DL305 PLCs: DC Output Modules, D3-16TD2 DC Output, pages 1 to 6
Pages 1 to 6 of 6
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AutomationDirect D3-16TD2, Konnect-It D3-16TD2 and Koyo D3-16TD2
Page 1
For the latest prices, please check AutomationDirect.com.
DC Output Modules D3-16TD2 DC Output
$217.00
Outputs per Module
16 (current sourcing)
Commons per Module
2 (isolated)
Operating Voltage
5–24 VDC
Output Type
NPN transistor (emitter follower)
Peak Voltage
40VDC
AC Frequency
N/A
ON Voltage Drop
1.5 V @ 0.5 A
Max. Current
0.5 A/point 3A/common
Max Leakage Current
0.01 mA @ 40VDC
Max Inrush Current
3A/20ms 1A/100ms
Minimum Load
1mA
Base Power Required
9V (180mA max) 7.5 mA/ON pt. 24V N/A
OFF to ON Response
0.1 ms
ON to OFF Response
0.1 ms
Terminal Type
Removable connector
Status Indicators
Logic side
Weight
7.1 oz.(210g)
Fuses
2 (one 5A per common) non-replaceable
See page D3-29 for part numbers of ZIPLink cables and connection modules compatible with this I/O module. Derating Chart
Points 16
0.25A
12 0.5A
8
24VDC OUTP UT D3--16TD2
4
I
0 0 32
10 20 30 40 50 60 ˚C 50 68 86 104 122 140˚ F Ambient Temperature (˚C/˚F )
I
CI
5--24VDC -- + L L L L L L L L
5--24VDC -- +
1 2 4
1
L
3
L L L L
5
4
7
6
6
L L
2
3
CII
L
0
0
0
C
2
1
4 5
3
6 7
5 9VDC
5--24VDC -- +
7
0 4 1 5 2 6 3 7
0 4 II 1 5 2 6 3 7
C 1 3 5 7 0 2 4 6 II
Common 5A
L
Output www.automationdirect.com/dl305
Optical Is olator
DL305 PLCs mDL3-37
Page 2
For the latest prices, please check AutomationDirect.com.
Power Budget Managing your power resource The I/O configuration depends on your choice of I/O modules, bases and I/O location. When determining the types and quantity of I/O modules you will be using, it’s important to remember there is a limited amount of power available from the power supply. The chart on the next page indicates the power supplied and used by each DL305 device. The adjacent chart shows an example of how to calculate the power used by your particular system. These two charts should make it easy for you to determine if the devices you have chosen fit within the power budget of your system configuration. If the I/O you have chosen exceeds the maximum power available from the power supply, you can resolve the problem by shifting some of the modules to an expansion base.
Use ZIPLinks to reduce power requirements If your application requires a lot of relay outputs, consider using the ZIPLink AC or DC relay output modules. These modules can switch high current (10A) loads without putting a load on your base power budget. Refer to the Wiring Solutions section in this catalog for more information. This logo is placed next to I/O modules that are supported by the ZIPLink connection systems. See the I/O module specifications at the end of this section.
WARNING: It is extremely important to calculate the power budget correctly. If you exceed the power budget, the system may operate in an unpredictable manner, which may result in a risk of personal injury or equipment damage.
Example: How to calculate your power usage The following example shows how to calculate the power budget for the DL305 system. The examples are constructed around a single 5-slot base using the devices shown. It is recommended you construct a similar table for each base in your DL305 system. 1. U sing a chart similar to the one below, fill in column 2. 2. U sing the tables on the opposite page, enter the current supplied and used by each device (columns 3, 4, and 5). Devices which fall into the “Other” category (Row D) are devices such as the Handheld Programmer or a Data Communication Unit, which also have power requirements, but do not directly plug into the base.
A
Column 1
Column 2
Base # 0
Device Type
5-slot Base
D3-05BDC
DL305 PLCs
Column 3
Column 4
Column 5
5 VDC (mA)
9VDC (mA)
24V(mA)
1400
800
500
B Current Supplied C Current Required CPU Slot
D3-330
300
50
0
Slot 0
D3-16NE3
0
130
0
Slot 1
D3-16NE3
0
130
0
Slot 2
D3-08TA-1
0
160
0
Slot 3
D3-08TA-1
0
160
0
50
50
0
360
680
0
1040
120
500
D Other
Handheld prog D3-HPP
E Maximum Current Required F Remaining Current mDL3-20
3. the current used by the system devices (columns 3, 4, and 5), starting with Slot 1, then put the total in the row labeled “Maximum Current Required” (Row E). 4. the row labeled “Maximum Current Required” (Row E), from the row labeled “Current Supplied” (Row B). Place the difference in the row labeled “Remaining Current” (Row F). 5. “Maximum Current Required” is greater than “Current Supplied” in columns 3, 4 or 5, the power budget will be exceeded. It will be unsafe to use this configuration and you will need to restructure your I/O configuration.
1-800-633-0405
Page 3
For the latest prices, please check AutomationDirect.com.
DL305 Power Requirements This section shows the amount of power supplied by the base power supplies and the amount of power used by each DL305 device. Note the base power supplies provide three internal voltages (5V, 9V, 24V). The chart shows how much power from each of these power sources is required for each DL305 device. Use this information when calculating the power budget for your system. In addition to the three internal power sources, the DL305 bases provide an external power connection. There is 24 VDC available from the 24 VDC output terminals on the bases (except D3-05BDC and D3-10BDC). The 24 VDC can be used to power external devices or DL305 modules that require external 24 VDC. The power used from this external 24 VDC output reduces the internal system 24 VDC that is available to the modules by an equal amount. When using the 24 VDC output at the base terminal, it is recommended that 100 mA not be exceeded.
Power Consumed Device
Power Supplied
5V(mA) 9V(mA) 24V(mA) Ext req.
CPUs D3-330 D3-340 D3-350
300 300 500
50 20 0
0 0 0
0 0 0
DC Input Modules D3-08ND2 0 D3-16ND2-1 0 F3-16ND3F 0
10 25 148
112 224 68
0 0 0
10 10 100
0 0 0
0 0 0
0 0
0 0
AC Input Modules D3-08NA-1 D3-08NA-2 D3-16NA
0 0 0
AC/DC Input Modules D3-08NE3 D3-16NE3
0 0
10 130
DC Output Modules D3-04TD1 D3-08TD1 D3-08TD2 D3-16TD1-1 D3-16TD2
0 0 0 0 0
12 20 30 40 180
5 24 0 96 0
0 0 0 0 0
12 200 160 160 250 400
0 0 0 0 0 0
0 0 0 0 0 0
AC Output Modules D3-04TAS F3-08TAS-1 D3-08TA-1 D3-08TA-2 F3-16TA-2 D3-16TA-2
0 0 0 0 0 0
Device
5V(mA) 9V(mA) 24V(mA) 24 V (mA)
D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-08B-NR
900 900 900 900 900 900 900
2000 2000 2000 2000 2000 2000 2000
500 500 500 500 500 500 500
100 100 100 None None 100 100
D3-05BDC-NR 900
2000
500
None
Power Consumed Device
5V(mA) 9V(mA) 24V(mA) External required
Relay Output Modules D3-08TR F3-08TRS-1 F3-08TRS-2 D3-16TR
0 0 0 0
360 296 296 480
0 0 0 0
0 0 0 0
Analog Temperature and Thermocouple Modules F3-04ADS F3-08AD-1 F3-08THM-n F3-16AD F3-04DA-1 F3-04DAS
0 0 0 0 0 0
183 45 50 55 144 154
50 55 34 65 108 145
0 0 0 0 0 0
Communications and Networking D3-232 DCU D3-422 DCU FA-UNICON D3- DCM
500 500 0 0
0 0 0 300
0 0 0 0
Optional 5V@500mA Optional 5V@500mA 24V or 5V@ 100mA 0
10 70 5
112 0 0
0 0 0
50 50 0
0 0 0
0 0 0
0 0 0 0
0 150 0 0
0 0 0 0
0 0
0 0
0 0
Specialty Modules D3-08SIM D3-HSC D3-TCSU
0 0 40
Programming D3-HP D3-HPP D2-HP
50 50 200
Specialty CPUs F3-OMUX-1 F3-OMUX-2 F3-PMUX F3-RTU
409 262 455 416
Operator Interface DV-1000 150 C-more 210 Micro-Graphic www.automationdirect.com/dl305
DL305 PLCs mDL3-21
Page 4
For the latest prices, please check AutomationDirect.com.
Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. It’s as simple as plugging in a cable connector at either end or terminating wires at only one end. Prewired cables keep installation clean and efficient, using half the space at a fraction of the cost of standard terminal blocks. There are several wiring solutions available when using the ZIPLink System ranging from
PLC I/O-to-ZIPLink Connector Modules that are ready for field termination, options for connecting to third party devices, GS, DuraPulse and SureServo Drives, and specialty relay, transorb and communications modules. Pre-printed I/O-specific adhesive label strips for quick marking of ZIPLink modules are provided with ZIPLink cables. See the following solutions to help determine the best ZIPLink system for your application.
Solution 1: DirectLOGIC I/O Modules to ZIPLink Connector Modules When looking for quick and easy I/O-to-field termination, a ZIPLink connector module used in conjunction with a prewired ZIPLink cable, consisting of an I/O terminal block at one end and a multi-pin connector at the other end, is the best solution.
Using the PLC I/O Modules to ZIPLink Connector Modules selector tables located in this section, 1. Locate your I/O module/PLC. 2. Select a ZIPLink Module. 3. Select a corresponding ZIPLink Cable.
Solution 2: DirectLOGIC I/O Modules to 3rd Party Devices
When wanting to connect I/O to another device within close proximity Using the I/O Modules to 3rd Party Devices selector tables of the I/O modules, no extra terminal blocks are necessary when using located in this section, 1. Locate your PLC I/O module. the ZIPLink Pigtail Cables. ZIPLink Pigtail Cables are prewired to an I/O 2. a ZIPLink Pigtail Cable that is compatible terminal block with color-coded pigtail with soldered-tip wires on the with your 3rd party device. other end.
Solution 3: GS Series and DuraPulse Drives Communication Cables Need to communicate via Modbus RTU to a drive or a network of drives?
Using the Drives Communication selector tables located in this section, 1. Locate your Drive and type of communications. 2. Select a ZIPLink cable and other associated hardware.
ZIPLink cables are available in a wide range of configurations for connecting to PLCs and SureServo, SureStep, Stellar Soft Starter and AC drives. Add a ZIPLink communications module to quickly and easily set up a multi-device network.
mDL3-26
DL305 PLCs
1-800-633-0405
Page 5
For the latest prices, please check AutomationDirect.com.
Wiring Solutions Solution 4: Serial Communications Cables ZIPLink offers communications cables for use with DirectLOGIC, CLICK, and Productivity3000 CPUs, that can also be used with other communications devices. Connections include a 6-pin RJ12 or 9-pin, 15-pin and 25-pin D-sub connectors which can be used in conjunction with the RJ12 or D-Sub Feedthrough modules.
Using the Serial Communications Cables selector table located in this section, 1. Locate your connector type 2. Select a cable.
Solution 5: Specialty ZIPLink Modules For additional application solutions, ZIPLink modules are available in a variety of configurations including stand-alone relays, 24VDC and 120VAC transorb modules, D-sub and RJ12 feedthrough modules, communication port adapter and distribution modules, and SureServo 50-pin I/O interface connection.
Solution 6: ZIPLink Connector Modules to 3rd Party Devices If you need a way to connect your device to terminal blocks without all that wiring time, then our pigtail cables with color-coded soldered-tip wires are a good solution. Used in conjunction with any compatible ZIPLink Connector Modules, a pigtail cable keeps wiring clean and easy and reduces troubleshooting time.
www.automationdirect.com/dl305
Using the ZIPLink Specialty Modules selector table located in this section, 1. Locate the type of application. 2. Select a ZIPLink module.
Using the Universal Connector Modules and Pigtail Cables table located in this section, 1. Select module type. 2. Select the number of pins. 3. Select cable.
DL305 PLCs mDL3-27
Page 6
For the latest prices, please check AutomationDirect.com.
PLC I/O Modules to ZIPLink Connector Modules - DL305 DL305 PLC Output Module ZIPLink Selector PLC ZIPLink
DL305 PLC Input Module ZIPLink Selector PLC ZIPLink Input Module
# of Terms
Part Component Module No.
D3-08ND21
10
See Note 1
D3-16ND2-1
18
Feedthrough
ZL-RTB20
F3-16ND3F
18
Feedthrough
ZL-RTB20
D3-08NA-11
10
See Note 1
D3-08NA-21
10
See Note 1
D3-16NA
18
D3-08NE31
10
D3-16NE3
18
Cable Part No.
# of Terms Component 10
See Note 1
ZL-D3-CBL18 *
D3-08TD11
10
See Note 1
ZL-D3-CBL18 *
D3-08TD21
10
See Note 1
D3-16TD1-1
Feedthrough
ZL-RTB20
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
Sensor
ZL-LTB16-24
ZL-D3-CBL18 *
18
ZL-D3-CBL18 *
See Note 1
# of Terms Component
Module
Cable
F3-04ADS
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
F3-08AD-1
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
F3-16AD
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
F3-04DA-1
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
F3-04DAS
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
F3-08THM-J3 T/C Wire Only
See Note 3
F3-08THM-K3 T/C Wire Only
See Note 3
Module Part Cable Part No. No.
D3-04TD11
DL305 PLC Analog Module ZIPLink Selector PLC ZIPLink Analog Module
Output Module
Note: ZIPLink Connector Modules specifications follow the Compatibility Matrix tables. ZIPLink Cables specifications are at the end of this ZIPLink section.
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
Fuse
ZL-RFU204
ZL-D3-CBL18 *
Relay (sinking)
ZL-RRL16-24-1
ZL-D3-CBL18 *
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
Fuse
ZL-RFU204
Relay (sourcing)
ZL-RRL16-24-2
ZL-D3-CBL18 * ZL-D3-CBL18 *
D3-16TD2
18
D3-04TAS1
10
F3-08TAS-1
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
D3-08TA-1
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
D3-08TA-21
10 Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
Fuse
ZL-RFU204
ZL-D3-CBL18 *
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
Fuse
ZL-RFU20 4
ZL-D3-CBL18 *
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
Fuse
ZL-RFU20 4
ZL-D3-CBL18 *
F3-16TA-2
18
D3-16TA-2
18
D3-08TR1
10
See Note 1
See Note 1
See Note 1
D3-16TR2
18
F3-08TRS-12
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
F3-08TRS-22
18
Feedthrough
ZL-RTB20
ZL-D3-CBL18 *
* the cable length by replacing the * with: Blank = 0.5m, -1 = 1.0m, or -2 = 2.0m. I/O modules have non-removable terminal blocks which can be terminated using the ZL-CBL24-1P or 2P pigtail cable and the ZL-RTB20 module of the ZIPLink wiring system.
2 The D3-16TR, F3-08TRS-1 and F3-08TRS-2 relay outputs are derated not to exceed 2A per point and 4A per common when used with the ZIPLink wiring system.
3 F3-08THM-J and F3-08THM-K modules are not supported by the ZIPLink wiring system. 4 Fuses (5 x 20 mm) are not included. See Edison Electronic Fuse section for (5 x 20 mm) fuse. S500 and GMA electronic circuit protection for fast-acting maximum protection. S506 and GMC electronic circuit protection for time-delay performance. Ideal for inductive circuits. To ensure proper operation, do not exceed the voltage and current rating of ZIPLink module. ZL-RFU20 = 2A per circuit; ZL-RFU40 = 400 mA per circuit.
mDL3-28
DL305 PLCs
1-800-633-0405