Manual · AutomationDirect
DL205 PLC User Manual, Volume 1 of 2
Manual598 pagesPDF 12 MB
User manual (Volume 1) for the AutomationDirect DL205 PLC: installation, wiring, I/O module specs, CPUs and system design.
Covers · 13 models
The models it covers
Summary
What is in it
Volume 1 of the AutomationDirect DL205 PLC User Manual. It shows how to install, wire, program and maintain DL205 systems, with safety and mounting guidelines, wiring and specifications for each discrete I/O module (including the D2-04TD1, D2-08TD2, D2-16TD2-2, D2-16ND3-2 and D2-32ND3), the DL230, DL240, DL250-1 and DL260 CPUs, memory maps, power budgets, expansion I/O, Modbus and DirectNET networking, ladder and stage programming, PID loops and troubleshooting.
Its parts
- Getting Started
- Installation, Wiring and Specifications
- CPU Specifications and Operations
- System Design and Configuration
- RLL and Intelligent Box (IBOX) Instructions
- Drum Instruction Programming (DL250-1/DL260 only)
- RLLPLUS Stage Programming
- PID Loop Operation
- Maintenance and Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is volume 1 of the AutomationDirect DL205 PLC User Manual (manual number D2-USER-M), covering the DL205 CPUs, bases, installation, wiring and the discrete I/O modules. It gives the specifications and wiring diagrams of modules including the D2-04TD1, D2-08TD2, D2-16ND3-2, D2-16TD2-2 and D2-32ND3. This summary reads the system overview, environmental specifications and the I/O module pages.
- System
- DL205 modular PLC family: DL230, DL240, DL250-1 and DL260 CPUs with plug-in I/O modules p. 34
- Bases
- 3, 4, 6 and 9 slot, each with a built-in power supply; one slot holds the CPU p. 34, 70
- Expansion bases
- Bases ending in -1 have a local expansion connector on the right end p. 34
- Status indicators
- Discrete modules have LED status indicators for the input points p. 71
- Humidity
- 30% to 95% relative humidity, non-condensing p. 52
- Terminal blocks
- Removable; press the squeeze tabs and pull the block away p. 72
- D2-04TD1 outputs
- D2-04TD1: 4 current-sinking NMOS FET outputs, 4A/point, 8A/common, 10.2-26.4 VDC p. 80
- D2-04TD1 fuses
- D2-04TD1: 4 fuses, 1 per point, 6.3 A slow blow, non-replaceable p. 80
- D2-04TD1 power
- D2-04TD1: 60mA from the 5VDC base supply; external 24VDC at 20 mA max; terminal D2-8IOCON p. 80
- D2-16ND3-2 inputs
- D2-16ND3-2: 16 sink/source inputs, 2 isolated commons, 20-28 VDC, removable D2-16IOCON terminal p. 74
- D2-16ND3-2 power
- D2-16ND3-2: 100mA from the 5VDC base supply p. 74
- D2-32ND3 inputs
- D2-32ND3: 32 sink/source inputs, 4 isolated commons of 8 points; 40-pin connector sold separately p. 75
- D2-16TD2-2 outputs
- D2-16TD2-2: 16 current-sourcing outputs, 0.1A/point, 1.6A/module p. 82
- D2-16TD2-2 power
- D2-16TD2-2: 200mA from the 5VDC base supply; removable D2-16IOCON terminal p. 82
What this manual walks you through
- Choosing a base and understanding slot numbering p. 70
- Checking where each module type may be placed p. 70
- Removing and wiring the module connectors p. 72
- Following the I/O wiring checklist: wire size, torque and fusing p. 73
- Wiring and specifications of the DC input modules p. 74, 75, 76
- Wiring and specifications of the DC output modules p. 80, 81, 82
- Environmental and base power supply specifications p. 52
Good to know
- Field device power may still be on the terminal block when the PLC is off; check it before removing a connector. p. 72
- D2-04TD1: a 1A inductive load on for 100 ms may be switched at most 60 times per minute. p. 80
- Thick or stiff 16 AWG insulation can keep the terminal cover from closing when most points are used. p. 73
- Adding external fuses to the I/O wiring lowers the risk of a module with a blown fuse. p. 73
Questions this manual answers
What is the current rating of the D2-04TD1 output module?
The D2-04TD1 has 4 current-sinking outputs rated 4A per point and 8A per common, at 10.2-26.4 VDC. p. 80
What fuses does the D2-04TD1 use?
It has 4 fuses, one per point, rated 6.3 A slow blow, and they are not replaceable. p. 80
Does the D2-32ND3 come with a terminal connector?
No. The D2-32ND3 uses a removable 40-pin connector that is sold separately. p. 75
What voltage does the D2-16ND3-2 input module accept?
The D2-16ND3-2 has 16 sink/source inputs for 20-28 VDC, in 2 isolated commons. p. 74
How much base power does the D2-16TD2-2 draw?
The D2-16TD2-2 draws 200mA from the 5VDC base supply. p. 82
The whole text · 60 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
- Pages 161 to 170161-170
- Pages 171 to 180171-180
- Pages 181 to 190181-190
- Pages 191 to 200191-200
- Pages 201 to 210201-210
- Pages 211 to 220211-220
- Pages 221 to 230221-230
- Pages 231 to 240231-240
- Pages 241 to 250241-250
- Pages 251 to 260251-260
- Pages 261 to 270261-270
- Pages 271 to 280271-280
- Pages 281 to 290281-290
- Pages 291 to 300291-300
- Pages 301 to 310301-310
- Pages 311 to 320311-320
- Pages 321 to 330321-330
- Pages 331 to 340331-340
- Pages 341 to 350341-350
- Pages 351 to 360351-360
- Pages 361 to 370361-370
- Pages 371 to 380371-380
- Pages 381 to 390381-390
- Pages 391 to 400391-400
- Pages 401 to 410401-410
- Pages 411 to 420411-420
- Pages 421 to 430421-430
- Pages 431 to 440431-440
- Pages 441 to 450441-450
- Pages 451 to 460451-460
- Pages 461 to 470461-470
- Pages 471 to 480471-480
- Pages 481 to 490481-490
- Pages 491 to 500491-500
- Pages 501 to 510501-510
- Pages 511 to 520511-520
- Pages 521 to 530521-530
- Pages 531 to 540531-540
- Pages 541 to 550541-550
- Pages 551 to 560551-560
- Pages 561 to 570561-570
- Pages 571 to 580571-580
- Pages 581 to 590581-590
- Pages 591 to 598591-598
The file