Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of DL205 PLC User Manual, Volume 1 of 2

Manual · AutomationDirect

DL205 PLC User Manual, Volume 1 of 2

Manual598 pagesPDF 12 MB

User manual (Volume 1) for the AutomationDirect DL205 PLC: installation, wiring, I/O module specs, CPUs and system design.

Download the PDF12 MB

Covers · 13 models

The models it covers

Summary

What is in it

Volume 1 of the AutomationDirect DL205 PLC User Manual. It shows how to install, wire, program and maintain DL205 systems, with safety and mounting guidelines, wiring and specifications for each discrete I/O module (including the D2-04TD1, D2-08TD2, D2-16TD2-2, D2-16ND3-2 and D2-32ND3), the DL230, DL240, DL250-1 and DL260 CPUs, memory maps, power budgets, expansion I/O, Modbus and DirectNET networking, ladder and stage programming, PID loops and troubleshooting.

Its parts

  1. Getting Started
  2. Installation, Wiring and Specifications
  3. CPU Specifications and Operations
  4. System Design and Configuration
  5. RLL and Intelligent Box (IBOX) Instructions
  6. Drum Instruction Programming (DL250-1/DL260 only)
  7. RLLPLUS Stage Programming
  8. PID Loop Operation
  9. Maintenance and Troubleshooting

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is volume 1 of the AutomationDirect DL205 PLC User Manual (manual number D2-USER-M), covering the DL205 CPUs, bases, installation, wiring and the discrete I/O modules. It gives the specifications and wiring diagrams of modules including the D2-04TD1, D2-08TD2, D2-16ND3-2, D2-16TD2-2 and D2-32ND3. This summary reads the system overview, environmental specifications and the I/O module pages.

Read for this summary: pages 1, 9 to 11, 34, 52 and 70 to 82 of 598.

System
DL205 modular PLC family: DL230, DL240, DL250-1 and DL260 CPUs with plug-in I/O modules p. 34
Bases
3, 4, 6 and 9 slot, each with a built-in power supply; one slot holds the CPU p. 34, 70
Expansion bases
Bases ending in -1 have a local expansion connector on the right end p. 34
Status indicators
Discrete modules have LED status indicators for the input points p. 71
Humidity
30% to 95% relative humidity, non-condensing p. 52
Terminal blocks
Removable; press the squeeze tabs and pull the block away p. 72
D2-04TD1 outputs
D2-04TD1: 4 current-sinking NMOS FET outputs, 4A/point, 8A/common, 10.2-26.4 VDC p. 80
D2-04TD1 fuses
D2-04TD1: 4 fuses, 1 per point, 6.3 A slow blow, non-replaceable p. 80
D2-04TD1 power
D2-04TD1: 60mA from the 5VDC base supply; external 24VDC at 20 mA max; terminal D2-8IOCON p. 80
D2-16ND3-2 inputs
D2-16ND3-2: 16 sink/source inputs, 2 isolated commons, 20-28 VDC, removable D2-16IOCON terminal p. 74
D2-16ND3-2 power
D2-16ND3-2: 100mA from the 5VDC base supply p. 74
D2-32ND3 inputs
D2-32ND3: 32 sink/source inputs, 4 isolated commons of 8 points; 40-pin connector sold separately p. 75
D2-16TD2-2 outputs
D2-16TD2-2: 16 current-sourcing outputs, 0.1A/point, 1.6A/module p. 82
D2-16TD2-2 power
D2-16TD2-2: 200mA from the 5VDC base supply; removable D2-16IOCON terminal p. 82

What this manual walks you through

  • Choosing a base and understanding slot numbering p. 70
  • Checking where each module type may be placed p. 70
  • Removing and wiring the module connectors p. 72
  • Following the I/O wiring checklist: wire size, torque and fusing p. 73
  • Wiring and specifications of the DC input modules p. 74, 75, 76
  • Wiring and specifications of the DC output modules p. 80, 81, 82
  • Environmental and base power supply specifications p. 52

Good to know

  • Field device power may still be on the terminal block when the PLC is off; check it before removing a connector. p. 72
  • D2-04TD1: a 1A inductive load on for 100 ms may be switched at most 60 times per minute. p. 80
  • Thick or stiff 16 AWG insulation can keep the terminal cover from closing when most points are used. p. 73
  • Adding external fuses to the I/O wiring lowers the risk of a module with a blown fuse. p. 73

Questions this manual answers

What is the current rating of the D2-04TD1 output module?

The D2-04TD1 has 4 current-sinking outputs rated 4A per point and 8A per common, at 10.2-26.4 VDC. p. 80

What fuses does the D2-04TD1 use?

It has 4 fuses, one per point, rated 6.3 A slow blow, and they are not replaceable. p. 80

Does the D2-32ND3 come with a terminal connector?

No. The D2-32ND3 uses a removable 40-pin connector that is sold separately. p. 75

What voltage does the D2-16ND3-2 input module accept?

The D2-16ND3-2 has 16 sink/source inputs for 20-28 VDC, in 2 isolated commons. p. 74

How much base power does the D2-16TD2-2 draw?

The D2-16TD2-2 draws 200mA from the 5VDC base supply. p. 82

The whole text · 60 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 160151-160
  17. Pages 161 to 170161-170
  18. Pages 171 to 180171-180
  19. Pages 181 to 190181-190
  20. Pages 191 to 200191-200
  21. Pages 201 to 210201-210
  22. Pages 211 to 220211-220
  23. Pages 221 to 230221-230
  24. Pages 231 to 240231-240
  25. Pages 241 to 250241-250
  26. Pages 251 to 260251-260
  27. Pages 261 to 270261-270
  28. Pages 271 to 280271-280
  29. Pages 281 to 290281-290
  30. Pages 291 to 300291-300
  31. Pages 301 to 310301-310
  32. Pages 311 to 320311-320
  33. Pages 321 to 330321-330
  34. Pages 331 to 340331-340
  35. Pages 341 to 350341-350
  36. Pages 351 to 360351-360
  37. Pages 361 to 370361-370
  38. Pages 371 to 380371-380
  39. Pages 381 to 390381-390
  40. Pages 391 to 400391-400
  41. Pages 401 to 410401-410
  42. Pages 411 to 420411-420
  43. Pages 421 to 430421-430
  44. Pages 431 to 440431-440
  45. Pages 441 to 450441-450
  46. Pages 451 to 460451-460
  47. Pages 461 to 470461-470
  48. Pages 471 to 480471-480
  49. Pages 481 to 490481-490
  50. Pages 491 to 500491-500
  51. Pages 501 to 510501-510
  52. Pages 511 to 520511-520
  53. Pages 521 to 530521-530
  54. Pages 531 to 540531-540
  55. Pages 541 to 550541-550
  56. Pages 551 to 560551-560
  57. Pages 561 to 570561-570
  58. Pages 571 to 580571-580
  59. Pages 581 to 590581-590
  60. Pages 591 to 598591-598

The file

Revision and size

Part no.D2-USER-M
Revision4th Edition, Rev. D, 10/17
PublisherAutomationDirect
Pages598
PDF12 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.
D2-USER-M

The first pages · 3 of 598

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 598
Page 2
Page 2of 598
Page 3
Page 3of 598

More documents · 1

For the same models