Page 389
Specifications
List of the Function Blocks
A-17
Table A.18 Function Block Definitions Element
Meaning of abbreviation
Function block designation
Page
A
Analog comparator
Analog comparator/threshold value switch
4-40
AR
Arithmetic
Arithmetic
4-43
BC block compare
Data block comparison
4-47
BT block transfer
Data block transfer
4-54
BV
Boolean value
Boolean operation
4-64
C counter counter relay
4-68
CF counter frequency
Frequency counter
4-75
CH counter high-speed
High-speed counter
4-79
CI counter incremental value encoder incremental encoder counter
4-85
CP comparators
Comparator
4-90
D display
Text function block
4-92
DB data block
Data block
4-93
DC
DDC controller (direct digital PID controller control)
4-95
FT filter
PT1 signal smoothing filter
4-101
GT
GET
GET value from the network
4-95
HW hora(lat) week
7-day time switch
4-106
HY hora(lat) year
Year time switch
4-111
LS linear scaling
Value scaling
4-115
MR master reset
Master reset
4-122
NC numeric coding
Numerical converter
4-123
OT operating time
Operating hours counter
4-129
PT
PUT
PUT value to the network
4-130
PW pulse width modulation
Pulse width modulation
4-132
SC synchronize clocks
Synchronize time via network
4-135
ST set time
Set cycle time
4-137
T timing relays
Timing relay
4-139
VC value capsuling
Value limitation
4-152
Jumps
4-119
:
Publication 1760-UM002B-EN-P - March 2005
Page 390
A-18
Specifications
Table A.19 Function Block Coils Coil
Meaning of abbreviation
Description
C_ count input
Counter input
D_ direction input
Count up/down indicator
ED enable Differential component
Activate differential component
EI enable integral component
Activate integral component
EN enable
Enable module
EP enable proportional component
Activate proportional component
RE reset
Reset actual value to zero
SE set enable
Set to a predefined value
ST stop
STOP block processing
T_ trigger
Trigger coil
Table A.20 Function Block Contacts
Publication 1760-UM002B-EN-P - March 2005
Contact
Meaning of abbreviation
Description
CY carry
Status “1”, if the value range is exceeded; (carry)
E1 error 1
Error 1, dependent on function block
E2 error 2
Error 2, dependent on function block
E3 error 3
Error 3, dependent on function block
EQ equal
Comparison result, status 1 if values equal.
FB fall below
Status “1”, if the actual value is less than or equal to the lower set point value;
GT greater than
Status 1 if the value at I1 > I2;
LI limit indicator
Value range manipulated variable exceeded
LT less than
Status 1 if the value at I1 < I2;
OF overflow
Status “1”, if the actual value is greater than or equal to the upper set point value;
Q1 output (Q1)
Switch output
QV output value
Current actual value of the function block (e.g. counter value)
ZE zero
Status “1”, if the value of the element input QV is equal to zero;
Page 391
Specifications
A-19
Table A.21 Function Block Inputs (Constants and Operands) Input
Meaning of abbreviation
Description
F1
Factor 1
Gain factor for I1 (I1 = F1 x Value)
F2
Factor 2
Gain factor for I2 (I2 = F2 x Value)
HY
Hysteresis
Switching hysteresis for value I2 (Value HY applies to positive and negative hysteresis.)
I1
Input 1
1st input word
I2
Input 2
2nd input word
KP
Standard
Proportional gain
ME
Minimum make time
Minimum make time
MV manual value
Manual manipulated variable
NO numbers of elements
Number of elements
OS
Offset
Offset for the value I1
PD
Period duration
Period duration
SH
Setpoint high
Upper limit value
SL
Setpoint low
Lower limit value
SV
Set value
Defined actual value (Preset)
TC
Scan time
TG
Recovery time
TN
Standard
Rate time
TV
Standard
Reset time
X1
X1, interpolation point 1 abscissa
Lower value of source range
X2
Interpolation point 2 abscissa
Upper value of source range
Y1
Interpolation point 1 ordinate
Lower value of target range
Y2
Interpolation point 2 ordinate
Upper value of target range
Table A.22 Function Block Output (Operands) Input
Meaning of abbreviation
Description
QV
Output value
Output value
Publication 1760-UM002B-EN-P - March 2005
Page 392
A-20
Specifications
Table A.23 Other Operands Other operands
Description
MB
Marker byte (8-bit value)
IA
Analog input (if available on device)
MW
Marker word (16-bit value)
QA
Analog output (if available on device)
MD
Marker double word (32-bit value)
NU
Constant (number), value range from -2147483648 to +2147483647
Memory Requirement
The following table provides an overview of the memory requirement of the circuit connections, function blocks and their respective constants:
Table A.24 Pico Standard Memory Requirement Space requirement in Bytes per circuit connection/function block per constant on the function block input
20
-
A
68
4
AR
40
4
BC
48
4
BT
48
4
BV
40
4
C
52
4
CF
40
4
CH
52
4
CI
52
4
CP
32
4
D
160
DC
96
4
DB
36
4
FT
56
4
GT
28
HW
68
4 (per channel)
HY
68
4 (per channel)
LS
64
4
LS
64
4
Circuit connection Function blocks
Publication 1760-UM002B-EN-P - March 2005
Page 393
Specifications
A-21
Table A.24 Pico Standard Memory Requirement Space requirement in Bytes per circuit connection/function block per constant on the function block input
MR
20
NC
32
4
OT
36
4
PT
36
4
PW
48
4
SC
20
ST
24
4
T
48
4
VC
40
4
:
-
-
Publication 1760-UM002B-EN-P - March 2005
Page 394
A-22
Specifications
Publication 1760-UM002B-EN-P - March 2005