 Function Block Coils Coil

Meaning of abbreviation

Description

C_ count input

Counter input

D_ direction input

Count up/down indicator

ED enable Differential component

Activate differential component

EI enable integral component

Activate integral component

EN enable

Enable module

EP enable proportional component

Activate proportional component

RE reset

Reset actual value to zero

SE set enable

Set to a predefined value

ST stop

STOP block processing

T_ trigger

Trigger coil

Table A.20 Function Block Contacts

Publication 1760-UM002B-EN-P - March 2005

Contact

Meaning of abbreviation

Description

CY carry

Status “1”, if the value range is exceeded; (carry)

E1 error 1

Error 1, dependent on function block

E2 error 2

Error 2, dependent on function block

E3 error 3

Error 3, dependent on function block

EQ equal

Comparison result, status 1 if values equal.

FB fall below

Status “1”, if the actual value is less than or equal to the lower set point value;

GT greater than

Status 1 if the value at I1 > I2;

LI limit indicator

Value range manipulated variable exceeded

LT less than

Status 1 if the value at I1 < I2;

OF overflow

Status “1”, if the actual value is greater than or equal to the upper set point value;

Q1 output (Q1)

Switch output

QV output value

Current actual value of the function block (e.g. counter value)

ZE zero

Status “1”, if the value of the element input QV is equal to zero;

Page 391

Specifications

A-19

Table A.21 Function Block Inputs (Constants and Operands) Input

Meaning of abbreviation

Description

F1

Factor 1

Gain factor for I1 (I1 = F1 x Value)

F2

Factor 2

Gain factor for I2 (I2 = F2 x Value)

HY

Hysteresis

Switching hysteresis for value I2 (Value HY applies to positive and negative hysteresis.)

I1

Input 1

1st input word

I2

Input 2

2nd input word

KP

Standard

Proportional gain

ME

Minimum make time

Minimum make time

MV manual value

Manual manipulated variable

NO numbers of elements

Number of elements

OS

Offset

Offset for the value I1

PD

Period duration

Period duration

SH

Setpoint high

Upper limit value

SL

Setpoint low

Lower limit value

SV

Set value

Defined actual value (Preset)

TC

Scan time

TG

Recovery time

TN

Standard

Rate time

TV

Standard

Reset time

X1

X1, interpolation point 1 abscissa

Lower value of source range

X2

Interpolation point 2 abscissa

Upper value of source range

Y1

Interpolation point 1 ordinate

Lower value of target range

Y2

Interpolation point 2 ordinate

Upper value of target range

Table A.22 Function Block Output (Operands) Input

Meaning of abbreviation

Description

QV

Output value

Output value

Publication 1760-UM002B-EN-P - March 2005

Page 392

A-20

Specifications

Table A.23 Other Operands Other operands

Description

MB

Marker byte (8-bit value)

IA

Analog input (if available on device)

MW

Marker word (16-bit value)

QA

Analog output (if available on device)

MD

Marker double word (32-bit value)

NU

Constant (number), value range from -2147483648 to +2147483647

Memory Requirement

The following table provides an overview of the memory requirement of the circuit connections, function blocks and their respective constants:

Table A.24 Pico Standard Memory Requirement Space requirement in Bytes per circuit connection/function block per constant on the function block input

20

-

A

68

4

AR

40

4

BC

48

4

BT

48

4

BV

40

4

C

52

4

CF

40

4

CH

52

4

CI

52

4

CP

32

4

D

160

DC

96

4

DB

36

4

FT

56

4

GT

28

HW

68

4 (per channel)

HY

68

4 (per channel)

LS

64

4

LS

64

4

Circuit connection Function blocks

Publication 1760-UM002B-EN-P - March 2005

Page 393

Specifications

A-21

Table A.24 Pico Standard Memory Requirement Space requirement in Bytes per circuit connection/function block per constant on the function block input

MR

20

NC

32

4

OT

36

4

PT

36

4

PW

48

4

SC

20

ST

24

4

T

48

4

VC

40

4

:

-

-

Publication 1760-UM002B-EN-P - March 2005

Page 394

A-22

Specifications

Publication 1760-UM002B-EN-P - March 2005