Spec sheet · AutomationDirect
DL205 PLCs: DC Input Modules
Spec sheet5 pagesPDF 3.1 MB
AutomationDirect DL205 catalog pages with specs for the D2-08ND3 and D2-16ND3-2 DC input modules, ZIPLink wiring and power tables.
What this file really is
The old site listed this file as a spec sheet for the AutomationDirect D2-16ND3-2, D2-32ND3 and 4 more models. Named as a D2-32ND3 spec sheet, these DL205 catalog pages give specifications only for the D2-08ND3 and D2-16ND3-2; the D2-32ND3 appears only in the ZIPLink selector and power tables.
Names · 3 models
The models it names
Filed with · 3 models
Also filed with these models on the old site
Summary
What is in it
Pages from the AutomationDirect DL205 PLC catalog. The first page gives specifications, wiring diagrams and derating charts for the D2-08ND3 (8 inputs) and D2-16ND3-2 (16 inputs) DC input modules. The following pages describe ZIPLink prewired wiring solutions with a selector table that lists the D2-32ND3 among the input modules, and a power requirements section with the power supplied by each DL205 base and the power consumed by each module, including the D2-32ND3.
Its parts
- DC Input
- Wiring Solutions
- ZIPLinks Modules
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Five pages from the AutomationDirect DL205 PLCs catalog: the DC input module specifications for the D2-08ND3 and D2-16ND3-2, the ZIPLink wiring solutions and selector for DL205 I/O, and the DL205 power requirement tables. The D2-32ND3 has no specification page here; it appears only in the ZIPLink selector and the power consumed table.
- D2-16ND3-2 inputs
- D2-16ND3-2: 16 dc inputs, sink/source, 2 isolated commons (8 points per common) p. 1
- D2-16ND3-2 voltage
- D2-16ND3-2: 20-28 VDC; peak 30 VDC (10 mA) p. 1
- D2-16ND3-2 thresholds
- D2-16ND3-2: ON at 19 VDC minimum, OFF at 7VDC maximum p. 1
- D2-16ND3-2 input current
- D2-16ND3-2: 6 mA @ 24 VDC; minimum ON 3.5 mA, maximum OFF 1.5 mA p. 1
- D2-16ND3-2 base power
- D2-16ND3-2: 100 mA at 5VDC from the base p. 1, 5
- D2-16ND3-2 response
- D2-16ND3-2: 3 to 9 ms OFF to ON and ON to OFF p. 1
- D2-16ND3-2 terminal
- D2-16ND3-2: removable terminal block D2-16IOCON, included p. 1
- Weight
- D2-08ND3 and D2-16ND3-2: 2.3 oz. (65 g) each p. 1
- D2-32ND3 base power
- D2-32ND3: 25 mA at 5V, no 24V auxiliary draw p. 5
- D2-32ND3 custom cable
- 32-point modules such as the D2-32ND3: ZL-D24-CON-R ribbon, ZL-D24-CON 180° or ZL-D24-CON-X 45° connector p. 4
- D2-08ND3 inputs
- D2-08ND3: 8 sink/source inputs, 10.2-26.4 VDC, ON at 9.5 VDC minimum p. 1
- D2-08ND3 terminal
- D2-08ND3: removable terminal block D2-8IOCON, included p. 1
- ZIPLink cable lengths
- Cable suffix: blank = 0.5 m, -1 = 1.0 m, -2 = 2.0 m p. 4
What this sheet walks you through
- Choosing a ZIPLink connector module and cable for a DL205 I/O module p. 2, 4
- Connecting DL205 I/O to third party devices with pigtail cables p. 2
- Choosing serial communications cables and specialty ZIPLink modules p. 3
- Calculating the DL205 base power budget p. 5
Good to know
- ZIPLink fuse modules do not include fuses; ZL-RFU20 is rated 2A and ZL-RFU40 400mA per circuit. p. 4
- The DL205 bases also offer a 24 VDC auxiliary supply that can power external devices. p. 5
Questions this sheet answers
What voltage does the D2-16ND3-2 accept?
20-28 VDC, with ON at 19 VDC minimum and OFF at 7VDC maximum. p. 1
Which terminal block fits the D2-16ND3-2?
The removable D2-16IOCON, which is included with the module. p. 1
How much base power does the D2-32ND3 use?
25 mA at 5V and nothing from the 24V auxiliary supply. p. 5
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.